This document is a checklist for specifying valves. It requests information about 1) the type, size, quantity of valves needed, 2) requirements for actuators, 3) specifications for strainers, 4) requirements for control valves, 5) optional extras, and 6) supplementary information such as expected heat input, installation location, and special requirements. The completed checklist should be sent to [email protected].
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
234 views

Checklist For Valve Spec PDF

This document is a checklist for specifying valves. It requests information about 1) the type, size, quantity of valves needed, 2) requirements for actuators, 3) specifications for strainers, 4) requirements for control valves, 5) optional extras, and 6) supplementary information such as expected heat input, installation location, and special requirements. The completed checklist should be sent to [email protected].
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Checklist for valve specification VALVES FOR E X TREMES

Please use the checklist to outline the specification Your RFQ:


you require. Send checklist to: [email protected]

1. Valve type, sizes and quantity 3. For strainers

Quantity*: Required wire mesh size:


pieces 40 μm other

Kind of actuation*: Max. pressure drop:


manual pneumatic electric solenoid Δp

Valve type*:
series
4. For control valves
Globe valve (on-off):
manual pneumatic
Required flow rate:
Download checklist as PDF-file: www.stoehr-valves.com/support

Kv- /Cv-Wert
Control valve:
yes
Required control characteristic:
equal percentage
Check valve:
yes

Overflow check valve: 5. Further options


yes

Strainer: Welding flange for vacuum-jacketing*:


yes yes

Body type*: Surface treatment:


straight-through (180°) angle (90°) polished electro polished

Nominal diameter*: Purge connections:


DN yes

Nominal pressure: Purge valve:


PN minimal PN normal PN maximum yes

Cracking pressure for check valve: Thermal coupling:


bar copper flange sliding thermal contact

Type of medium or combination of medias*: Customer specific acceptance tests:


e.g. He please specify

Medium temperature*:
temp. °C K
6. Supplementary information
Required connections:
type measurement
standard
Expected heat input:
Watt

Temperature installation area:


2. Actuator Location of installation:


indoor outdoor
* = mandantory | blue = standard

In case of pneumatic actuator, Special requirements:


desert, salty water etc.
how much service pressure is given?
6 bar
Installation position:
In case of electrical power, normal optional

which voltage and type is required? Others:


Volt type of voltage
closing time opening time min. hubs

Fail safe position*:


none NO NC

ATEX: 7. Sender
yes

Mounting parts*: Company, Institute:


pilot valve limit switches IP regulator

air pressure reducer air filter Contact name:

Phone:

Signature:

STÖHR ARMATUREN GmbH & Co KG fon: +49 8231 34 90 – 0


Dornierstraße 4 fax: +49 8231 34 90 – 45 email print
86343 Königsbrunn, Germany [email protected]