0% found this document useful (0 votes)
4K views

Aneng An 8009 User Manual

The document provides instructions for using a battery-powered digital multimeter, describing its various functions, ranges, and specifications. It explains the front panel buttons for changing ranges and turning on the backlight, as well as using the rotary switch to select different testing modes. Safety information is also provided to avoid electrical shock or injury when using the multimeter.

Uploaded by

nod69ass
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4K views

Aneng An 8009 User Manual

The document provides instructions for using a battery-powered digital multimeter, describing its various functions, ranges, and specifications. It explains the front panel buttons for changing ranges and turning on the backlight, as well as using the rotary switch to select different testing modes. Safety information is also provided to avoid electrical shock or injury when using the multimeter.

Uploaded by

nod69ass
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

A . Introd uct ion O.

Inst ructi on
This product is a battery-powered, true-rms, aut o-ranging digital multimeter with Function Range Resolution Accu racy MAX. Value Other (1) Front Panel ( see t he picture on t he righ t )
a 9999 cou nts LCD display and a backlight. 9.999nF O.OOlnF ±(S.0%+20) 1. LCD display
8. Safety In for m at ion 99.99nF O.O lnF 2. buttons
To avoid possible el ect rica l shock, fi re, or personal injury, p lease re ad all saf ety 9 99.9 nF O. l nF 2a. RANGE /Ba cklight: press thi s butto n to enter
information befor e you use the product. ±(2.0%+5) the manual range; each push increases the
Capacitance 9.999µF O.OOlµF 9 .999mF
(1) Do NOT exceed t he " maximum value" indica t ed in t he Specification . range; when t he highest range is reached,
(2) Examine t he connection of t he test lead s and the insulation of the product 99.99µF O.Olµ F
ne>Ct push will go back to t he lowest r ange;
before measuring voltage higher than 36V DC or 25V AC. 999.9µF O.luF to exit the manual range mode, t urn the
(3) Disconnect the t est leads from the circ uit before changing t he mode . 9 .999mF O.OOlmF ±(5.0%+5) Rotary Switch to another mode and then
(4) M isuse of mode or range can lead t o hazards, be cautious. "OL" will be shown
99.99Hz O.Ol Hz t urn it back. To turn o n the backlight, press
on th e disptay wheo the input is out of range.
(S)Safety symb ols: 999.9Hz O.lHz this b utton for more th an 2 second s; long·
9.999kHz O.OOlkHz press again t o turn off.
~ Hazardous Volta e Earth
Freq uency ±(0.1%+2) 9.999MHz 2b. SELECT/HOLD: To t oggle between different
a Double Insu lat ed Low Batte 99.99kHz O.OlkHz
testing modes {functions), press th is button.
Ri sk of Dan er . Check t he User Manual . 999.9kHz O.l kHz
To hold t he curr ent reading, press this
9.999 MH z O.OOlMHz
User Manual C. Soecifi cations
Du ty Cycle Ufi-99% 0.1% ±(0.1%+2)
button for more than 2 seconds and you
will see ~ HOLO M on the display; tong-press
Electricals ecification s
Function Ranae
999.9mV
Resol ution
O.lmV
Ac curacv MAX. Value Other
Diode
Continuity ' again t o turn off.
3. Rot ary Switch : To change mode or range .
(fro m OFF, clockw ise)
DC Voltage 9.999V 0.001V NCV
999.9V ~~ 5 6
(V) 99.99V 0.01V (-20-1000) 0
cl 1°C I 1000°(
999.9V O. l V
±(0.5%+3) Tem perat ure
(-4- 1832)°F 1°F
± 12.s%+s ) r 1832"F
3b. DC Voltage (V)/AC Voltage (V)/Frequency( high voltage wi th low frequency)/
DC Voltage 9.999mV O.OOlmV Duty Cycle
99.99mV General Snodfications 3c. DC Voltage (mV)/ACVoltage (mV)/remperatu r e
lmVl 99.99mV O.OlmV
999.9mV O.lmV Dis lav ( LCD ) 9999 Counts 3d . Resistance/ Continuity/Diode/Ca pacitance
AC Voltage 9.999V 0.00lV Ra m~.i nR Auto/ Manual 3e. Frequency (low voltage high fr equency)/DutyCycl e
750V
(V) 99.99V O.OlV Material ABS 3f. DC Current {mA&A)/ACCurrent (m A&A)
±(l.0%+3) 40Hz· l kHz
750.0V O.lV Uodate Rate 3 Times/Second 3g. DC Cu rr ent (µA)/AC Curre nt (µA)
AC Voltage 9.999mV O.OOlmV 3h. NCV
fmVI
DC Cur rent
99.99mV
999.9mA
O.OlmV
O.l mA
99.99mV Ture RMS
Back LiRht ' 4. AmA: In put term inal for cu rrent (mA&A) measurements.
5. COM : Common terminal for all measur eme nts.
±(1.0%+3) 9.999A Data Hold
l mA&Al 9.999A O.OOlA 6. VOHz : Input t ermin al for voltage, current (µA), freque ncy, duty cycle, resistance,
Low Battery Alert

~
DC Current O.Ol 11A continuity, diode, capacitance, and temperature measurements.
±(0.8%+3) 999.9µA
luAI 0.luA Au t o Power Off
AC Current 0. l mA Mechanical Saedfications (2) M easure AC/DC Voltage
lmA&AI I•••• O.OOlA
±(1.2%+3) 9.999A
40Hz· lkHz Dim ension I 130"65"32mm 1. Connect the black t est lead t o t he COM Terminal and connect t he red test lead to
AC Current 99.9911A O.OluA Weillh t f 114 the VOHz Terminal;
±(1.0%+3) 999.9µA
luAl 999.911A 0.luA 2. Turn the rotary switch to th e DC Voltage (V) Mode, or th e DC Vol t age (mV) Mode;
BattervTyoe I 1.SV AAA Batteries• 2
99.990 0.010 ± 1.0%+3 3. Press SE LECT to toggle bet ween AC/DC;
Warrantv I Onevear
999.90 O.lO 4. Touch the probes to the correct t est points of the cir cuit to m easure t he voltage;
9.999k0 O.OOlkO Envir onme nta I Soecifications
±(0.5%+3) 5. Read t he measured volt age on th e display.
Resistance 99.99k0 O.OlkO 99.99MO l Temperature I 0-40°(
Oper ating • cautio n :
999.9k0 O.lkO f Hum iditv f < 75% a. Do not measure voltage th at exceeds t he MAX Value as indicated in th e
9.999MO O.OOlMO I Temperature I ·20-60°(
±(1.5%+3) St orage Specifications;
99.99MO O.OlMO
I Humiditv l < 80% I' b. Do not to uch high voltage ci rcuit during measurements.

- 1- -2- -3- -4-


(6) M easu re Contin uity (10) Measu re Te m peratu re F. Troubleshooting
(3) Measure AC/DC Current ( mA&A) 1. Connect the black t est lead to the COM Term inal and connect the r ed test l ead 1. Con nect t he black thermocouple probe to t he COM Termina l and connec t the If your prod uct do not funct ion as no rmal, the fol lowing steps may hel p you. If t he
1. Conn ect the black test lead t o the COM Term inal and connect t he re d t est lead to t he VOHz Ter minal; red ther mocouple probe to t he VOHz Term inal; problem sti ll ca nno t be solved, please contact you r d ea ler.
to the AmA Term inal; 2. Turn t he rotary switch to the Resis t ance Mod e, press SELECT once to toggle to the 2. Turn the rotary switch to th e Tem peratu r e Mode, and t he display w ill show the
Cont inu ity Mode; room tempe rature, to t oggle bet wee n °(/°F, press SELECT button;, Problem Possible Reason
2. Tu rn the rotary switch to the DC Curr ent {mA&A) Mode;
3 . Touch the probes to the desi red tes t points;
3. Press SE LECT t o toggle bet ween AC/DC; 3. Touch the probes to the desired test po ints of the ci rcuit; Display Malfunction Low battery; replace batteries
4. Read the measured tempe ra ture on the disp lay.
4 . Brea k t he ci r cuit path t o be measured . Then co nnect the test leads across t he 4. The built-i n beeper w i ll beep when t he r esistance i s lower t han 500, which
brea k and apply po w er; indica t es a sho rt circuit.
*'Caution :
a. Do not i nput voltage at th e Temperature Mode.
BSymbol Replace batteries

5. Read t he measured current on t he d isplay. •caut ion : No current i nput Replace fuse
(11) Test NCV
""Ca ution: a. Do not input vo ltage at the Contin uity Mode.
1. Turn the rotary switch t o the NCV Mode;
a. Do not measu re current t hat exceeds t he MAX Valu e as i ndicated in t he (7) M easu re Diode 2. Hold the product and move i t around, the built-in beeper wil l beep when the inner
Specificat ions; se nso r detects AC vol t age near by. The st ronger the voltage is, t he quicker the
1. Co nnect t he blac k t est lead t o the COM Terminal and co nnect t he r ed test lead to
b. Use t heAmA Term inal and the DC Curr ent {mA&A) Mode when you are beeper beeps.
t he VO H2 Term ina l;
measur ing an u nknown cu rr ent . Then switch to the Terminal and th e Mod e if (12) Au t o Power Off
2. Turn t he rotary swit ch to the Resist anCe Mod e, press SELECT twice to toggl e t o the
necessary. 1. The product automat ica lly powers off afterlS minutes of inactivity;
Diode Mode;
3. Co nnect the r ed pro be to the anode side and t he black probe to the cathode side 2. The bui lt-i n beeper beeps S times 1 minute before powe r off;
(4 ) M easure AC/DC Cu rren t (µA)
3. To restart t he product, press SELECT button; .
1. Conn ect the black t est lead t o the COM t erm inal and connect t he red t est lead of the d iode be ing test ed;
4. To disable the Auto Power Off functio n, hold down the SELECT but ton w hen
4. Read t he forward bias vol t age valu e on the display; turning o n t he p roduct, you will hea r five beeps if you have successful ly
to t he VOHz Ter minal; LIMITED WARRANTY
S. If the p olarity of t he tes t leads is reversed wi t h d iode polarity or the d iode is disabled the func t ion.
2. Turn the rotary switch to t he DC Current (µA) Mode; AND LIMITATION OF LIABILITY
broken, the disp lay reading shows "O L".
3. Press SELECT t o toggle between AC/DC;
•caut ion : E. Ge near I Maint enance
4. Brea k the ci rcuit path t o be measured. Then connec t the test leads across the
a. Do not in put voltage at the Diode Mode . Beyond replaci ng batteries and fuses, do not at tempt to r epair or service the product Customers enjoy one-year warranty from the date of purchase. This warranty
break and apply power; unless you are q ual ified to do so and have the relevant calibrat ion, perfor mance t est,
b. Discon nect ci rcuit power and discharge all capacitors before you test diode . does not cov er f uses, d isposable batteries, o r damage from accide nt, neglect,
5. Read t he measured curr ent on the display. and service instructions.
misuse, alter nation, contamination, or abno rmal conditions of operation or
* Caution: {8) Measure Capac itance (1) Do not operat e the product around hot, wet , flammable, explosive or magnet ic
environments. handling.
a. Do not measu re current that exceeds the MAX Value as i ndicated in the 1. Connect the blac k t est lead to the COM Termina l and connect t he red test lead to
(2) Clea n the product with damp dot h and mi ld deterge nt; do not use abrasives or
Specificatio ns; t he VOH2 Terminal;
solvents.
b. Use the AmA Term inal and t he DC Cu rr ent (mA&A) Mode w hen you are 2. Turn t he rota ry switch to the Resistance M ode, press SELECT three times to toggle (3) Remove the input signals before you clean t he product All rights r eserved. Specifications are subj ect to change w ithout not ice.
measu ring an un known cu rrent . Th en switch to the Ter mi nal and the Mode if t o the Ca pacita nce Mode; (4) Remove the bat teries if you will not use the prod uct for a long time to prevent
necessary. 3. Connect t he r ed probe to the anode side and the black probe to the cat hode possi ble battery!eak.
sid e of the capacitor being tested; (5) When "B" is shown on t he display, batteries shal l be replaced as below:
4. Read t he measured capacitance value on the d isplay once the reading is stablized .
1. Loosen the screw and remove the battery cover;
Do not input voltage e>cceeds 36V DC or ZSV AC when you are at the setting of 2. Replace the used batteries wi th new batter ies of the sa me type;
measuring current. "Caution: 3. Place the battery cover hack and fast en the screw .
a. Disconnect circu it power and d ischarge all ca pacitors before you test capac itance. (6) Replace fuses as above steps. Use only fuses of the same type as the original
(9) Measure Freque ncy an d Dut y Cycle
(S) Measu re Resis t ance
1. Co nnect the black test lead to t he COM Term ina l and connect t he red t est lead to Warning:
1. Connect the black test lea d t o the COM Termina l and con nect the red t est lead to
t he VOHz Ter mi nal; 1. Do NOT e1Cceed the " maKimum value" indicated in the Specification;
t heVOHz Term inal; 2. To measu re high voltage low frequency, tu rn the r ot ary switch to the DC Voltage(V) 2. Do NOT input voltage at the Current Mode, the Resi stance Mode, the Diode
2. Tu rn t he rot ary switch to t he Resist ance Mode, and the display wil l show uOL"; Mode; press SELECT twice to toggle to the Frequency Mode or press SE LECT three Mode, the Continuity Mode, or the Temperature Mode;
3. Touch the probes t o the desired test points of t he circuit t o measure the resistance; t imes t o togg le to the Duty Cycle Mode. To m easure low voltage high freque ncy, 3. Do NOT use the product when the batteries or the battery cover is not placed
4. Read the measured resistance on the display. t urn the ro t ary switch to the Frequency Mode; p ress SE LECT once t o toggle to the properly;
• caution: Duty Cycle Mode; 4. Turn off the product and remove the test leads from the test points before
a. Disconnect circui t powe r and discharge all capaci t ors before you test resist ance. 3. Touch the probes to the desired test points of the circu it; changing batteries or fu ses.
b. Do not input voltage at the Resistance Mode. 4. Read the measu red frequency/duty cycle val ue on the d isplay.