100% found this document useful (1 vote)
515 views72 pages

Productcatalogue Salwico-Consilium

salwico manual

Uploaded by

Luis Vivanco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
515 views72 pages

Productcatalogue Salwico-Consilium

salwico manual

Uploaded by

Luis Vivanco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 72

Content

Foreword 4

Salwico Fire Detection System 6


Salwico Cargo Fire Detection Centrals 7
Control/Repeater panels 8
Salwico Cruise Fire Detection Centrals 8
Salwico Workboat Fire Detection Centrals 12
Accessories 13
Central Unit Accessories 14
Log Printer 14
Loop installation unit 14
Interfaces 15
Addressing Tool 15
Adressable Detectors 15
Accessories 18
Short circuit isolator 18
Addressable manual call pionts 19
Addressable I/O Units 19
Conventional Detectors 21
Manual Call Pionts 24
Equipment For Hazardeous Areas, Zone 0-1 24
Equipment For Hazardeous Areas, Zone 2 26
Base Plates 27
Test equipment 29
Test equipmane accessories 31
General Alarm Devices 32
Bells 32
Sounders 33
Lights 35
Combined Sounders and Lights 36
Door Control Accessories 36
Ventilation duct adapter 37
SIL 2 certified modules 39

Salwico Gas Detection System 44


Standard Centrals 45
Individual modules for custom made centrals 45
Control/Repeater Panels 48
Log Printer 48
Power Boost Loop units & Gas Detectors 48
Gas Detectors 49
Gas Detectors suitable for hazard environments 50
Open path gas detectors 52
Duct Mounting kits 52
Accessories for Gas Detectors 53
Alarm Devices 53
Portable Gas Detectors 56
Calibration Parts 57
Calibration Gas Bottles 58
Salwico Gas Sampling System SW2020 59

2
Content

Salwico Monitoring System 60


Salwico Emission Monitoring System 61
Salwico G1000 Smoke Density Monitoring System 67
Salwico G2000 Ambient Oil Mist Detection System 69

Marine approval
Consiliums products and applications are approved by the major classification soceieties.

3
Content

Consilium develops and markets products, services and systems


for safety, navigation and automation applications. The guiding
principle behind Consilium’s products and systems is to help
protect people, the environment and material values.
With a stable base of proprietary products, complemented by
high-quality external brands, and a global market organisation,
Consilium ranks among the world’s leading suppliers to the
international shipping, transport and oil and gas industries.

Why Consilium? Marine & Safety


Consilium AB is one of the world-leading suppliers of The business area Marine & Safety focus on the interna-
products and systems for safety, navigation, environmental tional shipping industry and offers products and systems
monitoring and automation solutions. We are established in for safety and navigation. The range of products includes
all the world’s important countries within shipbuilding, ship- fire and gas detection systems, integrated navigation sys-
ping and in the oil and gas industry. With our global sales tems, marine voyage data recorders, speed logs and radar
and service organization we are able to be your sales and systems. Consilium also offer systems for measuring the
service support where ever you are. emissions of greenhouse gas from ships.

Our mission is to protect human lives, assets and the envi- We hold a strong position by offering service and support
ronment and to make a difference when safety matters. all over the world which is an important criteria for ship-
ping companies as well as shipyards when making invest-
Business development ment decision.
Based on our market and technical knowledge, we invest
in new areas and currently have a number of interesting Marine & Safety business area also offers safety solutions
business development projects in our portfolio. Many busi- for land transportation and building safety and we have
ness projects have developed beyond expectations, which established ourselves as a leading supplier of fire detection
have resulted in new separate business areas and separate solutions for trains.
divisions or new products and solutions. This is the case
with products and systems for military vessels, special radar Fire safety & Automation
system for detection of oil spills, port surveillance, ECDIS In the Fire safety & Automation business area, Consilium
and integrated navigational systems. supplies automation products as well as fire and safety
systems for oil and gas plants. The product range includes
instrumentation, control systems, automated inventory
management for tank farms and terminals, solutions for fire
and gas detection, oil and gas pipeline leak detection, fire
extinguishing systems, emergency shutdown systems and
communication systems.

4
Content

After-Sales Support Key facts/benefits:


At Consilium we offer an extensive after sales support • Modification and maintenance
program which includes everything from service and main- • Telephone and e-mail support
tenance of all supplied systems to supply of spare parts • On site trouble shooting
and retrofitting of older installations. • Calibration
• Annual Performance Test (APT) of systems
We offer commissioning and world-wide after-sales sup- • World-wide network of own service stations
port of all our products through our wide network of • Training of onshore and offshore staff
own offices and representatives. We offer our customers
spare parts that are backward compatible with the major- Management System
ity of our delivered systems. We provide full 24/7 support We have established, documented, implemented and main-
and take care of the service of your systems by our highly tained a quality management system to continually improve
skilled engineers. the effectiveness. This provides a structured process for
the achievement of product quality and customer satisfac-
tion in accordance with the requirements of international
standards.

5
Salwico Fire Detection System

Salwico
Fire
Detection
System

6
Salwico Fire Detection System
Salwico Cargo Fire Detection Centrals
Salwico Cargo, with integrated control panel
Salwico Cargo is a fully SOLAS compliant fire detection central. It is supplied both as
analogue addressable or conventional version. Tested and certified by all the major clas-
sification societies, this system provides optimal fire detection for merchant vessels. Sal-
wico Cargo cabinet is in some versions featured with general alarm system. The control
panel is embedded into the main cabinet and it provides possibility to attach remote
control and repeater panels to the main cabinet.

Addressable Salwico Cargo,, with integrated control panel


F400-101-X010YA 2 -6 loops and 8-16 relays alt.
F800-101-X010YA 8 - 32 Conventional Sections and 8-16 Relays

Conventional 400 = Wall mounted


F400-101-XY100A 800 = Recess mounted
F800-101-XY100A Addressable:
X = No of relay modules 1 or 2, Y = No of loop modules 2 - 6
Conventional:
X = No of relay modules 1 or 2, Y = No of I/O 70 module 1 - 4

Salwico Cargo, including cabinet and external control panel


Salwico Cargo is a fully SOLAS compliant fire detection central. It is supplied both as
analogue addressable or conventional version. Tested and certified by all the major clas-
sification societies, this system provides optimal fire detection for merchant vessels. Sal-
wico Cargo cabinet is in some versions featured with general alarm system. The control
panel is installed separately on any location and possibility to attach remote control and
repeater panels to the main cabinet is provided.

Addressable Salwico Cargo, including cabinet and external control panel


F000-101-X010YA 2 -6 loops and 8-16 relays alt.
F010-101-X010YA 8 - 32 Conventional Sections and 8-16 Relays

Conventional Addressable
F000-101-XY100A 000 = 440x400x180 Cabinet / 010 = 440x570x180 Cabinet
X = No of relay modules 1 or 2, Y = No of loop modules 2 - 6
Conventional
X = No of relay modules 1 or 2, Y = No of I/O 70 module 1 - 4

7
Salwico Fire Detection System
Control/Repeater panels
Control/Repeater M 4,3 Cargo
The Control/Repeater Panel M 4.3 is a control panel with a 4.3” graphical colour display
used to manage and supervise a system. It mounts on any flat surface independently
from a fire alarm cabinet and is equipped with communication buses for connecting
to the system. USB In front of the panel provides easy access to the system’s data and
diagnostic logs. It also provides the following features:
• A backlit 4.3” graphical colour display • Alarm buzzer • LED status indicators
• Backbone Bus Interface • Ethernet connection • RS-422/RS-485 serial interface
• RS-232/RS-485 serial interface • Three USB interfaces • Two configurable powered
I/Os • Two programmable relay outputs
5100195-20A

Salwico Cruise Fire Detection Centrals


Salwico Cruise, with integrated control panel
Salwico Cruise is a fully SOLAS compliant fire detection central. Tested and certified by
all the major classification societies, this system provides optimal fire detection for large
vessels. Fire Detection Centrals are fully customised using all benefits of flexible system
design. Main features of such centrals are Modularity, Full Redundancy on multiple levels
including CPU, Power and Communication, Hot-Swap on module level. All to insure
maximum availability possible, allowing lowest lifetime cost.
Salwico Cruise systems are fully Safe Return To Port compliant.

Control M X H
Control M X is used in three different ways:
• As a central controller (Master) in a Fire detection system.
• As a central backup controller (Slave) in a Fire detection system.
• As a provider of additional communication channels, additional external communica-
tion, or as an extension bus.
A Control M X provides the following features:
• Ethernet connection • RS-422/RS-485 interface
• RS-232/RS-485 interface • Two programmable relay outputs
For details on assembling a system and definitions of common system terms, refer to
5100002-02A the Installation Manual.

Loop M X H
Loop M X enables the connection of one addressable detector loop. For details on
assembling a system and definitions of common system terms, refer to the Installation
Manual.

5100026-01A

8
Salwico Fire Detection System

Buscon M 10 H
BusCon M 10 has two major functions:
• Terminal board for functions in Control Panel M4.3 and Control/Repeater M4.3
• Terminal board for Backbone Bus External BBE (RS485 Repeater)
These functions can be used together or individually. The module BusCon M 10 has
one connection for either RS232 or RS485 communication. For details on assembling a
system and definitions of common system terms, refer to the Installation Manual.
Note! BusCon M 10 does not provide a galvanically isolated bus communication BBE.
Operating voltage range 19-30 VDC

5100056-01A

Buscon M 20 H
The BusCon M 20 connects the Control Panel M 4.3 to the backbone bus and provides
connection terminals for functions from Control Panel M 4.3. The module BusCon M 20
has two relay outputs and one channel for RS422 or RS485 communication. For details
on assembling a system and definitions of common system terms, refer to the Installa-
tion Manual.

5100054-01A

Bus Isolator
Bus Isolator M divides the system backbone bus into segments. Its dual functionality iso-
lates communications and basic backup signals between the stretched system parts and
provides power to the control panel (e.g. Control Panel M 4.3). For details on assem-
bling a system and definitions of common system terms, refer to the Installation Manual.

5100071-01A

I/O M 70 H
I/O M 70 provides eight programmable I/O 70 channels, each individual channel can be
configured as either:
• Programmable Inputs
• Programmable Outputs max 70mA for buzzers, relays etc
• Conventional detector zones
This module monitors conventional detectors, digital inputs, two-wired inductive sen-
sors and controls low-power units, such as buzzers and relays. For details on assembling
a system and definitions of common system terms, refer to the Installation Manual.

5100075-01A

9
Salwico Fire Detection System

I/O M 700 H
I/O M 700 provides eight programmable I/O 700 channels, used for either:
• Programmable Inputs
• Outputs max* 700 mA for magnets, power supply etc
Use the I/O M 700 as an input module, or use it to monitor, control, and/or supply
units such as alarm devices, magnets. It can also provide constant power supply to other
system modules such as Control and Repeter Panels etc. For details on assembling a
system and definitions of common system terms, refer to the Installation Manual.
* Used as an output module, I/O M 700 can provide max output 1400 mA, if two out-
puts are connected together.
5100077-01A

Relay M 8 H
Relay M 8 provides eight programmable relay contacts. Each of these relay contacts pro-
vide a potential free change-over contact. Use Relay M 8 to control units such as sirens,
magnets, flashlight, alarms and ventilation fans. For details on assembling a system and
definitions of common system terms, refer to the Installation Manual.

5100081-01A

Charger M H
Charger M provides power to the system through the Backbone Bus. It connects to
either a change-over module or directly to a power supply, supervises change-over
and connects the power supply units. By using dual Charger M modules, it is possible
to replace one Charger M module without powering down the system. For details on
assembling a system and definitions of common system terms, refer to the Installation
Manual.

5100062-01A

Change Over M X H
The Change Over M X can switch automatically between two power sources, mains
and emergency, with preference towards mains power if both sources are operational.
The Change Over M X is used to connect to the PSU module in a system, and is also
provided with one extra power supply outlet (which can be used for example to a
printer). This is a separate module without any contact with the backbone bus. For
details on assembling a system and definitions of common system terms, refer to the
Installation Manual.

5100066-01A

10
Salwico Fire Detection System

Change Over M EXT H


Change Over M Ext monitors mains and emergency power inputs and gives fault indi-
cation if either supply is lost. The power input status is indicated by the front panel LEDs.
Change Over M Ext provides two separate controllable 230 VAC outputs, OUT 3 and
4, protected by separate front mounted fuses. There are also two separate programma-
ble change over relays, OUT 5 and 6. OUT 3-6 are used to control units such as sirens,
magnets, flashlights, alarms and ventilation fans. For details on assembling a system and
definitions of common system terms, refer to the Installation Manual.

5100068-01A

PSU M AC/DC 5A
PSU M AC/DC 5A powers the system. It is short-circuit proof and can be used in pairs
to supply 5+5 A. For details on assembling a system and definitions of common system
terms, refer to the Installation Manual.

5100087-01A

PSU M DC/DC 5A
The Dimension CD-Series offer DIN-rail DC/DC converters in the 92-120W output
power range in a very compact housing. These DC/DC converters are allowed to run
with a battery or similar sources or can also be used to refresh and stabilize the 24Vdc
on the end of long cable runs. The basic units include all the essential basic functions
while the -S1 version is equipped with quick connect spring clamp terminals, a DC-OK-
contact which monitors the output and an input-low-relay-contact. The –L1 version ad-
ditionally fulfils the NEC Class 2 requirements. All devices except the CD5.241-L1 have
a PowerBoost of 20% incorporated. This extra power can even be used continuously up
to +45°C.
5100088-01A

Control/Repeater M 4,3 Cruise


The Control/Repeater Panel M 4.3 is a control panel with a 4.3” graphical colour display
used to manage and supervise a system. It mounts on any flat surface independently
from a fire alarm cabinet and is equipped with communication buses for connecting
to the system. USB In front of the panel provides easy access to the system’s data and
diagnostic logs. It also provides the following features:
• A backlit 4.3” graphical colour display • Alarm buzzer
• LED status indicators • Backbone Bus Interface
• Ethernet connection • RS-422/RS-485 serial interface
• RS-232/RS-485 serial interface • Three USB interfaces
5101003-50A • Two configurable powered I/Os • Two programmable relay outputs

11
Salwico Fire Detection System

Repeater M 4,3
The Control/Repeater Panel M 4.3 is a control panel with a 4.3” graphical colour display
used to manage and supervise a system. It mounts on any flat surface independently
from a fire alarm cabinet and is equipped with communication buses for connecting
to the system. USB In front of the panel provides easy access to the system’s data and
diagnostic logs. It also provides the following features:
• A backlit 4.3” graphical colour display • Alarm buzzer
• LED status indicators • Backbone Bus Interface
• Ethernet connection • RS-422/RS-485 serial interface
• RS-232/RS-485 serial interface • Three USB interfaces
5100096-20A • Two configurable powered I/Os • Two programmable relay outputs

Salwico Workboat Fire Detection Centrals


Salwico Workboat AI
Salwico Workboat AI is an analogue addressable fire detection system with 2 fire detec-
tor loops SOLAS compliant. Tested and certified by all major classification societies, this
system provides an optimal fire detection solution for smaller vessels.

The system is managed and supervised through Control Panel M 4.3. The Control Panel
M 4.3 is mounted on the front of the fire alarm cabinet.

5102002-01A

Salwico Workboat AE
Salwico Workboat AE is an analogue addressable fire detection system with 2 fire
detector loops SOLAS compliant. Tested and certified by all major classification societies,
this system provides an optimal fire detection solution for smaller vessels.

The system is managed and supervised through Control Panel M 4.3. The Control Panel
M 4.3 is mounted separately from the fire alarm cabinet.

5102002-02A

Salwico Workboat CI
Salwico Workboat CI is a conventional fire detection system with 8 fire detector sec-
tions SOLAS compliant. Tested and certified by all major classification societies, this
system provides an optimal fire detection solution for smaller vessels.

The system is managed and supervised through Control Panel M 4.3. The Control Panel
M 4.3 is mounted on the front of the fire alarm cabinet.

5102013-01A

12
Salwico Fire Detection System

Salwico Workboat CE
Salwico Workboat CI is a conventional fire detection system with 8 fire detector sec-
tions SOLAS compliant. Tested and certified by all major classification societies, this
system provides an optimal fire detection solution for smaller vessels.

The system is managed and supervised through Control Panel M 4.3. The Control Panel
M 4.3 is mounted separately from the fire alarm cabinet.

5102013-02A

Accessories
PSU Kit Workboat 5A DC/DC
This PSU Kit provides ultimate isolation and voltage regulation of power supply to Sal-
wico Workboat centrals when 24VDC power is used as the only supply of the central.
Only one PSU kit is to be used per power supply channel, i.e. in case when both main
and Emergency supply is 24VDC it will be necessary to install two PSU Kits.
Features
• 24VDC 5A adjustable • Long lifetime insured
• Status supervision and indication • Installations kit included
The PSU kit is suitable for all versions of Salwico Workboat fire alarm centrals.
5102021-20A

Relay Kit Workboat


The relay kit is used to convert 24VDC powered outputs of I/O 700 Module into dry
relay contact outputs. When so is needed this outputs can be used as control outputs
controlling various external devices from Salwico Workboat fire detection central unit.
Features
• Breaking Capacity 250 VAC 6A • 2 Pole
• LED Status indicator • DIN-Rail mounted
• Installations cable kit included

5102024-00A

13
Salwico Fire Detection System
Central Unit Accessories
Log Printer
OKI ML280
The ML280 elite is a fast and robust log-printer. It can be connected to all Salwico fire
and gas alarm systems that has a RS232 printer output. aper can be fed from the bot-
tom, from the behind or from the top. Single sheet paper or continuous paper can be
used. The cable connections are on the back of the printer. The robust construction
makes the ML280 elite suitable for harsh environments

7680

Mini printer
The mini printer is an embedded printer to the fire detection central and very silent
through direct thermal printing method. The printer has an abundant figure/curves/char-
acters print function and a copy function of LCD screen.

5200087-00A

Loop installation unit


SE3000+ Loop test unit
SE3000+ is a small hand hold test device for Salwico Fire Alarm Systems. It can be used
to execute two different tests, a loop test and a loop unit test. The loop test automati-
cally boots the complete loop and searches all addresses on the loop. All the informa-
tion found about the addresses is saved in a list, which can be printed out or scrolled
through on the display. The loop unit test searches for the manually requested address
and immediately displays all information found about the unit. More information about
SE3000+ can be found in the manual SE3000+ User Guide (part no 046481) and in
the Short Guide printed on the bottom of the device.
047480

14
Salwico Fire Detection System

Interfaces
ST Interface M
ST Interface M is used for interfacing “old Servoteknikk” loops into the new Salwico
systems. Perfect solution for retrofitting elderly systems with newer central cabinet. This
Module can be used in combination with virtually any Salwico addressable central. One
such module is required per each addressable loop.

5100433-02A

Standard communication protocols


Standard communication protocols available for integrations with other systems
• NMEA 0183
• MODBUS RTU
• MODBUS TCP/IP
• ESPA 444

Addressing Tool
EV-AD 2 addressing tool
The Evolution Address Programmer is used to set the address in Salwico Evolution fire
alarm detectors in a marine environment (Hard Customer Code 2). The detector is
attached to the programmer. The procedure to set or change the address takes only a
few seconds. The EV-AD2 requires two 9 V PP3 non-rechargeable alkaline batteries. The
programmer indicates when the battery is low.

5200123-00A

Addressable Detectors
EV-P Analogue Addressable Optical Smoke Detector
Salwico EV-P is an analogue addressable smoke detector with an optical chamber. It is
designed to give early warning for the presence of smoke in the supervised area. At the
same time the detector offers a high protection against unwanted alarms. Salwico EV-P
is equipped with OMNIVIEW 360° LED indicator giving a clear, full 360° visibility of the
red alarm indication. The detector can be placed in harsh environments if it is mounted
on a splash proof base. The technical detector address is set with a special program-
ming tool, valid addresses are 1-254. Salwico EV-P has a fine pitch net which improves
the response to smoke and also reduces the amount of dust etc. entering the detector.
040020 Salwico EV-P is equipped with an output for remote indication.

15
Salwico Fire Detection System

EV-PH Analogue Addressable Optical Dual Smoke/Heat Detector


for dry space IP22
Salwico EV-PH is an analogue addressable combined optical smoke and heat detector.
It is designed to give early warning for the presence of heat and smoke in the super-
vised area. Both heat and smoke alarm can be generated individually. At the same time
Salwico EV-PH offers a high protection against unwanted alarms. Salwico EV-PH is
equipped with OMNIVIEW 360° LED indicator giving a clear, full 360° visibility of the
red alarm indication. The detector can be placed in harsh environments if it is mounted
on a splash proof base. The technical detector address is set with a special program-
ming tool, valid addresses are 1-254. Salwico EV-PH has a fine pitch net which improves
040030 the response to smoke and also reduces the amount of dust etc. entering the detector.
Salwico EV-PH is equipped with an output for remote indication.

EV-DPH-A2R
Salwico EV-DPH-A2R is an analogue addressable smoke and heat detector with a dual
wavelength optical chamber. Two light sources with different wavelengths are used,
giving the detector a stable reaction to different kinds of smoke and making it insensi-
tive to unwanted alarms caused by e.g. water steam. Salwico EV-DPH-A2R is equipped
with Omniview™ 360° LED indicator giving a clear, full 360° visibility of the red alarm
indication. The technical detector address is set with a special programming tool. Valid
addresses are 1-254. Salwico EV-DPH-A2R is equipped with an output for remote
indication.
40050

EV-H/A1R 54°C Analogue Addressable Heat


Salwico EV-H is an analogue addressable heat detector. Salwico EV-H is designed to
give early warning for he presence of heat in the supervised area, and is available in two
temperature classes: A1R (fixed 54°C + rate of rise 0.8°C/min) and CS (fixed 84°C),
see separate part no. for 84°C.Salwico EV-H is equipped with OMNIVIEW 360° LED
indicator giving a clear, full 360° visibility of the red alarm indication. The detector can
be placed in harsh environments if it is mounted on a splash proof base.The techni-
cal detector address is set with a special programming tool, valid addresses are 1-254.
Salwico EV-H is equipped with an output for remote indication. For detailed information
about appropriate systems for the detector, see separate document “Compatibility of
040000
Loop Units/System”.

EV-H A1R 54ºC IP67


Salwico EV-H is an analogue addressable heat detector moulded together with base
adapter SPB-ADAPT to fulfil IP67. Salwico EV-H is designed to give early warning for
the presence of heat in the supervised area, and is available in two temperature classes:
A1R (fixed 54°C + rate of rise 0.8°C/min) and CS (fixed 84°C), see separate part no.
for 84°C. Salwico EV-H is equipped with OMNIVIEW 360° LED indicator giving a clear,
full 360° visibility of the red alarm indication. The detector can be placed in harsh envi-
ronments if it is mounted on a splash proof base. The technical detector address is set
with a special programming tool, valid addresses are 1-254. Salwico EV-H is equipped
40001 with an output for remote indication. For detailed information about appropriate sys-
tems for the detector, see separate document “Compatibility of Loop Units/System”.

16
Salwico Fire Detection System
EV-H A1R 54ºC IP67 SCI
Salwico EV-H is an analogue addressable heat detector molded together with base
adapter SPB-ADAPT SCI to fulfill IP67 ingress protection class. Salwico EV-H is designed
to give early warning for the presence of heat in the supervised area, and is available in
two temperature classes: A1R (fixed 54°C + rate of rise function according to EN54-
5) and CS (fixed 84°C), see separate part no. for 84°C. Salwico EV-H is equipped
with OMNIVIEW 360° LED indicator giving a clear, full 360° visibility of the red alarm
indication. The technical detector address is set with a special programming tool. Valid
addresses are 1-254. Salwico EV-H is equipped with an output for remote indication.
SPB-ADAPT SCI is developed to provide Short Circuit Protection in the detector base.
Short Circuit Isolator function is fully transparent and do not require any setting. Short
5100472-00A Circuit Isolator protects the loop cable from short circuit by breaking positive side of
loop cable.

EV-H/CS 84°C Analogue Addressable Heat


Salwico EV-H is an analogue addressable heat detector. Salwico EV-H is designed to give
early warning for the presence of heat in the supervised area, and is available in two
temperature classes: CS (fixed 84°C) and A1R (fixed 54°C + rate of rise 0.8°C/min),
see separate part no. for 54°C. Salwico EV-H is equipped with OMNIVIEW 360° LED
indicator giving a clear, full 360° visibility of the red alarm indication. The detector can
be placed in harsh environments if it is mounted on a splash proof base. The techni-
cal detector address is set with a special programming tool, valid addresses are 1-254.
Salwico EV-H is equipped with an output for remote indication. For detailed information
about appropriate systems for the detector, see separate document “Compatibility of
Loop Units/System”.
040005

EV-H CS 84ºC IP67


Salwico EV-H is an analogue addressable heat detector moulded together with base
adapter SPB-ADAPT to fulfil IP67. Salwico EV-H is designed to give early warning for
the presence of heat in the supervised area, and is available in two temperature classes:
CS (fixed 84°C) and A1R (fixed 54°C + rate of rise 0.8°C/min), see separate part no.
for 54°C. Salwico EV-H is equipped with OMNIVIEW 360° LED indicator giving a clear,
full 360° visibility of the red alarm indication. The detector can be placed in harsh envi-
ronments if it is mounted on a splash proof base. The technical detector address is set
with a special programming tool, valid addresses are 1-254. Salwico EV-H is equipped
40006 with an output for remote indication. For detailed information about appropriate sys-
tems for the detector, see separate document “Compatibility of Loop Units/System”.

EV-H CS 84ºC IP67 SCI


Salwico EV-H is an analogue addressable heat detector molded together with base
adapter SPB-ADAPT SCI to fulfill IP67 ingress protection class. Salwico EV-H is designed
to give early warning for the presence of heat in the supervised area, and is available in
two temperature classes: CS (fixed 84°C+ rate of rise function according to EN54-5)
and A1R (fixed 54°C ), see separate part no. for 54°C. Salwico EV-H is equippe with
OMNIVIEW 360° LED indicator giving a clear, full 360° visibility of the red alarm
indication. The technical detector address is set with a special programming tool. Valid
addresses are 1-254. Salwico EV-H is equipped with an output for remote indication.
SPB-ADAPT SCI is developed to provide Short Circuit Protection in the detector base.
5100470-00A Short Circuit Isolator function is fully transparent and do not require any setting. Short
Circuit Isolator protects the loop cable from short circuit by breaking positive side of
loop cable.
17
Salwico Fire Detection System

EV-PP/OA130
The detector is an analogue addressable optical smoke and heat detector. The smoke
and heat detector functions are independent and can be used in any required combina-
tion. The detector is designed to give early warning for the presence of heat and smoke
in the supervised area. The detector offers a high protection against unwanted alarms.
The low profile combined with the Omniview™ 360° alarm indication makes the
detector suitable for sites with high architectural requirements. The address is set by an
8-way DIP-switch. The detector comes in different versions depending which detector it
replaces.
040200

AC-IR-3Fq Triple-IR Flame detector


The AC-IR-3Fq is a triple frequency conventional infrared flame detector produced us-
ing the latest in manufacturing technology. The Detector is using infrared elements suit-
able for the detection of smokeless combustible liquid and gas fires, as well as smoke-
forming open fire involving carbonaceous materials as contained in wood, plastics, gases,
oil products etc. The Fire evaluation process is done by triple Infrared (3Fq) sensor, pro-
tected by a sapphire glass filtering >6.0μm wavelength radiation. Sensor measures the
hot carbon dioxide in a specific flame wavelength; the B and C sensors simultaneously
measure the interference radiation in near wavelengths. This technique together with
intelligent signal processing through microprocessor and custom algorithms, achieves
excellent detection reliability while maintaining the highest immunity to interference
5200236-00A
radiation and sunlight.

Accessories
SUM-2, Local Buzzer for Addressable detectors
The SUM-2 is a buzzer unit developed for the addressable detectors RDJ-2T, OA120,
OA130, IA120, IA130, NS-AIS, NS-AOS, NS-AIHS, NS-AOHS, NS-AH/AIS, NS-AH/CS
NS-AUV, EV-H, EV-P, EV-PH and EV-DP. There is no limitation to the number of detec-
tors on a loop that can be equipped with a buzzer, each can have a SUM-2 buzzer
attached to it. For CS3000 two of these buzzers can be defined and controlled via
external control. A maximum of three buzzers can be imultaneously activated on the
same loop. For CS4000 and NSAC-1 a maximum of 50 buzzers can be activated simul-
taneously on the same loop.
044577-2

Short circuit isolator


Salwico NMI SCI
NMI SCI is a short circuit isolator for montage on 5mm DIN-rail. Developed to provide
short circuit protection of loop cable and devices, specifically in cases when detectors
detour from loop path. The unit is designed for use in dry and clean spaces. NMI SCI
can only be used on addressable loops. Short Circuit Isolator function is fully transpar-
ent and does not require any settings. The short circuit isolator unit can be used for all
Salwico fire alarm systems. Features and benefits
• Small size
• DIN-Rail montage (acc. to EN50022)
• Easy termination access
5200315-00A • Quick and safe Short Circuit Isolation

18
Salwico Fire Detection System
Addressable manual call points
MCP-A SCI
MCP-A SCI is an addressable manual call point for indoor environment, designed for
Salwico fire alarm systems. Pressing the glass causing it to crack activates the fire alarm.
A protective plastic coating on the glass prevents operator injury. An LED on the front
of the call point indicates the fire alarm. The LED remains lit until the fire alarm has been
reset on the fire alarm panel. The call point can be tested with a special key, included in
the delivery. The address of the call point is set with a DIP-switch. MCP-A SCI is devel-
oped to provide Short Circuit Protection. The Short Circuit Isolator function is
fully transparent and do not require any setting. In order to achieve IP23 the MCP-A
5200030-02B
SCI shall be mounted on a smooth surface and the cable inlet/outlet shall be secured
against leakage.

MCP-A WP SCI
MCP-A WP SCI is an addressable manual call point, designed for Salwico fire alarm
systems. The selected material PC/ABS and the encapsulation, with ingress protection
IP67, makes it very suitable for harsh environment. Pressing the glass causing it to crack
activates the fire alarm. A protective plastic coating on the glass prevents operator injury.
An LED on the front of the call point indicates the fire alarm. The LED remains lit until
the fire alarm has been reset on the fire alarm panel. The call point can also be tested
with a special key, included in the delivery. The address of the call point is set with a
DIP-switch. MCP-A WP SCI is developed to provide Short Circuit Protection. The Short
Circuit Isolator function is fully transparent and do not require
5200031-02B
any setting.

Addressable I/O Units


IC44 WP
IO-unit with 4 inputs and 4 outputs in IP67 housing. Can control and
supervise single and double doors. Inputs support PNP and NPN sensors. Outputs of
relay type

5200268-00A

IC44 WPL
IO-unit with 4 inputs and 4 outputs in large IP67 housing. Can control and supervise
single and double doors. Inputs support PNP and NPN sensors. Outputs of relay type

5200269-00A

19
Salwico Fire Detection System

IC10
IO-unit in IP22 housing. Can be used as interface for conventional
alarming devices, control or indication.

5200272-00A

IC10 WP
IO-unit in IP66 housing. Can be used as interface for
conventional alarming device, control or indication

5200273-00A

TC10
Programmable timer unit used for the control or disablement of other devices.

5200276-00A

FP10 WP
Fire patrol unit in IP67 housing.

5200277-00A

20
Salwico Fire Detection System

FP10
Fire patrol unit in IP22 housing.

5200283-00A

IC21 WP
The IC21 WP is an addressable unit used for control and indication of fire doors, fire
dampers etc. in a fire alarm system. This unit has been designed for use in damp spaces.
IC21 WP can control and supervise both single and double doors. The unit includes two
inputs, one programmable output and one secondary output controlled by an external
switch. The loop address of the IC21 WP is set by a DIP-switch.

5200270-00A

IC21 WPL
The IC21 WPL (equipped with an extra large enclosure) is an addressable unit used for
control and indication of fire doors, fire dampers etc. in a fire alarm system. This unit has
been designed for use in damp spaces. IC21 WPL can control and supervise both single
and double doors. The unit includes two inputs, one programmable output and one
secondary output controlled by an external switch. The loop address of the IC21 WPL
is set by a DIP-switch.

5200278-00A

Conventional Detectors
EC-H/A2S 58°C CONV HEAT DET, dry space IP22
The EC-H/A2S conventional heat detector belongs to Salwico EC range of detectors.
EC is a range of conventional detectors, which have been produced using the latest in
manufacturing technology and supplied with an array of advanced features. The EC-H/
A2S thermal detector uses a state of the art thermal element combined with an ap-
plication specific integrated circuit (ASIC) to provide quick and accurate detection of
fires. The detector incorporates a static element and is suitable where ambient condi-
tions normally exhibit rapid changes in temperature e.g. galley. The EC-H/A2S detector
also has an integral LED, which illuminates to provide a local alarm signal. An optional
remote LED annunciator may be used to repeat any alarm signal.
5200172-00A

21
Salwico Fire Detection System
EC-H/BS 78°C CONV HEAT DET, dry space IP22
The EC-H/BS conventional heat detector belongs to Salwico EC range of detectors.
EC is a range of conventional detectors, which have been produced using the latest in
manufacturing technology and supplied with an array of advanced features. The EC-H/
BS thermal detector uses a state of the art thermal element combined with an applica-
tion specific integrated circuit (ASIC) to provide quick and accurate detection of fires.
The detector incorporates a static element and is suitable where ambient conditions
normally exhibit rapid changes in temperature e.g. galley. The EC-H/BS detector also has
an integral LED, which illuminates to provide a local alarm signal. An optional remote
LED annunciator may be used to repeat any alarm signal.
5200173-00A

EC-H/A1R 58°C ROR CON HEAT DET, dry space IP22


The EC-H/A1R conventional heat detector belongs to Salwico EC range of detectors.
EC is a range of conventional detectors, which have been produced using the latest in
manufacturing technology and supplied with an array of advanced features. The EC-H/
A1R thermal detector uses a state of the art thermal element combined with an ap-
plication specific integrated circuit (ASIC) to provide quick and accurate detection of
fires. The detector incorporates both rate of rise and static elements and is suitable for
all areas where the ambient conditions do not normally exhibit rapid changes in tem-
perature. The EC-H/A1R detector also has an integral LED, which illuminates to provide
a local alarm signal. An optional remote LED annunciator may be used to repeat any
5200174-00A alarm signal.

EC-P CONV OPTICAL SMOKE DET, Dry Space IP22


The EC-P photoelectric smoke detector belongs to Salwico EC range of detectors.
EC-P is a range of conventional detectors, which have been produced using the latest
in manufacturing technology and supplied with an array of advanced features. The EC-P
photoelectric smoke detector uses a state of the art optical chamber combined with
an application specific integrated circuit (ASIC) to provide quick and accurate detection
of fires. A combination of the unique chamber design and other technically advanced
features will significantly extend the service intervals before cleaning of the detector
becomes necessary.

5200175-00A

EC-PH/A1R 58°C ROR OPT S/H DET, Dry Space IP22


The EC-PH/A1R multi-criteria detector belongs to EC range of detectors. Salwico EC is
a range of conventional detectors, which have been produced using the latest in manu-
facturing technology and supplied with an array of advanced features. The EC-PH/A1R
multi-criteria detector uses a state of the art optical chamber and a thermal element
combined with a microprocessor, running sophisticated algorithms to provide quick and
accurate detection of fires. The combination of photoelectric and thermal characteristics
provides a faster response to ‘real fire’ situations, while at the same time reducing the
risk of unwanted environmentally generated alarms.
5200176-00A

22
Salwico Fire Detection System
HC100 A2 Conventional Heat Detector (57°DegC)
The HC100 A2 is a conventional heat detector for use with all Salwico Fire Alarm
Systems. The detector is with its low profile and smooth design very suitable in locations
with high architectural requirements such as offices, restaurants, hotel rooms and cabins.
The heat sensing element is of thermistor type with a short response time to changes
in the ambient temperature. Alarms are optically indicated until they are reset on the
central. The detector is environmentally adapted in aspects of the selection of material
and design. The detector is polarisation independent (unless the remote output is used)
which simplifies the installation. The mesh is very easy to change and clean which simpli-
fies maintenance.
038000

HC100 A2 Conventional Heat Detector (57°DegC) IP67


The HC100 A2-IP67 is a conventional heat detector for use with all Salwico Fire Alarm
Systems. It is delivered complete with adapter and base. In this version of HC100 the
detector and adapter are moulded together and filled with a special moulding com-
pound that gives it high resistance against dampness and vibrations. The detector cannot
be separated from the adapter. The HC100 A2-IP67 is suitable for location in harsh en-
vironments. The heat sensing element is of thermistor type with a short response time
to changes in the ambient temperature. Alarms are optically indicated until they are
reset on the central. The detector is environmentally adapted in aspects of the selec-
38005 tion of material and design. The detector is polarisation independent (unless the remote
output is used) which simplifies the installation.

HC/100 D Conventional Heat detector head (100°DegC)


The HC100 D is a conventional heat detector for use with all Salwico Fire Alarm Sys-
tems. The detector is with its low profile and smooth design very suitable in locations
with high architectural requirements such as offices, restaurants, hotel rooms and cabins.
The heat sensing element is of thermistor type with a short response time to changes
in the ambient temperature. Alarms are optically indicated until they are reset on the
central. The detector is environmentally adapted in aspects of the selection of material
and design. The detector is polarisation independent (unless the remote output is used)
which simplifies the installation. The mesh is very easy to change and clean which simpli-
fies maintenance.
038020

SWM-1KL/140, Conventional Heat Detector (140°DegC)


The SWM-1KL 140 is a fixed temperature heat detector, designed for use in damp
spaces. It contains a bimetallic thermostat, which closes its contacts at alarm tempera-
ture. The detector is also available in versions with lower alarm temperature (57, 80 and
100°C) and in an intrinsically safe version, SWM-1KL/IS, see separate datasheets.

037174

23
Salwico Fire Detection System
AC-IR-3Fq Trippel-IR Flame detector
The AC-IR-3Fq is a triple frequency conventional infrared flame detector produced us-
ing the latest in manufacturing technology. The Detector is using infrared elements suit-
able for the detection of smokeless combustible liquid and gas fires, as well as smoke-
forming open fire involving carbonaceous materials as contained in wood, plastics, gases,
oil products etc. The Fire evaluation process is done by triple Infrared (3Fq) sensor, pro-
tected by a sapphire glass filtering >6.0μm wavelength radiation. Sensor measures the
hot carbon dioxide in a specific flame wavelength; the B and C sensors simultaneously
measure the interference radiation in near wavelengths. This technique together with
intelligent signal processing through microprocessor and custom algorithms, achieves
5200236-00A excellent detection reliability while maintaining the highest immunity to interference
radiation and sunlight.

Manual Call Points


MCP-C (GB) Conventional Manual Call Point for wet space IP24
The MCP-C is a manual call point for indoor environment and is designed for the
Salwico conventional fire alarm systems. Pressing the glass causing it to crack activates
the fire alarm. A protective plastic coating on the glass prevents operator injury. The call
point can be tested with a special key included in the delivery.

5200010-01A

MCP-C WP (GB) Conventional Manual Call Point for wet space IP67
The MCP-C is a manual call point for outdoor environment and is designed for the Sal-
wico conventional fire alarm systems. The selected material PC/ABS and the encapsula-
tion, with ingress protection IP67, makes it very suitable for harsh environment. Pressing
the glass causing it to crack activates the fire alarm. A protective plastic coating on the
glass prevents operator injury. The call point can be tested with a special key included in
the delivery.

5200014-01A

Equipment For Hazardous Areas, Zone 0-1


NS-ISOLATOR Intrinsically Safe Isolator for Conventional IS Loop Units with
NS-AIN1 Address Unit IP55, Max 10 loop units/isol.
NS-ISOLATOR is a Pepperl-Fuchs Type KFD0-CS-Ex1.51P isolator, which is part of the
Salwico conventional intrinsically safe fire detection system. The NS-ISOLATOR barrier
is located in a non-hazardous area (safe area) and forming the interface to IS detectors
and other IS line units. The NS-ISOLATOR does not need a separate power supply. It
is powered directly from the fire alarm panel via the loop/section cables, which means
that no extra cables are needed. The NS-ISOLATOR does not need an earth connec-
tion, and thus routine inspection of earth cable and connections is eliminated. The box
N1770 has knock-out holes on the sides for the three included cable glands. The glands must
be mounted on the short sides of the box as shown in this data sheet

24
Salwico Fire Detection System
ISOLATOR-A Intrinsically Safe Isolator with enclosure for Addressable IS
Loop Units IP55, Max 20 loop units/isol.
ISOLATOR-A is an IS isolator intended for use together with Salwico intrinsically safe
addressable detectors and manual call points. It contains an IS-isolator and a LISA-2
connection board. ISOLATOR-A is located in a non-hazardous area (safe area) and
forming the interface to IS detectors and other IS line units. To each addressable detec-
tor loop a maximum of five ISOLATOR-A units can be connected, each of them accom-
modating up to 20 IS line units. ISOLATOR-A does not need a separate power supply
or earth connection. It is powered directly from the fire alarm panel via the loop cable,
which means that no extra cables are needed. The cable glands shall be mounted acc. to
the dimension drawing on page two. This will guarantee the minimum required distance
(50mm) between the intrinsic safe and the non-intrinsic safe conductors.
N1790

NS-AOHS-IS Analogue Addressable Intrinsically Safe Optical Smoke/Heat

NS-AOHS-IS is an intrinsically safe analogue addressable multi sensor detector for


Salwico fire alarm systems. It has two separate analogue sensor elements. One optical
for smoke detection and one heat-sensing element for heat detection. Alarm condi-
tion is indicated on the detector via a red LED. The LED is lit until the alarm has been
reset on the control panel. The address is set with a DIP switch, which is mounted on
the backside of the detector. NS-AOHS-IS is connected to the detector loop via the
ISOLATOR-A, part. no. N1790. Up to 20 addressable IS units can be connected to one
ISOLATOR-A. It is not possible to connect any remote LED indicator to NS-AOHS-IS.
N11250

EVC-PY-IS Conventional intrinsically Safe Optical Smoke Detector


Salwico EVC-PY-IS is an intrinsically safe Evolution conventional optical smoke detec-
tor. The detector is equipped with an optical sensor with improved sensitivity to black
smoke. The detector is designed for use in areas with high explosion risk. It is connected
to the fire alarm system via an intrinsically safe interface. Salwico EVC-PY-IS must not
be separated from the base when energized. To avoid the possible risk of electrostatic
charge, the unit must not be cleaned with solvents or charged by rubbing.

N1144

HC100/IS Intrinsically Safe Conventional Heat (57°DegC) Detector


The HC100 A2 is an intrinsically safe conventional heat detector for use with all Salwico
Fire Alarm Systems. The detector is designed for use in areas with high explosion risk. It
is connected via an intrinsically safe interface. The heat sensing element is of thermistor
type with a short response time to changes in the ambient temperature. Alarms are
optically indicated until they are reset on the central.

038010

25
Salwico Fire Detection System

ACP-IS Intrinsically Safe Addressable Manual Call Point


for wet space IP67
ACP-IS is an intrinsically safe addressable manual call point for the fire alarm systems
CS3000, CS4000 and NSAC-1. ACP-IS is connected to the detector loop via ISOLA-
TOR-A. Up to 20 addressable IS units can be connected to an ISOLATOR-A. Pressing
the glass causing it to crack activates the fire alarm. The call point can also be tested
with a special key, included in the delivery. A red LED on the front of the call point
indicates the fire alarm. The LED remains lit until the glass has been replaced and the
fire alarm has been reset on the control panel. The address of the call point is set with a
DIP-switch. Clean the manual call point by using a damp cloth.

60060-001010

Equipment For Hazardeous Areas, Zone 2


NS-AOHS-Exn Analogue Addressable Dual Optical Smoke and Heat Detector
for wet space IP55
NS-AOHS-Exn is an analogue addressable multi sensor detector for Salwico fire alarm
systems CS3000*, CS4000 and NSAC-1. It has two separate analogue sensor elements,
one optical for smoke detection and one heat-sensing element for heat detection.
Alarm condition is indicated on the detector via a red LED. The LED is lit until the alarm
has been reset on the control panel. The detector is polarity independent. The address
is set with a DIP switch, which is mounted on the backside of the detector. NS-AOHS-
Exn must not be separated from the base when energized.

N11255

NS-ACPWP-Exn Addressable Manual Call Point for wet space IP67


ACPWP-Exn is a Manual call point for the addressable fire alarm systems CS4000,
NSAC-1 and CS3000 with SPK2000. The selected material PC/ABS and the encapsula-
tion, with ingress protection IP67, make it suitable for very harsh environment. Pressing
the glass causing it to crack activates the fire alarm. The call point can also be tested
with a special key, included in the delivery. A red LED on the front of the call point
indicates the fire alarm. The LED remains lit until the glass has been replaced and the
fire alarm has been reset on the control panel. The address of the call point is set with
a DIP-switch. ACPWP-Exn is polarity independent which simplifies the installation. The
N11320 apparatus must be located in an area with low risk of mechanical danger.

NS-ACP-Exn Addressable Manual Call Point for wet space IP55


The ACP-IP55-Exn is a manual call point for the addressable fire alarm system Salwico
CS4000, CS3000* and NSAC-1.The ingress protection IP55 makes this call point suit-
able for harsh environments. Pressing the glass causing it to crack activates the fire alarm.
A protective plastic coating on the glass prevents operator injury. A red LED is lit on the
call point when the control panel has received the alarm. It will be lit until the glass has
been replaced and the alarm has been reset at the control panel. The address is set with
a DIP-switch mounted inside the call point. The call point is polarity independent. The
apparatus must be located in an area with low risk of mechanical danger.
N11321

26
Salwico Fire Detection System

NS-SCI-Exn, IP55
The SCI-Exn is an analogue addressable short circuit isolator for the NSAC-1, CS3000
and CS4000 fire alarm system. The fire detection loops are divided into fire detection
zones by short circuit isolators. If a short circuit occurs on a loop cable, the zone with
the short circuit is disconnected from the rest of the loop by the SCI units mounted
in the beginning and in the end of the zone. When a short circuit is detected, a yellow
LED on the PCB is lit. The LED is lit until the fault has been remedied and reset at the
control panel. The address is set with a DIP-switch. The SCI-Exn is polarity dependent.

N11890

Base Plates
UB-6 SCI
UB-6 SCI is a low profile detector base for all type of analogue addressable detectors
of EV-Series. The base plate is made for use in dry and clean spaces. The cable entry is
from the center or from the side of the base. UB-6 SCI is developed to provide Short
Circuit Protection in the detector base. Short Circuit Isolator function is fully transpar-
ent and do not require any setting. For more information about other available bases,
see separate document “Base matrix”. The detector base can be used for all Salwico fire
alarm systems. Features and benefits
• Low profile
• Quick and safe Short Circuit Isolation
5200313-00A

SPB-ADAPT SCI
SPB-ADAPT SCI is an adapter for the bases 2IP55 (part no. 046950) and NS-2IP55
(part no. 046900). SPB-ADAPT SCI is developed to provide Short Circuit Protection
in the detector base. Short Circuit Isolator function is fully transparent and do not
require any setting. Smoke, heat and flame detectors can be connected to this adapter.
For more information about suitable bases, see separate document “Base matrix”. The
adapter can be used for all Salwico fire alarm systems. Features and benefits
• Waterproof installation for harsh environment
• Quick and safe Short Circuit Isolation
• Small Firm Factor
5200314-00A

NS-ADAPT-IS, Adaptor for IP-55 base with N1140


The NS-ADAPT-IS is an IS (intrinsically safe) adapter for the base NS-2IP55 (part no.
46900) or 2IP55 (part no. 46950). Only IS-detectors can be connected to this adapter.
The adapter can be used for both addressable and conventional fire alarm systems. The
NS-ADAPT-IS has an IS-label on the side. NB! The classification society might have ad-
ditional installation requirements than what is mentioned in this data sheet.

N1422

27
Salwico Fire Detection System

NS-ADAPT-IS2, Adaptor for IP-55 base with N11250


The ADAPTER AOHS-IS is an adapter for IP55 detector bases. Only detector AOHS-IS
can be connected to this adapter. The adapter can be used for Salwico addressable fire
alarm systems CS3000, CS4000 and NSAC-1. The ADAPTER AOHS-IS has an IS-label
on the side. NB! The classification society might have additional installation requirements
than what is mentioned in this data sheet.

N1430

NS-2IP55, Base plate with cable glands, IP-55


The 2IP55 is a base for all Salwico IP55 detector adapters. Together with the adapters it
is possible to install smoke, heat and flame detectors in harsh
environment with an ingress protection up to IP55. It can be used for both addressable
and conventional fire alarm systems.

046950

EV-SPB-BI Base Adapter with Short Circuit Isolator


Salwico EV-SPB-BI is an Evolution addressable short circuit isolator in an adapter for
watertight bases. It is to be used as an interface for conventional and analogue address-
able fire detectors. EV-SPB-BI is a watertight variant of
base EV-BI. With a conventional detector fitted on the base adapter, the address of the
isolator will be displayed by the system upon fire alarm. Removal
of the detector will also be detected and reported as a fault. The technical address is set
with a special programming tool. Valid addresses are 1-254.

5200098-00A

AC-IR-3Fq Conventional Base for AC-IR-3Fq detector


AC-IR-3Fq Conventional Base is suitable for installation of AC-IR-3Fq Detector in a
harsh environment. The base plate provides ingress protection up to IP67, when lock
screws are used. This base provides a termination possibility, for detector set in conven-
tional mode.
Features
• IP65/IP67 Ingress protection
• Low current draw
• Suitable for installation in harsh environment
• Remote LED Option

5200235-00A

28
Salwico Fire Detection System
AC-IR-3Fq Addressable Base for AC-IR-3Fq detector
AC-IR-3Fq Addressable Base is suitable for installation of AC-IR-3Fq Detector in a harsh
environment. The base plate provides ingress protection up to IP67, when lock screws
are used. The base provides a termination possibility, for detector set in Addressable
mode. The address is set by an 8-way DIP-switch.

Features
• IP65/IP67 Ingress protection
• Low current draw
5200237-00A • Suitable for installation in harsh environment

EC-BASE Detector base for dry spaces IP22


The EC-Base is a low profile base plate for smoke and heat detectors from Salwico EC
range of detectors. It is equipped with an integrated 470 Ohm serial resistor for installa-
tion of EC-type detectors. This detector base is made for use in dry and clean
spaces.

Features:
• Low profile design
• Compatible with all detectors from EC- range
• Tamper resistant feature
5200177-00A • Detector removal detection
• Remote LED Option

EC-ADAPT Detector adapt for wet spaces


The EC-Adapt is a connection adapter with an integrated 470Ohm serial resistor for
installation of EC-type detectors on the IP55 base NS-2IP55 (part no. 46900) or 2IP55
(part no. 46950). This adapter is used for connection of EC-type detectors to the con-
ventional fire alarm system, in an IP55 environment.

5200178-00A

Test equipment
Smoke detector tester
Insert the canister into the smoke dispenser. Lock into place using the screw mecha-
nism. Place the cup over the detector and discharge spray (not more than 1 second)
with a slight upward movement. Repeat this action without removing the cup every 10
seconds for max 1 minute, until the detector is in alarm.

N1738

29
Salwico Fire Detection System

Cordless Heat detector tester kit (recommend)


The Salwico SOLO 461 is a cordless heat detector tester for the Salwico heat detec-
tors. The tester suits point type, rate of rise, fixed temperature and combination detec-
tors up to 90°C. Under the control of a microprocessor, blown air is heated by the
element just before exiting the duct. This minimise the possibility of heat damage the
plastic of the detector. The tester is activated when an infra-red beam is broken by the
detector. For battery charging instruction and general information, see the manual deliv-
ered in the box.

N1743

UV Test lamp EEx ia II CT4


The W8066 Ultraviolet (UV) test lamp is a portable, battery operated source of UV
radiation that is used for periodic testing of ultraviolet flame detectors.
The intrinsically safe device simulates a fire by producing a beam of UV radiation with
the same wavelength as the response range of the UV detectors, enabling the opera-
tor to verify proper system operation without the need for an open flame. The physical
characteristics of the W8066 are comparable to a common flashlight, making it easier to
handle and operate than other test lamps. The test lamp typically actuates a UV detec-
tor at a distance of approximately 10 meters.

001150

UV Test lamp Portable


Salwico UV test lamp is used to perform function test on Salwico UV flame detectors.
Salwico UV test lamp is delivered complete with rechargeable batteries and a battery
charger.

001155

IR Test lamp Incl.rod


The Salwico IR test lamp is used to perform function test on Salwico IR flame detector.
The extension rods packed in a nylon case makes it possible to easily test the detector
in all environments.

001156

30
Salwico Fire Detection System

Testifire 1001-101 Multi Detector Tester for both Smoke/Heat


Testifire is a multi-stimulus detector tester, suitable for testing of optical/photoelectric
and ionisation smoke detectors and thermal detectors (fixed temperature or rateof-
rise). The detectors can be either conventional or analogue addressable. Testifire is also a
functional tester that enables testing of multi-detectors or multi-criteria detectors from
a single test unit. Testifire creates stimuli that the detectors are designed to detect.

5200112-00A

Test equipmane accessories


Testifire Smoke Capsule 6pcs

Testifire generates its non-toxic smoke stimulus from a specially formulated, fluid sup-
plied in a replaceable non pressurised capsule. The number of tests from a capsule is
dictated by the response time of the detectors under test and can range between 500
and 1,000 tests. Although there is much more to the comparison than material cost,
typically this equates to between two and five times that produced by an aerosol.

5200114-00A

Pole Solo 1,2 mtrs / Pole Solo100 1-6 mtrs stronger than 9151
Pole adapter / Pole 1.4 - 4.0 mtrs
The core element of the Solo range is the telescopic and extension access poles which
are extremely lightweight and quickly extend to provide access to detectors up to 9
metres. • Light - easy to use at height, on-site, day after day • Non-whip • Certified
non-conductive - protecting both the engineer and overhead live equipment from inad-
vertent shorts • Available in one, two or four telescopic sections • Lifetime warranty

N1740, N1741
N1744, 009151

Test gas bottle, aerosol, 150 ml, for Solo 330


The professional’s choice - the Solo A3 is a clean synthetic aerosol that delivers parti-
cles replicating those found in real smoke to detector. Provided in a 250ml canister it
is designed for use with the Solo 330 and Solo 332 dispenser. • UL & ULC listed •
Detector manufacturer endorsed • Non-flammable • Oil-free formulation • No
lasting residue • Fast activation and clearing time

009153

31
Salwico Fire Detection System
General Alarm Devices
NS-GA2 General Alarm Push Button Auto/Manual for dry space IP22
The general alarm push button NS-GA2 is designed for use in dry spaces. The NS-GA2
can be wall- or recessed mounted. It is delivered c/w box for wall mounting.
A plastic lid protects it from unintentional activation. NS-GA2 has dual functions:
• Auto: Activates the pre-programmed general alarm pattern. The button will stay ac-
tive until it is pressed again.
• Manual: Activates the audible alarm as long as it is pressed (momentary activation).

N1307

NS-GA2/IP55 General Alarm Push Button Auto/Manual


for wet space IP55
The general alarm push button NS-GA2/IP55 is designed for use in harsh environments.
The NS-GA2/IP55 is wall mounted and a plastic lid protects it from unintentional activa-
tion.
NS-GA2/IP55 has dual functions:
• Auto: Activates the pre-programmed general alarm pattern. The button will stay active
until it is pressed again.
• Manual: Activates the audible alarm as long as it is pressed (momentary activation).
NS-GA2/IP55 is delivered c/w two cable glands.
N1308

Bells
MBA6, alarm bell
Salwico MBA-6 alarm bell is intended for use with all Salwico fire alarm systems. The
Salwico MBA-6 has a very high volume output matched with extremely low power
consumption. The specially designed weatherproof bell has an aluminium back box with
a built-in 230Vac to 24 Vdc weatherproof mains pack (BBX-4) that allows the bell to be
powered directly from a mains supply.
The back box is given either single or double treaded for maximum flexibility in installa-
tion.

006143 6”, red, 230VAC


006144 8”, red, 230VAC

BBX, conn. box, for 6131-34, IP65


The fire alarm bells are suitable for both indoor and outdoor uses since the bells have
aluminium/plastic housings. The operating part of BE12–BE13 is a micro-motor and of
BE14–BE17 a two coil vibrator. All versions have low starting currents and very low
power consumption. If used in harsh environment the waterproof connection box
BE10, IP65, shall be used.

006135

32
Salwico Fire Detection System

Bell El. 6” 24VDC IP33 RED (MED)


A unique, patented alarm bell designed for use in fire, security and other signalling
systems. The combination of a miniature solenoid with an integrated control circuit al-
lows excellent sound coverage, minimum current consumption and increased reliability.
The improved aesthetics make the bell suitable for all applications including the most
prestigious locations.

5100462-00A

Bell El. 6” 230VAC IP33 RED


A unique, patented alarm bell designed for use in fire, security and other signalling
systems. The combination of a miniature solenoid with an integrated control circuit al-
lows excellent sound coverage, minimum current consumption and increased reliability.
The improved aesthetics make the bell suitable for all applications including the most
prestigious locations.

5100463-00A

Sounders
Siren 24 VDC
This sounder can be connected to all Salwico fire alarm systems. It has a range of
32 tones which is set by a DIP switch. It is also equipped with a volume control. The
sounder is pre-set to tone no. 14 (970 Hz, 101 dBA at 1 m). A second tone is available,
which can be switched in by the connection of a third core to the siren. The volume
control switch will provide two settings, either full output or an attenuation of
10dB. Features: • 102 dB(A) sound output • 32 tones (user selectable) • Volume
control • Two stage alarm • Automatic synchronisation • Lockable base • Suitable for
outdoor use
5100441-00A IP65 White MED
5100444-00A IP65 Red MED
5100445-00A IP66 Red MED

NS-ES, electronic siren, 24VDC, IP66, red.


The NS-ES/IP66 is a low profile Benshee MT siren for fire and security alarm instal-
lations in harsh environments. The siren is delivered with two cable glands for cable
diameters ranging from Ø8 to Ø13 mm. The base has two knockout holes for the cable
glands. A sound selector for 32 user selectable tones and a volume control is fitted
inside the sounder. Recommended tone: No. 7, continuous at 950 Hz, 103 dBA, 12 mA.

N1525

33
Salwico Fire Detection System

DB3V02BR, alarm Siren/bell, Ex-proof, 24 VDC


DB3V is a lightweight, flameproof sounder intended for use in potentially explosive
atmospheres. DB3 has been designed with high ingress protection to withstand harsh
environmental conditions. The flame paths, flare and body are manufactured completely
from UV stable glass reinforced polyester. Stainless steel screws and sinter are incorpo-
rated thus ensuring a corrosion free product. DB3V has a pre-programmed bell-tone
and integral volume control. DB3V is delivered without cable glands. DB3 fulfils the
following requirements:
• Eexde IIC T5 • ATEX, Ex II 2GD • BASEEFA certified
006255 DB3V is also available in GOST “R” & “K”, Chinese (CQST), Australian (SAA) and UL
models.

MKTV-75/800 typhoon
The pneumatic alarm typhoons in the KTV and MKTV series are a maintenance free,
light, rigid and powerful signalling apparatus for different applications on board ships. The
typhoons can be delivered as a complete unit or the horn and the solenoid valve as
separate units (see separate datasheet). For distinct signals, the piping
length between the valve and the horn should not exceed 6m. The horn is delivered
with wall bracket and filter. For explosive, corrosive or very hot areas the solenoid
valves shall be mounted separately outside the exposed area. The solenoid valve is
delivered with filter and fittings for copper piping with Ø 10 mm OD. The solenoid valve
should not be placed outdoor without protective cover.
006305 24 VDC, 800Hz
006306 230 VAC, 800Hz

MKT-75/800 Typhoon without mag.valv. 800Hz


A penetrating sound means a sound capable of reaching a listener on a distant vessel
under normal noise conditions. From this respect, it is not only the sound pressure level
that is the important factor, but the content of appropriate frequency components in
the signal. This simple fact tells us that apart from the formal demand on the whistle -
having a sufficiently strong component within one 1/3 octave band (IMO regulations)
- there are other important factors too. The MKT-75/800 Typhoon have an efficient
sound spectrum fulfilling the highest demands - on vessels as well as in a great many civil
006312 defence and disaster alarm stations on land.

Multitone sound disc, mounted below UB-6


Salwico 4800 fire alarm annunciator is specially made to fit between the UB-1 or B-2
fire detector base and the ceiling. The annunciator is 24 Vdc powered from the cen-
tral or from a local control unit like CM22 or CM44. Salwico 4800 provides acoustical
alarms either in case dedicated annunciators are to be fitted for the fire alarm system,
or when it is required to have a local annunciator which completes the existing PA/
GA alarm system. Salwico 4800 contains an electronic sound generator which allows
choosing between 2 different tones, which complies with the various standards in use
worldwide. By feeding the Salwico 4800 through a third wire, it is possible to activate
an alternative sound to the one programmed, in way to get two different alarm tones,
005303 depending on the case. Volume adjustment is possible by an internal control, in order to
set the desired sound pressure.

34
Salwico Fire Detection System
Lights
830, flash light, red, 230VAC, IP65
Salwico 830 is a flash light suitable for installation in harsh environments. Salwico 830 is
easy to install and has a long life time. Wall brackets and other colours on the lens and
are available upon request.

006502

SUE-9412A-1, flash light, red, 230VAC, Eexd IIBT4


The SUE9412A-1 is a series of EX classified flash lights designed for use in very harsh
environments, for example pump rooms on vessels.

006545

SOLEX flashlight 24 VDC red MED


This flashlight can be connected to all Salwico fire alarm systems. It is an electronic flash-
light with low power consumption, small dimensions and easy to install. Solex flashlights
are cost effective compliment to audible alarms for use in areas of high ambient
noise. Features:
• Wide operating voltage, 9-60 VDC
• Constant performance over voltage range
• Automatic synchronisation
• Lockable base
• Tamper switch option
5100443-00A • Suitable for outdoor use

828, flash light


Salwico 828 is a modern designed flashlight suitable for installation in harsh environ-
ments. Salwico 828 is easy to install and has a long lifetime. Tools are required to dis-
mount the lens, which prevents sabotage. For installation on walls, use the separate wall
bracket part number 6514.

006512 Red, 24VDC, IP65


5200073-00A Green, 24VDC, IP65

35
Salwico Fire Detection System
Combined Sounders and Lights
Horn w. Red Rot. Light 230V Exd IIC T6
Heavy Duty Product of High Durability
• Signal sound built-in product of direct mounting type with bulb revolving warning
light and horn integrated.
• Employing aluminum housing with high durability and high anti-corrosion.
• Possible to select sound tone and control volume by using built-in sound tone
switch and volume controller.
• RPM : 120~140RPM(Controllable)
• Volume : MAX.118dB/m
5200117-00A • Protection Class : IP56

FLASHNI, Sounder & beacon, 32 tones, IP65


Flashni is a compact combination of a high output sounder and beacon for spaces
requiring both audible and visual indication of alarms. The ingress protection IP65 makes
it suitable for installation in harsh environment. The sounder can be set to 32 differ-
ent tones. The tones are set with a DIP switch inside the unit. It is also equipped with a
volume control.

N1546

Siren beacon 24 VDC IP65 red MED


This unit is a compact combination of a high output sounder and beacon for spaces
requiring both audible and visual indication of alarms. It can be connected to all Salwico
fire alarm systems. The ingress protection IP65 makes it suitable for installation in harsh
environment. The sounder can be set to 32 different tones. The tones are set with a DIP
switch inside the unit. It is also equipped with a volume control.
Features:
• Up to 103dB(A) with built in Xenon flash
• Automatic sounder synchronisation
• Improved tone clarity, reducing confusion
5100442-00A

Door Control Accessories


GP721T+722, Door Holder Magnet, 200 kP, 24 V DC, with push button
The magnetic door holder consists of two parts, a door holder magnet, which is mount-
ed on the wall, and an armature, which is mounted on the door. The door will be held
open as long as the current to the magnet is on. By breaking the current the magnet
will release its grip and a normal door closer closes the door.

007112

36
Salwico Fire Detection System

NS-DRP, Door Release, wall mounted WT, IP-55


This door release switch is made for harsh environments that require ingress protection
up to IP55. The switch is not spring loaded. Therefore it will stay in closed position until
it is manually set to open position.

N1781

NS-DRW, Fire Door Release Button, wall mounting


This door release switch is made for wall mounting in dry areas where recessed mount-
ing is not possible. The switch is not spring loaded. Therefore it will stay in
closed position until it is manually set to open position.

N1779

NS-DRC, Door Release Button, recessed


This door release switch is made for recessed wall mounting in dry areas. It can be
mounted in a recessed mounting box with a diameter ranging from 58 - 68 mm.
The switch is not spring loaded. Therefore it will stay in closed position until it is manu-
ally set to open position.

N1780

Ventilation duct adapter


Calectro UG-3-NS-AOS (for EV-P), vent. duct adapter excl. tube and head
UG-3 has been developed to detect smoke in ventilation ducts and combines a smoke
detector and an adapter system, where both tube and housing are specially designed for
optimum airflow through the smoke detector. The system meets all the requirements
for safe fire detection with airflow speeds from 0.2 m/s to 20 m/s. Since the UG-3 is
used with different types of fire alarm systems and installations it is delivered without:
• Venturi pipe • Detector
The UG-3 is made for rectangular ducts. The optional UG-MB Mounting bracket has to
be used if the UG-3 should be mounted on insulated or circular ducts. A test hole on
the UG-3 cover makes it easy to test the smoke detector. Simply remove the plastic
5200228-00A
plug and spray test gas into the UG-3.

37
Salwico Fire Detection System

Calectro UG-3-O (for DOS3), vent. duct adapter excl. tube and head
UG-3 has been developed to detect smoke in ventilation ducts and combines a smoke
detector and an adapter system, where both tube and housing are specially designed for
optimum airflow through the smoke detector. The system meets all the requirements
for safe fire detection with airflow speeds from 0.2 m/s to 20 m/s. Since the UG-3 is
used with different types of fire alarm systems and installations it is delivered without:
• Venturi pipe • Detector
The UG-3 is made for rectangular ducts. The optional UG-MB Mounting bracket has to
be used if the UG-3 should be mounted on insulated or circular ducts. A test hole on
the UG-3 cover makes it easy to test the smoke detector. Simply remove the plastic
5200239-00A
plug and spray test gas into the UG-3.

Calectro Pipe
Part no: 5200225-00A Calectro VR-0.6M Pipe, for ducts <600 mm
Part no: 5200226-00A Calectro VR-1.5M Pipe, for ducts <1500 mm
Part no: 5200227-00A Calectro VR-2.8M Pipe, for ducts <2800 mm

5200225-00A
5200226-00A
5200227-00A

Calectro UG-MB Mounting Bracket


Mounting bracket for Uniguard Superflow, UG-3/4 models
• Easily adapted by hand
• Quick assembly

5200229-00A

38
Salwico Fire Detection System
SIL 2 certified modules
CS-SAFETY M H
The CS-Safety M module is an interface module and data collector for all CS-Loop
M modules in a Fire Detection System designed to comply with the standards for the
industrial-, maritime-, offshore- and rolling stock markets up to Safety Integrity Level
2 (SIL-2). CS-Safety M supports both single and redundant setup. (CS-Safety M does
not support a redundant train solution since it’s not allowed to extend the CAN-bus
outside of the cabinet.)

5210001-00A

CS-LOOP M H
The CS-Loop M H module is intended to be used as a part of a fire detection system
and is suitable for use in SIL 1 and SIL 2 environments. This loop-line controller module
offers one loop-line interface that is capable of handling 150 addressable loop units. It is
designed to comply with the standards for the industrial, maritime, offshore and rolling
stock markets up to Safety Integrity Level 2 (SIL 2).

5210003-00A

CS-PYH
The CS-PYH is an addressable combined optical smoke and heat detector suitable for
use in SIL 1 and SIL 2 environments. It is designed to comply with the standards for the
industrial, maritime, offshore and rolling stock markets up to Safety Integrity Level 2 (SIL
2). The detector has an output for remote indication in form of a remote LED or a local
sounder.

5210020-00A

CS-MCP
The CS-MCP is an addressable manual call-point designed for installation in-doors. A fire
alarm is activated by breaking the glass that has a protective plastic coating to
preventing operator injury. A LED on the front of the call-point indicates activation of
the fire alarm and the LED remains lit until the fire alarm has been reset on the fire
alarm panel of the Fire Detection System (FDS). The CS-MCP is designed to comply
with the standards for the industrial-, maritime-, offshore- and rolling stock markets up
to Safety Integrity Level 2 (SIL-2).

5210030-00A

39
Salwico Fire Detection System

CS-MCP WP
The CS-MCP WP is an addressable manual call-point. The selected material and the
encapsulation, with ingress protection IP67, makes it suitable for harsh environment.
A fire alarm is activated by breaking the glass that has a protective plastic coating to
preventing operator injury. A LED on the front of the call-point indicates activation of
the fire alarm and the LED remains lit until the fire alarm has been reset on the fire
alarm panel of the Fire Detection System (FDS). The CS-MCP WP is designed to
comply with the standards for the industrial-, maritime-, offshore- and rolling stock
markets up to Safety Integrity Level 2 (SIL-2).

5210031-00A

CS-MCP HD
The CS-MCP HD is an addressable manual call-point. The heavy duty encapsulation,
with high level of corrosion resistance, makes it capable of withstanding harsh environ-
ment for long time periods. A fire alarm is activated by breaking the glass that has a pro-
tective plastic coating to preventing operator injury. A LED on the front of the call-point
indicates activation of the fire alarm and the LED remains lit until the fire alarm has
been reset on the fire alarm panel of the Fire Detection System (FDS). The CS-MCP
HD is designed to comply with the standards for the industrial-, maritime-, offshore- and
rolling stock markets up to Safety Integrity Level 2 (SIL-2).
5210032-00A CS-MCP HD RED
5210062-00A CS-MCP HD BLUE
5210063-00A CS-MCP HD GREEN
5210064-00A CS-MCP HD YELLOW
5210065-00A CS-MCP HD YELLOW/BLACK

CS-Adapt
Detector base adapter CS-ADAPT is designed to protect the loop-line connection of
the detector from water ingression according to IP55. The CS-ADAPT is an adapter for
2IP55 detector bases.

5210040-00A

CS-IC10 WP
The CS-IC10 WP is an input unit for various integration of safety inputs. It has been
designed for use in harsh environments and to comply with the standards for the
industrial, maritime, offshore and rolling stock markets up to Safety Integrity Level 2
(SIL 2). The CS-IC10 WP has one input that can be connected to external equipment
with a dry relay contact. The CS-IC10 WP supervises the cable to the external equip-
ment for cable break and short circuit, and the input can be configured as active
high or active low.

5210060-00A

40
Salwico Fire Detection System

CS-IC22 WP
The CS-IC22 WP is an input and output unit for various integration of safety inputs/
outputs. It has been designed for use in harsh environments and to comply with the
standards for the industrial, maritime, offshore and rolling stock markets up to Safety
Integrity Level 2 (SIL 2). The CS-IC22 WP has two inputs that can be connected to
external equipment with a dry relay contact. The CS-IC22 WP supervises the cable to
the external equipment for cable break and short circuit, and the inputs can be config-
ured as active high or active low.

5210061-00A

CS-IC10 SS WP
The CS-IC10 SS WP is an input unit for various integration of safety inputs. It has been
designed for use in harsh and corrosive environments and to comply with the standards
for the industrial, maritime, offshore and rolling stock markets up to Safety Integrity
Level 2 (SIL 2). The CS-IC10 SS WP has one input that can be connected to external
equipment with a dry relay contact. The CS-IC10 SS WP supervises the cable to the
external equipment for cable break and short circuit, and the input can be configured as
active high or active low.

5210066-00A

CS-IC22 SS WP
The CS-IC22 SS WP is an input and output unit for various integration of safety inputs/
outputs. It has been designed for use in harsh and corrosive environments and to
comply with the standards for the industrial, maritime, offshore and rolling stock
markets up to Safety Integrity Level 2 (SIL 2). The CS-IC22 SS WP has two inputs that
can be connected to external equipment with a dry relay contact. The CS-IC22 WP
supervises the cable to the external equipment for cable break and short circuit, and
the inputs can be configured as active high or active low.

5210067-00A

CS-CABINET S 300X380X155
CS-CABINET S is designed to contain the modules of a SIL-classed fire detection
system in one single cabinet together with a display & control panel, suitable for
offshore and marine installations.

5210070-00A

41
Salwico Fire Detection System

CS-CABINET L 700X500X250
CS-CABINET L is designed to contain the modules of a SIL-classed fire detection sys-
tem in one single cabinet together with a display & control panel, suitable for offshore
and marine installations.

5210072-00A

CS-Isolator
The CS-Isolator is an intrinsically safe isolator intended for use together with intrinsically
safe addressable loop units. It has been designed to comply with the standards for the
industrial, maritime, offshore and rolling stock markets up to Safety Integrity Level 2 (SIL
2). This unit is used to power feed the Ex loop-line with reduced voltage and reduced
available power and also allow IDAxt communication to/from the Ex loop units.

5210050-00A

CS-PSH Ex
The CS-PH Ex is an intrinsically safe addressable combined optical smoke and heat
detector suitable for use in SIL 1 and SIL 2 environments. It is designed to comply with
the standards for the industrial, maritime, offshore and rolling stock markets up to Safety
Integrity Level 2 (SIL 2). The detector is equipped with two LED indicators giving clear
visibility of the red local alarm indication.

5210021-00A

CS-MCP WP Ex
The CS-MCP WP Ex is an intrinsically safe addressable manual call point. The selected
material and the encapsulation, with ingress protection IP67, makes it very suitable for
harsh environment. A fire alarm is activated by breaking the glass that has a protective
plastic coating to prevent operator injury. A LED on the front of the call point indicates
activation of the fire alarm and the LED remains lit until the broken glass has been
replaced and the fire alarm has been reset on the control panel of the fire detection
system. The CS-MCP WP Ex is designed to comply with the standards for the industrial,
maritime, offshore and rolling stock

5210034-00A

42
Salwico Fire Detection System

CS-IC10 WP Ex
The CS-IC10 WP Ex is an intrinsically safe input unit for various integration of safety
inputs. It has been designed for use in harsh environments and to comply with the
standards for the industrial, maritime, offshore and rolling stock markets up to Safety
Integrity Level 2 (SIL 2). The CS-IC10 WP Ex has one input that can be connected to
external equipment with a dry relay contact. The CS-IC10 WP Ex supervises the cable
to the external equipment for cable break and short circuit, and the input can be config-
ured as active high or active low.

5210080-00A

CS-Adapt Ex
Detector base adapter CS-ADAPT Ex is designed to protect the loop-line connection
of the detector from water ingression according to IP55 in Ex environment. The
CS-ADAPT Ex is an adapter for 2IP55 detector bases.

5210041-00A

CS-MCP HD Ex
CS-MCP HD Ex is an intrinsically safe addressable manual call point. The heavy duty
encapsulation, with high level of corrosion resistance, makes it capable of withstanding
harsh environment for long time periods. A fire alarm is activated by breaking the glass
that has a protective plastic coating to prevent operator injury. The fire alarm can be
reset on the control panel of the fire detection system after the broken glass has been
replaced. CS-MCP HD Ex is designed to comply with the standards for the industrial,
maritime, offshore and rolling stock
5210033-00A CS-MCP HD Ex RED
5210081-00A CS-MCP HD Ex BLUE
5210082-00A CS-MCP HD Ex GREEN
5210083-00A CS-MCP HD Ex YELLOW
5210084-00A CS-MCP HD Ex YELLOW/BLACK

43
Salwico Gas Detection System

Salwico
Gas
Detection
System

44
Salwico Gas Detection System
Standard Centrals
Salwico GS5000
This Gas detection system is a state-of-the-art addressable detection system designed
to meet marine, industrial and transport requirements. Special care is given to ergo-
nomics and user-friendliness with its logical and intuitive operator panel. These standard
centrals are designed for small stationary gas detection installations for the monitoring
of explosive and/or toxic gases. Salwico Gas Detection System is SOLAS compliant and
certified by all major classification societies for marine applications.

GDS I-1A These standard systems are available in the following different variations
GDS I-2A 1 x Control panel, Internal
GDS I-3A 1 x Isolated serial interface RS485 (NMEA 0183, MODBUS RTU)
GDS I-1A1R 5-15 x Relay outputs (one for fault and one for gas A1, 3-13pcs programmable relays)
GDS I-2A1R 4-12 x 4-20mA inputs for connection of gas detectors
GDS I-3A1R 0-1 x Serial interface RS485/RS422
GDS I-1A1C 0-1 x Serial interface RS232
GDS I-2A1C 1 x 2,5A or 4,2A Power supply, 100-240VAC
GDS I-3A1C
GDS I-1A1C1R For detailed information see datasheet.
GDS I-2A1C1R
GDS I-3A1C1R

Note: Custom made centrals is available on request

The Salwico Gas Detection System can also accommondate larger gas detection installations on request such as LNG
vessel, FPSO:s, Drill ships etc. These systems will be tailor made for its application.

Individual modules for custom made centrals


Control M Gas Internal
The Control M Gas is a control panel with a 4.3” graphical colour display used to
manage and supervise a gas alarm system. Control M Gas Internal mounts in the gas
alarm cabinet front. Control M Gas Internal is equipped with communication buses for
connecting to the gas alarm system, but it has to be used in connection with module
BusCon M Gas. Features: • A backlit 4.3” graphical colour display • Alarm buzzer
• LED status indicators • Backbone Bus Interface • MODBUS interface
• USB interface (for service & maintenance) • One power output
• One alarm output • One fault output • Three programmable outputs

5110001-00A

45
Salwico Gas Detection System

Control M X
Control M X is used as a provider of additional communication channels, additional
external communication,
or as an extension bus.
A Control M X provides the following features:
• Ethernet connection
• RS-422/RS-485 interface
• RS-232/RS-485 interface
• Two programmable relay outputs
5100002-01A

Buscon M Gas
The BusCon M Gas is a connection module for the Salwico Gas Detection System. This
module provides electric isolation for the system and backbone extension for module
Control M Gas, as well as monitors the supply voltage and the Xgas signal. The BusCon
M Gas has a 20-pin flat cable connector with extended BBI interface for connection
with a Control M Gas module.

5103002-00A

Analogue M 4-20
The Analogue M 4-20 is a transmitter module for a gas alarm system. This module pro-
vides four transmitter interfaces (4-20 mA inputs):
• 2-wire • 3-wire, current source • 3-wire, current sink • 4-wire
In order to avoid a massive start-up current in the system the Analogue M 4-20 module
delays the voltage output (+, SG) in the transmitter interfaces upon start-up:
• Transmitter interface 1, 0 ± 10 ms
• Transmitter interface 2, 125 ± 10 ms
• Transmitter interface 3, 250 ± 10 ms
• Transmitter interface 4, 375 ± 10 ms
5103003-00A

Power Boost M
The Power Boost M is designed to distribute power and supervise connections in a
gas alarm system. This module can supply: • Centralized power through a Power Boost
Loop, which is secured against interruption and short circuit. • Compensation for volt-
age drop in the cable for distributed modules in gas alarm systems • Transfer of xGas
status between the Power Boost modules on a Power Boost Loop and the system
modules connected to the Power Boost module on the internal Backbone Bus (BBI)
• External Backbone Bus (BBE) PB-485 communication between system modules. •
Protection of the External Backbone Bus (BBE) PB-485 communication between mod-
ules against interruptions and short circuits. • Supervise the 48 VDC and the PbxGas
5103004-00A
signals (on the Power Boost Loop). • Transform External Backbone Bus (BBE) PB-485
to Internal Backbone Bus (BBI) RS-485.
46
Salwico Gas Detection System

Surge Prot M
Surge Prot has 3 major functions:
• Surge protected power inputs for the Backbone Bus Internal, BBI.
• Terminal board for Backbone Bus External, BBE (RS485 Repeater).
• Electronic short circuit protected outputs for Control or Repeater panels.
Note! This output is not supervised. These functions can be used together or individu-
ally. The module is designed to be used where there are no requirements for electrical
isolation between devices. NOTE! The module has built-in terminators for BBI and BBE.
See section RS485 Termination for more information.
5100420-00A

Bus Isolator M
Bus Isolator M divides the system backbone bus into segments. Its dual functionality
isolates communications and basic backup signals between the stretched system parts
and provides power to the control panel (e.g. Control M Gas).

5100071-01A

Relay M 8
Relay M 8 provides eight programmable relay contacts. Each of these relay contacts pro-
vide a potential free change-over contact. Use Relay M 8 to control units such as sirens,
magnets, flashlight, alarms and ventilation fans.

5100081-01A

PSU M ACDC 5A
PSU M AC/DC 5A is a marine approved power supply that powers the system. It is
short-circuiting proof and can be used in pairs to supply 5+5 A or 48VDC.

5100087-01A

47
Salwico Gas Detection System
Control/Repeater Panels
Control M Gas External
The Control M Gas is a control panel with a 4.3” graphical colour display used to man-
age and supervise a gas alarm system either as a external control or repeater panel.
Control M Gas External can be mounted on any flat surface or flush mounted, inde-
pendently from a gas alarm cabinet. Control M Gas External is equipped with commu-
nication buses for connecting to the system via BBE interface RS-485 or BBE interface
PB-485. Features: • A backlit 4.3” graphical colour display • Alarm buzzer
• LED status indicators • Backbone Bus Interface RS-485 • Backbone Bus Interface
PB-485 (Power Boost loop) • USB interface (for service & maintenance) • Two con-
figurable inputs • Three programmable outputs
5103001-00A

Log Printer
Serial Printer Epson LX300+II
Because of its compact dimensions, the Epson LX-300+II are the ideal 9-pin printer for
applications where space is limited and also a low cost solution for measurement and
control systems. With auto switching USB, serial and parallel interfaces the LX-300+II
provide flexible standalone connectivity.

5200306-00A

Power Boost Loop units & Gas Detectors


Sensor Interface Cabinets
The Sensor Interface Cabinet is an interface unit for 1 to 8pcs of gas detectors. It is
intended for use with Salwico Gas Detection System and can interface with gas detec-
tors with a 4-20mA transmitter interface. The Salwico SIC is connected to the power
boost loop and will accommodate up to eight analogue inputs for gas detectors at the
local area instead of the main central. The advantage with this is that the cables will be
monitored for breaks and short circuits, it will also save lots of installation costs due to
shorter cables. The unit continuously monitors the gas detector for gas alarms, faults and
also checks the supply voltage of the detector interface.

The Sensor Interface Cabinets are available in the following variants.


SIC-1A Sensor Interface Cabinet with 4 analogue inputs for detectors
SIC-2A Sensor Interface Cabinet with 8 analogue inputs for detectors
SIC-1A1R Sensor Interface Cabinet with 4 analogue inputs for detectors and 8 programmable dry
relay contacts
SIC-1A1C Sensor Interface Cabinet with 4 analogue inputs for detectors and 1 RS485 serial inter-
face
SIC-1C Sensor Interface Cabinet with 1 RS485 serial interface
SIC-1R Sensor Interface Cabinet with 8 programmable dry relay contacts
SIC-2R Sensor Interface Cabinet with 16 programmable dry relay contacts

For detailed information see datasheet.

48
Salwico Gas Detection System
Gas Detecors
Salwico GD
The Salwico GD range of gas detectors is used to monitor areas where flammable, oxy-
gen deficiency and toxic gases may pose a hazard environment. The Salwico GD uses a
number of sensor technologies including catalytic bead, electrochemical cell and Non-
dispersed (NDIR). Salwico GD has a long list of user friendly features:
• One hand operation for sensor replacement
• Clear multi-function backlit display
• Tri-colour backlight display for status indication
• 4-20 mA signal output
• 3 Switch relays
• Modbus
• EX-d approved

The Salwico GD range gas detectors are available in the following variants.
5200260-01A Salwico GD CAT HC 0-100%LEL HYDROCARBON, CATALYTIC, ALUMINIUM AL-
LOY, M20 ENTRY
5200260-02A Salwico GD NDIR CH4 0-100%LEL METHANE, NDIR, ALUMINIUM ALLOY; M20
ENTRY
5200260-03A Salwico GD NDIR C3H8 0-100%LEL PROPANE, NDIR, ALUMINIUM ALLOY, M20
ENTRY
5200260-04A Salwico GD NDIR CO2 0-2%VOL CARBON DIOXIDE, NDIR, ALUMINIUM ALLOY,
M20 ENTRY
5200261-01A Salwico GD EC O2 0-25%VOL OXYGEN, ELECTRO CHEMICAL, ALUMINIUM AL-
LOY, M20 ENTRY
5200262-01A Salwico GD EC H2S 0-50 PPM HYDROGEN SULPHIDE, ELECTRO CHEMICAL, ALU-
MINIUM ALLOY
5200262-02A Salwico GD EC CO 0-250 PPM CARBON MONOXIDE, ELECTRO CHEMICAL, ALU-
MINIUM ALLOY
5200262-03A Salwico GD EC H2 0-1000 PPM HYDROGEN, ELECTRO CHEMICAL, ALUMINIUM
ALLOY

Salwico GD WH TRUE IR
The Salwico GD TRUE IR gas detector is a point detector for gas concentration moni-
toring potentially hazardous environment. The Salwico GD TRUE IR is based on infrared
absorption. Solid state design improves reliability, long-term stability and accuracy in
continuous measurement of gas concentrations in ambient air. Compared with catalytic
sensors the Salwico GD TRUE IR has the following advantages:
• Proven high reliability and long term stability results in low test frequency and no
calibration cost. • Automatic self-test • Failure will not give gas alarm • Presence of
oxygen is not required during equipment life time • Immunity to poisoning from H2S,
silicone and other agents • No saturation effects from high gas concentrations • The
gas flow rate has no influence on accuracy • Several different mounting possibilities

Special junction boxes or duct mounting brackets are available upon request.

The Salwico true IR hart gas detectors are available in the following variants.
5200138-00A Salwico GD WH TRUE IR C3H8
5200138-01A Salwico GD WH TRUE IR CH4

49
Salwico Gas Detection System

Gas Detectors suitable for harch environments


Salwico GD in 316 stainless steel inclosure
The Salwico GD range of gas detectors is used to monitor areas where flammable, oxy-
gen deficiency and toxic gases may pose a hazard environment. The Salwico GD uses a
number of sensor technologies including catalytic bead, electrochemical cell and Non-
dispersed (NDIR). Salwico GD has a long list of user friendly features:
• One hand operation for sensor replacement
• Clear multi-function backlit display
• Tri-colour backlight display for status indication
• 4-20 mA signal output
• 3 Switch relays
• Modbus
• EX-d approved
The Salwico GD range gas detectors are available in the following variants.
5201095-00A Salwico GD CAT HC SS 0-100%LEL HYDROCARBON, CATALYTIC, 316 STAINLESS
STEEL, M20 ENTRY

5201098-00A Salwico GD NDIR CO2 SS 0-2%VOL CARBON DIOXIDE, NDIR, 316 STAINLESS
STEEL, M20 ENTRY

5201099-00A Salwico GD EC O2 SS 0-25%VOL OXYGEN, ELECTRO CHEMICAL, 316 STAINLESS


STEEL, M20 ENTRY

5201100-00A Salwico GD EC H2S SS 0-50 PPM HYDROGEN SULPHIDE, ELECTRO CHEMICAL,


316 STAINLESS STEEL, M20 ENTRY

5201101-00A Salwico GD EC CO SS 0-250 PPM CARBON MONOXIDE, ELECTRO CHEMICAL,


316 STAINLESS STEEL, M20 ENTRY

5201102-00A Salwico GD EC H2 SS 0-1000 PPM HYDROGEN, ELECTRO CHEMICAL, 316


STAINLESS STEEL, M20 ENTRY

50
Salwico Gas Detection System

Salwico GD SS HART
The Salwico GD SS HART range of gas detectors is used to monitor areas where flam-
mable, oxygen deficiency and toxic gases may pose a hazard environment. The Salwico
GD SS HART uses a number of sensor technologies including catalytic bead and elec-
trochemical cell. The stainless steel enclosure makes it suitable for harsh environments.
Salwico GD SS HART has a long list of user friendly features:
• One hand operation for sensor replacement
• Clear multi-function backlit display
• 4-20 mA signal output
• 3 Switch relays
• HART

The Salwico GD range gas detectors are available in the following variants.
5201089-00A Salwico GD CAT HC SS W HART 0-100%LEL HYDROCARBON, CATALYTIC, SS,
M20 ENTRY, HART

5201090-00A Salwico GD EC O2 SS W HART 0-25%VOLOXYGEN, ELECTRO CHEMICAL, SS, M20


ENTRY,HART

5201091-00A Salwico SAL GD EC H2S SS W HART 0-50 PPM HYDROGEN SULPHIDE, EC, SS,
M20 ENTRY, HART

5201092-00A Salwico GD EC CO SS W HART 0-250 PPM CARBON MONOXIDE, EC, SS, M20
ENTRY, HART

5201093-00A Salwico GD EC H2 SS W HART 0-1000 PPM HYDROGEN, EC, SS, M20 ENTRY,
HART

Salwico GDTRUE IR HART


The Salwico GD TRUE IR gas detector is a point detector for gas concentration moni-
toring potentially hazardous environment. The Salwico GD TRUE IR is based on infrared
absorption. Solid state design improves reliability, long-term stability and accuracy in
continuous measurement of gas concentrations in ambient air. Compared with catalytic
sensors the Salwico GD TRUE IR has the following advantages:• Proven high reliability
and long term stability esults in low test frequency and no calibration
cost • Automatic self test • Failure will not give gas alarm • Presence of oxygen is not
required during equipment life time • Immunity to poisoning from H2S, silicone and
other agents • No saturation effects from high gas concentrations • The gas flow rate
has no influence on accuracy • Several different mounting possibilities

Special junction boxes or duct mounting brackets are available upon request.

The Salwico true IR hart gas detectors are available in the following variants.
5201087-00A Salwico GD WH TRUE IR C3H8 W HART

5201088-00A Salwico GD WH TRUE IR CH4 W HART

51
Salwico Gas Detection System
Open path gas detectors
Salwico GD OPEN PATH HC, gas detector complete unit,
range 4-20 m.
The Salwico GD Open Path gas detector is a point detector for gas concentration
monitoring in potentially hazardous environments. The Salwico GD Open Path is based
on infrared absorption. Solid state design improves reliability, long-term
stability and accuracy in continuous measurement of gas concentrations in ambient air.
Why open path gas detection? Open path detectors complement the use of individual
point detectors and offer many significant benefits including: • Wider area coverage
- most likely to pick up any leak • Very high speed of response • NO unrevealed
failure modes - no possibility of blocked gas path to detector • Detector location not
5201054-00A as critical • Indicates size of hazard

Moore types of gas detectors are available on request

Duct Mounting kits


Duct mounting kit for Salwico GD 5200260-262, 100mm in diameter

Circular type of Duct mounting kit for the following gas detectors:
5200260-01A Salwico GD CAT HC, Catalytic gas detector, Hydro Carbon gases (HC), 0-100% LEL
Salwico GD NDIR CH4, Non Dispersive gas detector, Methane gases (CH4),
5200260-02A 0-100% LEL
Salwico GD NDIR C3H8, Non Dispersive gas detector, Propane gases (C3H8),
5200260-03A 0-100% LEL
Salwico GD NDIR C02, Non Dispersive gas detector, Carbon Dioxide gases (CO2),
5200260-04A 0-2% VOL
Salwico GD EC O2, Electrochemical gas detector, Oxygen (O2), 0-25% VOL
5200261-01A Salwico GS EC CO, Electrochemical gas detector, Carbon Monoxide (CO) 0-250ppm
5200262-02A Salwico GD EC H2, Electrochemical gas detector, Hydrogen (H2) 0-1000ppm

5200262-03A

Duct Mounting kit for Salwico GD 5200138, Square type


Square type of Duct mounting kit for the following gas detectors:
Salwico GD WH TRUE IR C3H8, True Infra-red gas detector, Propane 0-100% LEL
Salwico GD WH TRUE IR CH4, True Infra-red gas detector, Methane 0-100% LEL

5200138-00A
5200260-02A

52
Salwico Gas Detection System

Duct Mounting kit for Salwico GD 5200138, For JIS5K-200A


Circular type of Duct mounting kit for JIS5K-220A ducts, supports the following gas
detectors:
Salwico GD WH TRUE IR C3H8, True Infra-red gas detector, Propane 0-100% LEL
Salwico GD WH TRUE IR CH4, True Infra-red gas detector, Methane 0-100% LEL

5200138-00A
5200260-02A

Accessories for Gas Detectors


Standard Junction box for Salwico GD WH TRUE IR
(5200138-00A & 5200138-01A), Exd
Standard junction box for the Salwico GD True IR type of detectors (5200138-00A &
5200138-01A)

5200139-00A Salwico GD WH TRUE IR Junction box


5200202-00A Handheld Interrrogator TRUE IR
5200203-00A Duct Mounting Kit TRUE IR

DVC100 (i) Termination Junction box unit, Exd, with connection for Handheld
interrogator
Special junction box for very demanding application where easy maintenance is
essential.

5200259-00A

Alarm Devices
NS-ES, electronic siren, 24VDC, IP54, red.
The NS-ES is a Roshni LP sounder that can be connected to all Salwico safety systems.
It has a range of 32 tones which is set by a DIP switch. It is also equipped with a volume
control. The NS-ES is pre-set to tone no. 14 (970 Hz, 105 dBA (+/- 2 dBA) at 1 m). A
second tone is available, which can be switched in by the connection of a third core to
the siren. Volume control switch The switch will provide two settings, either full output
or an attenuation of 10dB.

N1535

53
Salwico Gas Detection System

NS-ES, electronic siren, 24VDC, IP66, red.


The NS-ES/IP66 is a low profile Banshee MT siren for all Salwico Safety systems for
installation in harsh enviroments (IP66). The siren is delivered with cable glands for
cable diameters raging from 8 to 13mm. The base has two knockout holes for the cable
glands. A sounder selector for user selectable tones and a volume control is fitted inside
the sounder.

N1525

Siren, Ex-proof, EExd, 24 VDC


DB3V is a lightweight, flameproof sounder intended for use in potentially explosive
atmospheres. DB3 has been designed with high ingress protection to withstand harsh
environmental conditions. The flame paths, flare and body are manufactured completely
from UV stable glass reinforced polyester. Stainless steel screws and sinter are incorpo-
rated thus ensuring a corrosion free product. DB3V has a pre-programmed bell-tone
and integral volume control. DB3V is delivered without cable glands. DB3 fulfils the fol-
lowing requirements: • Eexde IIC T5 • ATEX, Ex II 2GD • BASEEFA certified. DB3V
6255 is also available in GOST “R” & “K”, Chinese (CQST), Australian (SAA) and UL models.

Typhoons
The pneumatic alarm typhoons in the KTV and MKTV series are a maintenance free,
light, rigid and powerful signalling apparatus for different applications on-board
ships. The typhoons can be delivered as a complete unit or the horn and the solenoid
valve as separate units (see separate datasheet). For distinct signals, the piping
length between the valve and the horn should not exceed 6m. The horn is delivered
with wall bracket and filter. For explosive, corrosive or very hot areas the solenoid
valves shall be mounted separately outside the exposed area. The solenoid valve is
delivered with filter and fittings for copper piping with Ø 10 mm OD. The solenoid valve
should not be placed outdoor without protective cover.

6303 KTV-75/400 typhoon 24 VDC, 400Hz


6304 KTV-75/400 typhoon 230 VAC, 400Hz
6311 MKT-75/400 Typhoon without mag.valv. 400Hz

54
Salwico Gas Detection System

TV88 Magnet valve 220VAC


Soleniod valve for 6311 MKT-75/400 Typhoon without mag. Valv. 400Hz

6318

Non return valve


Soleniod valve for 6311 MKT-75/400 Typhoon without mag. Valv. 400Hz

6330

SUE-9412A-1, flash light, 230VAC, Eexd IIBT4


The SUE9412A-1 is a series of EX classified flash lights designed for use in very harsh
environments, for example pump rooms on vessels. SUE9412A-1 is available in the fol-
lowing models:
Art.no Power supply Colour on lens

6543 230VAC Blue


6545 230VAC Red
6547 230VAC Yellow
6548 115VAC Yellow
6549 Part no: 6549 230VAC Orange

Horn w. Red Rot. Light 230V Exd IIC T6


Electric horn with red rotating light for harsh environments, Exd IIC T6

5200117-00A

55
Salwico Gas Detection System
Portable Gas Detectors
Portable Gas Detectors
The Dräger X-am 2500 is one of a new generation of gas detectors which have
been specially designed for personal monitoring use. The 1- to 4-gas detector
reliably measures combustible gases and vapours, as well as O2, CO and H2S. Its
ergonomic design, mobile phone dimensions and low weight make it the perfect
companion in your daily work. Reliable measurement technology, long sensor life
and easy operation guarantee maximum safety at extremely low cost of ownership.

5100455-00A X-AM2500-HC,LEL
5100452-00A X-AM2500-HC,LEL-O2
5100453-00A X-AM2500-HC,LEL-H2S
5100453-00A X-AM2500-HC,LEL-O2-H2S
5100454-00A X-AM2500-HC,LEL-O2-CO-H2S

X-AM2000/5000-External pump module for Portable Gas Detectors


Pump module X-AM2000/5000 portable gas detectors.

4584

X-AM2000/5000 Chargeable batteries


Chargeable batteries for portable gas detectors of the type A-AM2000/5000 series

4586

56
Salwico Gas Detection System

X-AM5000-HC VOL%
X-am 7000 is the innovative solution for the simultaneous and continuous detection
of up to five gases. A combination of more than 25 sensors allows flexible solutions to
individual monitoring tasks. The Dräger X-am 7000 can be equipped with three elec-
trochemical, and two catalytic bead, infrared or photoionization sensors. It is the ideal
companion in a great number of applications where reliable monitoring of Oxygen,
toxic and combustibles gases and vapors in the ambient air is necessary.

4594

X-AM7000-HC Multigas Detector (HC, O2, H2S) w. Pump and IR sensor for
inert area
X-am 7000 is the innovative solution for the simultaneous and continuous detection
of up to five gases. A combination of more than 25 sensors allows flexible solutions to
individual monitoring tasks. The Dräger X-am 7000 can be equipped with three elec-
trochemical, and two catalytic bead, infrared or photoionisation sensors. It is the ideal
companion in a great number of applications where reliable monitoring of Oxygen,
toxic and combustibles gases and vapours in the ambient air is necessary.

5200049-00A

Viton hose
Viton hose (price per meter)

4220

Calibration Parts
CALIBRATION KIT, REG+FH
Calibration kit for all Salwico Gas Detectors. Parts included in the kit is:
1 x Regulator for the gas bottle
2m of tubing for connection between gas bottle and detector
1 x Flow house for ST-type detectors

5201013-00A

57
Salwico Gas Detection System
Calibration Gas Bottles
Sawico GDS Gas Bottles

Sawico GDS standard disposable calibration gas bottles. Should together with 5201013-
00A when calibrating any of the Salwico Gas Detectors.

The Salwico GDS gas bottles are available in the following variants.
5201000-10A Propane Calibration Gas Bottle, C3H8 50%LEL (0,85%) 112 Litre at 70 Bar
5201010-10A Propane/H2S Calibration Gas Bottle, C3H8 50%LEL (0,85%)+ H2S 20ppm+ Nitrogen
5201004-00A CO Calibration Gas Bottle, CO+oxygen 200 ppm
5201003-00A CO2 Calibration Gas Bottle, CO2+oxygen 5000 ppm
5201001-10A Methane Calibration Gas Bottle, CH4 50% LEL (2,2%) 112 Litre at 70 Bar
5201001-20A Methane Calibration Gas Bottle, CH4 100% Vol 112 Litre at 70 Bar
5201005-00A H2S Calibration Gas Bottle, H2S 20ppm 112 Litre at 70 Bar
5201006-00A N2 Calibration Gas Bottle, N2 100% Vol.

Moore calibration gas bottles with different mixtures are avalible on request

58
Salwico Gas Detection System
Salwico Gas Sampling System SW2020
SW2020
Salwico SW2020 is the safe choice.
Consilium Marine has over the years gained great experience of gas detection in marine
environments with thousands of systems installed in merchant and military vessels. The
SW2020-type is a well-proven scanning sampling gas alarm system intended for detec-
tion of gas in ballast tanks and void spaces. It has become the natural choice for discern-
ing ship owners, for retrofits as well as new buildings. The system combines extremely
reliable gas detection yet with a fast response to alarm conditions.
Salwico SW2020 offers versatility
With its flexible design the SW2020 system offers a high level of freedom of choice
with up to 4 different gas detectors of various types and a maximum of 64 sampling
points, furthermore possible to add a continuous measuring CO2-detector for moni-
toring of the CO2-room. Due to the systems design it offers a cost-effective way of
combining high-quality detectors and multiple sampling points in ballast tanks and void
spaces. It is also possible to divide sampling points into groups for simplified activation of
for instance stand-by mode for sampling points in ballast tanks when ballasting.

Salwico SW2020 provides safety


As part of the safety-thinking involved when designing the system it comes with internal
leakage and shut-off control as a standard feature. The system offers the possibility of
including a counter-pressure function to avoid clogging the pipes backed up by a purging
function. It can also incorporate a water trap as an option if so needed to minimize the
risk of condensation in the pipes. The hardware is developed with our well-proven fire
alarms as a basis why we can guarantee a high level of system security and as a result
an absolute minimum of maintenance requirements. The Salwico SW2020 system has
undergone environmental and working tests according to various norms and has been
approved by major classification societies and authorities worldwide. Due to the state-
of-the-art technology it also offers the possibility of integration to Salwico SMS Manage-
ment system, printers, VDR and other modern safety equipment.

Conclusion:
• Reliable • Flexible
• 1 to 4 detectors • 1 to 64 sampling points
• Pump redundancy, equipped with two pumps • Fast total sampling time

Suitable locations:
• Water ballast tanks • Non accessible areas
• Isolation spaces on LNG vessels

59
Salwico Monitoring System

Salwico
Monitoring
System

60
Salwico Monitoring System
Salwico Emission Monitoring System
M1040/SeaNox Analyser 220 VAC
The Salwico NOx analyser is a well-proven chemiluminescent Compact NOx Ana-
lyser with an integrated dilution that fully complies to “Marpol Annex IV NOx Techni-
cal Code”. The Salwico NOx analyser is specially designed for operation in continuous
emissions monitoring application with clean gas system and process control of DeNOx
system. The analyser is a complete, fully integrated monitoring system, configured and
tested according to the requirements for each application.
Easy menu drive operation, easy service and maintenance as well as a variety of built-in
550011 self checks and alarm features assures for a secure and reliable analyser.

M1040/SeaNox Analyser 115 VAC


The Salwico NOx analyser is a well-proven chemiluminescent Compact NOx Ana-
lyser with an integrated dilution that fully complies to “Marpol Annex IV NOx Techni-
cal Code”. The Salwico NOx analyser is specially designed for operation in continuous
emissions monitoring application with clean gas system and process control of DeNOx
system. The analyser is a complete, fully integrated monitoring system, configured and
tested according to the requirements for each application.
Easy menu drive operation, easy service and maintenance as well as a variety of built-in
self checks and alarm features assures for a secure and reliable analyser.
550015

M1050/SeaSox SO2 Analyser 220 VAC


The Salwico SO2 Analyser is a well-proven UV fluorescent Compact SO2 Analyser with
a integrated dilution that fully complies to “Marpol Annex IV NOx Technical Code”.
The Salwico SO2 Analyser is specially designed for operation in continuous emissions
monitoring application and for process control of scrubbers or equivalent systems. The
analyser is a complete, fully integrated monitoring system, configured and tested accord-
ing to the requirements for each application.
Easy menu drive operation, easy service and maintenance as well as a variety of built-in
self checks and alarm features assures for a secure and reliable analyser.
550040

M1050/SeaSox SO2 Analyser 115 VAC


The Salwico SO2 Analyser is a well-proven UV fluorescent Compact SO2 Analyser with
a integrated dilution that fully complies to “Marpol Annex IV NOx Technical Code”.
The Salwico SO2 Analyser is specially designed for operation in continuous emissions
monitoring application and for process control of scrubbers or equivalent systems. The
analyser is a complete, fully integrated monitoring system, configured and tested accord-
ing to the requirements for each application.
Easy menu drive operation, easy service and maintenance as well as a variety of built-in
550045 self checks and alarm features assures for a secure and reliable analyser.

61
Salwico Monitoring System

Guardian CO2 Analyser


The Salwico CO2 analyser provide continuous monitoring and control of gas con-
centration levels. It feature comprehensive output, alarm and fault indications via the
on-board microcontroller. Based on dual wavelength non-dispersive infra-red (NDIR)
technology, high performance operation with low maintenance requirements. The
operation of the CO2 analyser is described in terms of the outputs (display, LED indica-
tors, analogue output, alarm and fault relays), inputs (gas sensor, flow sensor, fault detec-
tion system) and the controls (setpoint controls, setpoint buttons, test button and the
550370 options bitswitch).

OM10 Zirconia O2 sensor


The Oxygen Probe Model OM10 is based on an in-situ-monitoring of the oxygen con-
centration in the flow gas without sampling. The OM10 probe is a simple and compact
low price probe well suited for non demanding use with exhaust gas temperatures up
to 600 °C. As well as under the condition that the flow gas is neither wet, nor contains
too much tar, dust or airborne particles. The OM10 probe zirconium oxide sensor gives
a precision of 0.1 % with 2 % oxygen concentration in the exhaust gas. The maintenance
need is low due to the fact that the OM10 has no moving parts and that the zirconium
oxide cell has a long lifetime and is easy to replace.
550030

Stack unit (required if distance to probe is longer then 10m)


Electrical connections are established with the help of an AMP-connector. If a V/I trans-
mitter is desired, the AMP-connector is kept in a watertight and chock
absorbing container. (For OM10 Zirconia sensor, 550030)

550160

DL256 STD Logger 1 x DM016 & 2 x IM001


The Salwico DL256 data logger system is designed for modern data acquisition
applications. The system can handle both analogue and digital input and output signals
as well as serial communication with monitors and sensors. The hardware is based on
modules and is therefore easy to upgrade by adding modules.

550060

62
Salwico Monitoring System

IM001 for ambient humidity, ambient pressure, engine interface


(rpm / kW and load) 4-20mA
The IM 001 isolated analogue input module accepts analogue voltage or current input.
The module can also drive passive sensors with no additional power supplies. The op-
eration mode of the module can be Voltage, Current or Current Active mode.
Voltage mode - In this operation mode the unit measure the voltage passively. Current
mode - This operation mode measure current with an external power supply.
Current Active mode - In this operation mode the measuring point do not have it’s
own power supply so therefore the active mode will supply the measuring point with
550080 the necessary power.

TM001 for ambient temperature


Isolated input module for a Pt100 type temperature sensor.

550070

Consilium probe switching unit (Measuring point 1-10)


For systems with more than 1 monitoring point we provide a Multiswitching unit (MSU)
The MSU consists of a PLC and temperature regulators and solenoids for sampling and
purging. The MSU will monitor on each point for 10 minutes.

Sample umbilical line per m


Umbilical Sampling Line (USL) consists of 1 power cable, 1 signal cable and 5 PTFE
tubings for sample, purge, dilution and 2 spares. The USL is prepared for connection at
probe side from Consilium for easy connection.

550140

63
Salwico Monitoring System

DP79100 dilution probe (one for each measuring point)


The Salwico DP7900 is a dilution probe to be used together with Salwico NOx and
SO2 compact gas analyser system. The DP7900 is with its uniformly heated dilution
block - particularly well suited for use in connection with wet scrubbers and other
applications where the stack gas is wet or has a temperature below acid and/or water
dewpoint. Accuracy of measurement is superior compared to other systems due to the
fact that no component of the sample will disappear as a result of condensation. The
550170 dilution probe is easy mounted for easy dismantling for filter checks and replacement
The Salwico DP7900 can be used in high temperature enviroments up to 1800°C.

Mounting flange for DP7900 probes (DIN100/ANSI 4” 150Ib)


Mounting Flange for DP7900 DN50 PN10 Stainless Steel flange with a 25mm Swagelok
connector to fit the guide tube.

550380

Probeflange gasket
Probeflange gasket for 550380 DN50 PN10

550382

HX110 Humidity and Temp sensor (ambient)


The HX110 is a sensor for recording the ambient air humidity and the ambient air
temperature. The range is 0-100% humidity and -20 to +80°C temperature. Gives a
4-20mA signal.

550110

64
Salwico Monitoring System

BM100 Pressure sensor (ambient)


The BM 100 sensor is used for recording the ambient air pressure. The range is 0.7 - 1.1
bar and it gives a 4-20mA signal.

550120

ComVisioner Full Version (required for g/Kw-h)


Presentation SW for the Salwico EMS. Ability to do custom made reports. Necessarry
to use to be able to calculate g/kWh.

550090

Spare part kit for SeaNox


Packing for vacuum pump Filter Media for fan, SK3170 Discharge plate for Ozone gen-
erator O-ring for Ozone generator Zero Air Scrubber.

550200

Spare part kit for SeaSox


Membrane set for Dual Chamber pump Filter media for Fan , SK3170 Zero Air Scrub-
ber.

550220

65
Salwico Monitoring System

Pump dual chamber


A dual chamber pump for Salwico EMS.

550260

Spare part kit for DP7900 probe


Spare part kit for DP7900 probe

550180

Spare part kit for Salwico (SeaNox/SeaSox) 1 year


Membrane set for Dual Chamber pump Filter media for Fan , SK3170 Zero Air Scrub-
ber.

550230

Spare part kit for Guardian CO2


Filter membrane.

550652

66
Salwico Monitoring System

Filterset for dilution probe


Filter set for cartridge, a complete setup of filters, O-rings and brackets to replace filters
in DP7900.

550647-00A

Salwico G1000 Smoke Density Monitoring System


Salwico G1000 Smoke Density Monitor 230VAC
The G1000 is a particular robust system well suited to resist heat and vibrations in and
around smoke stacks. The patented
technology do not locate the light source inside the smoke stack, instead, the infrared
LED is placed in the monitor cabinet and the light beam brought to the smoke stack
via robust optic fibres. The lenses of the optic heads are kept clean with purge air. Quite
evidently, this method reduces maintenance and need of spare parts to a bare mini-
mum. This invention was the first to make use of this design, sincerely appreciated by
6731003-00A our customers.

Salwico G1000 Smoke Density Monitor 110VAC


The G1000 is a particular robust system well suited to resist heat and vibrations in and
around smoke stacks. The patented technology do not locate the light source inside
the smoke stack, instead, the infrared LED is placed in the monitor cabinet and the light
beam brought to the smoke stack via robust optic fibres. The lenses of the optic heads
are kept clean with purge air. Quite evidently, this method reduces maintenance and
need of spare parts to a bare minimum. This invention was the first to make use of this
design, sincerely appreciated by our customers.
6731004-00A

Salwico G1000 Smoke Density Monitor 24VDC


The G1000 is a particular robust system well suited to resist heat and vibrations in and
around smoke stacks. The patented technology do not locate the light source inside
the smoke stack, instead, the infrared LED is placed in the monitor cabinet and the light
beam brought to the smoke stack via robust optic fibres. The lenses of the optic heads
are kept clean with purge air. Quite evidently, this method reduces maintenance and
need of spare parts to a bare minimum. This invention was the first to make use of this
design, sincerely appreciated by our customers.
6731005-00A

67
Salwico Monitoring System

Optical Fibers 6.0m


Fiber optic cable L=6.0 m – T<240°C

6731011-00A

Optical Fibers 7.5m


Fiber optic cable L=7.5 m – T<240°C

6731014-00A

Air Supply Filter Reg. w coupling


Air filter and regulator for instrument air.

6731021-00A

Flow meter Purge Air flow


Flow meter Purge Air flow for regulation of purge air protection of lens.

6731022-00A

68
Salwico Monitoring System

Remote Digital Display 5714D SDM 4-20mA


Remote digital display.

6731023-00A

Audit Pen 30%


Audit Pen 30% Opacity for calibration.

6700059-00A

Welding & Adjust. Bracket


Welding & Adjustment Bracket (set of two brackets with screws).

6731019-00A

Salwico G2000 Ambient Oil Mist Detection System


Salwico G2000 Ambient Oil Mist Detector 230VAC
The G2000 Ambient Oil Mist Detector is developed for monitoring pump rooms,
engine- and motor rooms and attached onto boilers or diesel engines. The perils of
oil mist and the potential impacts thereof, is clearly stated by IMO and OCIMF’s “Ship
Inspection Report (SIRE) Programme”. Thus, early alarms on the formation of oil mist
are utterly important. A minor investment yields great benefits, not the least appreci-
ated by vetting inspectors. The G2000 is ideal for applications where an instantaneous
and accurate response to oil mist, but also smoke or steam, is required in unattended
machinery spaces. The G2000 is a Line-Of-Sight opacity meter; aka; “Beam-” or “Open
6732003-00A Path-“ Detector” The Line-Of-Sight principle has the decisive advantage of covering a
larger area than single-point extractive- sampling systems.

69
Salwico Monitoring System

Salwico G2000 Ambient Oil Mist Detector 110VAC


The G2000 Ambient Oil Mist Detector is developed for monitoring pump rooms,
engine- and motor rooms and attached onto boilers or diesel engines. The perils of
oil mist and the potential impacts thereof, is clearly stated by IMO and OCIMF’s “Ship
Inspection Report (SIRE) Programme”. Thus, early alarms on the formation of oil mist
are utterly important. A minor investment yields great benefits, not the least appreci-
ated by vetting inspectors. The G2000 is ideal for applications where an instantaneous
and accurate response to oil mist, but also smoke or steam, is required in unattended
6732004-00A machinery spaces. The G2000 is a Line-Of-Sight opacity meter; aka; “Beam-” or “Open
Path-“ Detector” The Line-Of-Sight principle has the decisive advantage of covering a
larger area than single-point extractive- sampling systems.

Salwico G2000 Ambient Oil Mist Detector 24VDC


The G2000 Ambient Oil Mist Detector is developed for monitoring pump rooms,
engine- and motor rooms and attached onto boilers or diesel engines. The perils of
oil mist and the potential impacts thereof, is clearly stated by IMO and OCIMF’s “Ship
Inspection Report (SIRE) Programme”. Thus, early alarms on the formation of oil mist
are utterly important. A minor investment yields great benefits, not the least appreci-
ated by vetting inspectors. The G2000 is ideal for applications where an instantaneous
and accurate response to oil mist, but also smoke or steam, is required in unattended
machinery spaces. The G2000 is a Line-Of-Sight opacity meter; aka; “Beam-” or “Open
6732005-00A Path-“ Detector” The Line-Of-Sight principle has the decisive advantage of covering a
larger area than single-point extractive- sampling systems.

Manual G2000 AOMD


Manual G2000 AOMD.

6701140-00A

Optical Fibers 2x6.0m


Fiber optic cable L=6.0 m – T<240°C.

6732011-00A

70
Salwico Monitoring System

Optical Fibers 1x4.5m & 1x6.0m


Fiber optic cable L=4.5 m – T<240°C Fiber optic cable L=6.0 m - T<240°C.

6732013-00A

Optical Fibers 2x7.5m


Fiber optic cable L=7.5 m – T<240°C.

6732014-00A

Remote Digital Display 5714D AOMD 4-20mA


Remote digital display.

6732023-00A

Alarm Annunciator G2000 24VDC 8 Channels


The Alarm Monitor M4200 provides the possibility of monitoring 8 individual
processes. All inputs will accept any combination of NO or NC contacts. It is possible to
program each input, e.g. to activate the siren relay, the two alarm relays or
the four open collector outputs. The delays for the inputs can be selected between
25 milliseconds and 60 seconds. When alarm input is activated, the LED goes flashing,
alarm relay 1 and the siren relay goes ON. When reset button is activated, the LED
goes steady and the siren goes OFF together with alarm 1. When alarm input is de-
activated, LED goes OFF.
6732022-00A

71
You find us worldwide

Stockholm
Gothenburg

Oslo
Rotterdam
Zeebrugge
Newcastle Helsinki
Glasgow
Rochester Hamburg
Pusan
Dammam
Dalian
Houston
Long Beach Barcelona Piraeus Doha Mumbai Qingdao Tokyo
Bilbao
New York Vishakhapatnam Shanghai
Ft Lauderdale Hong Kong
Naples
Florence Hanoi
Genua
Cochin Ho Chi Minh
Abu Dhabi
Dubai

Oman
Singapore

Consilium Offices
Sales & Service Representatives

www.consilium.se

B001.1507.9

You might also like