Manufacturers’s Document No. CIPL/GAIL/JHBDPL BAPL‐ SEC‐ II/TCP/PRO/M15/02 Date
Item Document Index
Project No. Serial No. Rev. No. 17.02.2020
No.
GAIL‐JHBDPL BAPL‐SEC II
T C
P P R
O M 1
5 R 2
Document title :
INSTALLATION PROCEDURE OF COATING INTEGRITY TEST
PAGE NO.
1 / 7
COMMENTS RESOLUTION SHEET
(Document No. CIPL/GAIL/JHBDPL BAPL‐ SEC‐ II/TCP/PRO/M15/02)
PROJECT TITLE : BOKARO‐ANGUL SECTION II OF JAGDISHPUR‐HALDIA‐BOKARO‐DHAMRA
PIPELINE PROJECT (JHBDPL) PH‐II
CLIENT : GAIL (INDIA) LIMITED
CONSULTANT : MECON LIMITED
CONTRACTOR : CORRTECH INTERNATIONAL PVT. LTD.
1 INTRODUCTION
The coating is premire external corrosion protection method for pipelines . As such the selection
and continued intergrity of pipeline coating is paramount importance.It is the coating that
determine the cathodic proection requirements and the magnitude of pipeline maintance
expenditures to prevent failures such as metal loss and stress corrosion cracking .The fundamental
contributions that the coating makes to stopping external corrosion are:
1. Isolating the anode and cathode areas of the corrosion cells from each other.
2. Isolating the common electrolyte –the moist soil – from both the anode and cathode areas.
2 PURPOSE
To describe the procedure for conducting coating integrity survey for evaluating electrical strength
of pipeline coating and provide adequate quality assurance / control of workmanship at site.
3 SCOPE
This procedure covers the methodology of conducting coating integrity survey Pipeline segment
(Like – HDD)
4 RESPOSIBILITY
It is the responsibility of the site engineer to ensure that the readings are correctly taken. The
responsibility shall also cover the proper supervision to take readings work as required.
5 MATERIAL AND EQUIPMENTS
Equipment : Calibrated portable multi meter, Standard Copper‐ Copper Sulphate
Reference Cell, Battery, Flexible cable, Sacrificial Anode, Earthing Rods / Pipe Pieces and Tool kit
with all accessories etc.
6 PROCEDURE FOR COATING INTEGRITY TESTING
The integrity of Pipeline coating shall be carried out after Pull back operation of HDD pipeline
section.
CIPL/GAIL/JHBDPL BAPL‐ SEC‐ DATE : 17.02.2020
TITLE : COATING INTEGRITY SURVEY
II/TCP/PRO/M15/02 PAGE : 2 / 7
GAIL ( INDIA ) LIMITED
The test must be carried out before the HDD pipeline section is tied in to main pipeline
section
Pipe to cable connection to be done both side of HDD section.
Measure the natural potential at both side of HDD section.
Setup the temporary impressed current system with digital multimeter connected to measure
output current to the GI/Copper strip at minimum distance from HDD Pipeline.
DC source ( 12 V DC battery) shall be used to impressed current into the HDD section.
Positive terminal of DC source connect to the Ground through GI/Copper strip and Negative
Terminal connected to pipeline through potentiometer.
Place the reference cell at the remote end (opposite to impressed current system) to monitor
the PSP of HDD section.
Impress current into the bored pipe start at zero amps and increase slowly until the bored
pipe potential is depressed to 1.5 V ON Potenetial with respect to the Cu‐Cuso4 electrode.
Note the Current from digital multimeter.
After that disconnect the termporary anode and measure OFF potential at entry side and
remote side.
Attached a 6A switch in the (‐) line circuit of the P/L to measure the off potential on both side
of HDD section.
7 CONNECTION SCHEME
CIPL/GAIL/JHBDPL BAPL‐ SEC‐ DATE : 17.02.2020
TITLE : COATING INTEGRITY SURVEY
II/TCP/PRO/M15/02 PAGE : 3 / 7
GAIL ( INDIA ) LIMITED
8 EQUATIONS
Average Potential, ∆Eavg = (∆E1 + ∆E2) / 2
Where ,
∆E1 = E1ON – E1OFF
∆E2 = E2ON – E2OFF
Coating Resistance ,RC = ∆Eavg / Ic
Where ,
RC ‐ Coating resistance , Ohm
∆Eavg ‐ Average Potnential , mV
Ic – Applied Current , mA
Surface Area,S.A = π D L
Where ,
S.A – Surface area , m2
π – Constant (3.1416)
D – Diameter of pipeline , m
L – Length of HDD Section , m
Specific coating resistance ,rc’=Rc x S.A
Where ,
rc’ ‐ Specific Coating resistance , Ohm‐m2
Rc ‐ Coating resistance , Ohm
S.A ‐ Surface area , m2
9 PRECAUTIONS
DC source (12 V battery) shall be fully charged before carrying the test.
Ensure all the cable connection before carrying the test.
10 RISK ASSESSMENT & CONTROL MEASURES
Only experienced and trained personnel to be deployed for this activity.
All personnel of the crew should be fully aware of the potential risk involved with the work.
At least one person in the crew shall be trained and be capable of providing first aid in case of
any electrical or non‐electrical accidents.
CIPL/GAIL/JHBDPL BAPL‐ SEC‐ DATE : 17.02.2020
TITLE : COATING INTEGRITY SURVEY
II/TCP/PRO/M15/02 PAGE : 4 / 7
GAIL ( INDIA ) LIMITED
All Measuring & Test Equipment’s used must be properly maintained and shall have valid
calibration from NABL authorised labs.
Use PPE (Personal Protective Equipment), i.e. Helmets, Shoes, Aprons and Goggles, gloves
during working at site.
Workers should be cautious, on slippery grounds.
Safety procedures shall be followed during construction activities in line with the Project HSE
procedure
11 PRECAUTION
Check Battery Voltage prior to commencement of survey.
Check all connections for proper tightness and polarities.
12 ITP AND INSTALLATION REPORT
Record and document all inspection and installation results obtained in the standard report format
approved by M/s. MECON.
13 MITIGATION PLAN CRITERIA
Average Specific Coating Resistance Average Specific Coating Conductance
Quality of Coating
( Ohm‐m2 ) ( Siemans/m2 )
Excellent >108 < 1 x 10‐8
Good 2 x 104 to 108 1 x 10‐4 to 5 x 10‐8
Fair 103 to 2 x 104 5 x 10‐4 to 1 x 10‐4
Poor <103 >1 x 10‐3
Bare ( Very Poor ) 10 ‐ 100 10‐1 to 10‐2
*Tabel Ref . As per mecon spefication
If calculated specific coating resistance is observed poor or very poor criteria then, we will provide
cathodic protection according to calculation to fulfill adequate protection till the PCP
commissioning .
As per mecon specification average specific resistance shall be min 108 Ohm‐m2.
CIPL/GAIL/JHBDPL BAPL‐ SEC‐ DATE : 17.02.2020
TITLE : COATING INTEGRITY SURVEY
II/TCP/PRO/M15/02 PAGE : 5 / 7
GAIL ( INDIA ) LIMITED
INSPECTION AND TEST PLAN FOR COATING INTEGRITY TEST
BOKARO‐ANGUL SECTION II OF JAGDISHPUR‐HALDIA‐BOKARO‐DHAMRA
PROJECT
PIPELINE PROJECT (JHBDPL) PH‐II
CLIENT M/S. GAIL (INDIA) LIMITED
CONSULTANT M/S. MECON LIMITED.
CONTRACTOR M/S. CORRTECH INTERNATIONAL PVT. LTD.
DATE
ITP NO
Reference Document Contract Specifications & Approved Design
Personnel Responsible CIPL: Site Engineer / Supervisor /Site Incharge
SR. NO. ACTIVITY CIPL MECON / GAIL
1 APPROVAL OF PROCEDURE S R &A
2 SURVEY AT SITE P W
3 MEASURING OF POTENTIAL & CURRENT P W
4 REPORT P RW
LEGEND
A – APPROVAL / ACCEPTANCE P – PERFORMED BY
R – REVIEW OF RECORD RM – RANDOM CHECK
RW – RANDOM WITNESS S – SUBMITTED BY
CIPL MECON/GAIL
NAME
SIGN
DATE
CIPL/GAIL/JHBDPL BAPL‐ SEC‐ DATE : 17.02.2020
TITLE : COATING INTEGRITY SURVEY
II/TCP/PRO/M15/02 PAGE : 6 / 7
GAIL ( INDIA ) LIMITED
INSPECTION AND TEST PLAN FOR COATING INTEGRITY TEST
PROJECT BOKARO‐ANGUL SECTION II OF JHBDPLPH‐II
CLIENT M/S. GAIL (INDIA) LIMITED
CONSULTANT M/S. MECON LIMITED.
CONTRACTOR M/S. CORRTECH INTERNATIONAL PVT. LTD.
REPORT NO DATE
SR. NO. ACTIVITY TEST RESULT REMARKS
1 LOCATION /CHAINAGE OF HDD CROSSING
2 DIAMATER OF HDD DECTION ( Inch )
3 LENGTH OF HDD SECTION ( Mtr )
4 APPLIED CURRENT – Ic ( mA )
5 ENTRY SIDE POTENTIAL ‐ E1 ON POTENTIAL ( mV )
6 ENTRY SIDE POTENTIAL ‐ E1 OFF POTENTIAL ( mV )
7 REMOTE SIDE POTENTIAL ‐ E2 ON POTENTIAL ( mV )
8 REMOTE SIDE POTENTIAL ‐ E2 OFF POTENTIAL ( mV )
9 ∆E1 POTENTIAL ( mV )
10 ∆E2 POTENTIAL ( mV )
11 AVERAGE POTENTIAL ∆Eavg ( mV )
12 SURFACE AREA S.A ( m2 )
13 COATING RESISTANCE , Rc
14 SPECIFIC COATING RESISTANCE , rc ‘
CIPL MECON/GAIL
NAME
SIGN
DATE
Average Specific Coating Resistance
Quality of Coating Final Result
( Ohm‐m2 )
Excellent 100000000 (108)
Good 10000 – 100000000 (104 – 108)
Fair 1000 – 10000 (103 – 104)
Poor < 1000 (103)
Bare ( Very Poor ) 10 ‐ 100