Cooling Only Type
FTKS25EVMA / RKS25EBVMA
Cooling 2.5 (1.2-3.0) kW
8,500 (4,100-10,200) Btu/h
FTKS35EVMA / RKS35EBVMA
Cooling 3.5 (1.2-3.8) kW
11,900 (4,100-12,950) Btu/h
FTKS25/35E and FTXS25/35E Heat Pump Type
FTXS25EVMA / RXS25EBVMA
Cooling 2.5 (1.2-3.0) kW
8,500 (4,100-10,200) Btu/h
Heating 3.4 (1.2-4.5) kW
11,600 (4,100-15,350) Btu/h
FTXS35EVMA / RXS35EBVMA
Cooling 3.5 (1.2-3.8) kW
11,900 (4,100-12,950) Btu/h
RKS25/35EB and RXS25/35EB
Heating 4.0 (1.2-5.0) kW
13,600 (4,100-17,050) Btu/h
5
Cooling Only Type
FTKS50FVM / RKS50FVM
Cooling 5.0 (1.7-6.0) kW
17,100 (5,800-20,500) Btu/h
FTKS60FVM / RKS60FVM
Cooling 6.0 (1.7-6.7) kW
20,500 (5,800-22,900) Btu/h
FTKS71FVM / RKS71FVM
Cooling 7.1 (2.3-8.3) kW
24,200 (7,800-28,300) Btu/h
FTKS50/60/71F and FTXS50/60/71F Heat Pump Type
FTXS50FVMA / RXS50FVMA
Cooling 5.0 (1.7-6.0) kW
17,100 (5,800-20,500) Btu/h
Heating 5.8 (1.7-7.7) kW
19,800 (5,800-26,300) Btu/h
FTXS60FVMA / RXS60FVMA
Cooling 6.0 (1.7-6.7) kW
20,500 (5,800-22,900) Btu/h
Heating 7.0 (1.7-8.0) kW
23,900 (5,800-27,300) Btu/h
FTXS71FVMA / RXS71FVMA
RKS50/60/71F and RXS50/60F RXS71F Cooling 7.1 (2.3-8.5) kW
24,200 (7,800-29,000) Btu/h
Heating 8.2 (2.3-10.0) kW
28,000 (7,900-34,100) Btu/h
6
The DC Inverter series features the Reluctance 48%
COP
5.00 33%
DC motor for compressor and DC motor for fan. higher higher
NEW
NEW
the result of upgrading from conventional AC
Conventional
Conventional
2.00
inverter to advanced DC Inverter technology.
1.00
FTXE25BVMA
FTXS25EVMA Cooling operation Heating operation
Inverters are devices that are able to vary their operating capacity by adjusting frequency. Inverter air
conditioners can vary their heating/cooling capacity by adjusting the power supply frequency of their
compressors. In contrast, non-inverter air conditioners have a fixed cooling/heating capacity and can
only control the indoor temperature by starting or stopping their compressors.
Comfortable
Inverter air conditioners finely adjust Set Compressor off
temp.
capacity according to changes in the
air-conditioning load and the difference
Small temp.
between the indoor temperature and Cools a room difference
in less time Time
set temperature is small. These give
Too cool During cooling operation
higher comfort levels than with non-
Non-inverter type
inverter air conditioners. Inverter type
7
Energy-Saving Technological Features
Swing Compressor
Thanks to its smooth rotation, the Swing bush
Refrigerant gas
swing compressor decreases
friction and vibration. It also
prevents the leakage of
refrigerant gas during
compression. These advantages
Integral piston of
provide quiet and efficient blade and roller
Swing compressor
operation. The swing compressor can
reduce operational vibration and
Reluctance DC motor sound because its piston moves
smoothly inside the compressor.
What Is DC Inverter?
Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency
than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor
that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance
DC motor.
8
Intelligent Eye
When you are in the room, the air If Intelligent Eye detects no human When you enter the room,
conditioner maintains the set movement for 20 minutes, it Intelligent Eye automatically
temperature. automatically adjusts the set returns the temperature to the
temperature by 2 C. set level.
Econo Mode
This function limits both the maximum running current Running current and
power consumption
and maximum power consumption to 70% of those 100% Maximum during
during normal operation. It is particularly effective if the Normal normal operation
operation
cooling/heating load is high, for example, at start-up or
during large gatherings and periods of direct sunshine.
At the same time, it maintains maximum capacity at 70% Maximum during
Econo Mode
80% of normal, giving improved operating efficiency,
although it may take slightly longer to reach the set Econo
temperature. Mode
9
Indoor Unit Quiet Operation
FTK(X)S25E
Fan speeds Sound levels
Outdoor Unit Quiet Operation is available for all models 22 dB (A) Is So Quiet You Can Even Hear Whispers
from 2.5 to 7.1 kW class. This function decreases the
operation sound level by 3 or 4 dB (A) below the rated
Indoor unit Outdoor unit
operation. It provides a low sound level of 43 dB (A) for
RK(X)S25EB.
Capacity may decrease when Outdoor Unit Quiet Operation is selected.
20 22 30 40 43 50 (dB (A))
RK(X)S25EB
Operations Sound levels
Rustling of leaves Library
10
Titanium Apatite Photocatalytic
Air-Purifying Filter
Titanium apatite is a new
photocatalytic material with advanced
adsorption power. While the filter’s micron-
level fibres trap dust, this photocatalyst Air filter
Catches dust
effectively adsorbs and decomposes bacteria.
The photocatalyst is activated simply by exposure to
light. The filter delivers consistent performance for
approximately 3 years if periodic maintenance is
performed.
Titanium Apatite
Photocatalytic
Air-Purifying Filter
Bacteria removal test This filter is not a medical device. Benefits such as the
Testing method: Dropping method adsorption and decomposition of bacteria are only effective
Testing organisation: Japan Spinners Inspecting Foundation for substances that are collected on and in direct contact with
Result certificate: No. 012553-1 and 012553-2 the Titanium Apatite Photocatalytic Air-Purifying Filter.
Odours
A chemical reaction
decomposes the odours
into CO2, O3 and H2.
11
Mould-Proof Operation
When cooling or dry operation is stopped, fan-only
operation runs automatically for 1 hour. This airflow
dries the inside of the indoor unit to reduce the
generation of mould and odours. It is available with
FTK(X)S25/35E.
12
Inverter Powerful Operation Vertical Auto-Swing (up and down)
Inverter Powerful Operation boosts cooling/heating
performance for a 20-minute period. This is convenient Horizontal Auto-Swing (left and right)
both when you first turn on your air conditioner and
when you want to quickly change the temperature
during operation. 3-D Airflow
Vertical Auto-Swing automatically moves the flaps up
and down and Horizontal Auto-Swing automatically
moves the louvers to the left and right. 3-D Airflow
combines Vertical and Horizontal Auto-Swing to circulate
air to every part of a room for uniform cooling/heating
of even large spaces.
Horizontal Auto-Swing and 3-D Airflow are available for FTK(X)S50/60/71F.
Wide-Angle Louvers
Power-Airflow Dual Flaps and Wide-Angle Louvers work
in tandem to precisely control both vertical and
horizontal airflow for distribution of air.
Power-Airflow Dual Flaps
Time 60 minutes
Off timer turns on Off timer stops air conditioner
Cooling operation: Room temperature is raised by 0.5 C after 60 minutes.
Covers even Heating operation: Room temperature is lowered by 2 C after 60 minutes.
a spacious room
13
Home Leave Operation Anticorrosion Treatment of Outdoor
Heat Exchanger Fins
Home Leave Operation prevents large rises or falls in The outdoor unit’s heat exchanger fins are processed
the indoor temperature by continuing operation* while using a special anticorrosion treatment. The surface is
you are sleeping or out of your home. This means that covered with a thin acrylic resin layer to enhance the
an air-conditioned welcome awaits when you wake or fins’ resistance to acid rain and salt corrosion. A
return. It also means that the indoor temperature can hydrophilic film layer also prevents rust caused by the
quickly return to your favourite comfort setting. run off of water droplets.
* Home Leave Operation can be set at any temperature from 18 to 32 C for
cooling operation and 10 to 30 C for heating operation.
Home Leave Operation is available for FTK(X)S50/60/71F. Cross section of anticorrosion-treated fin
Hydrophilic film
During cooling operation, 23 C for Aluminium
the room temperature setting, and Corrosion-resistant
28 C for the Home Leave setting. acrylic resin
23 C
10 10
0 0
23 C 10 10
20 20
Installation Flexibility
Push again!! A long piping length gives installation flexibility.
When you return, you will
Installation is possible even if there is no space for the
be greeted by an air- outdoor unit near the indoor unit.
conditioned room. Just
push the HOME LEAVE Max. piping length Max. height difference
button again to return to
your previous settings. FTK(X)S25/35E 20 m 15 m
FTK(X)S50/60/71F 30 m 20 m
14
Function Dictionary
Timers
Econo Mode
This mode limits maximum running current and power
consumption to 70% of normal operation, while maintaining 24-Hour On/Off Timer
maximum capacity at 80%. This improves operating This timer can be preset to start and stop at any time
efficiency and also prevents circuit breakers from being within a 24-hour period. The air conditioner is started/
overloaded. stopped simply by pressing the On/Off timer button on
See page 9 the wireless remote controller.
15
Function List
Indoor unit
Cleanliness Models Wall-mounted type
FTK(X)S FTK(X)S
Titanium Apatite Photocatalytic Functions 25/35E 50/60/71F
Air-Purifying Filter DC Inverter
This filter contains the new photocatalytic material
titanium apatite. While the filter’s micron-level fibres trap Power-Airflow
dust, this photocatalyst adsorbs and decomposes Dual Flaps
Comfortable Airflow
bacteria. The filter can be used for up to 3 years with
proper maintenance. Wide-Angle Louvers
See page 11
Vertical Auto-Swing
(up and down)
Mould-Proof Operation
Mould-Proof Operation automatically runs fan-only Horizontal Auto-Swing
operation for 1 hour when cooling or dry operation is (left and right)
stopped. This airflow prevents the generation of mould
and mould odours inside the indoor unit. 3-D Airflow
See page 12
Indoor Unit Quiet
Wipe-Clean Flat Panel Operation
The flat panel models can be cleaned with only the single
Intelligent Eye
Comfort Control
pass of a cloth across their smooth surface. The flat
panel can also be easily removed for more thorough
cleaning. Automatic Operation*
See page 12
Programme Dry
Function
Others
Auto Fan Speed
Comfort Control
Lifestyle Convenience
Econo Mode
Quick Warming Function
During low outdoor temperatures, this function pre-heats the Inverter Powerful
compressor to shorten the time required to discharge warm air. Operation
Home Leave
Automatic Defrosting Operation
Before starting heating operation, a sensor checks for frost in Indoor Unit On/Off
the outdoor unit and performs automatic defrosting if necessary Switch
so that only warm air is discharged. Titanium Apatite
Photocatalytic
Air-Purifying Filter
Cleanliness
Hot-Start Function
After defrosting or when starting heating operation, air is pre- Mould-Proof
heated before discharge to prevent uncomfortable cold drafts. Operation
Auto-Restart after
Worry Free
Power Failure
Self-Diagnosis with
Digital Display
* Available with the heat pump type.
Outdoor unit
Models
RKS25/35EB RKS50/60/71F
RXS25/35EB RXS50/60/71F
Functions
Comfort
Control
Outdoor Unit
Quiet Operation
Anticorrosion Treat-
Worry
Exchanger Fins
16
Easy-to-Use Wireless Remote Controller
Vertical Auto-Swing
(up and down)
Econo Mode
Selects fan speed and
Indoor Unit Quiet Operation On/Off Switch
Sets room temperature
Selects mode: automatic, cooling, *
heating, dry, fan-only operation Inverter Powerful Operation
Sets clock
Vertical Auto-Swing
(up and down) Home Leave Operation
Sets timer
Sets clock
17
Specifications
FTK(X)S25/35E FTK
Cooling only Heat pump
Model name Indoor unit FTKS25EVMA FTKS35EVMA FTXS25EVMA FTXS35EVMA Mod
Outdoor unit RKS25EBVMA RKS35EBVMA RXS25EBVMA RXS35EBVMA
Rated kW 2.5 (1.2-3.0) 3.5 (1.2-3.8) 2.5 (1.2-3.0) 3.5 (1.2-3.8)
Cooling
(Min.-Max.) Btu/h 8,500 (4,100-10,200) 11,900 (4,100-12,950) 8,500 (4,100-10,200) 11,900 (4,100-12,950)
Capacity Capa
Rated kW 3.4 (1.2-4.5) 4.0 (1.2-5.0)
Heating
(Min.-Max.) Btu/h 11,600 (4,100-15,350) 13,600 (4,100-17,050)
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz Pow
Cooling 3.5 4.9 3.5 4.9
Running current Rated A Runn
Heating 4.3 5.1
Cooling Rated 600 (300-800) 1,020 (300-1,200) 600 (300-800) 1,020 (300-1,200)
Power consumption W Pow
Heating (Min.-Max.) 830 (290-1,340) 1,080 (290-1,550)
Cooling 4.17 3.43 4.17 3.43 COP
COP Rated W/W
Heating 4.10 3.70
Indoor unit FTKS25EVMA FTKS35EVMA FTXS25EVMA FTXS35EVMA Indo
Front panel colour White Fron
Cooling m3/min 8.7 (307) 8.9 (314) 8.7 (307) 8.9 (314) Airflo
Airflow rate (H)
Heating (cfm) 9.4 (332) 9.7 (342)
Fan speed 5 steps, quiet and automatic Fan
Sound levels Cooling 37/25/22 38/26/23 37/25/22 38/26/23 Soun
(H/L/SL) dB (A) (H/L
Heating 37/28/25 38/29/26
Dimensions (H x W x D) mm 283 x 800 x 195 Dime
Machine weight kg 9 Mac
Outdoor unit RKS25EBVMA RKS35EBVMA RXS25EBVMA RXS35EBVMA Outd
Casing colour Ivory white Casi
Type Hermetically sealed swing type Com
Compressor
Motor output W 600
Refrigerant charge (R-410A) kg 1.0 Refr
Cooling 46/43 47/44 46/43 47/44 Soun
Sound levels (H/L) dB (A)
Heating 47/44 48/45
Dimensions (H x W x D) mm 550 x 765 x 285 Dime
Machine weight kg 34 Mac
Cooling CDB 10 to 46 10 to 46 Ope
Operation range
Heating CWB 10 to 20
Liquid 6.4
Piping connections Gas mm 9.5 Pipin
Drain 18.0
Max. piping length 20 Max
m Max
Max. height difference 15
Note: The above values are based on operation with a 220 V, 50 Hz power supply. Note: T
18
Specifications
FTK(X)S50/60/71F
Cooling only Heat pump
Model name Indoor unit FTKS50FVM FTKS60FVM FTKS71FVM FTXS50FVMA FTXS60FVMA FTXS71FVMA
Outdoor unit RKS50FVM RKS60FVM RKS71FVM RXS50FVMA RXS60FVMA RXS71FVMA
Rated kW 5.0 (1.7-6.0) 6.0 (1.7-6.7) 7.1 (2.3-8.3) 5.0 (1.7-6.0) 6.0 (1.7-6.7) 7.1 (2.3-8.5)
Cooling
(Min.-Max.) Btu/h 17,100 (5,800-20,500) 20,500 (5,800-22,900) 24,200 (7,800-28,300) 17,100 (5,800-20,500) 20,500 (5,800-22,900) 24,200 (7,800-29,000)
Capacity
Rated kW 5.8 (1.7-7.7) 7.0 (1.7-8.0) 8.2 (2.3-10.0)
Heating
(Min.-Max.) Btu/h 19,800 (5,800-26,300) 23,900 (5,800-27,300) 28,000 (7,900-34,100)
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz
Cooling 7.2 9.2 11.5 7.2 9.2 10.8
Running current Rated A
Heating 7.4 9.4 11.6
Cooling Rated 1,550 (440-2,080) 1,990 (440-2,400) 2,510 (570-3,580) 1,550 (440-2,080) 1,980 (440-2,390) 2,360 (570-3,200)
Power consumption W
Heating (Min.-Max.) 1,600 (400-2,530) 2,040 (400-2,810) 2,520 (520-3,730)
Cooling 3.23 3.02 2.83 3.23 3.03 3.01
COP Rated W/W
Heating 3.63 3.43 3.25
Indoor unit FTKS50FVM FTKS60FVM FTKS71FVM FTXS50FVMA FTXS60FVMA FTXS71FVMA
Front panel colour White
Cooling m3/min 14.7 (519) 16.2 (572) 17.4 (614) 14.7 (519) 16.2 (572) 17.4 (614)
Airflow rate (H)
Heating (cfm) 16.2 (572) 17.4 (614) 21.5 (759)
Fan speed 5 steps, quiet and automatic
Sound levels Cooling 43/34/31 45/36/33 46/37/34 44/35/32 45/36/33 46/37/34
(H/L/SL) dB (A)
Heating 42/33/30 44/35/32 46/37/34
Dimensions (H x W x D) mm 290 x 1,050 x 238
Machine weight kg 12
Outdoor unit RKS50FVM RKS60FVM RKS71FVM RXS50FVMA RXS60FVMA RXS71FVMA
Casing colour Ivory white
Type Hermetically sealed swing type
Compressor
Motor output W 1,100 1,920 1,100 1,920
Refrigerant charge (R-410A) kg 1.50 1.70 1.50 2.30
Cooling 47/44 49/46 53/49 47/44 49/46 52/49
Sound levels (H/L) dB (A)
Heating 48/45 49/46 52/49
Dimensions (H x W x D) mm 735 x 825 x 300 770 x 900 x 320
Machine weight kg 47 55 48 71
Cooling CDB 10 to 46
Operation range
Heating CWB 15 to 18
Liquid 6.4
Piping connections Gas mm 12.7 15.9 12.7 15.9
Drain 18.0
Max. piping length m 30
Max. height difference m 20
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound levels are based on the temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during
actual operation as a result of ambient conditions.
19
Options
Indoor unit
No. Item FTK(X)S25/35E FTK(X)S50/60/71F
1 5-room centralised controller *1 KRC72
5-room centralised Titanium apatite photocatalytic Titanium apatite photocatalytic Remote controller loss
controller air-purifying filter air-purifying filter prevention with chain
KRC72 KAF970A46 KAF952B42 KKF917A4
Outdoor unit
No. Item RK(X)S25/35EB RKS50/60/71F, RXS50/60F RXS71F
1 Air direction adjustment grille KPW937A4 KPW945A4
2 Drain plug KKP937A4*1 KKP945A4
Note: *1. One set includes 5 pieces for 5 units.
Control system
No. Item FTK(X)S25/35E FTK(X)S50/60/71F
1 Central remote controller *1 DCS302CA61
2 Unified On/Off controller *1 DCS301BA61
3 Schedule timer *1 DST301BA61
4 Interface adaptor for DIII-NET use KRP928BB2S
Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
20
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User’s Manual carefully before using this product. The User’s Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Organization: Organization:
DAIKIN INDUSTRIES, LTD. DAIKIN INDUSTRIES
AIR CONDITIONING MANUFACTURING DIVISION (THAILAND) LTD. All of the Daikin Group’s business
Scope of Registration: facilities and subsidiaries in Japan
Scope of Registration: are certified under the ISO 14001
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF THE DESIGN/DEVELOPMENT
COMMERCIAL AIR CONDITIONING, HEATING, COOLING, international standard for
AND MANUFACTURE OF AIR environment management.
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, CONDITIONERS AND THE
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT COMPONENTS INCLUDING
RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS USED FOR THEM
JMI-0107 COMPRESSORS AND VALVES. JQA-1452
Dealer
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
c All rights reserved
07/12 P.C.
ange. Specifications, designs and other content appearing in this brochure are current as of July 2012 but subject to change without notice.