2 Measurement+and+Error
2 Measurement+and+Error
An engineer has to make a lot of measurements, collect and analyze data, and make decisions
about the validity of his approaches and procedures. He must have a clear idea about the
results he is going to obtain. In this respect, he may develop models of his expectations and
compare the outcomes from the experiments to those from the model. He uses various
measuring instruments whose reliabilities have outmost importance in successes of his
decisions. Characteristics of measuring instruments that are used in selecting the proper ones
are reviewed in the first section. Section 2 deals with analyses of measurement data. Section 3
handles the analyses of uncertainties and establishment of engineering tolerances.
Accuracy: closeness to the true value; closeness with which an instrument reading
approaches the true or accepted value of the variable (quantity) being measured. It is
considered to be an indicator of the total error in the measurement without looking into the
sources of errors.
Sensitivity: the ability of the measuring instrument to respond to changes in the measured
quantity. It is expressed as the ratio of the change of output signal or response of the
instrument to a change of input or measured variable.
Resolution: the smallest change in measured value to which the instrument will respond, i.e.
the smallest incremental quantity that can be reliably measured.
Linearity: the percentage of departure from the linear value, i.e., maximum deviation of the
output curve from the best-fit straight line during a calibration cycle.
Tolerance: maximum deviation allowed from the conventional true value. It is not possible to
build a perfect system or make an exact measurement. All devices deviate from their ideal
(design) characteristics and all measurements include uncertainties (doubts). Hence, all
devices include tolerances in their specifications. If the instrument is used for high-precision
applications, the design tolerances must be small. However, if a low degree of accuracy is
acceptable, it is not economical to use expensive sensors and precise sensing components.
Output B = B2 Output A = A2
Input A
Measuring Output
Input B Device
B = B1 A = A1
O/p
Input A Input B
Output (o/p) =
Sensitivity (S) x input (i/p)
Non-linear i/p-o/p relation Linear i/p-o/p relation
S = ∂(output)/∂(input) ........................................................................................(2.1)
2.1.3.1. Accuracy
Accuracy is defined as the degree of conformity of a measured value to the true (conventional
true value – CTV) or accepted value of the variable being measured. It is a measure of the
total error in the measurement without looking into the sources of the errors. Mathematically
it is expressed as the maximum absolute deviation of the readings from the CTV. This is
called the absolute accuracy.
absolute accuracy
Re lative accuracy = ; ........................................................... (2.3)
CTV
Percentage(%) accuracy = relative accuracy ×100 ............................................ (2.4)
Example 2.1
A voltmeter is used for reading on a standard value of 50 volts, the following readings are
obtained: 47, 52, 51, 48
2.1.3.2. Precision
Precision is composed of two characteristics as conformity and the number of significant
figures.
Conformity
The conformity is the ability of an instrument to produce the same reading, or it is the degree
of agreement between individual measurements. So, it is also called repeatability or
reproducibility.
2.1.3.3. Bias
The difference between CTV and average value (VAV) is called the bias. Ideally, the bias
should be zero. For a high quality digital voltmeter, the loading error is negligible yielding
bias very close to zero.
Pr = max {(49.5 – 47), (52 – 49.5)} = 2.5 volts. Thus, Bias = 50 – 49.5 = 0.5 volt.
A consistent bias can be due to the presence of a systematic error or instrument loading.
Hence, eliminating the causes removes the bias. However, if the bias is consistent and causes
cannot be identified and/or eliminated, the bias can be removed by re-calibrating the
instrument.
Example 2.2
A known voltage of 100 volts (CTV = 100 V) is read five times by a voltmeter and following
readings are obtained: 104, 103, 105, 103, 105
Pr = max {(VAV – VMIN), (VMAX – VAV)} = max {(104 – 103), (105 – 104)} = 1 volt
Accuracy = max {(CTV – VMIN), (VMAX - CTV)} = max {(100 – 103), (105 – 100)} =5 V
If we re-calibrated the instrument to remove the bias, then the average reading = CTV.
The new readings would be 100, 99, 101, 99, 101
Hence, after re-calibration, average = CTV = 100 volts, and accuracy = precision = 1 volt.
the accuracy of the two meters may be quite different. To determine which meter is in error, a
comparison measurement with a standard meter should be made.
Accuracy refers to the degree of closeness or conformity to the true value at the quantity
under measurement. Precision refers to the degree of agreement within a group of
measurements or instruments. The target-shooting example shown in figure 2.2 illustrates the
difference. The high accuracy, poor precision situation occurs when the person hits all the
bullets on a target plate on the outer circle and misses the bull’s eye. In the second case, all
bullets hit the bull’s eye and spaced closely enough leading to high accuracy and high
precision. The bullet hits are placed symmetrically with respect to the bull’s eye in the third
case but spaced apart yielding average accuracy but poor precision. In the last example, the
bullets hit in a random manner, hence poor accuracy and poor precision.
The scatter graph in figure 2.3 shows an alternative way of presenting the accuracy and
precision. Same quantity was measured three times by 5 different analyst or methods or
measuring instruments. Distribution of readings around the true value indicates the most
accurate, most precise and least accurate and least precise readings. The last reading is too far
away from the true value and from other readings that may indicate a systematic error.
Most
6
accurate
5 and precise
4
true value
3
Systematic
2 Worst error?
precision
1
0
0 1 2 3 4 5
analyst or different methods or measuring devices
Too often the beginning student is inclined to accept instrument readings at face value.
He is not aware that the accuracy of a reading is not necessarily guarantied by its precision. In
fact, good measurement technique demands continuous skepticism as to the accuracy of the
results.
In critical work, good practice dictates that the observer make an independent set of
measurements, using different instruments or different measurement techniques, not subject to
the same systematic errors. He must also make sure that the instruments function properly and
are calibrated against a known standard, and that no outside influence affects the accuracy of
his measurements.
It is customary to record a measurement with all the digits of which we are sure nearest to
the true value. For example in reading a voltmeter, the voltage may be read as 117.1 V. This
simply indicates that the voltage, read by the observer to best estimation, is closer to 117.1 V
than to 117.0 V or 117.2 V. Another way of expressing this result is that it indicates the range
of possible error. The voltage may be expressed as 117.1 ± 0.05 V, indicating that the value of
the voltage lies between 117.05 V and 117.15 V.
When two or more measurements with different degrees of accuracy are added, the result
is only as accurate as the least accurate measurement. Consider the following example:
Example 2.3
Two resistors, R1 and R2, are connected in series. Individual resistance measurements using a
digital multimeter, yield R1 = 18.7 Ω and R2 = 3.624 Ω. Calculate the total resistance to the
appropriate number of significant figures.
SOLUTION
R1 = 18.7 Ω (three significant figures)
R2 = 3.624 Ω (four significant figures)
RT = R1 + R2 = 22.324 Ω (five significant figures) = 22.3 Ω
The doubtful figures are written in italic. Any digit in the result is doubtful if it’s
computation involves doubtful digits. In the addition of R1 and R2 the last three digits of the
sum are doubtful figures. There is no value whatsoever in retaining the last two digits (the 2
and the 4) because one of the resistors is accurate only to three significant figures or tenths of
an ohm. The result should therefore also be reduced to three significant figures or the nearest
tenth. i.e., 22.3 Ω. Note that if extra digits accumulate in the answer, they should be discarded
or rounded off. In the usual practice, if the digit in the first place to be discarded (most
significant of digits to be discarded) is less than five, it and the following digits are dropped
from the answer as it was done in the example. If the digit in the first place to be discarded is
five or greater, the previous digit is increased by one. For three-digit precision, therefore,
22.324 should be rounded off to 22.3; and 22.354 to 22.4.
errors is a first step in finding ways to reduce them. Such a study also allows us to determine
the accuracy of the final test result. Errors may come from different sources and are usually
classified under three main headings as:
Gross errors: largely human errors, among them misreading of instruments, incorrect
adjustment and improper application of instruments, and computational mistakes.
Figure 2.6 provides a schematic summary of errors and their possible means of
elimination. For example, errors caused by the loading effect of the voltmeter can be avoided
by using it intelligently. A low-resistance voltmeter should not be used to measure voltages at
the input of a voltage amplifier. In this particular measurement, a high-input impedance
voltmeter (such as a digital voltmeter - DVM) is required. Gross and systematic errors cannot
be treated mathematically. They can be avoided only by taking care in reading and recording
the measurement data. Good practice requires making more than one reading of the same
quantity, preferably by a different observer. Never place complete dependence on one reading
Characteristics of Measuring Instruments / 9
but take at least three separate readings, preferably under conditions in which instruments are
switched off-on.
The error may be originated from the sampling of the source, preparation of the samples
Measurement errors
How to estimate:
How to estimate: How to estimate: Take many readings
Not possible to estimate
1. Compare with more Careful monitoring of and apply statistical
their value
accurate standards changes in the analysis to unexplained
mathematically
2. Determine if error is variables. Calculating variations
constant or a expected changes.
proportional error
Methods of elimination or
reduction: Methods of reduction Methods of reduction or Methods of
1. Careful attention to or elimination: elimination: reduction:
detail when making 1. Careful calibration 2. Hermetically seal 1. Careful design
measurements and of instruments. equipment and of measurement
calculations. 2. Inspection of components under test. apparatus to
2. Awareness of equipment to ensure 3. Maintain constant reduce unwanted
instrument limitations. proper operation. temperature and interference.
3. Use two or more 3. Applying humidity by air 2. Use of statistical
observers to take critical correction factors conditioning. evaluation to
data. after finding 4. Shield components determine best
4. Taking at least three instrument errors. and equipment against true estimate of
readings or reduce 4. Use more than one stray magnetic fields. measurement
possible occurrences of method of measuring 5. Use of equipment that readings.
gross errors. a parameter. is not greatly effected
5. Be properly motivated by the environmental
to the importance of changes.
correct results.
and measurement and analysis of the measurand. Care must be taken so that the sample is
representative of the whole population (homogeneous vs. heterogeneous). No unwanted
additions or deletions are allowed during the preparatory phase. Finally, calibration of the
measuring instrument using standard measurands or standard solutions is done as frequent as
defined by the equipment manufacturer. One way to assess total error is to treat a reference
standard as a sample. The reference standard would be carried through the entire process to
see how close the results are to the reference value.
x1 + x2 + x3 + + xn ∑ x
x= = ........................................................................ (2.7)
n n
Example 2.4
A set of independent current measurements was taken by six observers and recorded as 12.8
mA, 12.2 mA, 12.5 mA, 13.1 mA, 12.9 mA, and 12.4 mA. Calculate the arithmetic mean.
2.2.2. Deviation from the Mean Table 2.1. Deviations around mean
In addition to knowing the mean value of a series of d1 = 12.8 - 12.65 = 0.15 mA
measurements, it is often informative to have some idea d2 = 12.2 - 12.65 = -0.45 mA
of their range about the mean. Deviation is the departure d3 = 12.5 - 12.65 = -0.15 mA
of a given reading from the arithmetic mean of the group d4 = 13.1 - 12.65 = 0.45 mA
called d1, and that of the second reading, x2 is called d2 d6 = 12.4 - 12.65 = -0.25 mA
D=
d1 + d 2 + d 3 + + d n
=
∑d .................................................................. (2.9)
n n
Example 2.5
The average deviation for the data given in the above example:
0.15 + 0.45 + 0.15 + 0.45 + 0.25 + 0.25
D= = 0.283mA
6
data is the square root of the sum of all the individual deviations squared, divided by the
number of readings minus one. Expressed mathematically:
σ=
d12 + d 22 + d32 + + d n2
=
∑d i
2
............................................................ (2.10)
n −1 n −1
Another expression for essentially the same quantity is the variance or mean square
deviation, which is the same as the standard deviation except that the square root is not
extracted. Therefore
variance (V) = mean square deviation = σ2 ........................................................ (2.11)
The variance is a convenient quantity to use in many computations because variances are
additive. The standard deviation however, has the advantage of being of the same units as the
variable making it easy to compare magnitudes. Most scientific results are now stated in terms
of standard deviation.
20
16
Tabulation of Voltage Readings
Number of Observed Readings
Voltage reading
12
(volts) # of reading
99.7 1
99.8 4 8
99.9 12
100.0 19
100.1 10 4
100.2 3
100.3 1
0
99.6 99.8 100.0 100.2 100.4
Volts
Figure 2.7. Distribution of 50 voltage readings.
Analyses of Measurement Data / 13
the nearest 0.1 V. The nominal value of the measured graphically in the form of a block
diagram or histogram in which the number of observations is plotted against each observed
voltage reading. The histogram and the table data are given in figure 2.7. The figure shows
that the largest number of readings (19) occurs at the central value of 100.0 V while the other
readings are placed more or less symmetrically on either side of the central value. If more
readings were taken at smaller increments, say 200 readings at 0.05-V intervals, the
distribution of observations would remain approximately symmetrical about the central value
and the shape of the histogram would be about the same as before. With more and more data
taken at smaller and smaller increments, the contour of the histogram would finally become a
smooth curve as indicated by the dashed line in the figure. This bell-shaped curve is known as
a Gaussian curve. The sharper and narrower the curve, the more definitely an observer may
state that the most probable value of the true reading is the central value or mean reading.
For unbiased experiments all observations include small disturbing effects, called random
errors. Random errors undergo a Normal (Gaussian) law of distribution shown in figure 2.8.
1 x2
Pr obability of error = exp(− )
2π σ 2σ
Probability of Error
Figure 2.8. The error distribution curve for a normal (Gaussian) distribution.
They can be positive or negative and there is equal probability of positive and negative
random errors. The error distribution curve indicates that:
standard deviations above and below ( x ± 2 SD) covers about 95% of the observations. A
range of 3 standard deviations above and below ( x ± 3 SD) covers about 99.72% of the
observations.
This value is probable in the sense that there is an even chance that any one observation
will have a random error no greater than ±r. Probable error has been used in experimental
work to some extent in the past, but standard deviation is more convenient in statistical work
and is given preference.
Example 2.6
Ten measurements of the resistance of a resistor gave 101.2 Ω, 101.7 Ω, 101.3 Ω, 101.0 Ω,
101.5 Ω, 101.3 Ω, 101.2 Ω, 101.4 Ω, 101.3 Ω, and 101.1 Ω. Assume that only random errors
are present. Calculate the arithmetic mean, the standard deviation of the readings, and the
probable error.
SOLUTION: With a large number of readings a simple tabulation of data is very convenient
and avoids confusion and mistakes.
d2 0.36
Standard deviation, σ = = = 0.2 Ω
n −1 9
Probable error = 0.6745 σ = 0.6745 x 0.2 = 0.1349 Ω
minimize their effects. One of their primary causes can be pinpointed to instrument limit of
error and least count. The least count is the smallest division that is marked on the instrument.
The instrument limit of error is the precision to which a measuring device can be read, and
is always equal to or smaller than the least count. The estimation of the uncertainty is
important. For example, assume a volt meter may give us 3 significant digits, but we observe
that the last two digits oscillate during the measurement. What is the error? Average deviation
or standard deviation based on repeated measurements of the same quantity are used in
determining the uncertainty.
Example 2.7
An analog voltmeter is used to measure a voltage. It has 100
5.8 6.0 6.2
divisions on the scale. The voltage read is 6 volts and the
meter has two ranges as 0 – 10 volts and 0 – 100 volts. Find
4 6 8 the uncertainty in the measured value in both ranges.
Uncertainty = ± ½ VFSD / # of divisions, where VFSD is the
Figure for example 2.7. voltage measured at full-scale deflection of the meter.
On 10 V range, uncertainty = ± ½ 10 / 100 = ± 0.05 V
Analyses of Measurement Data / 17
where x1, x2, x3, … , xn are independent variables. Each variable is defined as
R = R ± ∆R ........................................................................................................ (2.15)
n
∂f
∆R = ω R = ∑ [ ]o ∆xi ................................................................................... (2.16)
i =1 ∂xi
∂f
where ( ) o is the partial derivative of the function with respect to xI calculated at the
∂xi
nominal value. The absolute value is used because some of the partial derivatives may be
negative and would have a canceling effect. If one of the partial derivative is high compared
to the others, then a small uncertainty in the corresponding variable has large effect on the
total error. Hence, the equation also illustrates which of the variable exerts strongest influence
on the accuracy of the overall results.
Example 2.8
The voltage generated by a circuit is equally dependent on the value of three resistors and is
given by the following equation: V0 = I(R1R2/R3)
Uncertainty Analysis / 19
If the tolerance of each resistor is 1 per cent, what is the maximum error of the generated
voltage?
SOLUTION:
∂V0 R V ∂V R V ∂V RR V
Let us find the sensitivities first. = I 2 = 0 ; 0 = I 1 = 0 ; 0 = −I 1 2 2 = − 0
∂R1 R3 R1 ∂R2 R3 R2 ∂R3 R3 R3
All tolerances are given as 1%, therefore: ∆R1 = 0.01R1 ; ∆R2 = 0.01R2 ; ∆R3 = 0.01R3
∂V0 ∂V ∂V
∆V0 = ∆R1 + 0 ∆R2 + 0 ∆R3 That yields ∆V0 = 0.03V0
∂R1 ∂R2 ∂R3
The total variation of the resultant voltage is ±0.3 per cent, which is the algebraic sum of
the three tolerances. This is true in the first approximation. The maximum error is slightly
different from the sum of the individual tolerances. On the other hand, it is highly unlikely
that all three components of this example would have the maximum error and in such a
fashion to produce the maximum or minimum voltage. Therefore, the statistical method
outlined below is preferred.
i =1 ∂xi
This will be used throughout the course unless the question asks the limiting error, or
maximum possible uncertainty.
Example 2.9
P = VI, if V = 100 ± 2 volt (measured) and I = 10 ± 0.2 Amp (measured), determine the
maximum allowable uncertainty, and the expected uncertainty in power.
∂P ∂P
SOLUTION: ∆Pm = wPm = ∆V + ∆I = 10 x 2 + 100 x0.2 = 40 watts is the limiting
∂V ∂I
value of the uncertainty.
∂P ∂P
However, the expected uncertainty ∆P = wP = ( ∆V ) 2 + ( ∆I ) 2
∂V ∂I
Example 2.10
The resistance of a certain size of copper wire is given by R = Ro[1 + α (T − 20)] . The
resistance at 20°C is Ro = 6Ω ± 0.3%, temperature coefficient α = 0.004/°C ± 1%,
temperature T = 30°C ± 1°C. Compute the uncertainty in the resistance R.
then
ω R 2 2 ωY 2 2 ωY 2 2 ωY 2
( ) = l ( ) + n ( ) + k ( ) ........................................................................ (2.19)
1 2 3
Ro Y1o Y2 o Y3o
Series analysis
Rs = R1 + R2 ; ∂Rs/∂R1 = ∂Rs/∂R2 = 1; Rs = R1 + R2 = 10 + 10 = 20Ω
Uncertainty Analysis / 21
∆Rs ∆R 1 1
The limiting error (maximum uncertainty) = ∆Rsm = ∆R1 + s ∆R2 = + = 1Ω
∆R1 ∆R2 2 2
∆Rs 2 ∆R
The uncertainty: (∆Rs ) 2 = ( ) (∆R1 ) 2 + ( s ) 2 (∆R2 ) 2 = (1) 2 ( 12 ) 2 + (1) 2 ( 12 ) 2 = 14 + 14 = 1
∆R1 ∆R2 2
R1 R2 R1
R2
Two resistors in series.
yielding ∆Rs ≈ 0.7Ω . The relative uncertainty = 0.7/20 = 0.035, and the percentage
uncertainty = 3.5%. Therefore, Rs = 20Ω ± 0.7Ω = 20Ω ± 3.5%
Parallel analysis
RR 10x10
R p = 1 2 = R p ± ∆R p ; R p = = 5Ω
R1 + R2 10 + 10
∂R p ( R1 + R 2 ) ) R 2 − R1 R 2 R2
2
= =
∂R1 ( R1 + R 2 ) 2 ( R1 + R 2 ) 2
∂R p ( R1 + R 2 ) ) R 2 − R1 R 2 R2
2
∂R p ( R1 + R2) ) R1 − R1R2 R1
2
= = = =
∂R1 ( R1 + R 2 ) 2 ( R1 + R 2 ) 2 ∂R2 ( R1 + R2 ) 2 ( R1 + R2 ) 2
∂R p 102 100 1 ∂R p
Hence, = = = =
∂R1 (10 + 10) 2
400 4 ∂R2
∂R p ∂R p 1 1 1 1 1 1 1
(∆R p ) 2 = ( ) 2 (∆R1 ) 2 + ( ) 2 (∆R2 ) 2 = ( ) 2 ( ) 2 + ( ) 2 ( ) 2 = ( )( )(1 + 1) =
∂R1 ∂R2 4 2 4 2 16 4 32
1
Therefore the uncertainty in Rp is : ∆R p = = 0.175Ω
32
The nominal value of Rp = 5Ω, the percentage uncertainty = (0.175/5)x100=3.5%
Then Rp = 5 ± 0.175 Ω = 5Ω ± 3.5%
1 1 1
Limiting error in Rp = ( + ) = 0.25Ω
4 2 2
Population Sample
2.3.4. Sample and Population Statistics
In many instances, we take samples from a population
and infer the population statistics as illustrated in figure
2.10. Suppose we want to know the average weight of
adults. It is not feasible to weigh every single adult and
then take the average of all the weights. All adults are Figure 2.10. Population and sample
called the population. Instead, we decide to take a small fraction of the adults, say 1 out of
every 1000, and average these weights. This small fraction is called our sample population.
Now we have an average weight for our sample population. We want to know if our sample
population average weight is a good estimation of the population average weight. In addition,
measurement is a costly process. Hence, we also want to know the minimum sample size that
yields uncertainties within the tolerance range.
Figure 2.11 illustrates the distribution for the population and the sample. For the
Frequency
δ
α
−σ µ +σ x
Mean
is the tail probability that xs does not differ from µ by more than δ.
Uncertainty Analysis / 23
σ population =
(deviations )2 =
∑ ( x – x)
i
2
.................................................................. (2.20)
n n
σ sample = σ s = s =
(deviations )2 = ∑ ( xi – x) 2 ......................................................... (2.21)
n −1 n –1
The sample standard deviation allows for more variation in the sample compared to the
population, since sample is only part of population. Dividing by (n-1) increases the estimate
of the population variation. This attempts to eliminate the possibility of bias.
The estimated sample standard deviation is a measure of the spread of data about the
mean. The standard deviation of the mean x is
σs
σx = .................................................................................................................... (2.23)
n −1
Equation 2.23 illustrates an important fact. The standard deviation doesn’t change much,
σs
but the error on the mean improves dramatically! It goes as ≈ , where n is the number of
n
measurements. As a rule of thumb, the range R of the random variable x can be roughly taken
as R ≈ 4σ. If Δ is the error that can be tolerated in the measurement, then the number of
2.4. PROBLEMS
2. A digital voltmeter uses 4½ digit display (it can display up to 19999). It is used to
measure a voltage across a standard cell whose value is 1.2341 volt 4 times and following
readings are obtained: 1.2202, 1.2115, 1.2456, 1.2218. Determine the accuracy, the precision
and the bias of the voltmeter.
CTV =1.2341 volt; VAV = 0.25x(1.2202 + 1.2115 + 1.2456 + 1.2218) = 1.2248V.
The accuracy = |1.2341 – 1.2115| = 0.0226V; % accuracy = 1.83% ,
pr = max[(1.2456 – 1.22248), (1.2248 – 1.2115)] = 0.0208 V;
Bias = |1.2341 – 1.2248| = 0.0093 V
3. A recently calibrated digital voltmeter is used to read a voltage and it consistently yields
75 volts. Another meter in the lab is also used five times to measure the same voltage and
following readings are obtained: 77, 75, 74, 76, 77. For the second meter,
a. Find the absolute accuracy, relative accuracy and percentage accuracy.
The recently calibrated meter presumably reads the conventional true value. Therefore
CTV = 75 V, yielding absolute accuracy = max {(77 - 75), (75 – 74)} = 2 volts,
The relative accuracy = 2/75 = 0.027,
The % accuracy = 2.7%
b. Find the precision.
VAV = (1/5)(77+75+74+76+77) = 75.8 volts. Pr = max {(77 – 75.8), (75.8 – 74)}=1.8V
c. Calculate the bias. Bias = VAV – VCTV = 75.8 – 75 = 0.8 volt.
V2
4. The gain of the amplifier is defined in dB by: G = 20 log 10 ( ) . Show that the
V1
ωV 2 ω V 2
uncertainty in the gain is given by: (ω G ) 2 = (20 log10 e) 2 [( ) +(
1
) ]
2
V1 V2
Hint: log10a = (logea)/(loge10) = (log10e)(logea) , logea = ln(a) and d(lnx)/dx = 1/x .
log10e = 0.434
V ∂G 1
G = 20 log10 ( 2 ) = (20 log10 e)[ln(V2 ) − ln(V1 ) ; = −20 log10 e and
V1 ∂V1 V1
∂G 1
= 20 log10 e yielding the uncertainty as defined above.
∂V2 V2
5. Five resistors are available, one of 20 Ω and four of 10 Ω each. The uncertainty of the 20
Ω resistor is 5% and that of each 10 Ω resistor is 10%. 3 possible connections using these
resistors are shown below. Which one would you use to obtain a 30 Ω resistance with the
least uncertainty? What is the uncertainty of this best connection?
Problems / 25
Limiting error = ∆Pm = 2IR∆I + I 2∆R = 2 x20 x10−3 x10 x103 x10−4 + 10−8 x50 ≅ 40mW
1 30
T= ( − 1) + 280 = 407.6 K ;
0.00392 20
1.5 2 −6 −6
(∆T )2 = 10− 4 + ( ) (10 + 10 ) = 0.29295 yielding ∆T = ± 0.54K
0.00392
∂R
d. Find the static sensitivity of the thermometer.
∂T
∂R
= α 0 R0 = 0.00392 x 20 x103 = 78.4 Ω
∂T K
e. Calculate the maximum error in T.
1 R 1.5
∆Tm = ∆T0 + ∆R + 2 ∆R0 = 0.01 + (0.001 + 0.001) = 0.7753K
α 0 R0 α 0 R0 0.00392
2.4.2. Questions
2.4.2.1. True-False
Please answer the following True or False questions.
Question True False
Systematic errors can be eliminated by recalibrating the equipment
Systematic errors can be eliminated by making multiple measurements
Accuracy of a measurement is an indication of how close the reading is
to the average value
Accuracy of a measurement is an indication of total errors in the
measurement
The smallest incremental quantity that can be measured is the resolution
The precision is an indicator of consistency in a set of measurements
The result of 10.5+ 1.267 (with significant figures only) is 11.8
Gross (human) errors can be treated mathematically
The current in a 10-Ω resistor is measured as 0.25 A ±1%. The power
dissipated by the resistor is 625 ± 12.5 mW.
1.
2.4.2.2. Multiple-Choice Questions
Please choose and CICRLE the most appropriate statement in the following questions
1. Gross (human) errors
a. Are due to equipment failures
b. Can be minimized by making multiple measurements
c. Can not be treated mathematically
d. Do not effect the accuracy of the measurement
2. Resolution is
a. An indicator of how close the reading to the true value
b. The smallest incremental quantity that we can identify
c. The difference between the minimum and maximum values of the measurement
d. The total error in the measurement
3. Systematic errors
a. Can not be treated mathematically
b. Can be eliminated by making multiple measurements
c. Indicate the accuracy of the measurement
Problems / 27
d. Are due to environmental factors upsetting the user and the equipment
4. Accuracy of a measurement is an indication of
a. How far the reading is away from the average value
b. How many digits we use to display the data
c. How close the reading is to the conventional true value
d. The smallest incremental quantity that we can identify
5. Precision is
a. An indicator of how close the reading is to the true value
b. The total error in the measurement
c. An indicator of how close the reading is to the average value
d. The smallest incremental quantity that we can identify
6. What is the result of 1.264+ 10.5 (use significant figures only)
a. 12
b. 11.8
c. 11.7
d. 11.764
7. Mathematical treatment of errors is possible for
a. Systematic and random errors
b. Human and systematic errors
c. Human and random errors
d. Errors that are small
2.4.2.3. General Questions
c. The value of the equivalent resistor and expected error in percent when the resistors
are connected in parallel.
6. The potential of an electrical power source is measured 12.47 volts by a recently
calibrated digital voltmeter. Two other voltmeters are used in the lab to measure the same
voltage by six different observers in a short interval of time and following results (in
volts) are recorded:
Meter-1: 11.456, 11.324, 11, 562, 11.243, 11.472, and 11.376
Meter-2: 12.45, 12.34, 12.67, 12.76, 12.21, and 12.54
a. Determine the resolution of each meter in volt. Which one has a better resolution?
b. Determine the accuracy and precision of each meter. How much is the bias in each
meter? Which one is more precise? Which one is more accurate?
7. The following values were obtained from the measurements for a resistor in ohms: 220.2,
119.5, 221.1, 119.9, 220.0, 220.5, 119.8, 220.1, 220.4, and 119.8. Calculate
a. The arithmetic mean
b. The average deviation
c. The standard deviation
d. The probable error of the average of the ten readings.
8. A metallic resistance thermometer has a linear variation of temperature with resistance as
1 R
T= ( − 1) + T0 . The temperature at R0 = 5 kΩ ± 1% is T0 =25°C ± 0.1°C, while at a T
α 0 R0
the resistance R is found to be R = 6 kΩ ± 1%. α0 = 0.004/°C.
a. Calculate the static sensitivity ∂T at R0 of the thermometer.
∂R
b. Calculate the nominal value of T.
c. Show that the limiting error ∆Tm in T is given by: ∆Tm = ∆T0 + 1 R [ ∆R0 + ∆R ]
α 0 R0 R0 R
d. Calculate the limiting error and uncertainty in T.
9. A digital thermometer is used to measure the boiling water whose temperature is 96.2°C.
The measurement is repeated 5 times and following readings are obtained: 95.9, 96.2, 96.5,
95.8, 96.1. Determine the percentile accuracy, the precision and the bias of the thermometer.
10. The following values were obtained from the measurements for the line voltage in
Jeddah: 125.2, 125.5, 126.1, 126.2, 126.0, 125.8, 125.7, 126.1, 126.3, and 125.6. Write down
the formulas and calculate
a. The arithmetic mean
b. The standard deviation and the probable error of the average of the ten readings.
11. The boiling temperature
of water is measured 15
times using two
thermometers A and B, and
the readings presented in the 95.9 96.2 96.5 96.0 96.3 96.6
graph are obtained.
Conventional value for the Thermometer – A Thermometer – B
boiling temperature of water Figure problem 11.
is 96.2°C.
a. Which thermometer
(A or B) is more precise, why?
b. Calculate the percentage accuracy and bias of thermometer – A.
Problems / 29
12. What is the addition of 12.5 and 1.364 with each having the last digit doubtful?
13. For the electronic counter show that the uncertainty in the period measurement can be
1
reduced by a factor of if the average of N time periods is taken. Hint:
N
1
TAV = (T1 + T2 + ⋅ ⋅ ⋅ + TN ) The TI’s are statistically independent, Ti = T ± ωT ,∀i
N
14. What is the systematic error, from where it comes and how it can be eliminated?
15. Three resistors are in series. The values are (in kΩ) 47.23, 2.205, and 180.2, with an
uncertainty of one digit in the last place. Find the total resistor and express the result using
significant figures only.
16. The potential of an electrical power source is measured 124.7 volts by a recently
calibrated digital voltmeter. A voltmeter in the lab is used to measure the same voltage by
six different observers in a short interval of time and following results (in volts) are
recorded: 124.5, 123.4, 126.7, 127.6, 122.1, and 125.4. For the meter in the lab, determine
the resolution in volt, the accuracy, the precision, and the bias?
17. Two resistors have values R1 = 56 Ω ± 5% and R2 = 120 Ω ± 2% Calculate
a. The magnitude of error in each resistor
b. The limiting error in ohms and in percent when the resistors are connected in series.
c. The value of the equivalent resistor and expected error in percent when the resistors
are connected in parallel.
18. There are 1500 chickens in a poultry farm. 15 chickens are randomly selected and
weighted. The average value is 950 grams and the standard deviation is 60 grams.
a. How much is the error expected in the average value?
b. How many chickens we will have weighing between 890 grams and 1010 grams?
c. How many chickens must be weighted to reduce the error in the average value down
to 5 grams?
Measurement & Error / 30