0% found this document useful (0 votes)
319 views

BASF Masterseal 530

This document provides information about MasterSeal 530, a fast curing surface applied capillary waterproofer for concrete and mortar. It describes the product, including its features and benefits, recommended uses, properties, application instructions, coverage estimates, packaging, and storage information.

Uploaded by

JM Subion
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
319 views

BASF Masterseal 530

This document provides information about MasterSeal 530, a fast curing surface applied capillary waterproofer for concrete and mortar. It describes the product, including its features and benefits, recommended uses, properties, application instructions, coverage estimates, packaging, and storage information.

Uploaded by

JM Subion
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MasterSeal® 530 (formerly known as MasterSeal 530 FC)

Fast curing surface applied capillary waterproofer for concrete and mortar

DESCRIPTION  Vapour permeable - Allows surface to


breathe, preventing build up of vapour
MasterSeal 530 fast curing consists of a blend
pressure.
of moisture-activated chemicals, high-grade
silica aggregates and selected cements. It  Brushable consistency - Easy to apply by
waterproofs through the formation and develop- brush or spray.
ment of crystals in water bearing capillaries and  Unrestricted application - Effective against
interstices, effectively blocks the further passage both positive and negative water pressure.
of water and ensures permanent water tightness  One component - Economical to use.
of the structure.
PROPERTIES
Dry Shake MasterSeal 530
on Horizontal Construction
Joints Pull off bond strength 1.7 N/mm2
Supply form Powder
Colour Grey
Density (Mixed) 2.02 kg/lt
Setting time @ 30°C
Initial 15 min (approx.)
Final 50 min (approx.)
Application Temperature > 5°C
MasterSeal 530 application on vertical Toxicity Non toxic
construction and day work joints
RECOMMENDED USES APPLICATION
MasterSeal 530 is recommended for areas such New Construction:
as:
MasterSeal 530 can be applied immediately after
 Static construction joints (new construction) the formwork has been removed, as the water
 Water tanks and towers, reservoirs, dams, curing process required for MasterSeal 530 will
canals also ensure full hydration of the concrete. If
 Water treatment works, harbours treatment is to be exposed and an aesthetically
pleasing finish is required, the MasterSeal 530,
 Concrete pipes, sumps, foundations after curing, should receive a sand / cement render
 Retaining walls, lift shafts onto which the desired finish is applied.
 Sea defence walls, bridge decks, jetties, Existing structures:
pontoons Structures subject to water leakage or ingress
 Fast curing membrane for internal wet area must be carefully inspected to determine the
refurbishment cause. Any water present should be diverted away
so that a thorough survey can be conducted. Static
FEATURES AND BENEFITS cracks over 1mm must be chased out, dampened
 Forms crystals in concrete pores - down and repaired with an MasterEmaco repair
Waterproofs by becoming an integral part of mortar. Dynamic cracks must be formed into
the structure. Active ingredients will not watertight movement joints and sealed, using
delaminate, peel off or wear away. MasterSeal 470 elastomeric sealant.
MasterSeal® 530 (formerly known as MasterSeal 530 FC)

The rate and penetration of crystalline coat whilst the first is firm, but ‘green’ – usually 1-
development will vary with the density and surface 3 hours after first coat (dependant on
absorption of the concrete. temperature). Plugging leaks:
In powder form, the product may be used as a dry Leaks and holes drilled to relieve water pressure
shake on horizontal construction joints. . can be sealed permanently using MasterSeal
Surface Preparation: 590. Slow drying of MasterSeal 530 membrane
ensures homogeneous curing and high
Surfaces to be treated must be free from dust, oil,
waterproofing characteristics. MasterSeal 530
grease, paint, residual curing compound, mould
must be protected against rapid drying due to
oil or any previous surface treatment that will
high temperatures or wind. Cure by wet burlap,
impair adhesion of MasterSeal 530 treatment or
plastic sheet or mist spraying. Curing compounds
inhibit penetration of the chemicals into the
are unsuitable for use with MasterSeal 530
surface. These include polymer modified renders
system technology. Tanks and other water
and those substrates treated with silicon or silane
retaining structures may be filled 24 hours after
water repellents. Areas of weak or honeycombed
final MasterSeal 530 application as crystal
concrete must be repaired. Hollow de-bonded
growth is accelerated by water pressure.
renders must be removed and made good.
Surfaces to be treated that are not damp must be ESTIMATING DATA
pre-wetted and still be damp at the time of The recommended coverage of MasterSeal 530
application. per coat is:
Mixing: By brush : 1 – 1.5 kg/m2
Mechanical mixing is necessary. Mix 25kg of By trowel: 2 – 2.5 kg/m2
MasterSeal 530 with 7 to 8L of water using a Actual consumption depends on the porosity and
slow speed (600rpm), heavy duty electric drill surface profile of the substrate and wastage.
fitted with a grout stirrer.
PACKAGING
When the mixer is running, add clean mixing
water to the MasterSeal 530 powder to achieve MasterSeal 530 is available in 25kg bags.
the consistency required. Mix for at least 3 SHELF LIFE
minutes to get a lump-free, homogeneous and
creamy consistency. If applying to vertical MasterSeal 530 has a shelf life of 12 months.
surfaces, water may have to be reduced to Store out of direct sunlight, clear of the ground on
achieve the desired consistency to minimise the pallets protected from rainfall
run off on the surface. Do not add additional PRECAUTIONS
water after initial mixing.
For the full health and safety hazard information
Placing: and how to safely handle and use this product,
MasterSeal 530 mixes are applied by brush or please make sure that you obtain a copy of the
spray onto the dampened substrate. Apply the BASF Material Safety Data Sheet (MSDS) from
material in 2 coats at right angles, the second our office or our website.

® = registered trademark of BASF group in many countries MasterSeal_530 asean v2-0414


The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF
NOTE Construction Chemicals either orally or in writing may be followed, modified or rejected by the owner, engineer or
contractor since they, and not BASFConstructio Chemicals, are responsible for carrying out procedures
appropriate to a specific application.

BASF Construction Chemicals offices in ASEAN


Singapore Malaysia Indonesia Thailand Vietnam Philippines Hong Kong
Tel: +65-6861-6766 Tel: +60-3-5628-3888 Tel: +62-21-2988-6000 Tel: +66-2-664-9222 Tel: +84-650-374-3100 Tel: +63-2-889-4321 Tel:+852-2408-4400
Fax: +65-6861-3186 Fax: +60-3-5628-3776 Fax: +62-21-2988-5935 Fax: +66-2-664-9267 Fax: +84-650-374-3200 Fax: +63-2-889-4361 Fax:+852-2408-4401

Website: www.ap.cc.basf.com

You might also like