MOV91822_EPCe05-44A

HRV
Heat Reclaim
Ventilation

VAM-FA Series

VKM-GM Series

VKM-G Series

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

c o n t e n t s p. 3

Table of Contents

I NTRODUCTION 4

G ENERAL HRV F EATURES 6


Energy Efficiency 6
Design Flexibility 7
Clean Air 9

VKM F EATURES 10
Energy Efficiency 10
Design Flexibility 11

L INE - UP 12

C ONTROL S YSTEMS 13
Individual Control Systems 13
Centralised Control Systems 16

S PECIFICATIONS 18
VAM-FA 18
VKM-GM 19
VKM-G 20

O PTIONS 21

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

Daikin
p. 4

i n t r o d u c t i o n

Daikin has a worldwide reputation based on over 70 years’

experience in the successful manufacture of high quality air

conditioning equipment for industrial, commercial and

residential use.

Daikin Europe N.V.

Environmental Consciousness
Enhancing the present - safeguarding the future
Throughout the last 50 years or so the basic building blocks of life - air, water and the earth - have been
systematically subjected to increasing levels of pollution with little regard to their potentially devastating
effects on future generations.

Recently however, concern has grown regarding climate changes, acid rain, water and air pollution and
the constant degradation of Earth’s natural resources. The very technology that created these problems is
now being harnessed to halt and reverse them. Depletion of the ozone layer and global warming have
been highlighted and are now being addressed. Government legislation prohibiting the use of toxic
substances and the generation of pollutants has slowed down the destruction of the environment.

Daikin Europe is proud to have been pro active in this respect, closely following its Japanese parent in
implementing policies that have often pre-empted official legislative codes and directives. As a result, a
culture of “environmental management” has since 2001, played a key role in the company’s day to day
activities and development strategies.

Top management commitment is reflected in the establishment of a number of action plans, which are
now strictly observed and implemented throughout the Daikin Group.

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 5

HRV helps create a high quality environment by interlocking with the air
conditioning system

The Daikin HRV (Heat Reclaim Ventilation) recovers heat energy lost through
ventilation and holds down room temperature changes caused by
ventilation, thereby maintaining a comfortable and clean environment. This
also reduces the load on the air conditioning system and conserves energy.

In addition, the HRV interlocks with Daikin’s VRV system, Sky Air and other air
conditioning systems and automatically switches over ventilation mode,
further increasing the effects of energy conservation. HRV operation has
been centralised on the air conditioner remote control allowing total
control over air conditioning and ventilation via a simple configuration.

The current line-up includes models with DX coil and/or humidifier - the DX
coil helps prevent the direct impact of cold airflow upon personnel during
the heating cycle and vice versa. High static pressure enhances design
flexibility.

Components of Indoor Air Quality

Ventilation
Humidi-
fication
HRV

Airflow

New Features VKM unit

• Humidifier
• DX coil
• High static pressure

Line-up

Air flow rate (m3/h) 150 250 350 500 650 800 1000 1500 2000

VAM-FA
Ventilation
VKM-GM:
Ventilation, DX coil
& humidifier
VKM-G:
Ventilation & DX coil

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 6

g e n e r a l H R V f e a t u r e s

II. General HRV (VAM+VKM)


Features
1.
1 E NERGY E FFICIENCY

• Over 30 % Size Reduction


Use of the high efficiency paper (HEP) element and optimized design of the fan and airflow
passages have resulted in matchless compactness without detriment to the 28% or so reduction
in air conditioning load achieved by previous models. A reduction of up to 40mm in height
allows the main unit to fit easily into limited spaces such as ceilings
On average 28 % air conditioning load reduction (maximum 40 %):
- 20% by operating in total heat exchange mode (in comparison with normal ventilation fans)
- a further 6 % by auto-ventilation mode changeover switching
- a further 2 % by pre-cool, pre-heat control (reduces air conditioning load by not running the
HRV while air is still clean soon after the air conditioner is switched on.)
Note: the values mentioned above may vary according to weather and other environmental conditions at the location of the unit’s
installation

• Proprietary Developed HEP Element


The heat exchange element uses a high efficiency paper (HEP) possessing
superior moisture absorption and humidifying properties.
The heat exchange unit speedily recovers heat contained in latent heat
(vapour). The element is made of a material with flame resistant properties
and is treated with an anti-moulding agent.

Operation of the heat exchanger element

Outdoor Indoor
30.6°C
62% RH
SA
27.4°C
63% RH

SA
Temperature Integrally-
and humidity formed liner
RA RA
26°C
50% RH
32°C
70% RH
Integrally-formed liner

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

d e s i g n f l e x i b i l i t y p. 7

• Automatic Changeover to Efficient Operation Patterns


Operation automatically switches to the optimum pattern to suit prevailing conditions

Cooling In between (bypass ventilation) Heating


Heat exchanger element Heat exchanger element
Exhaust fan Damper (heat recovery) (heat recovery)

EA RA EA RA EA RA
Automatic Automatic
changeover changeover
OA SA OA SA OA SA

Air supply fan DX coil (cooling) DX coil (heating) Humidifying

2.
2 D ESIGN F LEXIBILITY

• Outdoor Operation Temperature down to -15°C


If the outdoor air suction temperature falls below -10°C, the unit switches to intermittent
operation to prevent freezing of the heat exchanger element and dew condensation within the
unit.
Intermittent operation = a thermistor (standard equipment) within the unit detects the outdoor
air temperature. Unit operation varies according to the detected temperature.

• Slim Design
The slim design of the HRV unit enables it to be mounted in narrow ceiling voids and irregularly
shaped spaces.

269mm VAM250FA

• Installation under the floor of a small building • Installation under a beam • Installation in an irregular space

348mm

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 8

d e s i g n f l e x i b i l i t y

• Simple Design and Construction


The unit can be installed either horizontally or vertically in accordance with the conditions of
the location.
A 450mm square inspection hatch enables maintenance and heat exchange element
replacement to be performed with ease.

Switch box

Access door

Maintenance cover

• Quiet Operation
Sound pressure levels are remarkable low at 20.5dBA (VAM150FA)

dB(A) Perceived loudness Sound

0 Treshold of hearing -
20 Extremely soft Rustling leaves
40 Very soft Quiet room Daikin units
60 Moderately loud Normal conversation
80 Very loud City traffic noise
100 Extremely loud Symphonic orchestra
120 Threshold of feeling Jet taking off

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

c l e a n a i r p. 9

3.
3 C LEAN A IR

• Fresh-Up Operation
The user can select between 2 fresh-up modes via the remote control

1. Supply rich mode: 2. Exhaust fresh-up:


Raising the air supply maintains proper room Raising exhaust air decreases room pressure to
pressure to prevent back-flow of toilet/kitchen prevent the leaking of odours or floating
odours or moisture inflow. bacteria into other rooms.

Portion of fresh-up
operation Normal Air exhaust
HRV HRV Floor area
ventilation fan
Air exhaust Air supply

Air supply Portion of Sick room


exhaust
operation

eg. Office eg. Hospital

• Dust Prevention
Prevents dust from falling thanks to directly mounted ducts

OFF Dust Blowing mode No dust is blown out

With Competitors' Products With HRV

When conventional total heat exchange units, When the HRV is operating independently,
which are independently operated using a the fan in a interlocked indoor unit continues
dedicated remote control, are directly turning, so dust does not fall from the air filter.
connected by a duct, there is a possibility of
dust falling from the air filter of the indoor
unit when the air conditioner is OFF.

• Filter Cleaning
A signal on the remote control indicates when the air filter needs cleaning

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 10

e n e r g y e f f i c i e n c y

III. VKM Features


Heat Exchanger
Exhaust Fan Elements Damper Motor

Damper
EA
(Exhaust air to outdours)
DX coil
OA (Direct expansion coil)
(Fresh air from outdoors)

RA
(Return air from room)

Air Supply Fan


SA (Supply air to room)

Electronics Box (Control box)

Float switch
Solenoid
valve
Humidifier element:
Utilizing the principle of capillary action,
water is permeated throughout the water
humidifier element. The heated air from
the DX coil passes through the humidifier AIRFLOW SA

and absorbs the moisture

Drain pan Drain

1.
1 E NERGY E FFICIENCY

• Nighttime Free Cooling Operation


Nighttime free Cooling Operation is an energy
conserving function operating at night when the Temp.

air conditioning is switched off. By ventilating Outdoor Temp.


40
rooms containing office equipment that increases
room temperature, night purge reduces the 30 Setting Temp.
cooling load when air conditioning is switched
on in the morning. 20 Indoor Temp.
• Nighttime free cooling operation works only if auto start
ON 2 Hours
connected to Multi or VRV systems. VKM
OFF
• Nighttime free cooling operation is factory set
Air ON
to “off” but can be activated by your Daikin Conditioner OFF
start

dealer on request.

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 11
d e s i g n f l e x i b i l i t y

• Efficient Outdoor Air Introduction with Heat Exchanger and Cooling/Heating Operation
Indoor unit with outdoor air treatment
The temperature can be brought close to room temperature with minimal cooling capacity
through the use of outdoor air

100 80
60

Outdoor air
Heating and cooling temperature in summer
Effect of full heat exchange
+

Relative humidity (%)


Effect of cooling
heat recovery
40
+
humidifying Indoor temperature during cooling
Effect of
Indoor temperature during heating humidification
20
Outdoor air
temperature in winter Effect of
Effect of heating
heat ng
Effect of
Effect of full
full heat exchange
heat exchange

-5 0 5 10 15 20 25 30 35 40
Dry bulb temperature (°CDB)

2.
2 D ESIGN F LEXIBILITY

• High Static Pressure


Modifications to the fan, including the use of multiple arc blades, a thinner scroll and optimized
fan scroll angle, help to boost efficiency.
Dramatically higher static pressure is achieved due to improved fan performance. This reduces
limitations on unit location and allows more flexibility in duct design.

Higher static pressure and reduced noise

The use of multiple, overlapping arc shaped fan


blades makes it possible to optimize the chord
lenght and blade outlet angle. This results in
higher static pressure and quieter operation
over the entire operating range.

Rotating currents for reduced loss

The use of a thinner scroll allows rectification of


rotating currents within the scroll.

Higher static pressure and reduced pressure loss


Higher static pressure
In addition to increasing the scroll α
The fan diameter has been
wrap angle and boosting the static
increased and blade width
pressure, the outflow angle has been
optimized, resulting in higher
optimized to reduce pressure loss in θ
static pressure.
the outflow area.

• Indoor Unit Connectability


The indoor unit is connectable up to 130% of outdoor unit capacity

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 12

l i n e - u p

IV. Line-up
VAM-FA: ventilation

VA M 1 5 0 FA 7 V E VA M 2 5 0 FA 7 V E VA M 3 5 0 FA 7 V E

VA M 5 0 0 FA 7 V E VA M 6 5 0 FA 7 V E VA M 8 0 0 FA 7 V E

VA M 1 0 0 0 FA 7 V E VA M 1 5 0 0 FA 7 V E VA M 2 0 0 0 FA 7 V E

VKM-GM: ventilation, DX coil and humidifier

V K M 5 0 G M V 1 V K M 8 0 - 1 0 0 G M V 1

VKM-G: ventilation and DX coil

V K M 5 0 G V 1 V K M 8 0 - 1 0 0 G V 1

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

c o n t r o l s y s t e m s p. 13

V. Control Systems

HRV can also be Operation of the air conditioner using the remote control is interlocked with
connected to : HRV operation, greatly simplifying overall system control. The same remote
control centralizes air conditioning and ventilation operations, obviating any
need for HRV remote control installation work. Using a centralized remote
control also frees the user to choose from a wide range of control systems
that integrate air conditioning and ventilation. By incorporating a variety of
centralized control[iPU]
equipment, the user can build a large, high grade centralized
control system.

Outdoor unit

Indoor
unit

VKM

Remote control

BRC1D527 1 I NDIVIDUAL C ONTROL S YSTEMS


air conditioner remote control

9 Simultaneous ON/OFF of HRV and air conditioner (BRC1D527)


9 ON/OFF of HRV (BRC301B61)
9 Independent operation of HRV
9 Airflow rate switching (initial setting)
9 Ventilation mode switching (initial setting)
9 Self diagnostic functions
9 Filter sign display and reset
BRC301B61 9 Timer settings, simultaneous control with air conditioner (BRC1D527)
VAM remote control 9 Timer settings (BRC301B61)
9 Fresh-up mode switching (Selectable: supply rich mode, exhaust rich
mode; initial setting)

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 14

i n d i v i d u a l c o n t r o l s y s t e m s

9 A variety of control systems can be controlled using only the BRC1D527

• Group Control
One air conditioner remote control simultaneously controls up to 16 air conditioning and HRV
units.

Air Conditioner

Up to 16 units*1

HRV

Up to 500m
BRC1D527

*1: Count VKM unit as two air conditioners. For details, see Table 1 on page 15.

• Control using 2 remote controls


Allows control of air conditioning and HRV units from two locations by connecting two air
conditioner remote controls. (group control is possible)

Air Conditioner

HRV

BRC1D527 (No.2) Up to 500m

BRC1D527 (No.1)

• Long-distance Remote Control


Remote operation control - from a distant control room for example, is possible thanks to
wiring of up to 500 m. (2 remote control control possible)

Air Conditioner

HRV
Up to 500m

BRC1D527

2 remote control control possible

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 15

System Necessary
System construction
characteristics accessories

• Independent operation
O P E R AT I O N
INDEPEN-

HRV of HRV is possible


O P E R AT I O N S Y S T E M

DENT

• Air conditioner remote


BRC1D527
control can be used
BRC301B61
INDEPENDENT

BRC1D527/BRC301B61
O F M U LT I P L E

HRV HRV • Operation is possible


O P E R AT I O N

using 2 remote controls


S I M U LT A -
NEOUS

UNITS

• Multiple HRV units can


BRC1D527
be simultaneously con-
BRC301B61
trolled in batch. (Up to 8
HRV units can be con-
BRC1D527(No. 1)/ BRC1D527(No. 2)/ nected)
BRC301B61 BRC301B61

Indoor unit HRV


• Multiple VRV indoor units
or HRV units can be
connected and controlled
S TA N D A R D S Y S T E M

in batches, with inter-


locked operation of HRV
AIR CONDITIONING INTERLOCKED CONTROL

and air conditioners by


BRC1D527 using the air conditioner
remote control.
During group control operation, the VKM unit has a • The HRV unit can also be BRC1D527
capacity equivalent to 2 standard indoor units. Up to operated independently
16 standard indoor units can be connected at the using the remote control
same time. for the indoor unit, even
( V R V, S K Y A I R ) S Y S T E M

if the indoor unit is not in


Connectable indoor units: operation
VKM 0 1 2 3 4 5 6 7 8
Max. n° of VRV 16 14 12 10 8 6 4 2 0
Note: The VKM uses 2 remote control addresses per unit.
The number of units that can be group controlled is shown above.

• Can control interlocked


Indoor Indoor
Group 1
unit
Group 2
unit
operation of multiple
groups of VRV or Sky Air
O P E R AT I O N S Y S T E M

indoor units
M U LT I P L E G R O U P S

BRC1D527 BRC1D527 • When one of the multiple


INTERLOCKED

groups operates, HRV


units are interlocked and
operate simultaneously
Indoor Indoor
Group 1 Group 2
unit unit
BRC1D527

BRC1D527 BRC1D527

KRP2A61

HRV HRV

BRC301B61 only available for VAM-FA

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 16

c e n t r a l i s e d c o n t r o l s y s t e m s

2.
2 C ENTRALISED C ONTROL S YSTEMS

By combining the (optional) centralised control equipment listed below, the user can achieve a wide range of
comprehensive centralised control systems for air conditioning and ventilation.

DCS302C51 Centralised remote control - DCS302C51

9 64 groups (zones) of indoor units can be controlled individually by means


of the LCD remote control.
9 Max. 64 groups (128 indoor units) can be controlled
9 Max. 128 groups (128 indoor units) can be controlled via 2 centralised
remote controls, in separate locations.
9 Zone control
9 Malfunction code display
9 Max. wiring length 1,000 m (total : 2,000 m)
9 Combination with unified ON/OFF control, schedule timer and BMS system
9 Airflow volume and direction can be controlled individually for indoor units
in each group operation.
9 Ventilation volume and mode can be controlled for Heat Reclaim Ventilation
(VKM).
9 Up to 4 ‘operation/stop’ pairs can be set per day by connecting a schedule
timer.

DCS301B51 Unified ON/OFF control - DCS301B51

9 One unit can turn ON/OFF up to 16 groups (128 units) of HRV and air
conditioner units individually or in a batch.
9 Lamps display operation and failure status of the connected HRV and air
conditioner units.
9 Up to 8 units can be linked to allow centralized control of up to 128 units.

DST301B51 Schedule timer - DST301B51

9 One unit can control the operation of up to 128 HRV and air conditioner
units on a weekly schedule.
9 Can set two ON/OFF operations per day for a period of one week.

Number of units that can be connected per system


Centralised remote control 2 units
Unified on/off control 8 units
Schedule timer 1 unit

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 17

System Necessary
System construction
characteristics accessories

Unified ON/OFF control -


DCS301B51
B AT C H / I N D I V I D U A L C O N T R O L
• One control can control
the on/off operation of
16 groups of units collec-
tively or individually
HRV • Up to 8 controls can be
Indoor unit DCS301B51
DST301B51 installed in one centra-
BRC1D527 BRC1D527 lised transmission line (in
one system), which enables
control of up to 128
SYSTEM

groups. (16 groups x 8 = DCS301B51


128 groups) or
DST301B51,
Schedule timer - BRC1D527
DST301B51
AIR CONDITIONING INTERLOCKED

If necessary:
CENTRALISED CONTROL SYSTEM

Indoor unit HRV • One schedule timer can DCS302C51


control the weekly sche-
BRC1D527 dule of up to 128 units

HRV remote control can set


the individual operation of
each HRV unit

Control system can be


expanded depending on
its purposes by combining
a variety of centralised
control equipment

Centralised remote control -


DCS302C51
• The centralised remote
control provides settings
ZONE CONTROL SYSTEM

and monitoring functions


and can control up to 128
Zone 1

VRV and HRV units. A


DCS302C51 special adapter is required
Indoor unit HRV
to connect Sky Air to the
BRC1D527 BRC1D527 centralised line.
• Control is possible in 3
different patterns: indi- DCS302C51,
vidual, batch or zone BRC1D527
• Multiple groups can be If necessary:
controlled within the same DCS301B51,
zone DST301B51
Zone 2

Indoor unit HRV


• Multiple HRV units can
be operated indepen-
dently
BRC1D527
• System without air condi-
tioning or HRV remote
controls can be constructed
• Control system can be
expanded depending on
requirements by combi-
ning a variety of centra-
lised control systems

No-voltage a-contact signal


• Simultaneous operation
AIR CONDI-
TION WITH
COMBINA-

of HRVs and air condi-


TYPES OF

TIONERS

HRV
tioners is possible via
OTHER

Adapter Connection
BRC1D527 adapter
(no-voltage-
Air conditioner • Use of the HRV remote a-contact-
Connecting line control enables to change signal)
BRC1D527
can be extended settings or operate HRVs
up to 50m independently

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 18
s p e c i f i c a t i o n s

VI. Specifications

VAM-FA7 VA M 8 0 0 FA 7 V E

Ventilation

VAM-FA7VE 150 250 350 500 650 800 1000 1500 2000

Temperature exchange efficiency (%) ultra-high 74 72 75 74 74 74 75 75 75


high 74 72 75 74 74 74 75 75 75
low 79 77 80 77 77 76 76.5 78 78
Enthalpy exchange efficiency (%) for heating ultra-high 64 64 65 62 63 65 66 66 66
high 64 64 65 62 63 65 66 66 66
low 69 68 70 67 66 67 68 68 70
for cooling ultra-high 58 58 61 58 58 60 61 61 61
high 58 58 61 58 58 60 61 61 61
low 64 62 67 63 63 62 63 64 66
Power Supply VE 1 ~, 220~240V, 50Hz
Sound pressure level dB(A) Heat exchange mode ultra-high 27-28.5 28-29 32-34 33-34.5 34.5-35.5 36-37 36-37 39.5-41.5 40-42.5
high 26-27.5 26-27 31.5-33 31.5-33 33-34 34.5-36 35-36 38-39 38-41
low 20.5-21.5 21-22 23.5-26 24.5-26.5 27-28 31-32 31-32 34-36 35-37
Bypass mode ultra-high 27-28.5 28-29 32-34 33.5-34.5 34.5-35.5 36-37 36-37 40.5-41.5 40-42.5
high 26.5-27.5 27-28 31-32.5 32.5-33.5 34-35 34.5-36 35.5-36 38-39 38-41
low 20.5-21.5 21-22 24.5-26.5 25.5-27.5 27-28.5 31-33 31-32 33.5-36 35-37
Casing galvanised steel plate
Insulation Material self-extinguishable urethane foam
Dimensions HxWxD mm 269 x 760 x 509 285 x 812 x 800 348 x 988 x 852 348x988x1,140 710x1,498x852 710x1,498x1,140
Weight kg 24 33 48 61 132 158
Heat Exchange System air to air cross flow total heat (sensible heat + latent heat) exchange
Heat Exchange Element Material specially processed non-flammable paper
Air Filter multidirectional fibrous fleeces
Fan Type sirroco fan
Air Flow Rate (m3/h) ultra-high 150 250 350 500 650 800 1,000 1,500 2,000
high 150 250 350 500 650 800 1,000 1,500 2,000
low 110 155 230 350 500 670 870 1,200 1,400
External static pressure (Pa) ultra-high 69 64 98 98 93 137 157 137 137
high 39 39 70 54 39 98 98 98 78
low 20 20 25 25 25 49 78 49 59
Motor Output kW 0.030 x 2 0.090 x 2 0.140 x 2 0.230 x 2 0.230 x 4
Connection Duct Diameter mm Ø 100 Ø 150 Ø 200 Ø 250 Ø 350
Unit ambient condition -15°C ~ +50°CDB, 80% RH or less

Notes: • Air flow rate can be changed over to low mode or high mode.
• Sound pressure level is measured at 1.5m below the center of the body.
• Sound pressure level is measured in an anechoic chamber.
Sound pressure levels generally become higher than this value depending on the operating conditions, reflected sound, and peripheral noise.
• The sound pressure level at the air discharge port is about 8dB higher than the unit's sound level.
• Even when the outdoor temperature is below -15°C, the system is operable down to -20°C with the preheater installed at the outdoor air intake side.

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 19

VKM-GM
Ventilation, DX coil & humidifier
V K M 8 0 - 1 0 0 G M V 1

VKM50GMV1 VKM80GMV1 VKM100GMV1


DX coil capacity Cooling kW 4.71 7.46 9.12
Heating kW 5.58 8.79 10.69
Casing Material Galvanised steel plate
Dimensions Height mm 387 387 387
Width mm 1764 1764 1764
Depth mm 832 1214 1214
Weight kg 102 120.0 125.0
Fan Type Sirocco fan
Air flow rate Heat exchange mode Ultra-high m3/h 500 750 950
High m3/h 500 750 950
Low m3/h 440 640 820
Bypass mode Ultra-high m3/h 500 750 950
High m3/h 500 750 950
Low m3/h 440 640 820
External static pressure Ultra-high Pa 160 140 110
High Pa 120 90 70
Low Pa 100 70 60
Motor Output W 2 x 280 2 x 280 2 x 280
Temperature exchange efficiency Ultra-high % 76 78 74
High % 76 78 74
Low % 77.5 79 76.5
Enthalpy exchange Cooling Ultra-high % 64 66 62
efficiency High % 64 66 62
Low % 67 68 66
Heating Ultra-high % 67 71 65
High % 67 71 65
Low % 69 73 69
Humidifier System Natural evaporating type
Amount kg/h 2.7 4.0 5.4
Feed water pressure MPa 0.02~0.49 0.02~0.49 0.02~0.49
N° of elements 1 1 2
Operation range Around unit 0°C~40°CDB, 80% RH or less
Outdoor air -15°C~40°CDB, 80% RH or less
Return air 0°C~40°CDB, 80% RH or less
Sound level - Heat Sound pressure Ultra-high dBA 37.5 39 39.5
230V exchange High dBA 35.5 37 37.5
mode Low dBA 33 34 34.5
Bypass mode Sound pressure Ultra-high dBA 37.5 39 39.5
High dBA 35.5 37 37.5
Low dBA 33 34 34.5
Piping connection Liquid Type flare connection flare connection flare connection
Diameter mm 6.4 6.4 6.4
Gas Type flare connection flare connection flare connection
Diameter mm 12.7 12.7 12.7
Water supply mm 6.4 6.4 6.4
Drain PT3/4 external thread
Insulation material Self-extinguishable urethane foam
Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange
Heat exchange element Specially processed non-flammable paper
Air filter Multidirectional fibrous fleeces
Connection duct diameter mm Ø 200 Ø 250 Ø 250
Power supply V1 1~, 50Hz, 220-240V

Notes: • Indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDBIndoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB
• Humidifying capacity is based on: Indoor temperature: 20°CDB, 15°CWB, outdoor temperature: 7°CDB, 6°CWB
• Operation sound is measured at 1.5m below the center of the body.
• Sound values are measured in an anechoic chamber built in accordance with JIS C 1502 condition. Operating sound level generally becomes higher than this value depending on the operating conditions, reflected sound, and peripheral noise.
• The sound level at the air discharge port is about 8dB higher than the unit’s operating sound.
• For operation in a quiet room, it is required to take measures to lower the sound, for example install more than 2m soft duct near the air discharge grill.
• Air flow rate can be changed over to Low mode or High mode.
• Normal amplitude, input, efficiency depend on the other above conditions

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 20

VKM-G
Ventilation & DX coil
V K M 8 0 - 1 0 0 G V 1

VKM50GV1 VKM80GV1 VKM100GV1


DX coil capacity Cooling kW 4.71 7.46 9.12
Heating kW 5.58 8.79 10.69
Casing Material Galvanised steel plate
Dimensions Height mm 387 387 387
Width mm 1764 1764 1764
Depth mm 832 1214 1214
Weight kg 96.0 109.0 114.0
Fan Type Sirocco fan
Air flow rate Heat exchange mode Ultra-high m3/h 500 750 950
High m3/h 500 750 950
Low m3/h 440 640 820
Bypass mode Ultra-high m3/h 500 750 950
High m3/h 500 750 950
Low m3/h 440 640 820
External static pressure Ultra-high Pa 180 170 150
High Pa 150 120 100
Low Pa 110 80 70
Motor Output W 2 x 280 2 x 280 2 x 280
Temperature exchange efficiency Ultra-high % 76 78 74
High % 76 78 74
Low % 77.5 79 76.5
Enthalpy exchange Cooling Ultra-high % 64 66 62
efficiency High % 64 66 62
Low % 67 68 66
Heating Ultra-high % 67 71 65
High % 67 71 65
Low % 69 73 69
Operation range Around unit 0°C~40°CDB, 80% RH or less
Outdoor air -15°C~40°CDB, 80% RH or less
Return air 0°C~40°CDB, 80% RH or less
Sound level - Heat Sound pressure Ultra-high dBA 38.5 41 40.5
230V exchange High dBA 36.5 38 38.5
mode Low dBA 34.5 36 36
Bypass mode Sound pressure Ultra-high dBA 38.5 41 40.5
High dBA 36.5 38 38.5
Low dBA 34.5 36 36
Piping connection Liquid Type flare connection flare connection flare connection
Diameter mm 6.4 6.4 6.4
Gas Type flare connection flare connection flare connection
Diameter mm 12.7 12.7 12.7
Drain PT3/4 external thread
Insulation material Self-extinguishable urethane foam
Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange
Heat exchange element Specially processed non-flammable paper
Air filter Multidirectional fibrous fleeces
Connection duct diameter mm Ø 200 Ø 250 Ø 250
Power supply V1 1~, 50Hz, 220-240V

Notes: • Cooling: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB


• Heating: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB
• Operation sound is measured at 1.5m below the center of the body.
• Sound values are measured in an anechoic chamber built in accordance with JIS C 1502 condition. Operating sound level generally becomes higher than this value depending on the operating conditions, reflected sound, and peripheral noise.
• The sound level at the air discharge port is about 8dB higher than the unit’s operating sound.
• Air flow rate can be changed over to Low mode or High mode.
• Normal amplitude, input, efficiency depend on the other above conditions

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

o p t i o n s p. 21

VII. Options

Air suction/discharge grille (accessory)

Flexible duct
(Accessory)
High efficiency filter
RA
(Accessory)

SA

Round hood
Branch duct (Field supply)
(Field supply)
Silencer ( Accessory)
SA
Duct
(Field supply)
Thermal insulation material
(Field supply) EA
OA

VAM remote control Air conditioner Centralised remote control Unified ON/OFF control Schedule timer
remote control

Description Reference

VAM remote control BRC301B61*5


Air conditioner remote control BRC1D527
Centralised remote control DCS302C51
Unified on/off control DCS301B51
Schedule timer DST301B51
PC board adapter Wiring adapter for electrical appendices KRP2A61
For humidifier (running ON signal output) KRP50-2
For heater control kit BRP4A50
For wiring indoor unit FXZQ FXFQ FXCQ FXKQ FXMQ FXSQ FXDQ-N FXHQ FXAQ FXLQ/FXNQ
Reference KRP1B57* KRP1B59* KRP1B61* KRP1D61 KRP1B56 KRP1B3 - KRP1B61
Installation box for adapter PCB KRP1B101 KRP1D98 KRP1B96 - - KRP4A91 KRP1B101 KRP1C93 KRP4A93 -
*4/*6 *2/*3 *2/*3 *5 *4/*6 *3 *2/*3

Notes : 1. Installation box is necessary for each adapter marked with *


2. Up to 2 adapters can be fixed per installation box
3. Only 1 installation box can be installed per indoor unit
4. Up to 2 installation boxes can be installed per indoor unit
5. Necessary when operating VAM independently. When operating interlocked with other air conditioners, use the remote controls of the air conditioners

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 22

p c b o a r d a d a p t e r

1.
1 PC BOARD ADAPTER FOR HEATER CONTROL KIT - BRP4A50

When the installation of an electric heater is required in a cold region, this adapter with an
internal timer function eliminates the complicated timer connecting work necessary with
conventional heaters.

INDOOR OUTDOOR

RA EA
HRV

Heater
SA control kit OA
(field supply)
Temperature thermostat
(field supply)
BRP4A50 (ON when the temperature
is at or below -10°C)

Temperature thermostat. (field supply)


(OFF when the temperature is at or more than 5°C)
Power supply (field supply)
Relay box

Notes when installing:


• Examine fully installation location and specification for using the electric heater based on the
standards and regulations of each country.
• Supply the electric heater and safety production devices (such as a relay and a thermostat etc)
which meet the on site standards and regulations of each country
• Use a non-flammable connecting duct to the electric heater. Be sure to allow 2m or more
between the electric heater and HRV for safety.
• For the HRV units, use a different power supply from that of the electric heater and install a
circuit breaker for each of them.

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

p. 23 o p t i o n s

Silencer Air suction/discharge grille Flexible duct Duct adapter


(Noise suppression type) (Noise suppression type)

Description VAM150FA7 VAM250FA7 VAM350FA7


Additional functions Air suction discharge grille Reference K-DGL100A K-DGL250B
Colour White
Nom. piping diameter Ø 100mm Ø 150mm
High efficiency filter YAFM323F15 YAFM323F25 YAFM323F35
Replacement for air filter YAFF323F15 YAFF323F25 YAFF323F35
Flexible duct (1m) K-FDS101C K-FDS151C
Flexible duct (2m) K-FDS102B K-FDS152C

Description VAM500FA7 VAM650FA7 VAM800FA7

Additional functions Silencer Reference KDDM24A50 KDDM24A100


Nom. piping diameter Ø 200mm Ø 250mm
Air suction discharge grille Reference K-DGL200A K-DGL250A
Colour White
Nom. piping diameter Ø 200mm Ø 250mm
High efficiency filter YAFM323F50 YAFM323F65
Replacement for air filter YAFF323F50 YAFF323F65
Flexible duct (1m) K-FDS201C K-FDS251C
Flexible duct (2m) K-FDS202B K-FDS252C

Description VAM1000FA7 VAM1500FA7 VAM2000FA7


Additional functions Silencer Reference KDDM24A100 K-DDM24A100 x 2
Nom. piping diameter Ø 250mm
Air suction discharge grille Reference K-DGL250A
Colour White
Nom. piping diameter Ø 250mm
High efficiency filter YAFM323F100 YAFM323F65 YAFM323F100 x 2
Replacement for air filter YAFF323F100 YAFF323F65 YAFF323F100 x 2
Flexible duct (1m) K-FDS251C
Flexible duct (2m) K-FDS252C
Duct adapter Reference - YDFA25A1
Nom. piping diameter - Ø 250mm

Description VKM50G(M) VKM80G(M) VKM100G(M)


Additional functions Silencer Reference - K-DDM24B100
Nom. piping diameter - Ø 250mm
Air suction discharge grille Reference K-DGL200B K-DGL250B
Colour White
Nom. piping diameter Ø 200mm Ø 250mm
High efficiency filter KAF241G80M KAF241G100M
Replacement for air filter KAF242G80M KAF242G100M
Flexible duct (1m) K-FDS201C K-FDS251C
Flexible duct (2m) K-FDS202C K-FDS252C

Cyan Magenta Yellow Black


MOV91822_EPCe05-44A

Daikin Europe N.V. is approved by LRQA for its “The present catalogue is drawn up by way of information only
Quality Management System in accordance with and does not constitute an offer binding upon Daikin Europe
the ISO9001 standard. N.V.. Daikin Europe N.V. has compiled the content of this
ISO9001 pertains to quality assurance regarding catalogue to the best of its knowledge. No express or implied
design, development, manufacturing as well as to warranty is given for the completeness, accuracy, reliability or
services related to the product. fitness for particular purpose of its content and the products
and services presented therein. Specifications are subject to
change without prior notice. Daikin Europe N.V. explicitly rejects
any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of
this catalogue. All content is copyrighted by Daikin Europe N.V..”
ISO14001 assures an effective environmental
management system in order to help protect human
Printed on non-chlorinated paper / Printed in Belgium

health and the environment from the potential


impact of our activities, products and services and
to assist in maintaining and improving the quality Daikin products are distributed by:
of the environment.
EPCE05-44A / 440 / 09/05 La Movida