Determine:
a) The rejected power to the atmosphere in MW
𝑸𝑳 = 𝑸𝑯 − 𝑾 = 𝟏𝟎𝟎𝟎𝑴𝑾 − 𝟏𝟓𝟎 = 𝟖𝟓𝟎𝑴𝑾
𝑸𝑳 = 𝟖𝟓𝟎𝑴𝑾
b) How much air should be flowed to the cooling tower (kg/s) if its temperature cannot be
increased more than 10oC.
𝑸°𝑳 = 𝒎°𝒂𝒊𝒓 ∗ ∆𝒉 = 𝒎°𝒂𝒊𝒓 ∗ 𝒄𝒑 ∗ ∆𝑻
𝒌𝑱
Using table A-2, we can find 𝒄𝒑 for air to be 𝒄𝒑 = 𝟏, 𝟎𝟎𝟓
𝒌𝒈∗𝑲
2- Water at T= 10°C, P = 200 kPa flowing at 0.1 kg/s is heated to 40°C in a constant-pressure
heat exchanger. The energy is supplied by a heat pump with a coefficient of performance of
COPHP= 2.5.
𝑻𝟏 = 𝟏𝟎℃
𝑷 = 𝟐𝟎𝟎𝒌𝑷𝒂
𝒌𝒈⁄
𝒎° = 𝟎, 𝟏 𝒔
Bogdan Sipos
267526
𝑻𝟐 = 𝟒𝟎℃
𝑪𝑶𝑷𝑯𝑷 = 𝟐, 𝟓
Determine:
1- The the amount of heat power that the water received from the heat exchanger assume that
there is no heat desipated to the atmosphere.
𝒌𝑱
Using table A-3, we can find 𝒄𝒑 for water to be 𝒄𝒑 = 𝟒, 𝟏𝟖
𝒌𝒈∗𝑲
𝑸𝑯 = 𝒎° ∗ (𝒉𝟏 − 𝒉𝟐 ) = 𝒎° 𝒄𝒑 ∗ ∆𝑻
∆𝑻 = 𝟒𝟎℃ − 𝟏𝟎℃ = 𝟑𝟎℃ = 𝟑𝟎𝑲
𝒌𝒈 𝒌𝑱
𝑸𝑯 = 𝟎, 𝟏 ∗ 𝟒, 𝟏𝟖 ∗ 𝟑𝟎𝑲 = 𝟏𝟐, 𝟓𝟒𝑲𝑾
𝒔 𝒌𝒈 ∗ 𝑲
2- Find the required power to drive the heat pump.
𝑸𝑳
𝑪𝑶𝑷𝑯𝑷 =
𝑸𝑯 − 𝑸𝑳
𝑸𝑳
𝟐, 𝟓 =
𝟏𝟐, 𝟓𝟒 − 𝑸𝑳
𝑸𝑳 = 𝟖, 𝟗𝟔𝒌𝑾
𝑾 = 𝑸𝑯 − 𝑸𝑳 = 𝟏𝟐, 𝟓𝟒𝒌𝑾 − 𝟖, 𝟗𝟔 = 𝟑, 𝟓𝟖𝒌𝑾