Data sheet 7KM3120-0BA01-1DA0

SENTRON PAC3120 LCD 96X96 mm Power Monitoring Device


Controll panel instrument for electrical values protocol: Modbus RTU
with graphics display U rated input: 690/400V 45-65Hz IE rated input:
X/1A oder X/5A AC Power supply: 100 ... 250 V +-10 % AC/DC
screw connections

Model
Product brand name SENTRON
Design of the product basic
Product type designation Measuring instrument
Type of measured value detection complete
Design of the power supply Wide-range power supply

General technical data


Cutout width 92 mm
Cutout height 92 mm
Size of Power Monitoring Device / company-specific size 96
Operating mode for measured value detection
● automatic line frequency detection Yes
● set at 50 Hz No
● set to 60 Hz No
Pulse duration
● initial value 30 ms
● Full-scale value 500 ms

7KM3120-0BA01-1DA0 Subject to change without notice


Page 1/7 01/22/2020 © Copyright Siemens
Voltage curve Sinusoidal or distorted
Measurable line frequency / initial value 45 Hz
Measurable line frequency / Full-scale value 65 Hz
Measuring procedure / for voltage measurement TRMS

Supply voltage
Type of voltage / of the supply voltage AC/DC
Measuring category / for supply voltage CATIII
Apparent power consumption
● without expansion module / typical 8 V·A

Protection class
Protection class IP
● on the front IP65
● Rear side IP20

Current
Measurable current
● 1 / at AC / Rated value 1 A
● 2 / at AC / Rated value 5 A

Suitability
Suitability for operation Installation in stationary control panels in closed rooms
Adjustable time period / minimum 10 ms

Product function
Product function
● Illuminance of display backlighting adjustable No
● Time-controlled reduction of the illuminance of Yes
display backlighting possible
● reactive power measurement Yes
● frequency measurement Yes
● pulse measurement Yes
● Display contrast adjustable Yes
● voltage measurement Yes
● Current measurement Yes
● active power measurement Yes

Display and operation


Design of the display LCD
Number of keys 4
Color / of the background of the display white
Product function / Display can be inverted (positive Yes
<=> negative mode)
Horizontal image resolution 128
Vertical screen resolution 96

7KM3120-0BA01-1DA0 Subject to change without notice


Page 2/7 01/22/2020 © Copyright Siemens
Communication
Number of active connections / at the Ethernet 3
interface
Protocol
● is supported Modbus RTU
Transfer rate
● minimum 4.8 kbit/s
● maximum 115.2 kbit/s

Fault limits
Reference condition / for metering accuracy In accordance with IEC61557-12, IEC62053-22 and IEC62053-23
Formula for relative total measurement inaccuracy
● for measured variable reactive energy Class 2 according to IEC61557-12 and/or IEC62053-23
● for measured variable output +/- 0,5 %
● for measured variable output factor +/- 0,5 %
● for measured variable voltage +/- 0,2 %
● for measured variable current +/- 0,2 %
● for measured variable active energy Cl. 0.5 acc. to... IEC62053-22

Inputs Outputs
Input voltage / at digital input
● at DC / maximum 30 V
Number of digital outputs 2
Number of digital inputs 2
Digital output version switching or pulse output function
Type of switching output bidirectional
Type of electrical connection
● at the digital inputs screw-type terminals
● at the digital outputs screw-type terminals
Input current / at digital input
● initial value for signal<1>-recognition 7 mA
Output current
● at the digital outputs / at DC / limited to 100 ms 130 mA
/ maximum
Operating conditions for digital inputs / external Yes
voltage supply
Operating voltage / as output voltage / at DC / 30 V
maximum permissible
Property of the output / Short-circuit proof Yes
Internal resistance / at the digital outputs 55 Ω
Switching frequency / at digital output / maximum 17 Hz

Measuring inputs
Outer conductors and neutral conductors internal 1.5 MΩ
resistance / for voltage measurement

7KM3120-0BA01-1DA0 Subject to change without notice


Page 3/7 01/22/2020 © Copyright Siemens
Measurable supply voltage
● between (PE)N and L / at AC / minimum 11.5 V
● between (PE)N and L / at AC / maximum 480 V
● between (PE)N and L / at AC / maximum rated 400 V
value
● between the outer conductors / at AC / 690 V
maximum rated value
Voltage measuring range extension / with external Yes
voltage transformers
Current measuring range extension / with external Yes
current transformers
Measuring category / for voltage measurement CATIII
Supply voltage / between the outer conductors / at 831 V
AC / maximum permissible
Continuous current / at AC / maximum permissible 10 A
Measuring category / for current measurement CATIII
Zero-point suppression / for current measurement 0 ... 10 %
Relative measurable current / at AC
● minimum 1 %
● maximum 100 %
Apparent power consumption / for current
measurement
● with measuring range 5 A / per phase 0.3 V·A
Measuring procedure / for current measurement TRMS

Connections
Type of electrical connection
● at the inputs for supply voltage screw-type terminals
● at the measurement inputs for voltage screw-type terminals
● at the measurement inputs for current screw-type terminals

Mechanical Design
Height 96 mm
Height / of the display 54 mm
Width 96 mm
Width
● of the display 72 mm
Depth 56 mm
Installation depth 51 mm
Mounting type / panel mounting Yes
Mounting position vertical
Material thickness / of the control panel
● maximum 4 mm
Net weight 325 g

7KM3120-0BA01-1DA0 Subject to change without notice


Page 4/7 01/22/2020 © Copyright Siemens
Environmental conditions
Installation altitude / at height above sea level / 2 000 m
maximum
Standard
● for pulse emitter according to IEC62053-31
Ambient temperature / during operation
● minimum -25 °C
● maximum 55 °C
Ambient temperature / during storage
● minimum -25 °C
● maximum 70 °C

Certificates
Certificate of suitability
● Approval Australia Yes

Declaration of Conformity other


Manufacturer Declaration

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=7KM3120-0BA01-1DA0
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/7KM3120-0BA01-1DA0
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=7KM3120-0BA01-1DA0
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications

7KM3120-0BA01-1DA0 Subject to change without notice


Page 5/7 01/22/2020 © Copyright Siemens
96 57,9
96

7KM3120-0BA01-1DA0 Subject to change without notice


Page 6/7 01/22/2020 © Copyright Siemens
7KM3120-0BA01-1DA0 Subject to change without notice
Page 7/7 01/22/2020 © Copyright Siemens

You might also like