Mu01 - Ahmed Mulla - Lightingtape Layout Ground Floor - Rev003 - 23.04.20
Mu01 - Ahmed Mulla - Lightingtape Layout Ground Floor - Rev003 - 23.04.20
LAUNDRY
EN SUITE 1 2. LED SKIRTINGS
3. UNDER COUNTER LED'S/BIC'S
4. VANITIES & MIRRORS
AC UNIT
5. SHOWER RECESSES
BEDROOM 1
RA
POINT TO
LIGHT WELL 3W-8L
ILLUMINATED
SKIRTING CONSTANT FEED
FOR SENSOR BIC LIGHTING
POSITION FOR
TOUCH SCREEN
3W-12L
DINING AREA STUDY GUEST TOILET BIC LIGHTING
RA
CONSTANT FEED
FOR SENSOR BIC SA
2W-6L LIGHTING
SA
ENTRANCE POINT TO
AC UNIT ILLUMINATED
3W-8L POINT TO
ILLUMINATED
SKIRTING
REVISION SPECIFICATIONS
SKIRTING
POSITION FOR
TOUCH SCREEN
SENSOR FOR
SA LOW LEVEL
BEDROOM 2 CONSTANT FEED LIGHTING IN SENSOR SENSOR
SENSOR FOR
SENSOR
FOR LOW
FOR SENSOR BIC LIGHTING
S
DRESSING
ROOM
S FOR
LIGHTING
FOR
LIGHTING
S CLIENT DETAILS
1W-5L LIGHTING S MAIN EN SUITE S RA
LEVEL AC UNIT
UNDER UNDER
EN SUITE LIGHTING IN GREEN CIRCUIT FOR LED SKIRTING
IN EN SUITE
BED BED
S EN SUITE
LINEAR & SKIRTING UNDER BIC'S SHOULD BE ON
SENSORS ONLY AND NOT HAVE A
PROVISION FOR
CCTV POINT
LIGHTING
SWITCHED LEVER MAIN BEDROOM AHMED MULLA
C SA
DRESSING ROOM & MAIN EN SUITE SENSOR FOR POINTS TO
STUDY LIGHTING S SENSOR FOR LOW GO BACK TO
UNDER BED LEVEL LIGHTING IN
TOILET
LIGHT
SWITCH
S SA CONTACT
SENSOR FOR LOW LEVEL LIGHTING IN DRESSING ROOM CONSTANT FEED
CONSTANT FEED TEL/MOBILE:
FOR SENSOR BIC S CONSTANT FEED
FOR SENSOR BIC
LIGHTING
LIGHTING LINEAR & SKIRTING
FOR SENSOR BIC SA LIGHTING
LIGHTING PROJECT UNIT 201 | BLOCK A | NONOTI PLACE,
SKIRTING LIGHTING ADDRESS: BEREA, DURBAN
PLEASE NOTE THAT ALL BEDROOM
ORANGE CIRCUIT FOR FOOT LIGHT
SHOULD BE ON A SENSOR ONLY AND
GREEN CIRCUIT FOR FOOTLIGHT
SHOULD BE ON SENSORS ONLY
DRESSING ROOM CIRCUITS SHOULD BE SWITCHED
FROM BOTH PEDESTALS AS WELL - 3 PROJECT TITLE:
NOT HAVE A SWITCHED LEVER AND NOT HAVE A SWITCHED ORANGE POINTS FOR SWITCHED
WAY
PLEASE NOTE THAT ALL BEDROOM LEVER LED SKIRTING UNDER SIDE BIC'S
CIRCUITS SHOULD BE SWITCHED AND VERTICAL LINEAR LIGHTS
GREEN CIRCUIT FOR TAPE LIGHT
FROM BOTH PEDESTALS AS WELL - 3 SHOULD EXIT AT FLOOR LEVEL AND
UNDER BED SHOULD BE ON
RENOVATIONS TO EXISTING RESIDENCE
WAY RUN BELOW BIC CARCASSES TO
SENSORS ONLY AND NOT HAVE A
FINAL POSITION - FINAL POSITIONS
SWITCHED LEVER
GREEN CIRCUIT FOR TAPE LIGHT FOR LINEAR LIGHTING ON BIC PLAN
UNDER BED SHOULD BE ON
BEDROOM 1 & EN SUITE 1 SENSORS ONLY AND NOT HAVE A
SWITCHED LEVER
DRAWING DETAILS
DRAWING TITLE:
BEDROOM 1 CEILING INSPIRATION DOUBLE VOLUME & LOUNGE CEILING MAIN BEDROOM, DRESSING ROOM & BEDROOM 2 CEILING INSPIRATION GUEST TOILET CEILING DINING AREA & KITCHEN INSPIRATION
INSPIRATION BATHROOM CEILING INSPIRATION INSPIRATION