Testing The Starter On The Engine (1453,1450,1401)

This document provides a procedure for testing a vehicle's starter system when the engine is cranking slowly or not at all. The procedure involves: 1. Checking the battery voltage to ensure it meets the minimum specifications for cranking. Low voltage may indicate battery issues. 2. Measuring starter motor voltage to check for excessive voltage drops between the battery and starter, which could be caused by loose or corroded connections. 3. Inspecting individual components like switches, relays, and cables for problems if voltage drops are observed. 4. Determining if the engine is locked up or experiencing other mechanical issues preventing cranking before replacing the starter.

Uploaded by

Cristopher Laos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
210 views

Testing The Starter On The Engine (1453,1450,1401)

This document provides a procedure for testing a vehicle's starter system when the engine is cranking slowly or not at all. The procedure involves: 1. Checking the battery voltage to ensure it meets the minimum specifications for cranking. Low voltage may indicate battery issues. 2. Measuring starter motor voltage to check for excessive voltage drops between the battery and starter, which could be caused by loose or corroded connections. 3. Inspecting individual components like switches, relays, and cables for problems if voltage drops are observed. 4. Determining if the engine is locked up or experiencing other mechanical issues preventing cranking before replacing the starter.

Uploaded by

Cristopher Laos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

!

Testing The Starter On The Engine{1453,1450,1401}


SMCS - 1401; 1450; 1453

Reference: This article replaces the article with the same title on Page 12 of the May 4, 1987 Service Magazine.

Reference: Service Magazine; May 4, 1987; Page 10; "Alternator/Generator Output Test On The Engine."

Service Magazine; December 10, 1984; "Starters That Remain Engaged After Engine Is Running."

Service Magazine; April 24, 1989; "Page 1; "Causes And Effects Of Low Battery Voltage On Electric Starters."

Reference: Special Instruction, SEHS7768, "Use of 6V2150 Starting/Charging Analyzer Group."

This is a general procedure to help aid the serviceman determine if a starter needs replacement. It is NOT intended to cover all possible
problems and conditions, but to serve only as a guide. The most common 24V circuit is discussed and 12V circuits are indicated as
applicable. On engines with a diagnostic connector, the 6V2150 Starting/Charging Analyzer Group helps you to do the following
procedure in seconds.

General Information
Starting systems usually have four major components:

...Start switch
...Start relay
...Starter solenoid
...Starter motor
Illustration 1. Typical cranking circuit.

The only exception to this typical cranking circuit is that some small engines do not require the start relay. In this case, the start switch is
connected directly to the starter solenoid.

Start switches are relatively low current devices. They are rated to switch approximately 5 to 20 amps. Because the coil of a start relay
between TP2 (Test Point 2) and TP1 in Illustration 1 draws about 1 amp, the start switch can easily turn on the start relay and have long
life.

The switch contacts of a typical start relay are rated to switch between 100 and 300 amps. Because a starter solenoid requires only 5 to
50 amps, the start relay can easily switch this load.

The starter solenoid has two functions: it engages the pinion with the flywheel, and it is a high current switch rated about 1000 amps that
actually turns on the starting motor.

The starter solenoid has two coils: the pull-in coil (W) draws about 40 amps and hold-in coil (X) requires about 5 amps. The instant the
start relay closes, both coils (W and X) receive power. Battery voltage is applied to the high end of both coils, at Test Point (3) which is
the "start" terminal (S). The low end of hold-in coil (X) is permanently connected to the ground post of the starter motor. Grounding for
the low end, Test Point (4), of pull-in coil (W) is momentary, and takes place through the DC resistance of the starter motor. When
magnetic force builds in both coils, the starter pinion is moved to engage the ring gear. Only then will the solenoid contacts close to
power the starter motor. This temporarily removes the ground from pull-in coil (W), and puts battery voltage on both ends of it while the
motor cranks. During this period, the pull-in coil is out of the circuit and draws no current. Cranking continues until power to the motor
solenoid is turned off by the start switch.

The result of these switches and relays is to permit a 5 amp dash-mounted switch to turn on a 500 to 1000 amp motor for cranking an
engine.

Battery voltage (power) available during cranking depends on the temperature of the batteries. See Chart A. This chart is only a GUIDE
as to what to expect from a NORMAL system.

Chart B shows maximum allowable voltage drops in the high current battery circuit to the starter. These values are maximums for
engines with more than about 2000 SMH. Newer engines have less voltage drops.
Voltage drops greater than those listed are usually caused by loose and/or corroded connections or bad switch contacts.

The entire diagnostic procedure can be reduced to:

...confirming that batteries are within specifications


...switches and cables/wiring from the batteries to the starter are not causing too much voltage loss.

The flow chart in Illustration 2 shows the entire procedure.

NOTE: If the engine is equipped with the diagnostic connector, the 6V2150 Analyzer Group can quickly be used in place of this entire
procedure.
Illustration 2. Diagnostic flow chart for checking causes of starter problems with starter installed.

Testing The Starter


Testing Equipment Required:

6V7070 Digital Multimeter (or 6V7800 or 6V3030 or equivalent)

8T0900 Clamp-on Ammeter (optional)

NOTE: This procedure covers a problem where the starter cranks either sluggishly (unusually slow) or not at all.

Test A. Check battery voltage at the battery posts while cranking, or attempting to crank.

NOTE: Use the posts representing 12 or 24 Volts. Do not check voltage on the cable post clamps.

1. Is voltage equal to or greater than what is shown in Chart A?

... Yes - Go to Test B.

...- No Voltage at batteries is too low. Test batteries per Special Instruction SEHS7633.

NOTE: Low batteries can be caused by the battery condition or a shorted starter.

... Optional: Check for shorted starter with 8T0900 Clamp-on Ammeter. (If voltage at battery post is within approximately two volts of
the lowest value in the applicable temperature range of Chart A, and if larger starter cables get hot, this suggests a shorted starter
without using an 8T0900 Ammeter).

NOTE: Chart C lists the maximum current draw for different families of engines.
Test B. Measure starter motor voltage from TP4 to TP5 while cranking, or attempting to crank.

1. Is voltage equal to or greater than that shown in Chart A?

... Yes - Batteries and starter cables down to motor are electrically within specifications. Go to Test C.

... No - Voltage drop (loss) between batteries and starter is too great. Go to next step.

... Optional: Check for shorted starter with 8T0900 Clamp-on Ammeter. (If voltage at battery post is within about two Volts of the
lowest value in Chart A, large starter cables will get hot and confirm a shorted starter without using an 8T0900 Ammeter). Go to next
step.

2. Measure voltage drops in cranking circuit per Chart B. Are all voltages within specifications?

... Yes - Check engine. Go to Test C.

... No - Repair and/or replace faulty electrical component.

Test C. "Bar over" the engine to be sure it is not locked up. Check engine oil viscosity (weight), parasitic
loads, etc.

1. Is engine locked up and/or hard to turn?

... Yes - Repair engine as required.

... No - Go to next step.

2. Does starter crank? (Probably acts sluggish.)

... Yes - Replace starter.

... No - Listen for butt engagement (a clicking sound caused by the pinion hitting, but not engaging the ring gear). If this occurs, turn off
the key switch. Then turn the switch back to crank, and most likely the pinion will engage the ring gear and crank the engine.

NOTE: Butt engagement and open starter solenoid contacts give the same electrical readings. That is, the solenoid is activated, but the
solenoid contacts can not close to turn on the starting motor because the pinion has struck the edge of the ring gear. If a butt engagement
has occurred, the engine will crank on the second attempt 90% of the time.

3. Has butt engagement occurred?

... Yes - Attempt to crank again.


... No - Replace starter.

' (
) *+
*+ ,%-

! " #$ % % &