0% found this document useful (0 votes)
110 views

YW Series - Pushbuttons

This document provides specifications for YW series control units with space-saving, thin style contact blocks. Key details include: - The units have separable operator parts for easy handling, small size, screw terminals for safety, and separable contact blocks for easy installation and removal. - Pilot lights have a large lens for wide viewing and non-glare surfaces to reduce light reflection. - Units are UL, c-UL, and EN compliant and CCC approved. Contact ratings are provided for AC and DC loads up to 600V. - Pushbutton and selector switch models are detailed along with their contact configurations, button colors, and packaging quantities.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
110 views

YW Series - Pushbuttons

This document provides specifications for YW series control units with space-saving, thin style contact blocks. Key details include: - The units have separable operator parts for easy handling, small size, screw terminals for safety, and separable contact blocks for easy installation and removal. - Pilot lights have a large lens for wide viewing and non-glare surfaces to reduce light reflection. - Units are UL, c-UL, and EN compliant and CCC approved. Contact ratings are provided for AC and DC loads up to 600V. - Pushbutton and selector switch models are detailed along with their contact configurations, button colors, and packaging quantities.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ø22 YW SERIES CONTROL UNITS

Space-saving, thin style contact blocks


Separable operator part makes handling easy
• Small & light-weight
• Finger-safe screw terminals of IP20
(IEC 60529) enhance safety.
• Separate contact block makes
installing and removing easy.
• Pilot lights feature a large lens to
ensure a wide viewing angle for
increased safety.
• Non-glare matte surfaces on the but-
ton, lens, and bezel reduce reflection
of ambient light.
• UL, c-UL listed, EN compliant, and
CCC approved.

Contact Ratings (Contact Block) Specifications


Rated Insulation Voltage 600V Operating temperature: -20 to +55°C (no freezing)
Rated Thermal Current 10A Operating Operating humidity: 45 to 85% RH (no condensation)
Conditions Storage temperature: -45 to +80°C
Operating Voltage 24V 120V 240V 380V Storage humidity: 95% RH maximum
AC Resistive Load (AC-12) 10A 10A 6A 2A Degree of From panel front: IP65 (IEC 60529)
50/60 Hz Inductive Load (AC-15) 10A 6A 3A 1.9A Protection Terminal: IP20 (IEC 60529)
Resistive Load (DC-12) 8A 2.2A 1.1A – Insulation
DC 100 MΩ
Resistance
Inductive Load (DC-13) 4A 1.1A 0.55A –
Dielectric Contact block: 3500V, 1 minute
Strength Pilot light: 2100V, 1 minute
LED Lamp Ratings Vibration Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Type No. Rated Voltage Rated Current Color Code Resistance Damage limits: 30 Hz, amplitude 1.5 mm
10 mA (A, R, Y) Shock Operating extremes: 100 m/s2
LSED-6∗ 6V AC/DC
7 mA (G, PW, S) Resistance Damage limits: 1000 m/s2
A (amber)
13 mA (A, R, Y) G (green)
LSED-1∗ 12V AC/DC <Pushbutton and illuminated pushbutton>
11 mA (G, PW, S) PW (pure white) Momentary: 5,000,000 operations minimum
15 mA (A, R,Y) R (red) Mechanical
LSED-2∗ 24V AC/DC Maintained: 250,000 operations minimum
14 mA (G, PW, S) S (blue) Life
<Selector switch>
LSED-H∗ 110V AC/DC 5.5 mA Y (yellow)
250,000 operations minimum
LSED-M3∗ 230/240V AC/DC 2.7 mA Pushbutton: 100,000 operations minimum
Electrical Life
Selector switch: 100,000 operations minimum
Note: Specify a color code in place of ∗ in the Type No.
Yellow LED lamps are used for white illumination of pilot lights and illu-
minated pushbuttons.
Mounting Hole Layout
R0.8 max.
Incandescent Lamp Ratings 3.2 +0.2
ø22 0 The 3.2 recess is necessary
Type No. Rated Voltage Ratings .3 +0.4 when the anti-rotation ring is
0
24.1 +0.4

LS-T6 6V AC/DC 6.3V 1W used.


0

LS-T8 12V AC/DC 18V 1W


LS-T3 24V AC/DC 30V 1W

A B

Unit A (mm) B (mm)


Pushbutton
50 min. 30 min.
Selector Switch
Mushroom Pushbutton 50 min. 40 min.
Pilot Light 30 min.* 30 min.

* Keep a minimum spacing of 50 mm when using a lamp of over 1W.

4
YW SERIES CONTROL UNITS ø22
Pushbuttons
Style Operation Contact Type No. Button Color Code Package Quantity
Flush 1NO YW1B-M1E10∗P B (black)
G (green)
R (red)
1NC YW1B-M1E01∗P
S (blue)
W (white)
2NO YW1B-M1E20∗P Y (yellow)

2NC YW1B-M1E02∗P

Momentary 1NO-1NC YW1B-M1E11∗P

3NO YW1B-M1E30∗P

3NC YW1B-M1E03∗P
5
2NO-1NC YW1B-M1E21∗P

1NO-2NC YW1B-M1E12∗P

1NO YW1B-A1E10∗P

1NC YW1B-A1E01∗P

Maintained 2NO YW1B-A1E20∗P

2NC YW1B-A1E02∗P

1NO-1NC YW1B-A1E11∗P

Extended 1NO YW1B-M2E10∗P B (black)


G (green)
R (red)
1NC YW1B-M2E01∗P
S (blue)
W (white)
Momentary 2NO YW1B-M2E20∗P Y (yellow)

2NC YW1B-M2E02∗P

1NO-1NC YW1B-M2E11∗P
5
1NO YW1B-A2E10∗P

1NC YW1B-A2E01∗P

Maintained 2NO YW1B-A2E20∗P

2NC YW1B-A2E02∗P

1NO-1NC YW1B-A2E11∗P

Mushroom ø40mm 1NO YW1B-M4E10∗P B (black)


G (green)
R (red)
1NC YW1B-M4E01∗P
S (blue)
W (white)
Momentary 2NO YW1B-M4E20∗P Y (yellow)

2NC YW1B-M4E02∗P

1NO-1NC YW1B-M4E11∗P
5
1NO YW1B-A4E10∗P

1NC YW1B-A4E01∗P

Maintained 2NO YW1B-A4E20∗P

2NC YW1B-A4E02∗P

1NO-1NC YW1B-A4E11∗P

Note: Specify a button color code in place of ∗ in the Type No.

5
ø22 YW SERIES CONTROL UNITS
Dimensions (Pushbuttons)
Panel Thickness: 0.8 to 6
Gasket

10
10
0.5
M3.5 Terminal Screw
Contact Block Lock

Locking Ring
· Flush

(Button Diameter)

28.6
ø23.6

41.4
9
ø2

45.8 11 30

· Extended

(Button Diameter)

28.6
ø23.6

41.4
9
ø2
11
45.8 19 30

· Mushroom
(Button Diameter)

28.6

41.4
ø40

11
45.8 20.5 30

All dimensions in mm.