Foundation Plan

The document contains a table with labels A through F across the top and numbers in various cells. It also contains notes about specifications for a construction project, including the minimum steel reinforcement strength, required concrete compressive strength, and maximum aggregate size for beams, columns, and foundations.

Uploaded by

tahaelnour
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views

Foundation Plan

The document contains a table with labels A through F across the top and numbers in various cells. It also contains notes about specifications for a construction project, including the minimum steel reinforcement strength, required concrete compressive strength, and maximum aggregate size for beams, columns, and foundations.

Uploaded by

tahaelnour
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A B C C' D' D E F

1
1.50 5.00 4.00 4.66 10
0.36
1.50 4.00 1.00 4.00 1.00 3.30

15.17
ORTH

NOTES
3.67
3.67

2.50

3.00
3.00
6.40 1.22 1.28 1- Steel fy not less than 460 N/mm2.
3.50
TYPICAL COLUMN
2- Concrete fcu should not be less

0,125

1.22
1.07
MAIN BAR LAPPING

0,600 0,600 1.64 0,176 0,125 than 30N/mm2 for 28days strength.

0,125

0,125
0,300

0,300

0,300
2.20

2.50
4 3-Max-Aggregate size 20mm for

0,300
0,125 C2 C2 0,600 0,600 C2

1.13
beams & col.s and 30mm for found.s.

1.28
0,125 C2
4- Concrete cover for reinforcement
1.14
0.27
should not be less than
25mm for beams & columns and
5.00
5.00

5.00
5.00
3.50
50mm for foundations.
1.47 2.03 3.50 5- Over laps of steel should not be less

6.88
1.68
2.50 1.82 than 45 times larger bar size &should
1.22 1.28
always be located within concrete
1.75

1.40
being under compression.
1.07

0,125 0,800 0,125


0,800
0,150

0,150

0,150
0,125

0,300

0,300

0,300
3.50

3 6- Construction joints shall be located


0,600

2.50

3.50
C1 C1 at onefifth of span of slabs.
1.00

1.00
0,800 C1
1.43

0,125

0,250
C2 7- All Dimensions are in mm.
1.75

0,125

0,500
19.47
19.46

2.10
0,300

0.75
8- Bearing Capacity= 180 KN/m2.

1.09
C3
2''
0.47
3.50
5.50

3.50
5.50
3.50
2.02 1.48
2.50
2' 1.22 1.28

0.95
7.00 0,250

0,250
1.00 1.00

0,500

1.95
0,125
1.42
1.00

1.00

1.00
0,300
0,150 C3 0,125
0,600

3.50
2.50

0,125

0,125

0,300
0,125

2
0,800

0,800

C2 C1
1.08

1.55
C1

1.90
0,300 C1 Bilbaraka For Engineering Consultancy
0,300 0,150 Khartoum - Sudan
Almanshia - Altayeb A.Allah St.
2' Mob. : +249912910731
Email: [email protected]
5.30
5.30

7.30

5.30
2.00
PROJECT TITLE Plot No:
(1168)
2.50 RESIDENTIAL BUILDING
1.23 1.28 2.50 Block No:
1' 0,300
1.52 0.98
(81)
0,300
0,300
1.42

1.40
1.27

0,125 LOCATION
0,800

0,800
0,600

2.50

0,300

2.50

Khartoum - Algeref west


0,125

0,125

0,125

0,125

1
C2 C1 C1
1.00

C1 0,800
1.08

1.23

0,125 0,150 0,150 OWNER


Mr. OTHMAN IBRAHIM ALBOUR

d DRAWING TITLE Job No


FOUNDATION PLAN ISOLATED FOOTING
Scale 1 :100
1.40 2.20 1.40
Str. Design Eng. Sharif Abdallah Agban
2.03 5.00 5.00 3.30
15.33 Str. Design
Eng. Sharif Abdallah Agban
Str. Drafting

Approved By Eng. Taha Elnour Isshage

File name Date Rev. Sheet No


FOUNDATION PLAN ISOLATED FOOTING JUNE-2019 ST-05