Cathodic Protection Training
Cathodic Protection Training
What Is Corrosion
Corrosion in Metals
Detection of Corrosion Metals
Mitigation of Corrosion
Cathodic Protection
Types of Cathodic Protection
Transformer Rectifiers
Surface Anode Ground Beds
Applications
Criteria for CP
100 mV Potential Criteria
1400 1400
1200 1200
1000 1000
800 800
600 600
400 400
200 200
0 0
Polarization Decay
Current Density
( At 300 C, 25% Increase in Every 100 C )
General Arrangement Of
Equipment
Anode Lead Junction Box
Typical Stray Current
Potential Testing of Foreign
Structures
Interference Vs. Potential
Values
General Phases Of CP
Program
ADCO CP Project
Electrical Isolation
CP Current Requirement
Corrosion Potential
Evaluation Tool (CPET)
Logging
CPET Tool and Logs
E-log-i Testing
CP Current Attenuation
0
-1,000
-2,000
-3,000
-4,000
-5,000
-6,000
-7,000
-8,000
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0
Current Density Per Segment
0
-1,000
-2,000
-3,000
-4,000
-5,000
-6,000
-7,000
-8,000
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
Groundbed Details
Preferred Groundbed Location
°°
°
Determining Borehole Depths
14.00
Megger
12.00
10.00
8.00
6.00
4.00
2.00
Drill Rig Wellhead 0.00
3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 54 57 60
Drill Rigs
Deep Anode Groundbed
Details
Cross Section Of Deep Anode
Groundbed
Titanium / MMO Anodes
Coke Breeze Backfill
Anode / Vent Pipe Loading
Deep Anode Installation Rig
Coke Breeze Pumping Operation
Power Supplies
Transformer Rectifiers
Solar Power Supplies
Solar Power Controller
Storage Batteries
Negative Connection To Well
Special Tools
Project CP Criteria
Assessment Of CP Current
To Casing
Commissioning Activities
General Safety
PPE And Safety Equipment
Safety Hazards
Testing
Routine Testing
AC Input Measurement Of
Rectifier
DC Current Output Of
Rectifier
DC Voltage Output of
Rectifiers
Measure and Balance CP Current To Well Casings
(Dual Sites)
Tap Adjustment Of Rectifier
Correct
Wrong
Electronic Components Of
Solar Controller
Solar Power Alarm Settings
Controller Alarm LED’s
CP Controller Adjustments
Normal Operating Display
Shunt Ratings
Shunt Rating / Conversions
EQUIPMENT SHUNT RATING CONVERSION
Anode Current Measurements
Flowline Current Measurements
Interrupting Current Output of
Rectifier
Sample Interference Test
Data
P/S Potential (mV)
Test Location Results
On Off Change
Set-up and Down Loading of
Data Loggers
Data Logger on Rectifiers
Rectifier Data Logger Connection
Set-up of Rectifier Data Logger
Data Logger Set-up Window
(General)
Communication Type Codes
(Unique 5 Digit No.)
Data Logger Set-up Window
(Channel Tab)
Data Logger Set-up Window
(Rectifier Tab)
Data Logger Set-up Window
(Recording Tab)
Down Loading Data Logger
(Status and Tools Window)
Down Loading Data Logger
(Auto Report Window)
Generating Report
Sample Rectifier Data Logger
Report
RMU SYSTEM (by RCS)
SITE REPORT CUMULATIVE
RECTIFIER No: 1 of 1
RELAY NO.: 1
MANUFACTURER: Corrpower
MODEL CSAY 30 -25
SERIAL NO.: 123456
CLASS: Nema 3R
RATING: 30 Volt / 25 Amp
Title: , Interrupter: Idle, Type: On, Start: Scheduled, Transfer Time: 07/23/04 13:19
01 01 01 02 02 02 03 03 03
Date / Time Min. Ave. Max. Min. Ave. Max. Min. Ave. Max.
(V DC) (V DC) (V DC) (V DC) (V DC) (V DC) (A DC) (A DC) (A DC)
Download Menu
Sample Readout of Solar
Power Data Logger
Site: Bu191 Operator: Anis Downloaded: 29-Jul-2004 at 09:30
H
CP RC DI LV LV AY AY L F R C B T
yyyy-mm-dd hh:mm Mode BV Temp AI LI CP I V
V V S A D 1 2 C A F P S S
A
Maintenance
Routine Maintenance
Trouble Shooting
Problem of TR System
AC Power Problem
No DC Voltage
DC Voltage But No DC
Current From T/R
Dummy Load Across Power
Supply
Internal Transformer Rectifier
Problems
Isolate Problem Of Solar
System
Solar Panels
General Problems With Solar
Controllers
Solar Power Supply Schematic
Problems With Charge
Controller
Problems With CP Controller
Batteries
Anode With Low Output
Open DC Output Circuit
High Circuit Resistance