Mx-5400

Four Loop
Analogue Addressable
Fire Alarm Control Panel

Advanced Fire Panel Technology

The Mx-5400 series is fully expandable from 1 to


4 loops and supplied with 4 on-board sounder
circuits, 20 programmable Zonal LED’s with
slide-in labels, and 25 System LED’s for
information purposes. There are also 4
programmable function buttons with LED
indication for confirmation of operation.

The control panel consists of the latest dual flash-


based microprocessor technology combined with
a high resolution / high contrast Graphical LCD
display and tactile keypad providing a simple
'Select & Click' programming aid for Engineer
configuration and End-User operation.

Powerful Cause and Effect programming coupled


with 'DynamiX' zoning, and enhanced ‘Trace
Diagnostics’ makes the panel suitable for a wide
range of site applications from small to large TM

complex multi-area systems. Fully programmable


G-210022 BS EN 54-2 & 4 0786-CPD
on-site via the on-board alphanumeric keypad, or
PC-NeT Configuration Software. Features
PC Software +Fully expandable from 1 - 4 loops via plug-in loop driver boards.
An extensive suite of user-friendly Windows +20 programmable Zonal / 25 System LED’s with slide-in labels.
based PC software programs have been +Dedicated loop driver for Apollo and Hochiki protocol support.
developed to enhance your experience when +Advanced graphical LCD user interface and support for up to 200
using Mx-5000 Series of Fire panels. The suite fire zones by default allowing full EN54 compliance without
incorporates a number of different programmes additional hardware expansion.
to include a Configuration, Service, Logo and
+Dual flash-based microprocessor technology with Real-Time Clock
Virtual Panel Tool to allow the flexibility of the
on-board.
equipment to be fully explored.
+Dedicated USB & RS232 Serial Port for direct PC or modem
Network connection.
+Installer friendly 'Auto-learn', 'Loop Detection' and on-board Scope
Simply adding a network card allows the panel to
facility for ease of Commissioning and Fault finding.
communicate with any other Mx-5000/Mx-4000
fire panel, Remote Terminal, or Network
+Fully programmable via the on-board alphanumeric keypad, or PC
Peripheral, such as, ‘ipGateway™’ or configuration tools.
BMS/Graphical Interface. The network operates +The Graphical display can be configured to operate with virtually
as a true peer-to-peer system and can be any language or character set, and allow the installer's logo to be
configured in a Fault-Tolerant Loop or Radial applied using the ‘Logo’ application software.
format. +Robust removable equipment chassis with plug-in connectors for
simple fixing and cable termination.
+Rack-mount options available.
+Integral ‘P-Bus’ for system expansion via available option cards.
+Connection to the ‘Ad-NeT’ peer-to-peer network is achieved using
a simple plug-in network card allowing the system to share up to
2000 zones with full cross panel reporting, control and site-wide
cause and effect functionality.
+Approved to BS EN54 part 2, 4 and 13.
33
??

Key Features
Dedicated 1 - 4 Loop Control Panel Programmable Push Buttons
EN54 Parts 2, 4, & 13 ‘Approved’ Multiple Languages
Global Compliance Fully Networkable
3 Year Warranty as standard 20 Zonal / 25 System LED’s with slide-in labels

Specification
Base Technology Dual flash-based Processors with Real-Time Clock, ‘Trace’ Diagnostics, Programmable
Languages and Character Sets
Display White Backlit 240 x 64 Graphical LCD
LED Indicators 4 Red (3 x Fire, 1 x More Alarms), 1 Green (Power) & 25 Amber (Fault & System)
Controls Alpha Numeric Keypad permitting Navigation, Reset, Mute, Silence, Resound, Evacuate,
and 4 x Programmable Push Buttons
Protocols Apollo (Xp95 / Discovery) & Hochiki ‘ESP’
Number of Fire Zones 2000 ‘Dynamix’ (200 per individual panel)
Number of Loops Dedicated 1- 4 Loop Control Panel
Devices per loop Protocol Dependent
Loop Current 500mA per loop
On-Board Sounder Circuits 4 x 1 Amp Programmable

Mx-5000
On-Board Relays 2 x 1 Amp 30v AC/DC Programmable (10mA, 5v min) - Expandable using Mxp-507
Auxiliary Supply 1 x 24v 500mA
Programmable Input 1 x Monitored Programmable Input On-board
Programmable Key Switch Inputs 8 Volt Free Digital Inputs
Total Available Output Current 5A Maximum Available for Loop Current + Sounder Outputs + Auxiliary Supply
Mains Supply 200 - 240v 47-63 Hz AC (+10%, -15% tolerance) 1.4A Max
Battery Capacity 24V 4Ah Internal (min), 24v, 18Ah Internal (max), Deep Enc. (D) - 24v, 45Ah Internal
(max)
Charger Current 2A Temperature Compensated
Serial ports 1 x On-Board RS232 connection for PC, Modem, IP, or Portable Printer
USB Interface 1 x USB B type connection for PC Communication
Programming On-board Keypad or PC running Windows Tools
Event Log 5000 Event & Diagnostic + 500 Fire
Networking Optional plug in Network Card (Mxp-503 - Standard, or Mxp-509 - Fault-Tolerant)
Printer (Optional) On-board (M, L, D Enc. Only)
Enclosure / Colour Steel IP30 / RAL7035
Cable Entry (20mm knockouts) 19 x Top, 11 x Rear, & 2 x Bottom, Deep Enc. (D) - 30 x Top, 11 x Rear, & 3 x Bottom
Size H x W x D mm 470 x 450 x 115, Deep Enc. (D) - 470 x 450 x 190
Metalwork Options Flushing Bezel, Battery Box and Rack Mount
Approvals EN 54-2:1998, EN 54-4:1998 & EN 54-13:2005

Order Codes
Enclosure/Loop Driver Selection:
Mx-540x: Multi Loop Panel in Standard Enclosure
Mx-540xD: Multi Loop Panel in Large Deep Enclosure
x - Please insert loop driver quantity 1 - 4
Advanced Electronics Ltd, Moorland Way, Nelson Park, Cramlington, England, UK, NE23 1WE
Tel: +44 (0) 1670 707111 Fax +44 (0) 1670 707222
Web Export: www.advelexport.com
Web UK: www.advel.co.uk

Document No: 681-107 Rev: 01