Controller 13KW Triplex-Ing

This document provides parameters and their values for configuring the controller of a duplex 2PE VVVF elevator with automatic doors and closed door parking located in Milan, Italy. It specifies settings for timing parameters like maximum door opening/closing times, engagement time, and travel time. It also provides settings for features like brake control type, lift type, door type, direction control and re-leveling options, number of registered floors, and safety circuit configuration.

Uploaded by

Malik Asif
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
165 views2 pages

Controller 13KW Triplex-Ing

This document provides parameters and their values for configuring the controller of a duplex 2PE VVVF elevator with automatic doors and closed door parking located in Milan, Italy. It specifies settings for timing parameters like maximum door opening/closing times, engagement time, and travel time. It also provides settings for features like brake control type, lift type, door type, direction control and re-leveling options, number of registered floors, and safety circuit configuration.

Uploaded by

Malik Asif
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PELAZZA PEPPINO s.r.l.

Quadri di Manovra per Ascensori e Montacarichi


Lifts Control Panels
20063 CERNUSCO SUL NAVIGLIO (MI) ITALY
Via Ponchielli, 6/8
Tel. 02/9231694 – 02/9242706 – Fax 02/9242706
www.pelazza.com
E-mail: [email protected]

PROGRAM: EURO-INV10 CLIENT: MILAN ASCENSORE Ref: CONTROLLER 13KW TRIPLEX


2PE-PA-NS

Lift: VVVF – duplex 2PE – Automatic Doors – Closed Doors Parking – Not Serial

PARAMETERS TO BE MODIFIED IF THE EURO BOARD SHOULD BE REINITIALIZED

PAR. VALUE MEANING

1 6 (def.) TMA = Maximum opening doors time (to be regulated about 1-2 sec over
the time required to open the doors)

2 6 (def.) TAP = Restarting and open doors parking time

3 8 TCH = Maximum time for doors closing

5 6 TMP = Engagement manoeuvre time (and A67fault signal time (P5)x4 sec)

6 30 TMC = Maximum travel time

8 1 RCPV = Slowing time delay for run between one floor to the next (0.1 sec)

9 4 TOC = Engage time from closing doors start for parking (to be regulated
about 1-2 sec over the time required to close the doors)

10 69 P output used for low speed command

11 12 TRIF = Contactors drop out delay at stop: (Omron L7/L1000 12x0.1=1.2sec)

12 99 (def.) TSN = Return to parking floor time (from 0 to 99 x 10 sec)

13 1 99 = Holding Connection to Battery During power failure


1 = Disconnection from Battery after 1 minute of power failure

14 99 (def.) RU output used for main contactors control (via FS3/CPF)

15 98 CPF output used for intermediate speed control

17 3 RITING = Direction reversion delay (3x0.1=1.5sec.)

19 68 4 = Maximum number of calls to parallel inputs = 6


20 = Maximum number of calls to parallel inputs = 8
68 = Maximum number of calls to parallel inputs = 24

20 7 Cabin and UP/DOWN floor calls on to parallel inputs

21 0 (def.) 0 = A3 Emendament disabled


1 = Brakes control for A3 Emendament type ELEC/1 or ELEC/1R
7 = Speed regulator control for A3 Emendament type ELEC/L

22 3 3 = Electric lift type with automatic or semiautomatic doors


2 = Electric lift type with manual doors

23 3 1 = Opened doors parking + Powered operator during travel


3 = Closed doors parking + Powered operator during travel (for manual doors = 3)

24 0 Down Re-phasing + 2 speed lift type

25 2 Automatic re-phasing

26 2 Inspection in high speed (reduced by VVVF) with stop on the re-phase impulsors
27 0 (def.) 0 = Fixed Confirmation Control and Directions signalling

28 3 2 = Normal selector + Re-levelling disabled


3 = Reverse selector + Re-levelling disabled
0 = Normal selector + Re-levelling enabled with safety circuit control on AUX3 input
1 = Reverse selector + Re-levelling enabled with safety circuit control on AUX3 input

29 0 Running direction control disabled

30 0 2 = 30KG floor contact (CCO) disabled + full load contact (CCC) enabled
0 = 30KG floor contact (CCO) enabled + full load contact (CCC) enabled

34 32 Registered lift type

35 0 (def.) 0 = Serial connection disabled


1 = Cabin and floor serial displays enabled

36 17 Floors number

83 32 (def.) 32 = Return to parking floor disabled


N = Stop number of the return to parking floor (from 0 to 31)

84 32 (def.) 32 = Emergency descending disabled


33 = Emergency descending with stop at the nearest floor

90 0,1,2 Triplex address with MCU (A=Master)

94 16 16 = Safety circuit control on CS1 input disabled


17 = Safety circuit control on CS1 input disabled + Second access enabled

95 36 Gong at stop and standard UP/DOWN registration

96 4 0 = Reversed binary display outputs (DEC 16)


4 = Normal binary display outputs
8 = 7 segments display outputs instead of normal position outputs