34 ST 03 83 PDF
34 ST 03 83 PDF
Technical Information
Introduction
The SmartLine family of gauge pressure, differential Integral Three Button Configuration Option
pressure, and absolute pressure transmitters is designed
Suitable for all electrical and environmental requirements,
around a high performance piezo-resistive sensor. This one
SmartLine offer the ability to configure the transmitter and
sensor actually integrates multiple sensors linking process
display via three externally accessible buttons when either
pressure measurement with on-board static pressure (DP
display option is selected. Zero/span capabilities are also
Models) and temperature compensation measurements
optionally available via these buttons with or without selection
resulting in the best total performance available. This level of
of a display option.
performance allows the ST 800 to replace virtually any
competitive transmitter available today. Hand Held Configuration
Performance Specifications
Reference Accuracy: (conformance to +/-3 Sigma)
Reference
1,2
Maximum Accuracy
Turndown Stability (% Span)
Model URL LRL Min Span Ratio (% URL/Year) Std / Opt.
STG830 50 psi (3.5 bar) -14.7 psi (-1.0 bar) 0.5 psi (.035 bar)
STG83L 50 psi (3.5 bar) -14.7 psi (-1.0 bar) 0.5 psi (.035 bar)
STG840 500 psi (35 bar) -14.7 psi (-1.0 bar) 5 psi (.35 bar)
0.055 /
STG84L 500 psi (35 bar) -14.7 psi (-1.0 bar) 5 psi (.35 bar)
0.025%
STG870 3000 psi (210 bar) -14.7 psi (-1.0 bar) 30 psi (2.1 bar) 100:1 0.010
STG87L 3000 psi (210 bar) -14.7 psi (-1.0 bar) 30 psi (2.1 bar)
STG88L 6000 psi (420 bar) -14.7 psi (-1.0 bar) 60 psi (4.2 bar)
0.055 /
STG89L 10000 psi (690 bar) -14.7 psi (-1.0 bar) 100 psi (6.9 bar) 0.04%
Zero and span may be set anywhere within the listed (URL/LRL) range limits
For C
Turndowns A B D E
psi (bar)
Model URL Greater Then
STG830 50 psi (3.5 bar) 50:1 1 (0.07) 0.003
0.030
Standard Accuracy
Over pressure STG830: 75 psi (5.25 bar) STG83L: 75 psi (5.25 bar)
These are the pressure limits
the transmitters can STG840: 1500 psi (103 bar) STG84L: 1500 psi (103 bar)
withstand without damage STG870: 4500 psi (310 bar) STG87L: 4500 psi (310 bar)
STG88L: 9000 psi (620 bar)
STG89L: 15000 psi (1035 bar)
1
LCD Display operating temperature -20C to +70C . Storage temperature -30C to 80C.
2
Silicone 704 minimum temperature rating is 0oC (32oF). NEOBEE M-20 minimum temperature rating is -15oC (5oF)
NEOBEE is a registered trademark of Stepan Company
3
. Short term equals 2 hours at 70C (158F)
4.
Units can withstand overpressure of 1.5 x MAWP without damage
5
Consult factory for MAWP of ST 800 transmitters with CRN approval
6 STG800 Smart Pressure Transmitter
Materials Specifications (see model selection guide for availability/restrictions with various models)
Parameter Description
Barrier Diaphragms Material STG800: 316L SS, Hastelloy® C-2762, Monel® 400 3, Tantalum, Gold-plated 316L SS, Gold-plated
Hastelloy® C-276, Gold-plated Monel® 400
STG80L: 316L SS, Hastelloy C-276
Process Head Material STG800: Carbon Steel (Zinc Plated), 316 SS4, Hastelloy® C-2766, Monel® 400 7
STG80L: 316L SS, Hastelloy C-2766
Vent/Drain Valves & Plugs 1 STG800:316 SS4, Hastelloy C-2762, Monel 400 7
STG80L: N/A
Head Gaskets STG800: Glass-filled PTFE standard. Viton® and graphite are optional. STG80L: N/A
STG800: Carbon Steel (Zinc plated) standard. Options include 316 SS, NACE A286 SS bolts and
Meter Body Bolting
nuts or NACE A286 SS bolts and 304 SS nuts STG80L: N/A
Carbon Steel (Zinc-plated) or 304 Stainless Steel or 316SS angle bracket or Carbon Steel or
Mounting Bracket
304SS or 316SS flat bracket available .with 2” pipe bracket. See Figure 3
Fill Fluid Silicone 200, CTFE, NEOBEE M-20 or Silicone 704
Pure Polyester Powder Coated Low Copper (<0.4%)-Aluminum. Meets NEMA 4X, IP66, IP67 and
Electronic Housing
NEMA 7 (explosion proof). All stainless steel housing is optional.
Process Connections STG800: ½ -inch NPT(female), DIN 19213 (standard)
STG80L: ½ -inch NPT(female), ½ -inch NPT male, 9/16 Aminco, DIN19213 (except STG89L),
G ½ -B Male threaded
Wiring Accepts up to 16 AWG (1.5 mm diameter).
Dimensions See Figure 4.
Net Weight STG800: 8.3 pounds (3.8 Kg). STG80L: 3.6 pounds (1.6 Kg) with Aluminum Housing
1 2
Vent/Drains are sealed with Teflon® Hastelloy® C-276 or UNS N10276
3 4
Monel® 400 or UNS N04400 Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.
5
Carbon Steel heads are zinc-plated and not recommended for water service due to hydrogen migration. For that service, use 316 stainless steel wetted
Process Heads.
6
Hastelloy® C-276 or UNS N10276. Supplied as indicated or as Grade CW12MW, the casting equivalent of Hastelloy® C-276
7
Monel® 400 or UNS N04400. Supplied as indicated or as Grade M30C, the casting equivalent of Monel® 400
8 STG800 Smart Pressure Transmitter
HART Protocol
Compliance Testing:
Version: o Tested according to ITK 6.0.1
HART 7 Software Download
Power Supply Utilizes Class-3 of the Common Software Download
Voltage: 10.8 to 42.4Vdc at terminals procedure as per FF-883 which allows the field devices of any
Load: Maximum 1440 ohms See figure 2 manufacturer to receive software upgrades from any host.
Minimum Load: 0 ohms. (For handheld communications a Honeywell Digitally Enhanced (DE)
minimum load of 250 ohms is required) DE is a Honeywell proprietary protocol which provides
Foundation Fieldbus (FF) digital communications between Honeywell DE enabled
Power Supply Requirements field devices and Hosts.
Voltage: 9.0 to 32.0Vdc at terminals Power Supply
Steady State Current: 17.6mAdc Voltage: 10.8 to 42.4Vdc at terminals
Software Download Current: 27.4mAdc Load: Maximum 1440 ohms See figure 2
Available Function Blocks
Standard Diagnostics
Block Type Quantity Execution Time ST 800 top level diagnostics are reported as either critical
Resource 1 n/a or non-critical and readable via the DD/DTM tools or
integral display as shown
Transducer 1 n/a
Diagnostic 1 n/a
Analog Input 1* 30 ms
PID w/Autotune 1 45 ms
Integrator 1 30 ms
Flow Block 1 30 ms
Input Selector 1 30 ms
Arithmetic 1 30 ms
* AI block may have two (2) additional instantiations.
All available function blocks adhere to FOUNDATION
Fieldbus standards. PID blocks support ideal & robust PID
algorithms with full implementation of Auto-tuning.
Link Active Scheduler
Transmitters can perform as a backup Link Active
Scheduler and take over when the host is disconnected.
Acting as a LAS, the device ensures scheduled data
transfers typically used for the regular, cyclic transfer of
control loop data between devices on the Fieldbus.
Number of Devices/Segment
Entity IS model: 6 devices/segment
Explosionproof:
Class I, Division 1, Groups A, B, C, D;
Dust Ignition Proof:
Class II, III, Division 1, Groups E, F, G;
T5: -50 ºC to 85ºC
T6..T5 All Note 1
T6: -50 ºC to 65ºC
Class l, Zone 0/1, AEx db IIC T6..T5
Ga/Gb
Class ll, Zone 21, AEx tb IIIC T95o Db
Intrinsically Safe: 4-20 mA / DE/
Class I, II, III, Division 1, Groups A, B, C, Note 2a -50 ºC to 70ºC
HART
FM ApprovalsTM D, E, F, G: T4
USA
Class l, Zone 0, AEx ia IIC T4 Ga
Foundation
Note 2b -50 ºC to 70ºC
Fieldbus
FISCO Field Device (Only for FF Option)
Ex ia IIC T4 Ga; Ex ic IIC T4 Gc
Nonincendive:
Class I, Division 2, Groups A, B, C, D 4-20 mA / DE/
locations, T4 HART/ Foundation Note 1 -50 ºC to 85ºC
Fieldbus
Class l, Zone 2, AEx nA IIC T4 Gc
Enclosure: Type 4X/ IP66/ IP67 All All -
Explosion Proof:
Class I, Division 1, Groups A, B, C, D;
Dust Ignition Proof:
Class II, III, Division 1, Groups E, F, G;
T6..T5
T5: -50 ºC to 85ºC
All Note 1
T6: -50 ºC to 65ºC
Class I Zone 1 AEx db IIC T6..T5 Ga/Gb
Ex db IIC T6..T5 Ga/Gb
ATEX FISCO Field Device (Only for FF Option) Foundation -50 ºC to 70ºC
Note 2b
Fieldbus
Ex ia IIC T4 Ga; Ex ic IIC T4 Gc
4-20 mA / DE/
Nonincendive: HART/
Foundation Note 1 -50 ºC to 85ºC
II 3 G Ex nA IIC T4 Gc
Fieldbus
Enclosure: IP66/ IP67 All All -
Flameproof :
T5: -50 ºC to 85ºC
Ex db IIC T6..T5 Ga/Gb All Note 1
T6: -50 ºC to 65ºC
Ex tb IIIC Db T 95oC Db
Intrinsically Safe: 4-20 mA / DE/
Note 2a -50 ºC to 70ºC
Ex ia IIC T4 Ga HART
IECEx
World FISCO Field Device (Only for FF Option) Foundation
Note 2b -50 ºC to 70ºC
Fieldbus
Ex ia IIC T4 Ga; Ex ic IIC T4 Gc
Nonincendive: 4-20 mA / DE/
HART/
Ex nA IIC T4 Gc Foundation Note 1 -50 ºC to 85ºC
Fieldbus
Enclosure: IP66/ IP67 All All -
Flameproof :
Ex d IIC Ga/Gb T4 All Note 1 -50 ºC to 85ºC
Ex tb IIIC Db T 95oC
Intrinsically Safe: 4-20 mA / DE/
Note 2a -50 ºC to 70ºC
Ex ia IIC Ga T4 HART
SAEx
South Africa FISCO Field Device (Only for FF Option) Foundation
Note 2b -50 ºC to 70ºC
Fieldbus
Ex ia IIC T4 Ga; Ex ic IIC T4 Gc
Nonincendive: 4-20 mA / DE/
HART/
Ex nA IIC Gc T4 Foundation Note 1 -50 ºC to 85ºC
Fieldbus
Notes:
1. Operating Parameters:
Voltage= 11 to 42 V DC Current= 4-20 mA Normal
= 10 to 30 V (FF) = 30 mA (FF)
2. Intrinsically Safe Entity Parameters
a. Analog/ DE/ HART Entity Values:
Vmax= Ui = 30V Imax= Ii= 105mA Ci = 4.2nF Li =984 uH Pi =0.9W
Transmitter with Terminal Block Revision E or Later
Vmax= Ui = 30V Imax= Ii= 225mA Ci = 4.2nF Li = 0 Pi =0.9W
Note : Transmitter with Terminal Block Revision E or later
The revision is on the label that is on the module. There will be two lines of text on the label:
First is the Module Part #: 50049839-001 or 50049839-002
Second line has the supplier information, along with the REVISION:
XXXXXXX-EXXXX, THE “X” is production related, THE POSITION of the “E” IS THE REVISION.
This certificate defines the certifications covered for the ST 800 Pressure Transmitter family of
products, including the SMV 800 Smart Multivariable Transmitter. It represents the compilation
of the five certificates Honeywell currently has covering the certification of these products into
marine applications.
For ST 800 Smart Pressure Transmitter and SMV800 Smart Multivarible Transmitter
American Bureau of Shipping (ABS) - 2009 Steel Vessel Rules 1-1-4/3.7, 4-6-2/5.15, 4-8-3/13
& 13.5, 4-8-4/27.5.1, 4-9-7/13. Certificate number: 04-HS417416-PDA
Marine Certificates
Bureau Veritas (BV) - Product Code: 389:1H. Certificate number: 12660/B0 BV
Det Norske Veritas (DNV) - Location Classes: Temperature D, Humidity B, Vibration A, EMC B,
Enclosure C. For salt spray exposure; enclosure of 316 SST or 2-part epoxy protection with 316
SST bolts to be applied. Certificate number: A-11476
SIL 2/3 Certification IEC 61508 SIL 2 for non-redundant use and SIL 3 for redundant use according to EXIDA and
TÜV Nord Sys Tec GmbH & Co. KG under the following standards: IEC61508-1: 2010; IEC
61508-2: 2010; IEC61508-3: 2010.
millimeters
Reference Dimensions: inches
Figure 5 – Typical mounting dimensions of STG84L, STG87L, STG88L, & STG89L for reference
Model Selection Guides are subject to change and are inserted into the specifications as guidance only.
Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at:
www.honeywellprocess.com/en-US/pages/default.aspx
Model STG800
Gauge Pressure Transmitters
Model Selection Guide
34-ST-16-83 Issue 18
Instructions: Make selections from all Tables using column below the proper arrow. Asterisk indicates availability. Letter (a)
refers to restrictions highlighted in the restrictions table. Tables delimited w ith dashes.
KEY NUMBER URL/Max Span LRL Min Span Units Selection Availability
50 (3.5) -14.7 (-1.0) 0.5 (.035) psi (bar) STG830
Gauge
500 (35) -14.7 (-1.0) 5 (.35) psi (bar) STG840
Dual Head
3000 (210) -14.7 (-1.0) 30 (2.1) psi (bar) STG870
50 (3.5) -14.7 (-1.0) 0.5 (.035) psi (bar) STG83L
500 (35) -14.7 (-1.0) 5 (.35) psi (bar) STG84L
Gauge -14.7 (-1.0)
3000 (210) 30(2.1) psi (bar) STG87L
In-Line
6000 (420) -14.7 (-1.0) 60 (4.2) psi (bar) STG88L
10000 (690) -14.7 (-1.0) 100 (6.9) psi (bar) STG89L
TABLE VIII OTHER Certifications & Options: (String in sequence com m a delim ited (XX, XX, XX,….)
No additional options 00 * * * * * * *
Low Temperature Rating ( -50 deg C min. ambient operative temperature limit) LT w w w w w w w
NACE MR0175; MR0103; ISO15156 (FC33338) Process wetted parts only FG * * * * * * *
b
NACE MR0175; MR0103; ISO15156 (FC33339) Process wetted and non-wetted parts F7 c c c c c c c
Marine (DNV, ABS, BV, KR, LR) MT d d d d d d d
EN10204 Type 3.1 Material Traceability (FC33341) FX * * *
* * * *
MID Approved Transmitter - Contact Tech Support for specific MID approved ranges MD v v
Certificate of Conformance (F3391) F3 * * * * * * *
b
Calibration Test Report & Certificate of Conformance (F3399) F1 * * * * * * *
Certifications &
Certificate of Origin (F0195) F5 * * * * * * *
Warranty
FMEDA (SIL 2/3) Certification (FC33337) FE j j j j j j j
Over-Pressure Leak Test Certificate (1.5X MAWP) (F3392) TP * * * * * * *
Cert Clean for O2 or CL 2 service per ASTM G93 OX e e e e e e e
PMI Certification 1 PM * * * * * * *
Extended Warranty Additional 1 year 01 * * * * * * *
Extended Warranty Additional 2 years 02 * * * * * * *
Extended Warranty Additional 3 years 03 * * * * * * * b
Extended Warranty Additional 4 years 04 * * * * * * *
Extended Warranty Additional 15 years 15 * * * * * * *
1
The PM option is available on all Smartline Pressure Transmitter process wetted parts such as process heads, flanges, bushings and vent plugs except plated carbon
steel process heads and flanges. PM option information is also available on diaphragms except Gold plated and STG and STA in-line construction pressure
transmitters.
Singapore
Honeywell Pte Ltd.
Phone: +(65) 6580 3278
Fax: +(65) 6445-3033
South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799 6114
Fax: +(822) 792 9015
Process Solutions
Honeywell
1250 W Sam Houston Pkwy S
Houston, TX 77042