Performance-Based Design: An Approach Towards Safer, Reliable Structures
Performance-Based Design: An Approach Towards Safer, Reliable Structures
net/publication/275346726
CITATIONS READS
0 2,104
1 author:
Naveed Anwar
Asian Institute of Technology
142 PUBLICATIONS 59 CITATIONS
SEE PROFILE
Some of the authors of this publication are also working on these related projects:
Seismic Performance Evaluation of High-rise Buildings with RC Flag Wall Systems View project
All content following this page was uploaded by Naveed Anwar on 24 April 2015.
A
sia’s recent dominance of the tall-building The Los Angeles Tall Buildings Structural Design Council
industry is evident from the 2014 annual report (LATBSDC) provides several reasons justifying why PBD is
of the Council on Tall Buildings and Urban Habitat a valid, and preferable option, compared to the traditional
(CTBUH), accounting 74 of the 97 tall buildings completed code based design, both for tall buildings and other struc-
in 2014, or 76%, were in Asia. Trends show the number of tures:
buildings and building height to be increasing, increasing
the need for more skilled engineers, equipped with better • Code provisions are intended to provide a
tools to evaluate and guarantee the safety and perfor- minimum level of safety for engineered buildings.
mance of such buildings. The code prescriptive provisions are intended to
provide safe design criteria for all types of buildings,
Undeniably, as the tall buildings and complex structures ranging from small one and two-story dwellings Author:
are becoming more prevalent in our world today, the to the tallest structures. As a result of this broad
concern for the safety of the public from various natural intended applicability, the provisions contain many
and man made hazards is becoming more relevant. So requirements that are not specifically applicable
when clients and users of the buildings ask a structural to tall buildings and which may result in designs
engineer, an apparently simple question “Is my structure that are less than optimal, both from a cost and Naveed Anwar, Ph.D.
safe?”, engineers are at odds to respond to this explicitly. safety perspective. Executive Director,
Generally, the structural engineers follow the prescriptive AIT Consulting
provisions of the building and design codes, and proba- Director, Asian Center
for Engineering Computations
bly the best answer they could offer is that “I am not sure, and Software (ACECOMS),
but I have designed this structure according the building Affiliate Faculty,
code!” Obviously, such a response may not be sufficient, Structural Engineering,
Asian Institute of Technology
or acceptable, but unless clearer and more refined design
approaches and methodologies are used, this may be the
only choice. The main reasons why an explicit answer is not
possible, are, first, the question itself is not well-defined.
It does not explain what a “safe design” is; and if it is safe
against what effects, and what level of safety is required.
It also does not allow the designer to carry out a clear-cut
understanding and evaluation of the “strength” of the struc-
ture that is not bound by typical simplifications, arbitrary
factors, and prescriptive limits.
HEIGHT
+ +
...
12,000
Combined height of buildings evaluated
> 8,848 m
Mt. Everest
Floor AREA
+ + ...
5 km2
Combined floor area of buildings evaluated
> Monaco + Male + Vatican
WEIGHT
x 60
+ + ...