Appendix - 1 Flow Chart For Design of Structural Steel Element
Appendix - 1 Flow Chart For Design of Structural Steel Element
Start
Semi Compact
No Is Yes
V<Vd
? Is
Yes No
V<Vd
Yes
Is No ?
V<0.6Vd
?
Yes
Is No
V<0.6Vd
?
No Is Yes
Md>M
?
End
Design of Steel Building Structural Element AsPer IS800-2007:
Developing a Computational Tool
APPENDIX-1
Start
No Is Yes
Pd>Pxx
?
Slender
Classification
False
True Overall Member Strength
As per IS800-2007 clause 9.3.2.2
End
Start
Actual Prying Qa
Increase No Is Yes
thickness of Plate
Qa<Q Total Tension in Bolt
? (Tension due to moment+
No
Prying+Axial force in beam)
Is
tp > tprec Thickness of plate required under bending (tprec)
? Yes
False
Check for True
Increase Combine Tension and Shear
Bolt Diameter Asper IS 800-2007Clause No10.4.6
Yes
No Is Beam connecting
to the Column flange
?
A B
A B
Web Buckling
Design of Web
Doubler plate
False True
Check for Column Web
Crippling
Design of Web
Doubler plate
End
Start
Calculate ecrit, e
No Is Yes
ecrit < e
?
Nominal anchored rods (Tension Bolt) Calculate strength of anchored rod (Tension Bolt)
Check for
No
Yes Combine Tension and Shear
Asper IS 800-2007Clause No10.4.6
End
Start
Slender
Classification
Plastic \ Compact Semi Compact
No Is Yes
Shear capacity > Shear due to upward pressure
?
Change thickness of plate
No Is Yes
Moment capacity > Moment due to upward pressure
?
End
Start
No Is Yes
Moment capacity > Moment due to upward pressure
?
End