Daikin Split AC Catalog

This document provides specifications for various Daikin air conditioner models. It lists the cooling and heating capacities in kW and BTU/h for both cooling only and heat pump models in their 25/35, 50/60/71, and 100 size classes. It also describes the benefits of DC inverter technology, such as more efficient variable capacity operation, energy savings, and improved temperature control compared to non-inverter models.

Uploaded by

ocean_220
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
558 views22 pages

Daikin Split AC Catalog

This document provides specifications for various Daikin air conditioner models. It lists the cooling and heating capacities in kW and BTU/h for both cooling only and heat pump models in their 25/35, 50/60/71, and 100 size classes. It also describes the benefits of DC inverter technology, such as more efficient variable capacity operation, energy savings, and improved temperature control compared to non-inverter models.

Uploaded by

ocean_220
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 22

PCR0709A

1
2
3
4
Cooling Only Type
FTKS25EVMA / RKS25EBVMA
Cooling 2.5 (1.2-3.0) kW
8,500 (4,100-10,200) Btu/h
FTKS35EVMA / RKS35EBVMA
Cooling 3.5 (1.2-3.8) kW
11,900 (4,100-12,950) Btu/h
FTKS25/35E and FTXS25/35E Heat Pump Type
FTXS25EVMA / RXS25EBVMA
Cooling 2.5 (1.2-3.0) kW
8,500 (4,100-10,200) Btu/h
Heating 3.4 (1.2-4.5) kW
11,600 (4,100-15,350) Btu/h
FTXS35EVMA / RXS35EBVMA
Cooling 3.5 (1.2-3.8) kW
11,900 (4,100-12,950) Btu/h
RKS25/35EB and RXS25/35EB
Heating 4.0 (1.2-5.0) kW
13,600 (4,100-17,050) Btu/h

* Available with the heat pump type.

5
Cooling Only Type
FTKS50FVM / RKS50FVM
Cooling 5.0 (1.7-6.0) kW
17,100 (5,800-20,500) Btu/h
FTKS60FVM / RKS60FVM
Cooling 6.0 (1.7-6.7) kW
20,500 (5,800-22,900) Btu/h
FTKS71FVM / RKS71FVM
Cooling 7.1 (2.3-8.3) kW
24,200 (7,800-28,300) Btu/h
FTKS50/60/71F and FTXS50/60/71F Heat Pump Type
FTXS50FVMA / RXS50FVMA
Cooling 5.0 (1.7-6.0) kW
17,100 (5,800-20,500) Btu/h
Heating 5.8 (1.7-7.7) kW
19,800 (5,800-26,300) Btu/h
FTXS60FVMA / RXS60FVMA
Cooling 6.0 (1.7-6.7) kW
20,500 (5,800-22,900) Btu/h
Heating 7.0 (1.7-8.0) kW
23,900 (5,800-27,300) Btu/h
FTXS71FVMA / RXS71FVMA
RKS50/60/71F and RXS50/60F RXS71F Cooling 7.1 (2.3-8.5) kW
24,200 (7,800-29,000) Btu/h
Heating 8.2 (2.3-10.0) kW
28,000 (7,900-34,100) Btu/h

* Available with the heat pump type.

6
The DC Inverter series features the Reluctance 48%
COP
5.00 33%
DC motor for compressor and DC motor for fan. higher higher

This hi-tech energy-saving package is completed 4.17 4.10


4.00
by Daikin’s advanced swing compressor and
PAM control. FTXS25E achieves a COP of 4.17, 3.09
3.00 2.82
48% higher than conventional model. This is

NEW

NEW
the result of upgrading from conventional AC

Conventional
Conventional
2.00
inverter to advanced DC Inverter technology.

1.00
FTXE25BVMA
FTXS25EVMA Cooling operation Heating operation

Inverter Advantages Compared to Non-Inverter

Inverters are devices that are able to vary their operating capacity by adjusting frequency. Inverter air
conditioners can vary their heating/cooling capacity by adjusting the power supply frequency of their
compressors. In contrast, non-inverter air conditioners have a fixed cooling/heating capacity and can
only control the indoor temperature by starting or stopping their compressors.

Powerful Variable Capacity Operation


Inverter air conditioners operate at Compressor
Inverter Power Control High
maximum capacity as soon as they Raise frequency High-speed rotation capacity
start up. As a result, the set Power
source Low
temperature can be reached more Lower frequency Low-speed rotation capacity
quickly.
Non-inverter type air conditioner Compressor
Energy Saving
Power Constant speed Fixed capacity
After the indoor temperature source rotation
approaches the set temperature,
Inverter air conditioners are able to vary their operating capacity. Non-inverter air conditioners can
Inverter Control adjusts to low only operate at a fixed capacity.

capacity operation to maintain this


temperature. This makes inverter
models more energy-saving than Comfortable Temperature Control
non-inverter models, which must
repeatedly start or stop their Temp.
compressors to maintain the room
temperature. Compressor off
Not cool

Comfortable
Inverter air conditioners finely adjust Set Compressor off
temp.
capacity according to changes in the
air-conditioning load and the difference
Small temp.
between the indoor temperature and Cools a room difference
in less time Time
set temperature is small. These give
Too cool During cooling operation
higher comfort levels than with non-
Non-inverter type
inverter air conditioners. Inverter type

Starts This diagram is a representation for illustrative purpose only.

7
Energy-Saving Technological Features

Swing Compressor
Thanks to its smooth rotation, the Swing bush
Refrigerant gas
swing compressor decreases
friction and vibration. It also
prevents the leakage of
refrigerant gas during
compression. These advantages
Integral piston of
provide quiet and efficient blade and roller
Swing compressor
operation. The swing compressor can
reduce operational vibration and
Reluctance DC motor sound because its piston moves
smoothly inside the compressor.

Reluctance DC Motor for Compressor


Daikin DC Inverter models are equipped with Efficiency of Reluctance DC motor *4
the Reluctance DC motor for compressor. The Reluctance DC motor
Reluctance DC motor uses 2 different types Motor efficiency (%)
90

of torque, neodymium magnet*1 and


reluctance torque*2. This motor can save 80
Conventional
energy because it generates more power More than 20%
DC motor
70
with a smaller electric power than an AC or
conventional DC motor. It is more efficient at AC motor
Neodymium magnets are used 60
in the pink-coloured area.
the low frequencies most commonly used by
air conditioners,*3 improving efficiency by
50
approximately 20%. 0 30 60 90 120
Rotational speed (rps)
Small load Large load
Low capacity High capacity
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite
magnet.
*2. The torque created by the change in power between the iron and magnet parts. *4. Data are based on studies conducted
*3. The frequency range used by air conditioners during periods of stable operation. under controlled conditions at a Daikin
This is the range in which air conditioners operate for the longest periods. laboratory.

DC Motor for Fan PAM Control


The DC motor allows fine rotation Efficiency of DC motor for fan *5
(comparison with a conventional AC motor)
control, which reduces energy 100
Efficiency (%)

consumption. The motor also 80


provides improvements in DC motor
Approx.
operational efficiency of up to 40%, 60 20%
increase
compared to an AC motor. These PAM (Pulse Amplitude Modulation)
40
improvements are particularly
Approx.
40%
AC motor control reduces energy loss by
noticeable in the low-speed range. 20 increase
controlling how often the converter
0 switches on and off.
200 300 400 500 600 700 800 900 1000
Motor speed (rpm)
*5. Data are based on studies conducted
under controlled conditions at a Daikin
laboratory.

What Is DC Inverter?
Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency
than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor
that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance
DC motor.

8
Intelligent Eye

Intelligent Eye prevents energy wastage by using its Top view


infrared sensor to detect human movement in a room.
When there is no movement, Intelligent Eye increases/
7m
decreases the temperature by 2 C to give energy
savings. This reduces energy wastage if, for example, 110˚
you forget to turn off the air conditioner.
All models from 2.5 to 7.1 kW class are equipped
with Intelligent Eye. This function can be conveniently The Intelligent Eye Intelligent Eye Side view
activated from the remote controller. indicator lights when sensor 7m
movement is detected.
Once Intelligent Eye is set, it continues to work to save energy. You do not
need to push the SENSOR button each time you wish to use this function.

When you are in the room, the air If Intelligent Eye detects no human When you enter the room,
conditioner maintains the set movement for 20 minutes, it Intelligent Eye automatically
temperature. automatically adjusts the set returns the temperature to the
temperature by 2 C. set level.

Econo Mode button

Intelligent Eye button

Econo Mode

This function limits both the maximum running current Running current and
power consumption
and maximum power consumption to 70% of those 100% Maximum during
during normal operation. It is particularly effective if the Normal normal operation
operation
cooling/heating load is high, for example, at start-up or
during large gatherings and periods of direct sunshine.
At the same time, it maintains maximum capacity at 70% Maximum during
Econo Mode
80% of normal, giving improved operating efficiency,
although it may take slightly longer to reach the set Econo
temperature. Mode

Econo Mode is also useful for preventing circuit


breakers from being overloaded during temporary Time
From start-up until set
peaks in the running current. The function is easily temperature is reached
activated from the remote controller by pushing the
ECONO button. Econo Mode is available for • This diagram is a representation for illustrative purposes only.
• Maximum capacity decreases during Econo Mode, requiring
FTK(X)S25/35E. more time to reach the set temperature.

9
Indoor Unit Quiet Operation

This series gives you the choice of 5-step, Quiet or


Automatic settings for the fan speed. The Quiet setting
selects Indoor Unit Quiet Operation. This function
decreases the operation sound level by 3 dB (A) below
the Low setting.
This wide range of settings allows you to precisely
control the fan speed according to your requirements.
For example, Indoor Unit Quiet Operation provides you
with a good night’s sleep. The sound level for FTK(X)S
25E is 22 dB (A).

FTK(X)S25E
Fan speeds Sound levels

High (H) 37 dB (A)


Auto SL L M H
Low (L) 25 dB (A)
3 dB (A)
Quiet (SL) 22 dB (A)
During cooling operation Fan
Low High
speed

Sound Each decrease in airflow volume


level reduces the sound level.

Indoor Unit Quiet Operation icon

Selects fan speed and


Indoor Unit Quiet Operation

Outdoor Unit Quiet Operation

Outdoor Unit Quiet Operation

Outdoor Unit Quiet Operation is available for all models 22 dB (A) Is So Quiet You Can Even Hear Whispers
from 2.5 to 7.1 kW class. This function decreases the
operation sound level by 3 or 4 dB (A) below the rated
Indoor unit Outdoor unit
operation. It provides a low sound level of 43 dB (A) for
RK(X)S25EB.
Capacity may decrease when Outdoor Unit Quiet Operation is selected.
20 22 30 40 43 50 (dB (A))
RK(X)S25EB
Operations Sound levels
Rustling of leaves Library

Rated (H) 46 dB (A) Pendulum of a wall clock Normal office


3 dB (A)
Quiet (L) 43 dB (A) Based on “Examples of Sound Levels”, Ministry of the Environment, Japan,
November 12, 2002
During cooling operation

10
Titanium Apatite Photocatalytic
Air-Purifying Filter
Titanium apatite is a new
photocatalytic material with advanced
adsorption power. While the filter’s micron-
level fibres trap dust, this photocatalyst Air filter
Catches dust
effectively adsorbs and decomposes bacteria.
The photocatalyst is activated simply by exposure to
light. The filter delivers consistent performance for
approximately 3 years if periodic maintenance is
performed.

Titanium Apatite
Photocatalytic
Air-Purifying Filter

Bacteria removal test This filter is not a medical device. Benefits such as the
Testing method: Dropping method adsorption and decomposition of bacteria are only effective
Testing organisation: Japan Spinners Inspecting Foundation for substances that are collected on and in direct contact with
Result certificate: No. 012553-1 and 012553-2 the Titanium Apatite Photocatalytic Air-Purifying Filter.

Effect of Titanium Apatite Photocatalyst


Apatite adsorbs bacteria.
Adsorbs Removes At the same time, the
photocatalyst oxidises
Light
odour components,
breaking them down.
Odours
Decomposed
Bacteria
Deactivated

Titanium Apatite Photocatalyst

Photocatalyst Mechanism Light Odours


Light strikes the
The Titanium Apatite Photocatalytic Air-Purifying Filter photocatalyst and
incorporates titanium apatite. Titanium apatite is a new Active activates the surface
photocatalyst material with advanced adsorption power. particles particles.
Photocatalyst
When this photocatalyst is exposed to light, a powerful
oxidising action occurs.

Odours
A chemical reaction
decomposes the odours
into CO2, O3 and H2.

The odourless substances


are released into the air.

11
Mould-Proof Operation
When cooling or dry operation is stopped, fan-only
operation runs automatically for 1 hour. This airflow
dries the inside of the indoor unit to reduce the
generation of mould and odours. It is available with
FTK(X)S25/35E.

Wipe-Clean Flat Panel


Flat panel models can be cleaned instantly Conventional Front Grille Design
with a single wipe of a cloth across their
smooth surface. If more thorough cleaning is
required, the panel can also be easily 1. Difficult to remove dust on the
grille through wiping alone
removed from the unit.

Dust 2. Reduced capacity due to


increased suction resistance

Front grille design units


collect dust on their air
3. High sound levels due to
inlet grilles unless these
increased suction resistance
grilles are cleaned
regularly.

12
Inverter Powerful Operation Vertical Auto-Swing (up and down)
Inverter Powerful Operation boosts cooling/heating
performance for a 20-minute period. This is convenient Horizontal Auto-Swing (left and right)
both when you first turn on your air conditioner and
when you want to quickly change the temperature
during operation. 3-D Airflow
Vertical Auto-Swing automatically moves the flaps up
and down and Horizontal Auto-Swing automatically
moves the louvers to the left and right. 3-D Airflow
combines Vertical and Horizontal Auto-Swing to circulate
air to every part of a room for uniform cooling/heating
of even large spaces.
Horizontal Auto-Swing and 3-D Airflow are available for FTK(X)S50/60/71F.

Power-Airflow Dual Flaps

Wide-Angle Louvers
Power-Airflow Dual Flaps and Wide-Angle Louvers work
in tandem to precisely control both vertical and
horizontal airflow for distribution of air.
Power-Airflow Dual Flaps

Indoor Unit On/Off Switch


The unit can be conveniently started
manually in the event the wireless
remote controller is misplaced or
the wireless remote controller
Cooling: the flaps flatten out during Heating: the flaps descend to blow batteries are not charged.
operation so that cool air slides off to warm air directly down to the floor to Indoor Unit On/Off Switch
reach the corner of the room. quickly warm the whole room.

Wide-Angle Louvers Night Set Mode

Pressing the Off timer button automatically selects Night


Set Mode. This function prevents excessive cooling or
heating for your pleasant sleep. Room temperature is
raised by 0.5 C after 60 minutes for cooling operation and
the temperature is lowered by 2 C after 60 minutes for
From a corner heating operation.
to the centre +0.5 C Cooling
The louvers can be
Set temp. before
adjusted by hand for Off timer begins
FTK(X)S25/35E and with to operate
the wireless remote
controller for
FTK(X)S50/60/71F. 2 C Heating

Time 60 minutes
Off timer turns on Off timer stops air conditioner
Cooling operation: Room temperature is raised by 0.5 C after 60 minutes.
Covers even Heating operation: Room temperature is lowered by 2 C after 60 minutes.
a spacious room

13
Home Leave Operation Anticorrosion Treatment of Outdoor
Heat Exchanger Fins
Home Leave Operation prevents large rises or falls in The outdoor unit’s heat exchanger fins are processed
the indoor temperature by continuing operation* while using a special anticorrosion treatment. The surface is
you are sleeping or out of your home. This means that covered with a thin acrylic resin layer to enhance the
an air-conditioned welcome awaits when you wake or fins’ resistance to acid rain and salt corrosion. A
return. It also means that the indoor temperature can hydrophilic film layer also prevents rust caused by the
quickly return to your favourite comfort setting. run off of water droplets.
* Home Leave Operation can be set at any temperature from 18 to 32 C for
cooling operation and 10 to 30 C for heating operation.
Home Leave Operation is available for FTK(X)S50/60/71F. Cross section of anticorrosion-treated fin

Hydrophilic film
During cooling operation, 23 C for Aluminium
the room temperature setting, and Corrosion-resistant
28 C for the Home Leave setting. acrylic resin

23 C

Heat exchanger fin

Wide Operation Range


One push!!
Start Home Leave With the heat pump type FTXS50/60/71F, cooling
Operation simply by operation is possible even during outdoor temperatures
pushing its button on the of as low as 10 C. Heating operation can also be
remote controller.
performed during outdoor temperatures of 15 to 18 C.
28 C This makes these units ideal for even very
cold areas.

When you are out of


your home, your air
Heat pump type FTXS50/60/71F
conditioner prevents
large rises/falls in the 50 50
indoor temperature by Cooling
continuing to operate 40 40
Outdoor temp. (˚CWB)
Outdoor temp. (˚CDB)

using Home Leave


30 30
Operation settings.
20 20
Heating

10 10

0 0
23 C 10 10

20 20

Installation Flexibility
Push again!! A long piping length gives installation flexibility.
When you return, you will
Installation is possible even if there is no space for the
be greeted by an air- outdoor unit near the indoor unit.
conditioned room. Just
push the HOME LEAVE Max. piping length Max. height difference
button again to return to
your previous settings. FTK(X)S25/35E 20 m 15 m
FTK(X)S50/60/71F 30 m 20 m

14
Function Dictionary

Comfortable Airflow Comfort Control

Power-Airflow Dual Flaps Indoor Unit Quiet Operation


Power-Airflow Dual Flaps can flatten out during cooling Indoor unit operating sound levels are decreased by 3 dB
operation to deliver cool air to the corners of a room. The (A) from the Low setting fan speed using the wireless
flaps can direct warm air straight down to the floor during remote controller.
heating operation. See page 10
See page 13
Outdoor Unit Quiet Operation
Wide-Angle Louvers Outdoor unit operating sound levels are decreased by 3 or 4
The smoothly curved Wide-Angle Louvers provide wide dB (A) from the rated operation sound using the wireless
airflow coverage for effective operation no matter where remote controller.
the indoor unit is placed in a room. See page 10
See page 13
Intelligent Eye
Vertical Auto-Swing (up and down) Intelligent Eye with its infrared sensor automatically
This function automatically moves the flaps up and down controls air conditioner operation according to human
to distribute air across a room. movement in a room. When there is no movement, it
See page 13 adjusts the temperature by 2 C for energy savings.
See page 9
Horizontal Auto-Swing (left and right)
Horizontal Auto-Swing automatically moves the louvers Automatic Operation
to the left and right to cover a room with cool/warm air. This function automatically selects cooling or heating
See page 13
operation mode based on the room temperature at
start-up.
3-D Airflow
This function combines Vertical and Horizontal Auto- Programme Dry Function
Swing to circulate a cloud of cool/warm air right to the This function automatically reduces the level of humidity.
corners of even large spaces.
See page 13
Auto Fan Speed
The microprocessor automatically controls fan speed to
Lifestyle Convenience adjust the room temperature to the set temperature.

Timers
Econo Mode
This mode limits maximum running current and power
consumption to 70% of normal operation, while maintaining 24-Hour On/Off Timer
maximum capacity at 80%. This improves operating This timer can be preset to start and stop at any time
efficiency and also prevents circuit breakers from being within a 24-hour period. The air conditioner is started/
overloaded. stopped simply by pressing the On/Off timer button on
See page 9 the wireless remote controller.

Inverter Powerful Operation Night Set Mode


This function is convenient for boosting cooling/heating
Pressing the Off timer button automatically selects Night
performance for a 20-minute period both when you first
Set Mode. This function prevents excessive cooling or
turn on your air conditioner or want to quickly change the
heating for your pleasant sleep. Room temperature is
room temperature.
raised by 0.5 C after 60 minutes for cooling operation
See page 13
and the temperature is lowered by 2 C after 60 minutes
for heating operation.
Home Leave Operation
See page 13
Home Leave Operation continues operation to prevent a
room from becoming too hot or cold, while you are
sleeping or out of your home. Select any temperature Worry Free
from 18 to 32 C for cooling operation and 10 to 30 C for
heating operation.
See page 14 Auto-Restart after Power Failure
The air conditioner memorises the settings for mode,
Indoor Unit On/Off Switch airflow, temperature, etc., and automatically returns to
The unit can be conveniently started manually in the them when power is restored after a power failure.
event the wireless remote controller is misplaced or the
wireless remote controller batteries are not charged. Self-Diagnosis with Digital Display
See page 13 Malfunction codes are shown on the digital display panel
of the wireless remote controller for fast and easy
maintenance.

Anticorrosion Treatment of Outdoor


Heat Exchanger Fins
The outdoor unit’s heat exchanger fins are processed
using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the fins’
resistance to acid rain and salt corrosion.
See page 14

15
Function List

Indoor unit
Cleanliness Models Wall-mounted type
FTK(X)S FTK(X)S
Titanium Apatite Photocatalytic Functions 25/35E 50/60/71F
Air-Purifying Filter DC Inverter
This filter contains the new photocatalytic material
titanium apatite. While the filter’s micron-level fibres trap Power-Airflow
dust, this photocatalyst adsorbs and decomposes Dual Flaps

Comfortable Airflow
bacteria. The filter can be used for up to 3 years with
proper maintenance. Wide-Angle Louvers
See page 11
Vertical Auto-Swing
(up and down)
Mould-Proof Operation
Mould-Proof Operation automatically runs fan-only Horizontal Auto-Swing
operation for 1 hour when cooling or dry operation is (left and right)
stopped. This airflow prevents the generation of mould
and mould odours inside the indoor unit. 3-D Airflow
See page 12
Indoor Unit Quiet
Wipe-Clean Flat Panel Operation
The flat panel models can be cleaned with only the single
Intelligent Eye
Comfort Control
pass of a cloth across their smooth surface. The flat
panel can also be easily removed for more thorough
cleaning. Automatic Operation*
See page 12
Programme Dry
Function
Others
Auto Fan Speed

Comfort Control
Lifestyle Convenience

Econo Mode
Quick Warming Function
During low outdoor temperatures, this function pre-heats the Inverter Powerful
compressor to shorten the time required to discharge warm air. Operation
Home Leave
Automatic Defrosting Operation
Before starting heating operation, a sensor checks for frost in Indoor Unit On/Off
the outdoor unit and performs automatic defrosting if necessary Switch
so that only warm air is discharged. Titanium Apatite
Photocatalytic
Air-Purifying Filter
Cleanliness

Hot-Start Function
After defrosting or when starting heating operation, air is pre- Mould-Proof
heated before discharge to prevent uncomfortable cold drafts. Operation

Wipe-Clean Flat Panel

24-Hour On/Off Timer


Timers

Night Set Mode

Auto-Restart after
Worry Free

Power Failure

Self-Diagnosis with
Digital Display
* Available with the heat pump type.

Outdoor unit
Models
RKS25/35EB RKS50/60/71F
RXS25/35EB RXS50/60/71F
Functions
Comfort
Control

Outdoor Unit
Quiet Operation

Anticorrosion Treat-
Worry

ment of Outdoor Heat


Free

Exchanger Fins

16
Easy-to-Use Wireless Remote Controller

Wireless remote controller for FTK(X)S25/35E

Vertical Auto-Swing
(up and down)
Econo Mode
Selects fan speed and
Indoor Unit Quiet Operation On/Off Switch
Sets room temperature
Selects mode: automatic, cooling, *
heating, dry, fan-only operation Inverter Powerful Operation

Outdoor Unit Quiet Operation


Mould-Proof Operation
Intelligent Eye

Cancels On/Off Timer


24-Hour On Timer

24-Hour Off Timer


and Night Set Mode
Sets timer

Sets clock

*Available with the heat pump type.

Wireless remote controller for FTK(X)S50/60/71F

Vertical Auto-Swing
(up and down) Home Leave Operation

Selects fan speed and On/Off Switch


Indoor Unit Quiet Operation
Sets room temperature
Selects mode: automatic, cooling, *
Inverter Powerful Operation
heating, dry, fan-only operation
Outdoor Unit Quiet Operation
Intelligent Eye
Horizontal Auto-Swing
(left and right)
Cancels On/Off Timer
24-Hour On Timer
24-Hour Off Timer
and Night Set Mode

Sets timer

Sets clock

*Available with the heat pump type.

17
Specifications
FTK(X)S25/35E FTK
Cooling only Heat pump
Model name Indoor unit FTKS25EVMA FTKS35EVMA FTXS25EVMA FTXS35EVMA Mod
Outdoor unit RKS25EBVMA RKS35EBVMA RXS25EBVMA RXS35EBVMA
Rated kW 2.5 (1.2-3.0) 3.5 (1.2-3.8) 2.5 (1.2-3.0) 3.5 (1.2-3.8)
Cooling
(Min.-Max.) Btu/h 8,500 (4,100-10,200) 11,900 (4,100-12,950) 8,500 (4,100-10,200) 11,900 (4,100-12,950)
Capacity Capa
Rated kW 3.4 (1.2-4.5) 4.0 (1.2-5.0)
Heating
(Min.-Max.) Btu/h 11,600 (4,100-15,350) 13,600 (4,100-17,050)
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz Pow
Cooling 3.5 4.9 3.5 4.9
Running current Rated A Runn
Heating 4.3 5.1
Cooling Rated 600 (300-800) 1,020 (300-1,200) 600 (300-800) 1,020 (300-1,200)
Power consumption W Pow
Heating (Min.-Max.) 830 (290-1,340) 1,080 (290-1,550)
Cooling 4.17 3.43 4.17 3.43 COP
COP Rated W/W
Heating 4.10 3.70
Indoor unit FTKS25EVMA FTKS35EVMA FTXS25EVMA FTXS35EVMA Indo
Front panel colour White Fron
Cooling m3/min 8.7 (307) 8.9 (314) 8.7 (307) 8.9 (314) Airflo
Airflow rate (H)
Heating (cfm) 9.4 (332) 9.7 (342)
Fan speed 5 steps, quiet and automatic Fan
Sound levels Cooling 37/25/22 38/26/23 37/25/22 38/26/23 Soun
(H/L/SL) dB (A) (H/L
Heating 37/28/25 38/29/26
Dimensions (H x W x D) mm 283 x 800 x 195 Dime
Machine weight kg 9 Mac
Outdoor unit RKS25EBVMA RKS35EBVMA RXS25EBVMA RXS35EBVMA Outd
Casing colour Ivory white Casi
Type Hermetically sealed swing type Com
Compressor
Motor output W 600
Refrigerant charge (R-410A) kg 1.0 Refr
Cooling 46/43 47/44 46/43 47/44 Soun
Sound levels (H/L) dB (A)
Heating 47/44 48/45
Dimensions (H x W x D) mm 550 x 765 x 285 Dime
Machine weight kg 34 Mac
Cooling CDB 10 to 46 10 to 46 Ope
Operation range
Heating CWB 10 to 20
Liquid 6.4
Piping connections Gas mm 9.5 Pipin
Drain 18.0
Max. piping length 20 Max
m Max
Max. height difference 15
Note: The above values are based on operation with a 220 V, 50 Hz power supply. Note: T

Measurement conditions Meas


1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 1. Co
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m. 2. He
3. Sound levels are based on the temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during 3. So
actual operation as a result of ambient conditions. ac

18
Specifications
FTK(X)S50/60/71F
Cooling only Heat pump
Model name Indoor unit FTKS50FVM FTKS60FVM FTKS71FVM FTXS50FVMA FTXS60FVMA FTXS71FVMA
Outdoor unit RKS50FVM RKS60FVM RKS71FVM RXS50FVMA RXS60FVMA RXS71FVMA
Rated kW 5.0 (1.7-6.0) 6.0 (1.7-6.7) 7.1 (2.3-8.3) 5.0 (1.7-6.0) 6.0 (1.7-6.7) 7.1 (2.3-8.5)
Cooling
(Min.-Max.) Btu/h 17,100 (5,800-20,500) 20,500 (5,800-22,900) 24,200 (7,800-28,300) 17,100 (5,800-20,500) 20,500 (5,800-22,900) 24,200 (7,800-29,000)
Capacity
Rated kW 5.8 (1.7-7.7) 7.0 (1.7-8.0) 8.2 (2.3-10.0)
Heating
(Min.-Max.) Btu/h 19,800 (5,800-26,300) 23,900 (5,800-27,300) 28,000 (7,900-34,100)
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz
Cooling 7.2 9.2 11.5 7.2 9.2 10.8
Running current Rated A
Heating 7.4 9.4 11.6
Cooling Rated 1,550 (440-2,080) 1,990 (440-2,400) 2,510 (570-3,580) 1,550 (440-2,080) 1,980 (440-2,390) 2,360 (570-3,200)
Power consumption W
Heating (Min.-Max.) 1,600 (400-2,530) 2,040 (400-2,810) 2,520 (520-3,730)
Cooling 3.23 3.02 2.83 3.23 3.03 3.01
COP Rated W/W
Heating 3.63 3.43 3.25
Indoor unit FTKS50FVM FTKS60FVM FTKS71FVM FTXS50FVMA FTXS60FVMA FTXS71FVMA
Front panel colour White
Cooling m3/min 14.7 (519) 16.2 (572) 17.4 (614) 14.7 (519) 16.2 (572) 17.4 (614)
Airflow rate (H)
Heating (cfm) 16.2 (572) 17.4 (614) 21.5 (759)
Fan speed 5 steps, quiet and automatic
Sound levels Cooling 43/34/31 45/36/33 46/37/34 44/35/32 45/36/33 46/37/34
(H/L/SL) dB (A)
Heating 42/33/30 44/35/32 46/37/34
Dimensions (H x W x D) mm 290 x 1,050 x 238
Machine weight kg 12
Outdoor unit RKS50FVM RKS60FVM RKS71FVM RXS50FVMA RXS60FVMA RXS71FVMA
Casing colour Ivory white
Type Hermetically sealed swing type
Compressor
Motor output W 1,100 1,920 1,100 1,920
Refrigerant charge (R-410A) kg 1.50 1.70 1.50 2.30
Cooling 47/44 49/46 53/49 47/44 49/46 52/49
Sound levels (H/L) dB (A)
Heating 48/45 49/46 52/49
Dimensions (H x W x D) mm 735 x 825 x 300 770 x 900 x 320
Machine weight kg 47 55 48 71
Cooling CDB 10 to 46
Operation range
Heating CWB 15 to 18
Liquid 6.4
Piping connections Gas mm 12.7 15.9 12.7 15.9
Drain 18.0
Max. piping length m 30
Max. height difference m 20
Note: The above values are based on operation with a 220 V, 50 Hz power supply.

Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound levels are based on the temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during
actual operation as a result of ambient conditions.

19
Options

Indoor unit
No. Item FTK(X)S25/35E FTK(X)S50/60/71F
1 5-room centralised controller *1 KRC72

2 Wiring adaptor for time clock/remote controller KRP413AB1S


(Normal open pulse contact/normal open contact) *2
3 Titanium apatite photocatalytic air-purifying filter *3 KAF970A46 KAF952B42
4 Remote controller loss prevention with chain KKF917A4
Note: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*2. The time clock and other devices should be obtained locally.
*3. The filter is a standard accessory. It should be replaced approximately every 3 years.

5-room centralised Titanium apatite photocatalytic Titanium apatite photocatalytic Remote controller loss
controller air-purifying filter air-purifying filter prevention with chain
KRC72 KAF970A46 KAF952B42 KKF917A4

Outdoor unit
No. Item RK(X)S25/35EB RKS50/60/71F, RXS50/60F RXS71F
1 Air direction adjustment grille KPW937A4 KPW945A4
2 Drain plug KKP937A4*1 KKP945A4
Note: *1. One set includes 5 pieces for 5 units.

Air direction adjustment grille Drain plug


KPW945A4 KKP937A4

Control system
No. Item FTK(X)S25/35E FTK(X)S50/60/71F
1 Central remote controller *1 DCS302CA61
2 Unified On/Off controller *1 DCS301BA61
3 Schedule timer *1 DST301BA61
4 Interface adaptor for DIII-NET use KRP928BB2S
Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.

Central remote controller Unified On/Off controller Schedule timer


DCS302CA61 DCS301BA61 DST301BA61

Specifications are subject to change.

20
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User’s Manual carefully before using this product. The User’s Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

Organization: Organization:
DAIKIN INDUSTRIES, LTD. DAIKIN INDUSTRIES
AIR CONDITIONING MANUFACTURING DIVISION (THAILAND) LTD. All of the Daikin Group’s business
Scope of Registration: facilities and subsidiaries in Japan
Scope of Registration: are certified under the ISO 14001
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF THE DESIGN/DEVELOPMENT
COMMERCIAL AIR CONDITIONING, HEATING, COOLING, international standard for
AND MANUFACTURE OF AIR environment management.
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, CONDITIONERS AND THE
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT COMPONENTS INCLUDING
RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS USED FOR THEM
JMI-0107 COMPRESSORS AND VALVES. JQA-1452

Dealer
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
c All rights reserved
07/12 P.C.

ange. Specifications, designs and other content appearing in this brochure are current as of July 2012 but subject to change without notice.