This document summarizes the design of a concrete column (C6) according to IS 456:2000 standards. It provides the column details, material properties, design parameters, and results of the axial force, moment, shear, and additional moment design checks. The column has a cross section of 12x12 inches and is 2844.8 mm long. The design checks show it has sufficient capacity for the applied axial load of 391.9 kN and moments of 64.4 kN-m and -7.8 kN-m. The required rebar area is 1298 mm2 or 1.4% of the gross section.

Uploaded by

Anish Neupane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views

Col PDF

This document summarizes the design of a concrete column (C6) according to IS 456:2000 standards. It provides the column details, material properties, design parameters, and results of the axial force, moment, shear, and additional moment design checks. The column has a cross section of 12x12 inches and is 2844.8 mm long. The design checks show it has sufficient capacity for the applied axial load of 391.9 kN and moments of 64.4 kN-m and -7.8 kN-m. The required rebar area is 1298 mm2 or 1.4% of the gross section.

Uploaded by

Anish Neupane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ETABS 2016 16.2.

1 License #*1DCCS8XQSQDQZCV

ETABS 2016 Concrete Frame Design


IS 456:2000 Column Section Design

Column Element Details Type: Ductile Frame (Summary)


Level Element Unique Name Section ID Combo ID Station Loc Length (mm) LLRF
Story1 C6 24 COL12X12 UDCon9 0 2844.8 0.8

Section Properties
b (mm) h (mm) dc (mm) Cover (Torsion) (mm)
304.8 304.8 54.1 28.1

Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
22360.68 20 1 500 500

Design Code Parameters


ɣC ɣS
1.5 1.15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Pu Design Mu2 Design Mu3 Minimum M2 Minimum M3 Rebar Area Rebar %
kN kN-m kN-m kN-m kN-m mm² %
391.8691 64.4409 -7.8374 7.8374 7.8374 1298 1.4

Axial Force and Biaxial Moment Factors


K Factor Length Initial Moment Additional Moment Minimum Moment
Unitless mm kN-m kN-m kN-m
Major Bend(M3) 0.734774 2489.2 2.931 0 7.8374
Minor Bend(M2) 0.705852 2489.2 25.7763 0 7.8374

Shear Design for Vu2 , Vu3


Shear Vu Shear Vc Shear Vs Shear Vp Rebar Asv /s
kN kN kN kN mm²/m
Major, Vu2 20.9598 66.9262 30.5649 20.9598 337.85
Minor, Vu3 57.764 66.9262 30.5649 57.764 337.85

Joint Shear Check/Design


Joint Shear Shear Shear Shear Joint Shear
Force VTop Vu,Tot Vc Area Ratio
kN kN kN kN cm² Unitless
Major Shear, Vu2 N/A N/A N/A N/A N/A N/A
Minor Shear, Vu3 N/A N/A N/A N/A N/A N/A

ANJANABTTRAI.EDB Page 1 of 2 2/28/2019


ETABS 2016 16.2.1 License #*1DCCS8XQSQDQZCV

(1.1) Beam/Column Capacity Ratio


Major Ratio Minor Ratio
N/A N/A

Additional Moment Reduction Factor k (IS 39.7.1.1)


Ag Asc Puz Pb Pu k
cm² cm² kN kN kN Unitless
929 13 1323.0282 318.8659 391.8691 0.927299

Additional Moment (IS 39.7.1)


Consider Length Section KL/Depth KL/Depth KL/Depth Ma
Ma Factor Depth (mm) Ratio Limit Exceeded Moment (kN-m)
Major Bending (M3 ) Yes 0.875 304.8 6.001 12 No 0
Minor Bending (M2 ) Yes 0.875 304.8 5.764 12 No 0

Notes:

N/A: Not Applicable

N/C: Not Calculated

N/N: Not Needed

ANJANABTTRAI.EDB Page 2 of 2 2/28/2019

You might also like