Test Ray'S Inspection and Engineering Services

1. Test Ray's Inspection and Engineering Services conducted a radiographic examination of a 20" 150 bonnet for L&T Valves Limited. 2. The examination found acceptable indications such as gas holes and inclusions at various locations of the bonnet. 3. The castings were accepted under Level 2 classification.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
171 views2 pages

Test Ray'S Inspection and Engineering Services

1. Test Ray's Inspection and Engineering Services conducted a radiographic examination of a 20" 150 bonnet for L&T Valves Limited. 2. The examination found acceptable indications such as gas holes and inclusions at various locations of the bonnet. 3. The castings were accepted under Level 2 classification.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TEST RAY'S INSPECTION AND ENGINEERING SERVICES

SF.No. 413/3B,MOPPERIPALAYAM(POST),, COIMBATORE., Pincode :641 659.


Phone :0421 - 3269845,96009 44001,02,03, Mail :[email protected] , CST No. :1028619 Dt.01.09.2009

RADIOGRAPHIC EXAMINATION REPORT

M/s. : SCHUTTE MEYER ASHWATH ALLOYS PVT LTD Page 1 of 2

Customer : L&T VALVES LIMITED Report No Page 1 of


: TIES/SMA/2769 - A2

Description : 20" 150 BONNET Report Date : :06/01/2017


Drawing No : LT3B2088R REV.0 Radiography No : SMT146

Grade : WCC Heat No : B5960

Ir-192 Source Strength :35Ci Source Size :2.7MM DIAX1.5HTHT


Date of Test : 30/12/2016
Co-60 Source Strength :40Ci Source Size :3.2MMDIAX2.5HT
Film Type : KODAK AA400 Evaluation Reference : E446/E186

Pb Screen Thickness : 0.1MM BACK 0.15MM Procedure Reference : NDE 001 REV 11
Shooting Technique/IQI : SWSI/ASTM Acceptance Standard : ASME B 16.34 APPENDIX-1
Technique Sheet No : DBBV-11 REV.11 Area of Coverage : 100% AREA
Sl. Location Source Thickness SFD IQI Density Film Size Findings * Classi Remarks
No (mm) (Inch) Designation Sensitivity Inchs fication

1 1-2 Ir - 192 42 24 35 2-2T 2.9 8X4 A 1 Acceptable


2 2-3 Ir - 192 42 24 35 2-2T 2.9 8X4 NSD - Acceptable
3 3-4 Ir - 192 42 24 35 2-2T 2.9 8X4 A 1 Acceptable
4 4-5 Ir - 192 42 24 35 2-2T 2.9 8X4 A 2 Acceptable
5 5-6 Ir - 192 42 24 35 2-2T 2.9 8X4 A 1 Acceptable
6 6-7 Ir - 192 42 24 35 2-2T 2.9 8X4 A 2 Acceptable
7 7-8 Ir - 192 42 24 35 2-2T 2.9 8X4 A 1 Acceptable
8 8-9 Ir - 192 42 24 35 2-2T 2.9 8X4 A 1 Acceptable
9 9-10 Ir - 192 42 24 35 2-2T 2.9 8X4 A 1 Acceptable
10 10-11 Ir - 192 42 24 35 2-2T 2.9 8X4 A 1 Acceptable
11 11-1 Ir - 192 42 24 35 2-2T 3.2 8X4 A 1 Acceptable
12 12-13 Co - 60 74/94 24 45F/50F 2-2T 3.6 8X6 B 1 Acceptable
13 13-14 Co - 60 74/94 24 45F/50F 2-2T 3.6 8X6 B 1 Acceptable
14 14-15 Co - 60 74/94 24 45F/50F 2-2T 3.2 8X6 NSD - Acceptable
15 15-16 Co - 60 74/94 24 45F/50F 2-2T 3.2 8X6 NSD - Acceptable
16 16-17 Co - 60 74/94 24 45F/50F 2-2T 3.6 8X6 NSD - Acceptable
17 17-18 Co - 60 74/94 24 45F/50F 2-2T 3.6 8X6 NSD - Acceptable
18 18-19 Co - 60 74/94 24 45F/50F 2-2T 3.6 8X6 B 1 Acceptable
19 19-20 Co - 60 74/94 24 45F/50F 2-2T 3.2 8X6 NSD - Acceptable
20 20-12 Co - 60 74/94 24 45F/50F 2-2T 3.2 8X6 NSD - Acceptable
21 21-22 Ir - 192 65 24 50 2-2T 3.2 8X4 B 1 Acceptable
22 22-23 Ir - 192 65 24 50 2-2T 3.2 8X4 NSD - Acceptable
23 23-24 Ir - 192 65 24 50 2-2T 3.2 8X4 A 2 Acceptable

*
A : Gas Hole ; B : Inclusion ; CA,CB,CC,CD : Shrinkage ; D : Crack ; E : Hot Tear ; F : Insert ; NSD : No Significant Defect ;

For TEST RAY'S INSPECTION AND


ENGINEERING SERVICES

A.CHELLA PACKIARAJ
LEVEL-II RT SUPPLIER CUSTOMER EXTERNAL INSPECTOR
TEST RAY'S INSPECTION AND ENGINEERING SERVICES
SF.No. 413/3B,MOPPERIPALAYAM(POST),, COIMBATORE., Pincode :641 659.
Phone :0421 - 3269845,96009 44001,02,03, Mail :[email protected] , CST No. :1028619 Dt.01.09.2009

RADIOGRAPHIC EXAMINATION REPORT

M/s. : SCHUTTE MEYER ASHWATH ALLOYS PVT LTD Page 2 of 2

Customer : L&T VALVES LIMITED Report No Page 2 of


: TIES/SMA/2769 - A2

Description : 20" 150 BONNET Report Date : :06/01/2017


Drawing No : LT3B2088R REV.0 Radiography No : SMT146

Grade : WCC Heat No : B5960

Ir-192 Source Strength :35Ci Source Size :2.7MM DIAX1.5HTHT


Date of Test : 30/12/2016
Co-60 Source Strength :40Ci Source Size :3.2MMDIAX2.5HT
Film Type : KODAK AA400 Evaluation Reference : E446/E186

Pb Screen Thickness : 0.1MM BACK 0.15MM Procedure Reference : NDE 001 REV 11
Shooting Technique/IQI : SWSI/ASTM Acceptance Standard : ASME B 16.34 APPENDIX-1
Technique Sheet No : DBBV-11 REV.11 Area of Coverage : 100% AREA
Sl. Location Source Thickness SFD IQI Density Film Size Findings * Classi Remarks
No (mm) (Inch) Designation Sensitivity Inchs fication

24 24-25 Ir - 192 65 24 50 2-2T 3.2 8X4 A 2 Acceptable


25 25-26 Ir - 192 65 24 50 2-2T 3.2 8X4 A 1 Acceptable
26 26-21 Ir - 192 65 24 50 2-2T 3.2 8X4 B 1 Acceptable
27 27 Co - 60 94 24 60 2-2T 3.6 8X6 B 1 Acceptable
28 28 Co - 60 94 24 60 2-2T 3.6 8X6 A 2 Acceptable

Total Area ( Ir 192 ) 544 Sq.Inchs Total No of Film ( Ir 192) 17


Total Area ( Co 60 ) 528 Sq.Inchs Total No of Film ( Co 60 ) 11

CASTINGS ACCEPTED UNDER LEVEL 2


*
A : Gas Hole ; B : Inclusion ; CA,CB,CC,CD : Shrinkage ; D : Crack ; E : Hot Tear ; F : Insert ; NSD : No Significant Defect ;

For TEST RAY'S INSPECTION AND


ENGINEERING SERVICES

A.CHELLA PACKIARAJ
LEVEL-II RT SUPPLIER CUSTOMER EXTERNAL INSPECTOR