Desktop Spectrophotometer DSCD Series: Leader in Lighting & Electrical Test Instruments
Desktop Spectrophotometer DSCD Series: Leader in Lighting & Electrical Test Instruments
(DSCD Series)
Brochure
DSCD-900
-Page 1 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
D\8 Structure
Our device adopts internationally observe condition D/8 (Diffused lighting, 8
degrees observe angle) and SCI (specular reflection included)/SCE (specular
reflection excluded).
-Page 2 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Technical Data
Type DSCD-900
Wavelength range
400-700nm
Wavelength interval
10nm
Reflectivity range
0-200%
-Page 3 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Type DSCD-900
Resolution
0.01%
Observer angle
2°/10°
ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1)
Color difference formulas ,ΔE*94,ΔE*00,ΔEab(Hunter),555color
classification
Repeatability
color values: ΔE*ab<=0.015(After calibration,
standard deviation of 30 measurements on test
white board, 5 second intervals),Maximum: 0.03
Interface
USB
-Page 4 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Type DSCD-900
Size
350*300*200mm(L*W*H)
Weight 4.5kg
Application
-Page 5 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
DSCD-901
Brief Introduction
Side color measurement
Its test caliber is in the sideward, it will be more convenient to fix the sample. Solid
samples (steel, cloth) can be placed directly on the measurement port. Paste
objects can be placed in a cuvetee, and then placed in the measurement port. It is
very suitable for powder material testing in case of material falling into the
integrating sphere to affect the testing accuracy.
D\8 Structure
Our device adopts internationally agreed observe condition D/8 (Diffused lighting, 8
degrees observe angle) and SCI (specular reflection included)/SCE (specular
-Page 6 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
reflection excluded).
-Page 7 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Technical Data
Type DSCD-901
Wavelength range
400-700nm
Wavelength interval
10nm
Reflectivity range
0-200%
Reflectivity resolution
0.01%
Observation angle
2°/10°
-Page 8 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Type DSCD-901
F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF
SPD distribution/data, sample's color values,
color difference values/graph, pass/fail results,
color error tendency, color simulation, display
Data being displayed
measurement area, history data color
simulation, manual input standard sample,
generate measurement report
ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1
Color difference formulas ),ΔE*94,ΔE*00,ΔEab(Hunter),555color
classification
Repeatability
color values:ΔE*ab<=0.015 ( After calibration,
standard deviation of 30 measurements on test
white board, 5 second intervals),Maximum: 0.03
Interface
USB
-Page 9 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Type DSCD-901
Size
350*300*200mm(L*W*H)
Weight 4.5kg
Application
-Page 10 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
DSCD-910
Brief Introduction
D\0 Structure
-Page 11 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Gardner Color Code: Mix the cobalt chloride solution, ferric trichloride solution,
potassium chloroplatinate solution in different proportion, we will get the standard
color Chroma. Normally, the data is between 1-18. It is suitable for the liquid whose
color is darker than Pt-Co color.
American Public Health Association (APHA): use K2PtCl6 mix with hydrochloric acid
to make the standard color chroma and normally the data is between 1-500 which
is same as Hazen.
-Page 12 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Technical Data
Type DSCD-910
d/0(Diffused illumination, 0 ° viewing)SCS
optical engine(light splitting and integration
Illumination system),( conform to CIE No.15, ISO 7724/1,
ASTM E1164,DIN 5033 Teil7, JIS Z8722
Condition c standards)
Size of integrating sphere Φ40mm,Alvan diffused reflection surface coating
CLEDs(entire wavelength balanced LED light
Illumination Light source
source)
Sensor dual light path sensor array
-Page 13 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Type DSCD-910
Wavelength range 400-700nm
Wavelength interval 10nm
Half spectral width 5nm
Reflectivity range 0-200%
Reflectivity resolution 0.01%
Observation angle 2°/10°
A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,
Measurement light source F9,F10,F11,F12
CWF,U30,DLF,NBF,TL83,TL84
Transmittance graph/value, chromatic value,
color difference values, color assessment results,
Data being displayed color tendency, history color value simulation,
manual input standard sample, generate
measurement reports
Measurement time interval 2 seconds
Measurement time 0.5 seconds
CIE-L*a*b, L*C*h, CIE-L*u*v, XYZ, Yxy,
Color space
Transmittance, Hunterlab, Munsell MI, CMYK
ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1
Color difference formulas ),ΔE*94,ΔE*00ΔEab(Hunter),555color
classification
-Page 14 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Type DSCD-910
25℃ to 55℃,relative humidity 80% or below(at
Storage temperature range
35°C ), no condensation
AC power line, color management software, drive
Standard accessories software, USB cable, black calibration tube,
40*10mm cuvette
Application
DSCD-920
-Page 15 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Brief Introduction
Transmission D/0 Structure and Reflection D/8 Structure
-Page 16 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Technical Data
Type DSCD-920
Reflection: d/8(Diffused lighting, 8 degrees
receiving)Compatible with SCI/SCE Measurement
Measurement Condition ISO7724/1、DIN5033 Teil7、JIS Z8722 condition C、
CIE No.15、ASTM E1164)Transmission d/0(Diffused
lighting, Vertical direction receiving)
Size of integrating
Φ15.2cm, Alvan diffused reflection surface coating
sphere
CLEDs(entire wavelength balanced LED light
Illumination Light source
source)
-Page 17 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Type DSCD-920
Sensor dual light path sensor array
Wavelength range 400-700nm
Wavelength interval 10nm
Half spectral width 5nm
Reflectivity range 0-200%
Reflectivity resolution 0.01%
Observation angle 2°/10°
Measurement light A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9
source ,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84
SPD distribution/data, sample's color values, color
difference values/graph, pass/fail results, color
Data being displayed error tendency, history data color simulation,
manual input standard sample, generate
measurement report
Measurement time
2 seconds
interval
Large Aperture (LAV):2.54cm (=1inch)
Medium Aperture (MAV):1.5cm(=0.6inch)
Small Aperture (SAV):0.75cmx1.0cm(0.3inch x
Reflection Aperture
0.4inch)
Very Small Aperture(VSAV):0.3cmx0.8cm(0.12inch
x 0.31inch)
CIE-L*a*b, L*C*h, CIE-L*u*v, XYZ, Yxy,
Color space Transmittance, Hunterlab , Munsell MI,CMYK, RGB,
HSB
ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),Δ
Color difference formulas
E*94,ΔE*00,ΔEab(Hunter),555color classification
WI(ASTM E313-10,ASTM E313-73,CIE/ISO,AATCC,
Hunter, Taube Berger, Ganz, Stensby), YI(ASTM
Other colorimetric D1925,ASTM E313-00,ASTM E313-73), Tint
indices (ASTME313-00,CIE,Ganz), Metamerism index
Milm, Stick color fastness, Color fastness, APHA,
Pt-Co, Gardner
light splitting reflectivity: standard deviation within
0.08%
Repeatability color values:ΔE*ab<=0.015(After calibration,
standard deviation of 30 measurements on test
white board, 5 second intervals, Maximum:0.03)
Interface USB
Data storage mass storage
Light source longevity 5 years, 1.5 million tests
Size 583*330*304mm(L*W*H)
-Page 18 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Type DSCD-920
Work temperature range 15℃-32℃ (60°F-90°F)
0℃ to 45℃,relative humidity 80% or below(at
Relative Humidity
35°C ), no condensation
AC power line, color management software, drive
Standard accessories software, USB cable, black/white calibration tube,
40*10cuvette, cuvette support, testing report
-Page 19 -