Zelio Timer Relays - RE17RAMU
Zelio Timer Relays - RE17RAMU
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product Zelio Time
Product or component type Modular timing relay
Discrete output type Relay
Width 17.5 mm
Device short name RE17R
Time delay type A
At
Time delay range 0.1...1 s
1...10 h
1...10 min
1...10 s
10...100 h
6...60 min
6...60 s
Nominal output current 8A
Complementary
Contacts type and composition 1 C/O
Contacts material Cadmium free
Control type Selector switch on front panel
[Us] rated supply voltage 24...240 V AC at 50/60 Hz
24 V DC
Voltage range 0.85...1.1 Us
Supply frequency 50...60 Hz (+/- 5 %)
Release of input voltage 10 V
Connections - terminals Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12 (solid) without cable
end
Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14 (solid) without cable
end
Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14 (flexible) with cable end
Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16 (flexible) with cable end
Environment
Immunity to microbreaks <= 20 ms
Standards 2004/108/EC
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
IEC 61812-1
2006/95/EC
Product certifications CSA
cULus
GL
Ambient air temperature for storage -30...60 °C
Ambient air temperature for operation -20...60 °C
IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Vibration resistance 20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Relative humidity 93 % without condensation conforming to IEC 60068-2-30
Electromagnetic compatibility Electrostatic discharge immunity test, in contact at 6 kV conforming to IEC 61000-4-2 level 3
Electrostatic discharge immunity test, in air at 8 kV conforming to IEC 61000-4-2 level 3
2
Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3
level 3
Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kV conforming to IEC
61000-4-4 level 3
Electrical fast transient/burst immunity test, direct at 2 kV conforming to IEC 61000-4-4 level 3
1.2/50 µs shock waves immunity test, differential mode at 1 kV conforming to IEC 61000-4-5 level 3
1.2/50 µs shock waves immunity test, common mode at 2 kV conforming to IEC 61000-4-5 level 3
Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3
Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11
Conducted and radiated emissions conforming to EN 55022 class B
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1650 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
End of Life Information
Product end of life instructions Available
3
Product data sheet RE17RAMU
Dimensions Drawings
Width 17.5 mm
4
Product data sheet RE17RAMU
Connections and Schema
5
Product data sheet RE17RAMU
Connections and Schema
Wiring Diagram
6
Product data sheet RE17RAMU
Technical Description
Description
The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous.
Function: 1 Output
Function: 2 Outputs
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
7
Product data sheet RE17RAMU
Technical Description
Description
After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact closes. When the
cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.
Function: 1 Output
T = t1 + t2 +...
8
Product data sheet RE17RAMU
Technical Description
Legend
Relay de-energised
Relay energised
Output open
Output closed
C Control contact
G Gate
R Relay or solid state output
R1/R2 2 timed outputs
R2 inst. The second output is instantaneous if the right position is selected
T Timing period
Ta - Adjustable On-delay
Tr - Adjustable Off-delay
U Supply