FortiAnalyzer 200F Supplement
FortiAnalyzer 200F Supplement
Information
Box Includes
FortiAnalyzer 200F
FortiAnalyzer 200F
Information
Console Cable
2 Rack-Mount Brackets
Rack Installation
The FortiAnalyzer unit can be mounted in any standard 19 inch rack unit with the
provided rack-mount brackets and screws.
To avoid personal injury or damage to the unit, it is recommended that two or more
people install the unit into the rack.
6. Plug the provided power cable into the rear of the unit, and then into a grounded
electrical outlet or a separate power source such as an uninterruptible power supply
(UPS) or a power distribution unit (PDU).
Desktop Installation
The FortiAnalyzer unit can be placed on any flat surface with the provided rubber feet.
1. Ensure that the surface onto which the FortiAnalyzer unit to be installed is clean,
level, and stable and that there is at least 1.5in (3.8cm) of clearance on all sides to
allow for adequate airflow.
2. Attach the provided rubber feet to the bottom of the FortiAnalyzer unit.
4. Verify that the spacing around the FortiAnalyzer unit conforms to requirements and
that the unit is level.
1.5in
1.5in
5. Plug the provided power cable into the rear of the unit, and then into a grounded
electrical outlet or a separate power source such as an uninterruptible power supply
(UPS) or a power distribution unit (PDU).
FortiAnalyzer 200F
Status
Flashing Green: Booting up
Alarm
Red: The unit has a major alarm
Amber: The unit has a minor alarm
Off: The unit is operating normally
Power
Green: The unit is on
Off: The unit is off
FortiAnalyzer 200F
Fault
Amber: Main output or fan error
Flashing Amber: Power supply warning event
Off: No errors or no power
Power
Green: Power supply providing power
Flashing Green: Power supply not providing power
Off: Error or no power
FortiAnalyzer 200F
USB (USB A)
USB 3.0 server ports
FortiAnalyzer 200F
Power
100-240V AC, 6A, 50/60Hz
RPS
Optional redundant power
supply connection
12V DC @ 16.5A
Cautions and Warnings Regulatory Compliance
Ambient operating temperature: 0C to 40C This device complies with Part 15 of FCC Rules. Operation is subject to the following
two conditions:
Rack Mount Instructions - The following or similar rack-mount instructions are included (1) this device may not cause harmful interference, and
with the installation instructions: (2) this device must accept any interference received; including interference that may
cause undesired operation.
Instructions de montage en rack - Les instructions de montage en rack suivantes ou
similaires sont incluses avec les instructions d’installation: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the op- reasonable protection against harmful interference when the equipment is operated in a
erating ambient temperature of the rack environment may be greater than room ambient. commercial environment. This equipment generates, uses, and can radiate radio frequen-
Therefore, consideration should be given to installing the equipment in an environment cy energy, and if it is not installed and used in accordance with the instruction manual, it
compatible with the maximum ambient temperature (Tma) specified by the manufacturer. may cause harmful interference to radio communications. Operation of this equipment
Température ambiante élevée – S’il est installé dans un rack fermé ou à unités multiples, la in a residential area is likely to cause harmful interference, in which case the user will be
température ambiante de fonctionnement de l’environnement du rack peut être supérieure required to correct the interference at his own expense.
à la température ambiante de la pièce. Par conséquent, il est important d’installer le
matériel dans un environnement respectant la température ambiante maximale (Tma) WARNING: Any changes or modifications to this product not expressly approved by the
stipulée par le fabricant. party responsible for compliance could void the user’s authority to operate the equipment.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount Industry Canada Equipment Standard for Digital Equipment (ICES)
of air flow required for safe operation of the equipment is not compromised. – Canada
Ventilation réduite – Installation de l’équipement dans un rack doit être telle que la quantité
de flux d’air nécessaire au bon fonctionnement de l’équipement n’est pas compromise. CAN ICES-3 (A) / NMB-3 (A)
Mechanical Loading - Mounting of the equipment in the rack should be such that a This digital apparatus does not exceed the Class A limits for radio noise emissions from
hazardous condition is not achieved due to uneven mechanical loading. digital apparatus set out in the Radio Interference Regulations of the Canadian Department
Chargement Mécanique – Montage de l’équipement dans le rack doit être telle qu’une of Communications.
situation dangereuse n’est pas lié à un chargement mécanique inégal.
Cet appareil numérique n’émet pas de bruits radioélectriques dépassant les limites
Circuit Overloading - Consideration should be given to the connection of the equipment to applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le
the supply circuit and the effect that overloading of the circuits might have on overcurrent brouillage radioélectrique édicte par le ministère des Communications du Canada.
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
European Conformity (CE) - EU
Surtension – Il convient de prendre l’ensemble des précautions nécessaires lors du
branchement de l’équipement au circuit d’alimentation et être particulièrement attentif aux
This is a Class A product. In a domestic environment, this product may cause radio inter-
effets de la suralimentation sur le dispositif assurant une protection contre les courts-cir-
ference, in which case the user may be required to take adequate measures.
cuits et le câblage. Ainsi, il est recommandé de tenir compte du numéro d’identification
de l’équipement.
Moving parts — Hazardous moving parts. Keep away from moving fan blades. 這是甲類的資訊產品,在居住的環境中使用時,可能會造成射頻干擾,在這種情況下,使
Pièces mobiles – Pièces mobiles dangereuses. Se tenir éloigné des lames mobiles du 用者會被要求採取某些適當的對策。
ventilateur.
The presence conditions of the restricted substance (BSMI RoHS table) are available at
Warning: Equipment intended for installation in Restricted Access Location. the link below:
Avertissement: Le matériel est conçu pour être installé dans un endroit où l’accès est https://www.fortinet.com/bsmi
restreint.
China
Battery – Risk of explosion if the battery is replaced by an incorrect type. Do not dispose
of batteries in a fire. They may explode. Dispose of used batteries according to your local 此为A级产品,在生活环境中,该产品可能会造成无线电干扰。这种情况下,可能需要用
regulations. IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries. 户对其采取切实可行的措施。
Batterie – Risque d’explosion si la batterie est remplacée par un type incorrect. Ne jetez
pas les batteries au feu. Ils peuvent exploser. Jetez les piles usagées conformément aux
réglementations locales. IMPORTANT: Suisse: l’annexe 4.10 de SR814.013 s’appliquent
aux batteries.
警告
本電池如果更換不正確會有爆炸的危險
請依製造商說明書處理用過之電池