1.2 PURPOSE
This document gives instructions on installing the PathPilot® v2.0
Upgrade.
Page 2
©Tormach® 2018 tormach.com
Specifications subject to change without notice. TD10530: Upgrading to PathPilot v2.x (0718A)
TECHNICAL DOCUMENT
Complete the upgrade procedure in the following order: 7. Transfer the PathPilot® update file to a USB drive.
1. "Update to PathPilot® v1.9.x" (below) 8. On the PathPilot® controller, insert the USB drive.
2. "Create Backup Files" (below) 9. Make sure the PathPilot® controller is powered on.
3. "Install PathPilot® v2.x" (on the next page) 10. Push in the red Emergency Stop button.
11. From the PathPilot® interface, on the Status tab, click
2.1.1 Update to PathPilot® v1.9.x
Update.
Before upgrading to PathPilot® v2.x, you must make sure the
PathPilot® controller is updated to the latest version of PathPilot®
v1.9.x. The latest version of PathPilot® v1.9.x has settings that
improve the backup process, so you must update to this version
before backing up your files.
To update to PathPilot® v1.9.x:
1. From the PathPilot® interface, locate the machine
configuration and software version, as shown in the
following example.
12. Select the PathPilot® update file on the USB drive, and then
click Update.
13. Follow the instructions on the screen to restart the
PathPilot® controller.
14. When restarted, the PathPilot® v1.9.x interface displays.
15. Go to "Create Backup Files" (below).
4. From tormach.com/pp-updates, identify the latest version of 2. From the PathPilot® interface, on the Main tab, in the MDI
PathPilot® v1.9.x available. Line DRO field, type ADMIN SETTINGS BACKUP.
Page 3
©Tormach® 2018 tormach.com
Specifications subject to change without notice. TD10530: Upgrading to PathPilot v2.x (0718A)
TECHNICAL DOCUMENT
Page 4
©Tormach® 2018 tormach.com
Specifications subject to change without notice. TD10530: Upgrading to PathPilot v2.x (0718A)
TECHNICAL DOCUMENT
5. When the PathPilot® controller powers on, repeatedly press 7. From the Startup Options screen, select R-Drive Image GUI
F10, F11, and F12 on the keyboard in rapid succession until (Graphic Mode).
the BIOS boot menu displays. NOTE: On the Startup Options screen, R-Drive
NOTE: Do not press F10, F11, and F12 at the same Image GUI (Graphic Mode) is automatically
time. Depending on when you purchased the selected if no action is taken in five seconds.
PathPilot® controller, the exact key required to 8. Press ENTER on the keyboard.
access the BIOS boot menu varies. The R-Drive Image License Agreement dialog box displays.
A BIOS boot menu displays, similar to the following image. NOTE: If the R-Drive Image License Agreement
dialog box displays and you did not press ENTER on
the keyboard, this indicates that R-Drive Image
GUI (Graphic Mode) was automatically selected
from the Startup Options screen.
9. From the R-Drive Image License Agreement dialog box, click
Yes.
Page 5
©Tormach® 2018 tormach.com
Specifications subject to change without notice. TD10530: Upgrading to PathPilot v2.x (0718A)
TECHNICAL DOCUMENT
Page 6
©Tormach® 2018 tormach.com
Specifications subject to change without notice. TD10530: Upgrading to PathPilot v2.x (0718A)
TECHNICAL DOCUMENT
Page 7
©Tormach® 2018 tormach.com
Specifications subject to change without notice. TD10530: Upgrading to PathPilot v2.x (0718A)
TECHNICAL DOCUMENT
8. If desired, you can enable an Internet connection in the 2. From the Network Configuration dialog box, in the Networks
PathPilot® controller, which allows you to use Dropbox with list, select the network you want to use, and then click
PathPilot®, and receive automatic PathPilot® updates. Go to Connect.
the next section, "Enabling Internet Connection (Optional)" NOTE: Wi-Fi connection signal strengths are
(below). indicated on a scale of 0 to 100, with 100 being the
If you do not want to use these features, you have strongest.PathPilot® continually refreshes the
completed installing and configuring PathPilot® v2.x. signal levels to help you find the best placement
for your Wi-Fi network adapter. Ethernet
3.1.3 Enabling Internet Connection (Optional)
connections are indicated by a prefix in the format
If desired, you can enable an Internet connection on your
eth[NUMBER]. For example, eth1.
PathPilot® controller to receive automatic PathPilot® updates, and
The PathPilot® operating system connects to the Internet
save time while completing common tasks, like transferring files
using the network you specified. It continues to detect and
with Dropbox instead of a USB drive.
connect to the Wi-Fi network, even after power cycles.
To enable an Internet connection:
3. Once connected, you can use the Dropbox and automatic
1. From the PathPilot® interface, on the Status tab, click the
updates features. Depending on what you want, see the
Internet button.
following procedures:
l "Connect to Dropbox (Optional)" (below)
l "Enable Automatic Updates (Optional)" (page 10)
To connect to Dropbox:
1. From the PathPilot® interface, on the Main tab, in the
Figure 3-5: Network Configuration dialog box. MDI Line DRO field, type ADMIN DROPBOX.
Page 8
©Tormach® 2018 tormach.com
Specifications subject to change without notice. TD10530: Upgrading to PathPilot v2.x (0718A)
TECHNICAL DOCUMENT
2. Press ENTER on the keyboard. 6. Because Dropbox stops synchronizing once the PathPilot®
The Dropbox Configuration application displays. controller’s internal drive has less than 500 MB of free
space, we recommend that you exclude large or unrelated
folders from synchronization. Click Exclude Folder....
3. Click Install.
Figure 3-8: Exclude Folder button.
The Dropbox Installation dialog box displays.
The Add Folder to Excluded Set dialog box displays.
4. Click OK.
7. From the Add Folder to Excluded Set dialog box, type the
name of the folder to exclude.
Page 9
©Tormach® 2018 tormach.com
Specifications subject to change without notice. TD10530: Upgrading to PathPilot v2.x (0718A)