0% found this document useful (0 votes)
67 views

Preventa Safety Detection XCSE5311

This document provides product data for a metal safety switch called the XCSE. It is a 3-pole switch with 1 NC + 2 NO contacts for slow break operation and 2 entries tapped for cable entry. It has a 24V solenoid and LED indicators for open/closed status. The switch is IP67 rated and meets various industry safety standards.

Uploaded by

Fernando Moreira
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views

Preventa Safety Detection XCSE5311

This document provides product data for a metal safety switch called the XCSE. It is a 3-pole switch with 1 NC + 2 NO contacts for slow break operation and 2 entries tapped for cable entry. It has a 24V solenoid and LED indicators for open/closed status. The switch is IP67 rated and meets various industry safety standards.

Uploaded by

Fernando Moreira
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product data sheet XCSE5311

Characteristics metal safety switch XCSE - 1NC+2NO - slow


break - 2 entries tapped Pg 13- 24V

Main
Range of product Preventa Safety detection
Product or component Safety switch
type
Component name XCSE
Design Rectangular
Material Metal
Head type Key operated turret head
Contacts type and 1 NC + 2 NO
composition
Contact operation Slow-break, break before make
Solenoid contacts type 1 NC + 1 NO (slow-break, simultaneous)

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
and composition
Cable entry 2 entries tapped for Pg 13.5
Electromagnet Locking on de-energisation and unlocking on
interlocking energisation of solenoid
[Us] solenoid rated supply
24 V - 20...10 %
voltage
Cable outer diameter 9…12 Mm

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
Electrical connection Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm²

This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
with or without cable end

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Number of poles 3
Locking options With interlocking, locking by solenoid
description
Local signalling 2 LEDs (green or orange)guard open/guard closed
and locked:
Signalling circuit voltage 24/48 V (voltage limits: 20...52 V)

Complementary
Positive opening With NC contact
Supply voltage type AC/DC
Supply frequency 50/60 Hz
Load factor 1
Power consumption in VA 10 VA inrush
10 VA sealed
Signalling circuit type AC/DC
Signalling circuit consumption 7 MA
Mechanical durability 1000000 Cycles
Minimum actuation speed 0.01 M/S
Maximum actuation speed 0.5 M/S
[Ie] rated operational current 0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
[Ithe] conventional enclosed thermal current 6 A
[Ui] rated insulation voltage 50 V conforming to EN/IEC 60947-1 for signalling circuit
[Uimp] rated impulse withstand voltage EN/IEC 60947-5-1 6 kV
Protection type Overvoltage protection for signalling circuit
Short-circuit protection 10 A cartridge fuse type gG (gl)
Actuator forcible withdrawal rtc 2000 N
Minimum actuator force for extraction 20 N

Dec 19, 2019


1
Maximum operating rate 10 Cyc/Mn for maximum durability
Safety level Can reach category 4 with the appropriate monitoring system and correctly wired
conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired
conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired
conforming to EN/IEC 61508
Safety reliability data B10d = 5000000 value given for a life time of 20 years limited by mechanical or
contact wear
Body material Zamak
Head material Zamak
Depth 44 Mm
Height 146 Mm
Width 98 Mm
Net weight 1.14 Kg

Environment
Standards EN/IEC 60204-1
EN 1088/ISO 14119
EN/ISO 12100
UL 508
EN/IEC 60947-5-1
CSA C22.2 No 14
Product certifications UL
CSA
Protective treatment TC
Ambient air temperature for operation -25…40 °C
Ambient air temperature for storage -40…70 °C
Vibration resistance 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance 10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class Class I conforming to EN/IEC 61140
IP degree of protection IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS
Declaration
Mercury free Yes
RoHS exemption information
Yes
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information

Contractual warranty
Warranty 18 months