0% found this document useful (0 votes)
106 views

Omron Single Phase Current Relay

The document describes a new single-phase current relay product. It provides details on the specifications, features, models, ordering information and accessories of the current relay. Key features include monitoring overcurrents or undercurrents, manual or automatic reset, and isolated power supply inputs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views

Omron Single Phase Current Relay

The document describes a new single-phase current relay product. It provides details on the specifications, features, models, ordering information and accessories of the current relay. Key features include monitoring overcurrents or undercurrents, manual or automatic reset, and isolated power supply inputs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

New Product

Single-phase Current Relay


K8AK-AS
Ideal for Current Monitoring for
Industrial Facilities and Equipment.
• Monitor for overcurrents or undercurrents.
• Use commercially available CTs (CT current on secondary
side: 0 to 1 A or 0 to 5 A).
• Manual resetting and automatically resetting supported by one
Relay.
• Startup lock and operating time can be set separately.
• One SPDT output relay, 5 A at 250 VAC (resistive load).
• Output relay can be switched between normally open and
normally closed.
• Output status can be monitored using LED indicator.
• Inputs are isolated from the power supply.
Refer to Safety Precautions on page 9.
Refer to page 8 for commonly asked questions.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.

Ordering Information
List of Models
Setting range Power supply voltage Model
2 to 20 mA AC/DC, 24 VAC/DC K8AK-AS1 24 VAC/DC
10 to 100 mA AC/DC,
50 to 500 mA AC/DC 100 to 240 VAC K8AK-AS1 100-240 VAC
0.1 to 1 A AC/DC, 24 VAC/DC K8AK-AS2 24 VAC/DC
0.5 to 5 A AC/DC,
0.8 to 8 A AC/DC 100 to 240 VAC K8AK-AS2 100-240 VAC

10 to 100 A AC*, 24 VAC/DC K8AK-AS3 24 VAC/DC


20 to 200 A AC* 100 to 240 VAC K8AK-AS3 100-240 VAC
*1 The K8AK-AS3 is designed to be used in combination with an OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.)

Accessory (Order Separately)


●OMRON CT ●Commercially Available CTs*
Applicable CT current on secondary
Appearance Input range Model Appearance Applicable Relay
Relay side

10 to 100 A AC, 0 to 1 A AC,


K8AK-AS3 K8AC-CT200L K8AK-AS2
20 to 200 A AC 0 to 5 A AC

* If you use a commercially available CT, do not exceed the overload


capacity of the K8AK-AS2.

1
K8AK-AS
Ratings and Specifications
Input Range
Connection Input
Model Range*1 Setting range Input type Overload capacity
terminal impedance
0 to 20 mA AC/DC I1-COM 2 to 20 mA AC/DC, Approx. 5 Ω Direct input
K8AK-AS1 0 to 100 mA AC/DC I2-COM 10 to 100 mA AC/DC, Approx. 1 Ω Direct input
0 to 500 mA AC/DC I3-COM 50 to 500 mA AC/DC Approx. 0.2 Ω Direct input Continuous input at
120% of maximum input
0 to 1 A AC/DC I1-COM Approx. 0.12 Ω Direct input or
0.1 to 1 A AC/DC, commercially 1 s at 150%
K8AK-AS2 0 to 5 A AC/DC I2-COM 0.5 to 5 A AC/DC, Approx. 0.02 Ω available CT
0.8 to 8 A AC/DC
0 to 8 A AC/DC I3-COM Approx. 0.02 Ω Direct input
0 to 100 A AC I2-COM --- OMRON CT Continuous input at 120% with
*2 an OMRON CT (K8AC-CT200L).
10 to 100 A AC ,
K8AK-AS3 30 s at 200%
0 to 200 A AC I3-COM 20 to 200 A AC*2 --- OMRON CT 1 s at 600%
* CT capacity on primary side.
*1 The range is selected using connected terminals.
*2 The K8AK-AS3 is designed to be used in combination with an OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.)

Ratings
24 VAC/DC
Power supply voltage Isolated power supply 100 to 240 VAC
24 VAC/DC: 2.0 VA/1.1 W max.
Power consumption 100 to 240 VAC: 4.6 VA max.
10% to 100% of the maximum value of the setting range
K8AK-AS1: 2 to 20 mA AC/DC
10 to 100 mA AC/DC
50 to 500 mA AC/DC
K8AK-AS2: 0.1 to 1 A AC/DC (Compatible with commercially available CTs.)
Operating value setting range (SV) 0.5 to 5 A AC/DC (Compatible with commercially available CTs.)
0.8 to 8 A AC/DC
K8AK-AS3: When used with the OMRON CT (K8AC-CT200L).
10 to 100 A AC
20 to 200 A AC
Operating value 100% operation at set value
Reset value setting range (HYS.) 5% to 50% of operating value
Manual reset/automatic reset (switchable)
Reset method Note: Manual reset: Turn OFF power supply for 1 s or longer.
Operating time setting range (T) 0.1 to 30 s
0 to 30 s
Startup lock time setting range (LOCK)
(The startup lock timer starts when the input has reached approximately 30% or more of the set value.)
Note: Enabled only for overcurrent operation. Note: Enabled only for overcurrent operation.
Indicators Power (PWR): Green, Relay output (RY): Yellow, Alarm outputs (ALM): Red
Input impedance Refer to Input Range on this page.
Output relays One SPDT relay (NO/NC switched using DIP switch.)
Rated load
Resistive load
5 A at 250 VAC
5 A at 30 VDC
Output relay ratings Maximum switching capacity: 1,250 VA, 150 W
Minimum load: 5 VDC, 10 mA (reference values)
Mechanical life: 10 million operations min.
Electrical life: 5 A at 250 VAC or 30 VDC: 50,000 operations
3 A at 250 VAC/30 VDC:100,000 operations
Ambient operating temperature −20 to 60°C (with no condensation or icing)
Storage temperature −25 to 65°C (with no condensation or icing)
Ambient operating humidity 25% to 85% (with no condensation)
Storage humidity 25% to 85% (with no condensation)
Altitude 2,000 m max.
Terminal screw tightening torque 0.49 to 0.59 N·m
Recommended wire
Solid wire: 2.5 mm2
Twisted wires: AWG16, AWG18
Note: 1. Ferrules with insulating sleeves must be used with twisted wires.
Terminal wiring method 2. Two wires can be twisted together.
Recommended ferrules
Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact
Al 1-8RD (for AWG18) manufactured by Phoenix Contact
Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact
Case color N1.5
Case material PC and ABS, UL 94 V-0

2
K8AK-AS

Weight Approx. 150 g


Mounting Mounts to DIN Track
Dimensions 22.5 × 90 × 100 mm (W×H×D)

Specifications
Allowable operating voltage
85% to 110% of power supply voltage
range
Allowable operating frequency
50/60 Hz ±5 Hz
range
K8AK-AS1 and K8AK-AS2: DC input or AC input (45 to 65 Hz)
Input frequency range
K8AK-AS3: AC input (45 to 65 Hz)
K8AK-AS1 and K8AK-AS2: Continuous input at 120% of maximum input, 1 s at 150%
Overload capacity K8AK-AS3: Continuous input at 120%, 30 s at 200%, and 1 s at 600% with an OMRON CT (K8AC-CT200L)
Note: Overload capacity of primary side of CT.
Operating value ±0.5% full scale (at 25°C and 65% humidity, rated power supply voltage, DC or 50/60 Hz sine wave input)
Repeat error
Operating time ±50 ms (at 25°C and 65% humidity, rated power supply voltage)
Conforming EN 60947-5-1
standards Installation environment (pollution level 2, installation category III)
Applicable
EMC EN 60947-5-1
standards
UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA: C22.2 No.14,
Safety standards
CCC: GB/T 14048.5
20 MΩ min.
Between external terminals and case
Insulation resistance Between power supply terminals and input terminals
Between power supply terminals and output terminals
Between input terminals and output terminals
2,000 VAC for one minute
Between external terminals and case
Dielectric strength Between power supply terminals and input terminals
Between power supply terminals and output terminals
Between input terminals and output terminals
1,500 V power supply terminal common/normal mode
Noise immunity
Square-wave noise of ±1 μs/100 ns pulse width with 1-ns rise time
Frequency 10 to 55 Hz, 0.35-mm single amplitude
Vibration resistance
10 sweeps of 5 min each in X, Y, and Z directions
Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes
Degree of protection Terminals: IP20

●Relationship of Mounting Distance between K8AK-AS Relays and Input Current (Reference Values)
The following diagram shows the relationship between the mounting distances and the input current. If the relay is used with an input current that
exceeds these values, the temperature of the K8AK may rise and shorten the life of the internal components.
AS (I3 terminal)

I=1A

60
Ambient temperature [°C]

50
I=8A
I=5A
40 I=3A

30 Test method
Sample: K8AK-AS
20 Applied voltage: 240 VAC
Mounting distances: 0, 5, and 10 mm min.

10 K8AK K8AK K8AK K8AK K8AK


No.1 No.2 No.3 No.4 No.5

0 5 10 15
Distance between products d [mm] DIN Track Distance between products: d

3
K8AK-AS
Connections
Terminal Diagram
K8AK-AS1 100-240VAC
A B

Control Output
A Current Input
Relay output A1 C A2
AS1 AS2 AS3
250 VAC, 5 A (resistive load)
30 VDC, 5 A (resistive load)
I1 I2 I3 C C C
B Power Supply Voltage

100 A max.

200 A max.
100 mA max.

500 mA max.
20 mA max.

1 A max.

5 A max.

8 A max.
100 to 240 VAC 24 VAC/DC CT CT

A1 A2 A1 A2

I1 I2 I3 I1 I2 I3 I1 I2 I3

Relay Output
(No polarity)
Common

11 12 14
11 12 14

Note: 1. Do not connect anything to terminals that are shaded in gray.


2. There is no polarity for the DC power supply input.
3. For the current input, you can input only from the C terminal and one other terminal.
4. Refer to Setting Ranges and Wiring Connections on the I1, I2, and I3 current input terminals.
5. Use the recommended ferrules if you use twisted wires.
6. The K8AK-AS3 is designed to be used in combination with the OMRON K8AC-CT200L Current Transformer (CT).

Wiring Example
Directly Inputting a Current Using a CT

Single-phase Single-phase
power supply Load power supply Load

CT
Power supply A2 Power A2
voltage A1 supply voltage A1
A1 C A2 A1 C A2

I1 I2 I3 I1 I2 I3

Power Power
supply supply
AC/DC AC/DC

11 12 14 11 12 14

Timing Charts
●Overcurrent Operation Diagram ●Undercurrent Operation Diagram
(Output Relay Drive Method: Normally Open) (Output Relay Drive Method: Normally Closed)
DIP switch setting: SW3 OFF, SW4 OFF DIP switch setting: SW3 ON, SW4 ON

Power supply Power supply


voltage voltage

Set value
Hysteresis
Input
Input 30% of operating value Set value
Flashing Hysteresis
Flashing (5% to 50% of operating value)
Alarm indicator Alarm indicator
Lit Lit
Relay 11-14 Relay 11-14

Relay 11-12 Relay 11-12

Delay: 250 ms (reference value) Delay: 250 ms (reference value)


Power ON lock Power ON lock
(approx. 1 s) t: Operating time (0.1 to 30 s) (approx. 1 s) t: Operating time (0.1 to 30 s)
t t
LOCK: Startup lock time (0 to 30 s)
LOCK

4
K8AK-AS
Nomenclature
Front ●Indicators
Item Meaning
Terminal block
(See notes 1 and 2.) Power indicator
Lit when power is being supplied.
(PWR: Green)
Relay status indicator
Lit when relay is operating.
(RY: Yellow)
Lit when there is an overcurrent or un-
Current knob (SV)
dercurrent.
Alarm indicator The indicator flashes to indicate the er-
Power indicator (ALM: Red) ror status after the input has exceeded
the set value while the operating time
Hysteresis knob (HYS.)
Relay status indicator is being clocked.

Alarm indicator
Operating time knob (T)
●Setting Knobs
Item Usage
Startup lock time knob
(LOCK) Used to set the current to 10% to 100%
Current knob (SV)
of maximum setting range.
Used to set the rest value to 5% to 50%
Hysteresis knob (HYS.)
of the operating value.
Used to set the operating time to 0.1 to
Operating time knob (T)
Terminal block 30 s.
(See notes 1 and 2.)
Startup lock time knob Used to set the startup lock time to 0 to
(LOCK) 30 s.
Note: 1. Use either a solid wire of 2.5 mm2 maximum or a ferrule with
insulating sleeve for the terminal connection.
The length of the exposed current-carrying part inserted into
the terminal must be 8 mm or less to maintain dielectric
strength after connection.

For 2.5 mm2 or For ferrules with


smaller solid wires an insulation sleeve.

8 mm max. 8 mm max.

Recommended ferrules
Phoenix Contact
• Al 1,5-8BK (for AWG16)
• Al 1-8RD (for AWG18)
• Al 0,75-8GY (for AWG18)
2. Tightening torque: 0.49 to 0.59 N·m

5
K8AK-AS
Operation Methods
Setting Ranges and Wiring Connections
Model Setting range Input type Wiring connections
2 to 20 mA AC/DC Direct input I1-COM Note: The DC input terminals have no polarity.
K8AK-AS1 10 to 100 mA AC/DC Direct input I2-COM * The K8AK-AS3 is designed to be used in combination
with the OMRON K8AC-CT200L Current Transformer
50 to 500 mA AC/DC Direct input I3-COM (CT). (Direct input is not possible.)
0.1 to 1 A AC/DC Direct input or I1-COM
commercially
K8AK-AS2 0.5 to 5 A AC/DC available CT I2-COM
0.8 to 8 A AC/DC Direct input I3-COM
10 to 100 A AC* OMRON CT I2-COM
K8AK-AS3
20 to 200 A AC* OMRON CT I3-COM

Connections
●Input <For K8AK-AS3>
Connect the input between the I1-COM, I2-COM, or I3-COM terminals, according to the input Single-phase power
current. Malfunctions may occur if the input is connected to unused terminals and the Unit will
not operate correctly.
K8AK-AS3
Terminal I1 is not used by the K8AK-AS3.
If using the OMRON K8AC-CT200L CT, connect to terminals k and l on the K8AC-CT200L. A1
Power supply
(Terminals kt and lt are not used.) voltage
●Power Supply A2
K8AC-
Connect the power supply to terminals A1 and A2. CT200L I1
●Outputs k Current input
I2
I3
Terminals 11, 12, and 14 are the output terminals (SPDT) for overvoltage.
C (COM)
Note: Use the recommended ferrules if using twisted wires. l
14
11
Signal output Relay
12 signal
DIP Switch Settings output
The resetting method, relay drive method, and operating mode are set using the DIP switch
located on the bottom of the Unit. Load
K8AK-AS@ does not use SW1.

●DIP Switch Functions


OFF OFF ● ↑ 1 2 3 4
OFF
Pin
ON
ON ❍ ↓ ON

Manual reset ● --- ---


Resetting method
SW4 Automatic reset ❍ --- ---
SW3
SW2 DIP switch pins Normally open --- ● ---
SW1
Relay drive method Normally Not used.
--- ❍ ---
closed
Overcurrent --- --- ●
Operating mode
Undercurrent --- --- ❍
Note: All pins are set to OFF by default.

Setting Method
●Setting Current
The current knob (SV) is used to set the current.
The current can be set to 10% to 100% of the maximum setting range.
Turn the knob while there is an input to the input terminals until the alarm indicator flashes (when the set value and the input have reached the
same level.)
Use this as a guide to set the current.
The maximum setting range will differ depending on the model and the input terminal.
Example: K8AK-AS3 Using Input Terminals I3-COM
The maximum setting range will be 200 A AC and the setting range will be 20 to 200 A.
●Hysteresis
Hysteresis is set using the hysteresis knob (HYS.)
The setting range is 5 to 50% of the operating value.
Example: Maximum of 200 A AC, Current Set Value (SV) of 50%, and Overcurrent Operation
Operation will be at 100 A and resetting at 90 A when the hysteresis (HYS.) is set to 10%.

6
K8AK-AS
●Operating Time
The operating time is set using the operating time knob (T).
The operating time can be set to between 0.1 and 30 s.
If the input current exceeds (drops lower than) the set value, the alarm indicator will start flashing for the set period and then stay lit.
●Startup Lock Time Inrush current
The startup lock time is set using the startup lock time knob (LOCK).
The startup lock time can be set to between 0 and 30 s. Current set value
The startup lock time will start when the input current reaches 30% or more of the set value.
Use startup lock time to prevent unwanted operation, e.g., as a result of inrush current.
Note: Enabled only for overcurrent operation. 30% of current
set value
Startup lock time
There are no outputs
Startup lock timer start during this period.

Dimensions (Unit: mm)

Single-phase Current Relays


K8AK-AS1 22.5 100

K8AK-AS2
K8AK-AS3

90

72 5

OMRON CT
K8AC-CT200L 9.3 9.3
1.7 1.7

4.7
11
63
Four M4 × 6 screws 20 Mounting Hole Dimensions
54
17
50

8.5 13.5
Two M5 screw holes or
34.5 two 5.5-dia. holes
81.5

33.5 76

6
57 30 dia.
14.5 14.5
86
5.2
Note: The OMRON Current Transformer (CT) is
10
10
20 designed to be used with the K8AK-AS3.
Use terminals k and l for connections.
1.8
(Terminals kt and lt are not used.)
4.1 76 5.9

Optional Parts for DIN Track Mounting


●DIN Tracks 7.3±0.15
4.5
PFP-100N
35±0.3 27±0.15
PFP-50N
15 25 25 25 25 15 (5)* 1
10 10
1,000 (500)*

*Dimensions in parentheses are for the PFP-50N.

7
K8AK-AS

Questions and Answers


Q Checking Operation
Q
Can a motor with a rated current of 5 A be
monitored using the K8AK?
Overcurrents Are there any application precautions?
Gradually increase the input from 80% of the set value. The K8AK-AS1 and K8AK-AS2 cannot be used with motor
The input will equal the operating value when the input loads. Use the K8AK-AS3 in combination with the K8AC-
exceeds the set value and the alarm indicator starts flashing. CT200L Current Transformer (CT). With motor loads, the
Operation can be checked by the relay outputs that will start startup current and stall current will cause a current of many
after the operating time has passed. times the rated current to flow. Refer to the following figure for
Undercurrent information on the motor startup current.
Gradually decrease the input from 120% of the setting and
check the operation using the same method as for

Motor current (percentage of rated value)


500%
overcurrent.
Example: Overcurrent Operating Mode, Normally Open Relay Drive,
and an Operating Time of 5 s

Set value

Current input

Flashing Lit
100%
Alarm indicator
5s Several seconds to
several tens of seconds
Relay output
Time from beginning of startup
Connection Diagram For a motor with a rating of 5 A, the startup current will be
approximately 30 A. The startup current will exceed the
Output
A overload capacity (rating: 150% for 1 s) of the K8AK-AS1 and
Input terminals
30 Ω 0 to 10 A K8AK-AS2 and result in failure of the Relay.
100 VAC 400 W (two in parallel)
A1 To monitor the motor load, use the K8AK-AS3. (Overload
Power
supply A2
capacity: 120% of rating for continuous load, 200% of rating for
Variable autotransformer
30 s, and 600% of rating for 1 s).
The K8AK-AS3 has a large input range. Pass the conductors
multiple times through the special CT.
100 VAC

Primary-side conductor

To the K8AK-AS3
± C 100 V
Cycle counter
K8AC-CT200L

Concept behind Passing Conductor through the CT When


Q How to Measure the Operating Time Using the K8AK-AS3
Overcurrent Example: Monitoring Overload of a Motor with a Rated Current of 5 A
Change the input suddenly from 0% to 120% of the set value K8AK set value:
and measure the time until the Unit operates. Overcurrent detection, operating value setting: 25%, operating time: 0.1 s
Undercurrent Startup lock timer: 0.1 to 30 s (Set the timer according to the duration of the
Change the input suddenly from 120% to 0% of the set value startup current.)
and measure the time until the Unit operates. The setting range for the K8AK-AS3 is 10% to 100% of the rated
current (i.e., 10 to 100 A). Pass the conductors through the CT five
times so that at least 10 A of current flows. The input current to the
Q Monitoring Switch-mode Power Supplies
K8AK will be 25 A (i.e., 5 A x 5 loops).
If a startup current of six times the rated current is generated, it will be
Switch-mode Power Supplies cannot be monitored. In circuits
150 A (i.e., 25 A x 6). The overload capacity for the K8AK-AS3 is
with a capacitor input, including switch-mode power supplies,
200% of the rating for 30 s. The Relay will not fail even if the startup
the input capacitor recharge current flows in pulse form as the
current continues for 30 s, and it is possible to perform overload
load current. The K8AK-AS@ has a built-in filter as a
detection.
countermeasure against high frequencies and cannot be
used to remove pulse current.

8
K8AK-AS
Safety Precautions
Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/.

Warning Indications
CAUTION
Indicates a potentially hazardous situation
CAUTION which, if not avoided, may result in minor or
Electrical shock may cause minor injury.
moderate injury or in property damage.
Do not touch terminals while electricity is being supplied.
Precautions for Safe Supplementary comments on what to do or
Use avoid doing, to use the product safely.
Precautions for Supplementary comments on what to do or
Correct Use avoid doing, to prevent failure to operate, There is a risk of minor electrical shock, fire, or device failure.
malfunction, or undesirable effects on Do not allow any pieces of metal, conductors, or cutting chips
product performance. that occur during the installation process to enter the product.

Meaning of Product Safety Symbols Explosions may cause minor injuries. Do not use the product
in locations with inflammable or explosive gases.

Used to warn of the risk of electric shock under There is a risk of minor electrical shock, fire, or device failure.
specific conditions. Do not disassemble, modify, repair, or touch the inside of the
product.

Used for general prohibitions for which there is no Loose screws may cause fires. Tighten terminal screws to the
specific symbol. specified torque of 0.49 to 0.59 N·m.

Used to indicate prohibition when there is a risk of


minor injury from electrical shock or other source if Use of excessive torque may damage the terminal screws.
the product is disassembled. Tighten terminal screws to the specified torque of 0.49 to
0.59 N·m.
Used for general mandatory action precautions for
which there is no specified symbol.
Use of the product beyond its life may result in contact welding
or burning. Make sure to consider the actual operating
conditions and use the product within its rated load and
electrical life count. The life of the output relay varies
significantly with the switching capacity and switching
conditions.

9
K8AK-AS

Precautions for Safe Use Precautions for Correct Use


1. Do not use or store the product in the following locations.
• Locations subject to water or oil Observe the following operating
• Outdoor locations or under direct sunlight methods to prevent failure and
• Locations subject to dust or corrosive gases (particularly malfunction.
sulfurizing gases, ammonia, etc.)
• Locations subject to rapid temperature changes 1. Use the power supply voltage, input power, and other power
supplies and converters with suitable capacities and rated
• Locations prone to icing and dew condensation outputs.
• Locations subject to excessive vibration or shock 2. Use a precision screwdriver or similar tool to adjust the setting
knobs.
• Locations subject to wind and rain
3. The distortion in the input waveform must be 30% max. If the
• Locations subject to static electricity and noise input waveform is distorted beyond this level, it may cause
• Habitats of insects or small animals unnecessary operation.
2. Use and store the product in a location where the ambient 4. Error will be large if the product is used for thyristor or inverter
temperature and humidity are within the specified ranges. If control.
applicable, provide forced cooling. 5. To reduce the error in the setting knob, always turn the setting
3. Mount the product in the correct direction. knob from the minimum setting toward the maximum setting.
4. Check terminal polarity when wiring and wire all connections 6. When cleaning the product, do not use thinners or solvents. Use
correctly. The power supply terminals do not have polarity. commercial alcohol.
5. Do not wire the input and output terminals incorrectly.
6. Make sure the power supply voltage and loads are within the Correct Mounting Direction, Mounting,
specifications and ratings for the product.
and Removing
7. Make sure the crimp terminals for wiring are of the specified size.
8. Do not connect anything to terminals that are not being used. • Mounting to DIN Track
9. Use a power supply that will reach the rated voltage within 1 1. Attach the product to the DIN Track with the tab at the top and
second after the power is turned ON. the hooks at the bottom.
10.Keep wiring separate from high voltages and power lines that 2. Push the product onto the Track until the hooks lock into place.
draw large currents. A B
Do not place product wiring in parallel with or in the same path as
high-voltage or high-current lines.
11.Do not install the product near equipment that generates high
frequencies or surges.
12.The product may cause incoming radio wave interference. Do not
use the product near radio wave receivers.
13.Install an external switch or circuit breaker and label it clearly so
that the operator can quickly turn OFF the power supply.
14.Make sure the indicators operate correctly. Depending on the
application environment, the indicators may deteriorate
prematurely and become difficult to see.
15.Do not use the product if it is accidentally dropped. The internal • Removing from the DIN Track
components may be damaged. Pull down on the bottom hook with a flat-blade screwdriver and lift
16.Be sure you understand the contents of this catalog and handle up on the product.
the product according to the instructions provided.
17.Do not install the product in any way that would place a load on it.
18.When discarding the product, properly dispose of it as industrial
waste.
19.When using the product, remember that the power supply
terminals carry a high voltage.
20.The product must be handled only by trained electrician.
21.Prior to operation, check the wiring before you supply power to Applicable DIN Tracks:
the product. PFP-100N (100 cm)
22.Do not install the product immediately next to heat sources. PFP-50N (50 cm)

23.Perform periodic maintenance.

Adjusting the Setting Knobs


• Use a screwdriver to adjust the setting knobs. The knobs have a
stopper that prevents them from turning beyond the full right or left
position. Do not force a knob beyond these points.

Setting knob

10
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.

Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.


OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.

Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.

Errors and Omissions.


Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation Industrial Automation Company Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V. OMRON ELECTRONICS LLC
Wegalaan 67-69-2132 JD Hoofddorp One Commerce Drive Schaumburg,
The Netherlands IL 60173-5302 U.S.A.
Tel: (31)2356-81-300/Fax: (31)2356-81-388 Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD. © OMRON Corporation 2014 All Rights Reserved.
No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, In the interest of product improvement,
Alexandra Technopark, 200 Yin Cheng Zhong Road, specifications are subject to change without notice.
Singapore 119967 PuDong New Area, Shanghai, 200120, China CSM_4_5_0619
Tel: (65) 6835-3011/Fax: (65) 6835-2711 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Cat. No. N179-E1-01 0513
0314 (0314)