Spool Piece
Ultrasonic Flowmeter (FST)
for liquid applications
21A1-E-0089a
Unparalleled Accuracy for Optimal Performance Precision Measurements for
Various Liquids
Precision measurement of flow helps reduce costs and energy consumption
Three Pairs of Sensors for Accuracy of ±0.2% of rate Superior bubble resistance
Wetted sensors are used to deliver Measuring principle: parallel three-path, transit Fuji Electric’s advanced anti-bubble measurement
time difference method Flow
: V = K ‧ (T2 – T1) technology reduces the interference of air bubbles to
highly sensitive measurement. velocity
high-precision. With no obstruction The sensors placed on upstream and downstream emit ultrasonic
Flow coefficient :K
pulse in turn, and detect the transit time difference of the pulse to
Normal propagation Propagation interrupted
inside pipe, no pressure loss is calculate the flow rate.
by bubbles
generated. Measurement failure may occur.
2 3
Designed for Ease-of-Use
Backlit LCD and Front Panel Operation Convenient Configuration and Data
Management from PC
Front keys allow you to configure parameters, enter
piping conditions, or calculate sensor spacing, without Parameter loader software, provided as standard,
opening the cover. Measurement results are shown on allows parameter setting and measurement data
the 16-digit 2-line LCD in Japanese, English, German, acquisition on PC. RS-485 communication is optionally
French, or Spanish. Self-diagnosis function tells you if available.
an error occurs.
Laptop
Green at normal,
red at error
A RS232C to RS485 converter is required.
Waterproof keypad If your PC does not support the RS232C serial interface, a USB to
RS232C converter is required.
Backlit LCD
Low Maintenance
Selectable Panel Position
The lack of projections inside keeps the pipe almost
You can select the most entirely free from contamination, thereby reducing
suitable panel position for maintenance work.
your application.
See “Mounting/wiring port position” on
Page 7. Flexible Output Terminal
Vertical mounting
Equipped with terminals for insulated 4–20 mA DC
analog output, pulse output, and alarm output.
Reliability
Zero point adjustment Damping Low flow cut-off
When the flow is stopped, the Used to reduce fluctuation of Output can be cut off when the
zero point can be adjusted with measured values. flow rate is low.
a single push of a button. Setting range: 0 to 100 s (in Setting range: 0 to 5 m/s (in
0.1 second steps) 0.01 m/s steps)
Safety
Event-triggered alarms Output burnout Flow switch Total switch
Alarm output is activated upon When there is no fluid in the Contact output is emitted when Contact output is emitted when
instances of hardware error pipe or there are air bubbles in the instantaneous flow rate has the total flow rate (forward
the fluid, the flowmeter holds
and/or process error. reached the high or low limit. direction) has reached the high
the analog output and emits a
contact output. limit.
Convenience
Unit selection Bi-directional range Auto-switchable ranges
m/s, L/s, L/min, L/h, L/d, KL/d, User can configure a range User-defined two ranges can
ML/d, m /s, m / min, m /h,
3 3 3 for each of forward flow and be switched automatically.
reverse flow. Operating range
m3/d, Km3/d, or Mm3/d can be emitted as contact
output.
4
Applications
of water consumption.
Building B
Main pipe
0
0
15 0
16 0
17 0
18 0
0
:0
:0
:0
:0
:0
:0
:0
:0
:0
:0
:0
8
9
10
11
12
13
14
Building A Building A Building B Building C
Reductions in power consumption are achieved by Optimal ratio of flow control for both pipes
using an inverter only, instead of a combination of
motorized valve and controller to control flow rate.
Motor SV
MV Flow rate
PV setting Controller
Inverter
System
Monitoring the flow rate at inlet and at outlet • Cooling/heating water and drainage in steel
enables you to manage the liquid level in a tank. plants, chemical plants, or air conditioning
systems
Controller • Purified water and drainage in water treatment
• Cooling water and hot water in boilers
• Various liquids in paper & pulp plants
Inlet • Cooling water in cement plants
• Cooling water, hot water and drainage in waste
Temperature
treatment plants
sensor
5
Dimensions (in mm)
9 142 9 (30)
142 (30) 75 75
Communication (RS485)
Communication (RS485)
33
33
36
36
Nameplate Nameplate
Power supply (AC) Power supply (AC)
170
170
ESC ENT ESC ENT
45
45
Ultrasonic Flowmeter Ultrasonic Flowmeter
H
B B
-Φ -Φ
N N
Φd
Φd
L
L
ΦC ΦC
ΦD ΦD
F
+1
T +1
T
W1 -3 W1 -3
W2 W2
6
Page
Page
: Page
: Page
: : ESC ENT
TAG.
TAG.
No.
TAG.
No.
TAG.
No. No.
POS.
POS.
No.
POS.
No.
POS.
No. No.
Ultrasonic Flowmeter
外外外
形外形形
図形図図図
OU
O TU
OTU
LOITU
LNITE
LNI ELNIEN E
E ESC ENT
Ultrasonic Flowmeter
Fuji Electric Co., Ltd.. They shall be neither reproduced, copied,
copied,
copied,
copied,
without
purposes without
purposes without
third party, nor used for the manufacturing purposes without
use of any
use of any
any
use of any
This material and the information herein is the property of
of
of
of
theproperty
property
property
of
AA A A BB B B C C code:
C C C) DD D code:
D D)
be neither reproduced,
be neither reproduced,
be neither reproduced,
purposes
Fuji ElectricforCo.,
forthe
the
forthe
manufacturing
manufacturing
manufacturing
herein is
herein is
herein is
Electric
11th code A B C D E
way whatsoever
wayofwhatsoever
whatsoever
any wayofwhatsoever
取付・配線方向
Fuji
形式12桁目
shall
shall
shall
way
EEE E
the
for the
for the
consent
in consent
ESC ENT
ESC ENT
ESC ENT
ESC ENT
written
水平取付/上流方向
B
or disclosed
or disclosed
disclosed
or disclosed
party, nor
party, nor
party, nor
水平取付/上流から見て右方向
lent, material
material
material
C
thirdElectric
thirdElectric
thirdElectric
lent,express
the express
or
Specifications
水平取付/上流から見て左方向
D
lent,
lent,
This
This
This
Fuji
Fuji
Fuji
the
垂直下→上/上流方向
E
取付
取付
・配線方向
取付
・配線方向
取付
・配線方向
・配線方向
Principle Transit time difference method (parallel 3-path)
Pipe size
形式12桁目
形式12桁目
形式12桁目内容内容内容内容
形式12桁目
Φ50 mm, Φ80 mm, Φ100 mm 名 称 スプール形超音波流量計 形 式 S
FWE
Flange ratingA A A
水平取付/下流方向
A
水平取付/下流方向
水平取付/下流方向
水平取付/下流方向
JIS10K/JIS20K, ANSI 150/300, DIN PN16/40 ARTICLE (一体型)
フランジ形 TYPE E
Accuracy 水平取付/上流方向
水平取付/上流方向
水平取付/上流方向
水平取付/上流方向
±0.2% of rate (flow velocity: 1 m/s to 10 m/s)
Dwg.No.
B B B B
TC5
Fluid pressure C C C
水平取付/上流から見て右方向
C
水平取付/上流から見て右方向
水平取付/上流から見て右方向
水平取付/上流から見て右方向
Up to flange rating
A4G1
Fluid temperature
D D D
水平取付/上流から見て左方向
D
水平取付/上流から見て左方向
水平取付/上流から見て左方向
水平取付/上流から見て左方向
-40°C to +150°C
Measuring range Flow velocity: 0 to ±0.3…..±10 m/s
垂直下→上/上流方向
垂直下→上/上流方向
垂直下→上/上流方向
垂直下→上/上流方向
E E E E
T CT5CT25C42
Zero point adjustment, damping, T514 21(
45(
Clow-flow
251
5405 0 1 /(
205 20/)
(
2 /)
2cutoff,
2 )2 ) output burnout, output limit, bi-directional
22 /alarm,
Functions
A4G1
A4G1
A4G1
A4G1 range, automatic two ranges, flow switch, total switch, preset total, data backup at power outage
Communication (option) RS-485
Data backup at power
On nonvolatile memory
outage
Power supply voltage 100–240 V AC, 50/60 Hz
Grounding D-class grounding with ground resistance of 100Ω or less
Arrestor Provided as standard, on power supply port and analog output port
Power consumption Approx. 20 VA
Ambient temperature -40°C to 60°C
Ambient humidity 90% RH or less
Waterproof IP66
Flow velocity: m/s
Unit
Flow rate: L/s, L/min, L/h, L/d, kL/d, ML/d, m3/s, m3/min, m3/h, m3/d, km3/d, Mm3/d
7