HRV (VAM-FA - VKM-GM - VKM-G) - EPCE05-44A - Catalogues - English
HRV (VAM-FA - VKM-GM - VKM-G) - EPCE05-44A - Catalogues - English
HRV
Heat Reclaim
Ventilation
VAM-FA Series
VKM-GM Series
VKM-G Series
c o n t e n t s p. 3
Table of Contents
I NTRODUCTION 4
VKM F EATURES 10
Energy Efficiency 10
Design Flexibility 11
L INE - UP 12
C ONTROL S YSTEMS 13
Individual Control Systems 13
Centralised Control Systems 16
S PECIFICATIONS 18
VAM-FA 18
VKM-GM 19
VKM-G 20
O PTIONS 21
Daikin
p. 4
i n t r o d u c t i o n
residential use.
Environmental Consciousness
Enhancing the present - safeguarding the future
Throughout the last 50 years or so the basic building blocks of life - air, water and the earth - have been
systematically subjected to increasing levels of pollution with little regard to their potentially devastating
effects on future generations.
Recently however, concern has grown regarding climate changes, acid rain, water and air pollution and
the constant degradation of Earth’s natural resources. The very technology that created these problems is
now being harnessed to halt and reverse them. Depletion of the ozone layer and global warming have
been highlighted and are now being addressed. Government legislation prohibiting the use of toxic
substances and the generation of pollutants has slowed down the destruction of the environment.
Daikin Europe is proud to have been pro active in this respect, closely following its Japanese parent in
implementing policies that have often pre-empted official legislative codes and directives. As a result, a
culture of “environmental management” has since 2001, played a key role in the company’s day to day
activities and development strategies.
Top management commitment is reflected in the establishment of a number of action plans, which are
now strictly observed and implemented throughout the Daikin Group.
p. 5
HRV helps create a high quality environment by interlocking with the air
conditioning system
The Daikin HRV (Heat Reclaim Ventilation) recovers heat energy lost through
ventilation and holds down room temperature changes caused by
ventilation, thereby maintaining a comfortable and clean environment. This
also reduces the load on the air conditioning system and conserves energy.
In addition, the HRV interlocks with Daikin’s VRV system, Sky Air and other air
conditioning systems and automatically switches over ventilation mode,
further increasing the effects of energy conservation. HRV operation has
been centralised on the air conditioner remote control allowing total
control over air conditioning and ventilation via a simple configuration.
The current line-up includes models with DX coil and/or humidifier - the DX
coil helps prevent the direct impact of cold airflow upon personnel during
the heating cycle and vice versa. High static pressure enhances design
flexibility.
Ventilation
Humidi-
fication
HRV
Airflow
• Humidifier
• DX coil
• High static pressure
Line-up
Air flow rate (m3/h) 150 250 350 500 650 800 1000 1500 2000
VAM-FA
Ventilation
VKM-GM:
Ventilation, DX coil
& humidifier
VKM-G:
Ventilation & DX coil
p. 6
g e n e r a l H R V f e a t u r e s
Outdoor Indoor
30.6°C
62% RH
SA
27.4°C
63% RH
SA
Temperature Integrally-
and humidity formed liner
RA RA
26°C
50% RH
32°C
70% RH
Integrally-formed liner
d e s i g n f l e x i b i l i t y p. 7
EA RA EA RA EA RA
Automatic Automatic
changeover changeover
OA SA OA SA OA SA
2.
2 D ESIGN F LEXIBILITY
• Slim Design
The slim design of the HRV unit enables it to be mounted in narrow ceiling voids and irregularly
shaped spaces.
269mm VAM250FA
• Installation under the floor of a small building • Installation under a beam • Installation in an irregular space
348mm
p. 8
d e s i g n f l e x i b i l i t y
Switch box
Access door
Maintenance cover
• Quiet Operation
Sound pressure levels are remarkable low at 20.5dBA (VAM150FA)
0 Treshold of hearing -
20 Extremely soft Rustling leaves
40 Very soft Quiet room Daikin units
60 Moderately loud Normal conversation
80 Very loud City traffic noise
100 Extremely loud Symphonic orchestra
120 Threshold of feeling Jet taking off
c l e a n a i r p. 9
3.
3 C LEAN A IR
• Fresh-Up Operation
The user can select between 2 fresh-up modes via the remote control
Portion of fresh-up
operation Normal Air exhaust
HRV HRV Floor area
ventilation fan
Air exhaust Air supply
• Dust Prevention
Prevents dust from falling thanks to directly mounted ducts
When conventional total heat exchange units, When the HRV is operating independently,
which are independently operated using a the fan in a interlocked indoor unit continues
dedicated remote control, are directly turning, so dust does not fall from the air filter.
connected by a duct, there is a possibility of
dust falling from the air filter of the indoor
unit when the air conditioner is OFF.
• Filter Cleaning
A signal on the remote control indicates when the air filter needs cleaning
p. 10
e n e r g y e f f i c i e n c y
Damper
EA
(Exhaust air to outdours)
DX coil
OA (Direct expansion coil)
(Fresh air from outdoors)
RA
(Return air from room)
Float switch
Solenoid
valve
Humidifier element:
Utilizing the principle of capillary action,
water is permeated throughout the water
humidifier element. The heated air from
the DX coil passes through the humidifier AIRFLOW SA
1.
1 E NERGY E FFICIENCY
dealer on request.
p. 11
d e s i g n f l e x i b i l i t y
• Efficient Outdoor Air Introduction with Heat Exchanger and Cooling/Heating Operation
Indoor unit with outdoor air treatment
The temperature can be brought close to room temperature with minimal cooling capacity
through the use of outdoor air
100 80
60
Outdoor air
Heating and cooling temperature in summer
Effect of full heat exchange
+
-5 0 5 10 15 20 25 30 35 40
Dry bulb temperature (°CDB)
2.
2 D ESIGN F LEXIBILITY
p. 12
l i n e - u p
IV. Line-up
VAM-FA: ventilation
VA M 1 5 0 FA 7 V E VA M 2 5 0 FA 7 V E VA M 3 5 0 FA 7 V E
VA M 5 0 0 FA 7 V E VA M 6 5 0 FA 7 V E VA M 8 0 0 FA 7 V E
VA M 1 0 0 0 FA 7 V E VA M 1 5 0 0 FA 7 V E VA M 2 0 0 0 FA 7 V E
V K M 5 0 G M V 1 V K M 8 0 - 1 0 0 G M V 1
V K M 5 0 G V 1 V K M 8 0 - 1 0 0 G V 1
c o n t r o l s y s t e m s p. 13
V. Control Systems
HRV can also be Operation of the air conditioner using the remote control is interlocked with
connected to : HRV operation, greatly simplifying overall system control. The same remote
control centralizes air conditioning and ventilation operations, obviating any
need for HRV remote control installation work. Using a centralized remote
control also frees the user to choose from a wide range of control systems
that integrate air conditioning and ventilation. By incorporating a variety of
centralized control[iPU]
equipment, the user can build a large, high grade centralized
control system.
Outdoor unit
Indoor
unit
VKM
Remote control
p. 14
i n d i v i d u a l c o n t r o l s y s t e m s
• Group Control
One air conditioner remote control simultaneously controls up to 16 air conditioning and HRV
units.
Air Conditioner
Up to 16 units*1
HRV
Up to 500m
BRC1D527
*1: Count VKM unit as two air conditioners. For details, see Table 1 on page 15.
Air Conditioner
HRV
BRC1D527 (No.1)
Air Conditioner
HRV
Up to 500m
BRC1D527
p. 15
System Necessary
System construction
characteristics accessories
• Independent operation
O P E R AT I O N
INDEPEN-
DENT
BRC1D527/BRC301B61
O F M U LT I P L E
UNITS
indoor units
M U LT I P L E G R O U P S
BRC1D527 BRC1D527
KRP2A61
HRV HRV
p. 16
c e n t r a l i s e d c o n t r o l s y s t e m s
2.
2 C ENTRALISED C ONTROL S YSTEMS
By combining the (optional) centralised control equipment listed below, the user can achieve a wide range of
comprehensive centralised control systems for air conditioning and ventilation.
9 One unit can turn ON/OFF up to 16 groups (128 units) of HRV and air
conditioner units individually or in a batch.
9 Lamps display operation and failure status of the connected HRV and air
conditioner units.
9 Up to 8 units can be linked to allow centralized control of up to 128 units.
9 One unit can control the operation of up to 128 HRV and air conditioner
units on a weekly schedule.
9 Can set two ON/OFF operations per day for a period of one week.
p. 17
System Necessary
System construction
characteristics accessories
If necessary:
CENTRALISED CONTROL SYSTEM
TIONERS
HRV
tioners is possible via
OTHER
Adapter Connection
BRC1D527 adapter
(no-voltage-
Air conditioner • Use of the HRV remote a-contact-
Connecting line control enables to change signal)
BRC1D527
can be extended settings or operate HRVs
up to 50m independently
p. 18
s p e c i f i c a t i o n s
VI. Specifications
VAM-FA7 VA M 8 0 0 FA 7 V E
Ventilation
VAM-FA7VE 150 250 350 500 650 800 1000 1500 2000
Notes: • Air flow rate can be changed over to low mode or high mode.
• Sound pressure level is measured at 1.5m below the center of the body.
• Sound pressure level is measured in an anechoic chamber.
Sound pressure levels generally become higher than this value depending on the operating conditions, reflected sound, and peripheral noise.
• The sound pressure level at the air discharge port is about 8dB higher than the unit's sound level.
• Even when the outdoor temperature is below -15°C, the system is operable down to -20°C with the preheater installed at the outdoor air intake side.
p. 19
VKM-GM
Ventilation, DX coil & humidifier
V K M 8 0 - 1 0 0 G M V 1
Notes: • Indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDBIndoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB
• Humidifying capacity is based on: Indoor temperature: 20°CDB, 15°CWB, outdoor temperature: 7°CDB, 6°CWB
• Operation sound is measured at 1.5m below the center of the body.
• Sound values are measured in an anechoic chamber built in accordance with JIS C 1502 condition. Operating sound level generally becomes higher than this value depending on the operating conditions, reflected sound, and peripheral noise.
• The sound level at the air discharge port is about 8dB higher than the unit’s operating sound.
• For operation in a quiet room, it is required to take measures to lower the sound, for example install more than 2m soft duct near the air discharge grill.
• Air flow rate can be changed over to Low mode or High mode.
• Normal amplitude, input, efficiency depend on the other above conditions
p. 20
VKM-G
Ventilation & DX coil
V K M 8 0 - 1 0 0 G V 1
o p t i o n s p. 21
VII. Options
Flexible duct
(Accessory)
High efficiency filter
RA
(Accessory)
SA
Round hood
Branch duct (Field supply)
(Field supply)
Silencer ( Accessory)
SA
Duct
(Field supply)
Thermal insulation material
(Field supply) EA
OA
VAM remote control Air conditioner Centralised remote control Unified ON/OFF control Schedule timer
remote control
Description Reference
p. 22
p c b o a r d a d a p t e r
1.
1 PC BOARD ADAPTER FOR HEATER CONTROL KIT - BRP4A50
When the installation of an electric heater is required in a cold region, this adapter with an
internal timer function eliminates the complicated timer connecting work necessary with
conventional heaters.
INDOOR OUTDOOR
RA EA
HRV
Heater
SA control kit OA
(field supply)
Temperature thermostat
(field supply)
BRP4A50 (ON when the temperature
is at or below -10°C)
p. 23 o p t i o n s
Daikin Europe N.V. is approved by LRQA for its “The present catalogue is drawn up by way of information only
Quality Management System in accordance with and does not constitute an offer binding upon Daikin Europe
the ISO9001 standard. N.V.. Daikin Europe N.V. has compiled the content of this
ISO9001 pertains to quality assurance regarding catalogue to the best of its knowledge. No express or implied
design, development, manufacturing as well as to warranty is given for the completeness, accuracy, reliability or
services related to the product. fitness for particular purpose of its content and the products
and services presented therein. Specifications are subject to
change without prior notice. Daikin Europe N.V. explicitly rejects
any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of
this catalogue. All content is copyrighted by Daikin Europe N.V..”