5W Ultra-Compact Power Module HLK-5M05 230V AC To 5V/5W DC

The HLK-5M05 is a 5W ultra-compact power module that converts 230V AC input to a 5V/5W DC output. It has a small and thin design, meets various safety certifications, and provides protections such as overload, short circuit, and low/high voltage efficiency. The module operates from -20°C to 60°C with high reliability, meeting EMC and safety test standards.

Uploaded by

sakshi patil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
264 views

5W Ultra-Compact Power Module HLK-5M05 230V AC To 5V/5W DC

The HLK-5M05 is a 5W ultra-compact power module that converts 230V AC input to a 5V/5W DC output. It has a small and thin design, meets various safety certifications, and provides protections such as overload, short circuit, and low/high voltage efficiency. The module operates from -20°C to 60°C with high reliability, meeting EMC and safety test standards.

Uploaded by

sakshi patil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

HLK-5M05 Power module

5W Ultra-compact Power Module HLK-5M05 230V AC to 5V/5W DC

Description:
1. Product features:
 Meet UL, CE requirements,
 Ultra-thin, ultra-small
 All voltage input (AC: 90 ~ 264V)
 Low ripple and low noise
 Output overload and short circuit protection.
 High efficiency, high power density.
 The product is designed to meet the requirements of EMC and Safety Test
 Low power consumption, environmental protection, no-load loss <0.1W

2. Environment Condition

Item Name Technical Criteria Unit


Operation
-20 to +60 ℃
Temperature
Store Temperature -40 to+80 ℃
Relative humidity 5 to 95 %

Cooling way Cooling by radiation


Atmospheric
80 to 106 Kpa
pressure
Sea level elevation ≤2000 m
Vibration coefficient 10~500Hz,
Vibration
2G10min./1cycle, 60min.each along X,Y,Z axes
3. Electrical Characteristic

1. Input characteristics (test at room temperature 20 ℃).

Item Name Technical Criteria Unit


Rated input voltage 100 - 240 VAc
Input voltage range 90 - 264 VAc
Maximum input current ≤0.2 A
Input current surge ≤10 A
maximum input voltage ≤270 VAc
Enter slow start ≤50 mS
Input Low Voltage Vin=110VAc,Output full-load≥69 %
Efficiency
Input High Voltage Vin=220VAc,output full-load≥70 %
Efficiency
Long-term reliability MTBF≥100,000 h

2. Output Characteristics( 5V/1000mA) Apply to Type: HLK-5M05

Item Name Technical Criteria Unit


Load rated output voltage +5 ±0.1 VDc
Full rated output voltage +5 ±0.2 VDc
Short-term maximum ≥1200 mA
output current
The maximum output ≥1000 mA
current for a long time
Voltage Regulation ±0.2 %
Load Regulation ±0.5 %
Output ripple and noise ≤70 mV
(mVp-p) Rated input voltage, full load. Using 20MHz of bandwidth,
The load side 10uF and 0.1uF capacitor to be tested.
Switch overshoot (Rated input voltage and output load plus 10%)≤5 %VO
amplitude
Output over-current 150-200% of the output maximum load A
protection
Output short circuit Direct short circuit at the normal output, automatically
protection resume normal operation after a short circuit removal
Safety Characteristics:

Products designed to meet UL, CE safety certification requirements.

 Safety and electromagnetic compatibility

o Designed with the input of 0.5A UL certified insurance;

o PCB board using double-sided copper clad plate production, material for the 94-
V0 fire rating level;

o Safety standards: Compliance with UL1012, EN60950, UL60950

o Insulation voltage: I / P-O / P: 2500VAC

o Insulation resistance :I / PO / P> 100M Ohms / 500VDC 25 ℃70% RH

o Conduction and radiation :comply with EN55011, EN55022 (CISPR22)

o Electrostatic discharge :IEC / EN 61000-4-2 level 4 8kV / 15kV

o RF radiation Immunity: IEC / EN 61000-4-3 See Application Note

 Temperature safety design

o At room temperature, the capacitors of this power , the inner surface of the main
converter maximum temperature does not exceed 90 ℃;

o Shell maximum surface temperature does not exceed 60 ℃