User'S Manual: Air-Conditioner
User'S Manual: Air-Conditioner
USER’S MANUAL
AIR-CONDITIONER USER’S MANUAL ENGLISH
AIR-CONDITIONER
ANWENDERHANDBUCH DEUTSCH
KLIMAGERÄT
SRK20ZSX-S
ISTRUZIONI PER L’USO ITALIANO
CONDIZIONATORE D’ARIA
SRK25ZSX-S
SRK35ZSX-S
SRK50ZSX-S MANUAL DEL PROPIETARIO ESPAÑOL
SRK60ZSX-S ACONDICIONADOR DE AIRE
GEBRUIKERSHANDLEIDING NEDERLANDS
AIRCONDITIONING
RLF012A201
201610
Your air-conditioner is marked with this symbol. It means that waste electrical and
electronic equipment (WEEE as in directive 2012/19/EU) should not be mixed with
general household waste. Air-conditioner should be treated at an authorized treat-
ment facility for re-use, recycling and recovery and not be disposed of in the munici-
pal waste stream. Please contact the installer or local authority for more information.
contents
Safety precautions ..........................................2 OFF TIMER operation ..................................17
Tips for effective operation .............................5 ON TIMER operation ....................................18
Name of each part and its function.................6 SLEEP TIMER + ON TIMER operation ........18
Remote control ...............................................8 ON TIMER + OFF TIMER operation ............19
Operation failure with the remote control ........8 ALLERGEN CLEAR operation .....................19
Temporary run operation ................................8 WEEKLY TIMER operation ..........................20
Installing two air-conditioners HIGH POWER/ECO operation .....................24
in the same room ............................................9 NIGHT SETBACK operation .........................25
Child lock ........................................................9 SILENT operation .........................................25
Airflow range setting .....................................10 MENU function
Operation and display section Display brightness adjustment ...................26
for remote control .........................................12 AUTO OFF operation .................................27
Current time setting .....................................13 SELF CLEAN operation .............................28
AUTO mode operation ..................................13 PRESET operation ....................................28
Temperature adjustment during AUTO mode...14 Maintenance .................................................29
FAN SPEED .................................................14 Proper installation .........................................31
COOL/HEAT/DRY/FAN mode operation .......15 Troubleshooting ...........................................31
Air-conditioner operation temperature range ....15 Notice ...........................................................32
Characteristics of HEAT mode operation......15 Contact your dealer ......................................33
Airflow direction adjustment..........................16 Auto restart function .....................................33
3D AUTO operation ......................................16 About the multiple air-conditioners ...............33
SLEEP TIMER operation ..............................17 Self diagnosis function..................................34
–1–
Please observe these precautions with great care, since they are essential to your safety.
• Symbols which appear frequently in the text have the following meaning:
❚ INSTALLATION PRECAUTIONS
WARNING
• The system is for domestic and residential use.
If used in severe environments, such as an engineering workplace, the equipment may
function poorly.
• The system must be installed by your dealer or a qualified installer.
It is not advisable to install the system by yourself, as faulty handling may cause
leakage of water, electric shock or fire.
CAUTION
• Do not install it where flammable gas may leak.
Gas leaks may cause fire.
• Make sure that an earth leakage • Make sure to install the drain hose
breaker is installed. properly so that all the water is drained
If you do not install an earth leakage out.
breaker, you may get an electric shock. Improper installation may lead to water
drop in the room resulting in wet furniture.
• Make sure that the system has been properly earthed.
Earth wire should never be connected to a gas pipe, water pipe, lightning conductor
or telephone earth wire. Improper installation of the earth wire may cause an electric
shock.
–2–
❚ OPERATION PRECAUTIONS
WARNING
• Children shall not play with the • Cleaning and user maintenance shall
air-conditioner. not be made by children without
• Do not expose yourself to the cooling supervision.
air for a long period. • Do not insert anything into the air
This could affect your physical condition outlet.
and cause health problems. This may cause injury, as the internal fan
rotates at high speed.
• This air-conditioner can be used by children aged from 8 years and above
and people with reduced physical, sensory or mental capabilities or lack of
experience and knowledge, if they have been given supervision or instruction
concerning use of the air-conditioner in a safe way and understand the hazards
involved.
• Store the remote control out of reach of children.
Failure to observe this may result in the batteries being swallowed or other accidents.
CAUTION
• Only use approved fuses. • Do not use for preservation of food,
Use of steel or copper wire instead of an plants or animals, precision devices or
approved fuse is strictly prohibited, as it works of art.
may cause a breakdown or fire. The system is only intended for use in
• Do not handle the switches with wet ordinary domestic rooms. Any other use
hands. of the system may damage the quality of
This may cause an electric shock. food, etc.
• Do not swing from the indoor unit. • Do not place anything containing
If the indoor unit falls down,you may get water, like vases, on top of the unit.
injured. Water entering the unit could damage the
• Do not place a flammable insecticide insulation and therefore cause an electric
or paint spray near the air-conditioner, shock.
nor spray it directly on the system. • Do not install the air-conditioner where
This may result in a fire. the airflow direction is aimed directly at
• Do not expose any combustion plants or animals.
appliance directly to the air stream of This will damage their health.
the air-conditioner. • Do not sit on the outdoor unit nor put
The combustion appliance may anything on it.
malfunction. If the unit falls down or things drop from it,
• Do not wash the air-conditioner with people could get hurt.
water. • After a long period of use, check the
This could cause an electric shock. unit’s support structure regularly.
Using a high pressure washer may cause If you do not repair any damage right
damage to the aluminum fins, resulting in away, the unit may fall down and cause
performance decrement. personal injury.
–3–
CAUTION
• Do not touch the aluminum fins on the • Do not shut off the power source
heat exchanger. immediately after stopping the
It may result in injury. operation.
• Do not place household electrical Wait at least 5 minutes, otherwise there is
appliances or household items under- a risk of water leakage or breakdown.
neath the indoor or outdoor units. • Do not control the system with main
Condensation falling from the unit may power switch.
stain objects and cause accidents or It can cause fire or water leakage. In
electrical shock. addition, the fan can start unexpectedly,
• Do not operate the system without the which can cause personal injury.
air filter. • Do not pour liquid into the unit and do
It can cause malfunction of the system not put water container on the unit.
due to clogging of the heat exchanger. Water entering the unit could damage the
insulation and therefore cause an electric
shock.
• If you operate air-conditioner together • Contact your dealer to clean inside the
with a combustion appliance, you must indoor unit, do not attempt to do by
regularly ventilate the indoor air. yourself.
Insufficient ventilation may cause The use of a non-approved detergent or
accidents due to oxygen deficiency. improper washing method may damage
• Stand firmly on a stepladder or other the unit’s plastic components and cause
stable object when removing the inlet leaks. Damage, smoke, or fire may also
panel and filters. happen if the detergent comes in contact
Failure to observe this may result in injury with electrical parts or the unit’s motor.
through insecure objects toppling over. • Stop the unit and turn off the power if
• When you clean air-conditioner, stop you hear thunder or there is a danger
the unit and turn off the power source. of lightning.
Never open the panel while the internal It may damage the unit.
fan is rotating. • If the power cable becomes damaged,
• Do not place objects near the outdoor contact your dealer or a qualified
unit or allow leaves to gather around installer.
the unit. If it is not replaced, it may cause a
If there are objects or leaves around the breakdown or fire.
outdoor unit, small animals may enter
unit and contact electrical parts and may
cause a break-down, smoke or fire.
–4–
–5–
Air filters
Page 29
• Photocatalytic washable
Fan deodorizing filter (Orange)
• Inside of
the unit
Flaps
(Horizontal blades)
• Up / down airflow
direction adjustment Model name
OUTDOOR UNIT
WARNING CAUTION
Air inlet
(back and side) MOVING FAN BLADES SHARP EDGE OF FINS
DO NOT INSERT ANYTHING DO NOT TOUCH THE
DO NOT STEP ON TOP OF THIS UNIT.
INTO THE AIR OUTLET. ALUMINUM FINS.
IT MIGHT CAUSE INJURY. IT MIGHT CAUSE INJURY. IT MIGHT CAUSE INJURY.
Model name
Refrigerant pipe
Fan and electric wire
• Inside of the unit Don't touch
Drain hose
the terminal
block.
Don't touch
refrigerant
Model name label pipings and
(SRC50~60ZSX-S) connections.
–6–
Page 28
• RUN lights blink quickly during invalid operation mode. • Blinks when airflow is stopped to
Page 33 prevent blowing out of cold air in
heating operation. (1.5 seconds ON,
0.5 seconds OFF)
Page 32
Accessories
CAUTION
• Do not touch the air inlet panel and flap while it is operating.
- The air inlet panel opens up while the system is operating.
Do not install the unit in a fashion in which the air inlet panel cannot open or place
objects near the indoor unit.
- The air inlet panel and the flap close when the operation stops.
Your fingers may get caught when the panel or the flap closes.
• Do not apply excessive force to the air inlet panel and flap. Doing so may cause
these parts to malfunction.
NOTE
Pip Pip Pip Pip Pip Pip Pip Pip Pip Pip Pip Pip
–7–
1 Pull out the cover. • Do not use old and new batteries together.
• Remove the batteries when the remote control is not used for a long period.
• The recommended effective period of a battery conforming to JIS or IEC
2 Insert new batteries.
R03 (AAA, Micro) x2
should be 6 to 12 months with normal use. If used longer, or when an
unspecified battery is used, liquid may leak from the battery, causing the
Pay attention to remote control to malfunction.
the and • The recommendable effective period is printed on the battery. This may be
marks shorter due to manufacturing time to the unit. However, the battery may still
be in working order after expiry of its nominal life.
■ When the display shows any abnormal condition, press the ACL switch with the
tip of a ballpoint pen.
The following cases show exhausted batteries. Replace old batteries with new ones.
• Receiving beep is not emitted when a signal is transmitted.
• Display fades away.
• Do not put any obstructing • Do not spill any liquid on the • Do not place heavy objects on the
obstacles between the remote remote control. remote control, or step on it.
control and the unit.
NOTE
• Do not keep pressing the unit ON/OFF button down for 5 seconds or more.
(Pressing it 5 seconds or more sets the forced cooling operation used during servicing or when relocating the air-conditioner.)
–8–
Disconnect
3 Insert batteries.
Close the cover.
3 Check that the reception buzzer sound “peep” is emit-
ted from the indoor unit.
At completion of the setting, the indoor unit emits a buzzer sound
“peep”. (If no reception sound is emitted, start the setting from the
beginning again.)
Child lock
■ This function locks the remote control operation to prevent an operation error.
is displayed. When Child lock is set, only the ON/OFF button can be
operated.
Releasing procedure
Turn off the light by pressing the SET button for 3 seconds or more.
NOTE
• While Child lock is set, the settings of temperature, fan speed and airflow
direction cannot be changed. To change the settings, reset Child lock.
• Child lock will not function during ALLERGEN CLEAR operation.
–9–
NOTE
• Once the airflow range setting is configured, it is stored in the air-conditioner even if the power source is turned off. To change the
airflow range setting, set range again with the remote control.
• During the operation, an airflow range setting cannot be set.
• When the air-conditioner is installed at the location within 50 cm from the wall, it is recommended to change the airflow range setting
to “Right End Installation” or “Left End Installation”.
– 10 –
Motion sensor
orientation
• Depending on the room conditions and/or the installation location, the motion sensor may not be able to detect people correctly.
The motion sensor may not be able to detect people in the following cases:
− When a person(s) is immediately under or beside the air-conditioner
− When the room temperature is 30°C or higher
− When there is any obstacle such as furniture or a glass window between the air-conditioner and the person(s)
− When the person(s) is covering most of their skin with extremely heavy clothes or they are exposing their backs to the air-
conditioner
- When the person(s) makes extremely little movement, which may occur while, for example, they are sleeping
• In the following cases, the motion sensor may judge that there is someone in the room even though there is actually not:
− When there is an animal such as a dog or cat in the room
− When plant leaves are swaying in the wind
− When a heating appliance (e.g., oscillating heater) or other heat-generating object is moving
− When there is a significant temperature change in walls or floors of the room at the time the operation starts
– 11 –
– 12 –
2 Press the “ or
(Set to Sat)
(TIMER)” button.
4 Press the “ or
(Set to 10:30)
(TIMER)” button.
NOTE
• The timer operation works based on the time clock, so set it • When the battery of the remote control is replaced or the ACL
correctly. switch is pressed, the remote control will be set to the initial
• The remote control data will be reset when the present time is state. Since the WEEKLY TIMER program is not set in the initial
set. state, set the program according to the setting procedure.
– 13 –
■ Each time the button is pressed, the switch over occurs in the following order
18 → 19 → ............ 23 → 24 → 25 ......... → 30.
When 30 is indicated, even if the button is pressed, the indicator does not change.
When it is a little hot
■ Each time the button is pressed, the switch over occurs in the following order
30 → 29 → ............ 25 → 24 → 23 ......... → 18.
When 18 is indicated, even if the button is pressed, the indicator does not change.
FAN SPEED
■ The FAN SPEED can be set without DRY mode.
AUTO ULo Lo Me Hi
NOTE
– 14 –
Recommendation
COOL HEAT DRY FAN
26 °C - 28 °C 22 °C - 24 °C 24 °C - 26 °C —
NOTE
• In case air is not blown out, when starting the heating To stop: Press the ON/OFF button.
operation. Page 32
Defrosting
If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents efficient heating.
If this happens, the automatic defrost function is activated and the heating operation stops for 5 to 15 minutes during defrosting.
• Both indoor and outdoor fans stop and the RUN light blinks slowly (1.5 seconds ON, 0.5 seconds OFF) during defrosting.
• The outdoor unit may release some steam during defrosting. This is to help the defrosting process and is not a defect.
• The HEAT operation resumes as soon as defrosting has been completed.
– 15 –
■ Left/right direction can be adjusted with the AIR FLOW L/R (LEFT/RIGHT) button on the remote control. Every time you press this
button, the mode changes as follows:
Change on AIR FLOW (LEFT/RIGHT) mode.
(Louver stopped)
NOTE (Swing)
• The actual position of the flap and louver may differ from the display shown.
• When heating operation starts, the flap and louver direction is fixed at the horizontal / center position in order to avoid cold draft. It
returns to the set position when the warm air supply is started.
• The flap and louver direction will be controlled to the horizontal/center position when the room temperature reaches the set
temperature and compressor stops or when defrosting is in operation.
• The airflow direction cannot be set during the period mentioned above. Change the airflow direction settings after the warm air is
supplied and the flap/louver goes to the set position.
3D AUTO operation
■ Fan speed and airflow direction are automatically controlled, allowing the entire room to be efficiently air-conditioned.
Releasing procedure
Press the 3D AUTO button to turn off the 3D AUTO display.
NOTE
– 16 –
No display
(canceled)
Set to
Changing of set time • The unit stops after the set time lapses.
Set a new time by pressing SLEEP button.
NOTE
How to cancel
• SLEEP operation will not function during ALLERGEN CLEAR operation.
Press the CANCEL button to turn off the SLEEP
• SLEEP TIMER cannot be set simultaneously with OFF TIMER.
display.
3 Press the “ or
Every time the
0:00 0:10 0:20
(TIMER)” button.
button is pressed, the display is switched in the order of:
... 1:00 1:10 (Units of ten minutes)
Every time the button is pressed, the display is switched in the order of:
0:00 23:50 23:40 ... 23:00 22:50 (Units of ten minutes)
Set at 22:30.
NOTE
Changing of set time • The unit stops at the end of the set period of time.
• Make sure to press the button within 60 seconds from the last operation
Set a new time by using the OFF TIMER button. in step 3, otherwise the setting is not completed.
• The current time is not displayed during OFF TIMER operation.
• OFF TIMER operation will not function during ALLERGEN CLEAR
How to cancel operation.
Press the CANCEL button to turn off the timer • Different from SLEEP TIMER operation, automatic set temperature
display. adjustment is not done during OFF TIMER operation.
– 17 –
2 Press the “ or
Every time the
0:00 0:10 0:20
(TIMER)” button.
button is pressed, the display is switched in the order of:
... 1:00 1:10 (Units of ten minutes)
Every time the button is pressed, the display is switched in the order of:
0:00 23:50 23:40 ... 23:00 22:50 (Units of ten minutes)
Set at 8:00.
NOTE
Set to
The setting of the lighting of the timer light (yellow) of this unit is complete.
• After the SLEEP TIMER set time has lapsed, the operation stops, and it starts from
5 to 60 minutes before the ON TIMER’s set time.
• The timer light is turned off when ON TIMER set time comes.
– 18 –
Timer light (yellow) on the unit will light when the setting is completed.
■ The set time will be displayed on the remote control. The display will change
depending on the operational status.
In COOL operation
▼
▼
COOL operation HEAT operation
checked 60 minutes before
(Stop) Operation starts
the ON time. Depending on
the temperature at that time, Set temperature
the operation starts 5 to 60 (Operation) +1.0°C -1.0 °C
minutes before the timer is at -2.0 °C
Set temperature Set temperature -3.0 °C
ON.
• The function is available -1.0°C
for both COOL and HEAT -6.0 °C
operation mode (including Check the room Set time Set time 1 hour 2 hour Set time 30 minutes 1 hour 2 hour
AUTO). It does not work for temp. 1 hour before.
DRY mode.
NOTE
– 19 –
When the WEEKLY TIMER is set to ON, the timer light (yellow) of the
air-conditioner is on.
When the battery of the remote control is replaced or the ACL switch is
pressed, the remote control is set to the initial state. Since the WEEKLY
TIMER program is not set in the initial state, set the program according to the
setting procedure.
NOTE
• The WEEKLY TIMER is switched to ON/OFF regardless of • OFF TIMER operation of the WEEKLY TIMER is effective only
whether the air-conditioner is running or not. when the air-conditioner is running. When the time set by the
• The ON TIMER operation of the WEEKLY TIMER is effective OFF TIMER is reached, the air-conditioner stops.
regardless of whether the air-conditioner is running or not. • When multiple program numbers are set for the current day
When the ON TIMER setting time is reached, the remote (day of the week), the operation is performed from the earliest
control operates according to the contents that are set. The time that is set.
remote control display is also switched to the operation • When various timers (ON TIMER, OFF TIMER, and SLEEP
contents that are set. The setting can be changed from the TIMER) are operating, the WEEKLY TIMER does not operate
remote control after ON TIMER operation of the WEEKLY even if the time set in the ON TIMER or OFF TIMER is
TIMER. reached. The WEEKLY TIMER becomes effective after various
The following contents can be set by the ON TIMER. timers are terminated.
Operation mode, fan speed, temperature, airflow direction, • The ON TIMER or OFF TIMER of the same time in the same
ECO, 3D AUTO, NIGHT SETBACK, SILENT day of the week cannot be set.
Comfort start-up is not performed for WEEKLY TIMER • In case WEEKLY TIMER setting is not sent to the unit, TIMER
ON TIMER operation. light will not turn on even if the WEEKLY button is pressed and
is displayed on the remote control.
– 20 –
Set after setting the current day of the week and the time.
4 Press the “ or
– 21 –
Set a time.
(TIMER)” button.
When ON TIMER is selected, operation mode, fan speed, and airflow direction can be
changed and the ECO, SILENT or NIGHT SETBACK operation can be set.
NOTE
• If no operation is performed for 60 seconds in setting mode, the setting changes that have been made until then become invalid and
the setting mode terminates. Subsequently, and all the program numbers (P1, P2, P3 and P4) blink for 10 seconds.
(This blinking can not be observed if setting mode gets terminated while setting only one program.)
• At the end of the setting mode, point the remote control at the air-conditioner and press the PROGRAM button. In this case, check
that the air-conditioner emits a reception buzzer sound three times (pip, pip, pip). If the buzzer sound is not emitted, set the mode
to the setting mode again by pressing the PROGRAM button and check that the buzzer sound is emitted.
– 22 –
Tue P1 P2 P3 P4
Sun P1 P2 P3 P4
Releasing procedure
The Confirm mode can be terminated by pressing the ON/OFF, CANCEL or
SET button.
NOTE
No display
NOTE
• During the HIGH POWER operation, the room temperature • When the following operations are set, HIGH POWER
is not controlled. When it causes an excessive cooling or operation will be canceled.
heating, press the HI/ECO button again to cancel the HIGH 1 When the HI/ECO button is pressed again.
POWER operation. (The operation mode will be changed to the ECO operation)
• HIGH POWER operation is not available during the DRY and 2 When the operation mode is changed.
ON TIMER + OFF TIMER operations. 3 When it has been 15 minutes since HIGH POWER
• When HIGH POWER operation is set after setting operation has started.
ON TIMER operation, HIGH POWER operation will start from 4 When the 3D AUTO button is pressed.
the set time. 5 When the SILENT button is pressed.
6 When the NIGHT SETBACK button is pressed.
• After HIGH POWER operation, the sound of refrigerant
flowing may be heard. • Not operable while the air-conditioner is OFF.
ECO operation
Pressing the HI/ECO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating.
The remote control displays.
The set temperature will be adjusted according to the amount of movement made by the person(s) the motion sensor has detected.
MODE:AUTO mode operation
Heat Source & Movement Low Normal High None When the extent of human
+3ºC Low
COOL/DRY +2ºC
movement is low
When the extent of human
Set High
temperature movement is high
When there is no one in the
HEAT None
room
-2ºC
-3ºC • The set temperature is automatically
MODE:COOL/HEAT/DRY mode operation adjusted during ECO operation,
however, the indication on the remote
Heat Source & Movement Low Normal High None
control display does not change.
+3ºC
• When the SLEEP TIMER, OFF TIMER,
COOL/DRY
and ON TIMER + OFF TIMER operation
Set are set, the motion sensor does not
temperature adjust temperatures.
HEAT
-3ºC
NOTE
• It will go into ECO operation at the next time the air-conditioner • When the following operations are set, ECO operation will be
runs in the following case. canceled.
1 When the air-conditioner is stopped by ON/OFF button 1 When the HI/ECO button is pressed again.
during ECO operation. 2 When the operation mode is changed from DRY to
2 When the air-conditioner is stopped in SLEEP or OFF FAN.
TIMER operation during ECO operation. 3 When the NIGHT SETBACK button is pressed.
3 When the operation is retrieved from SELF CLEAN • Not operable while the air-conditioner is OFF.
or ALLERGEN CLEAR operation.
– 24 –
No display
(NIGHT SETBACK on) (NIGHT SETBACK off)
Releasing procedure
Press the NIGHT SETBACK button or MODE button to turn off the NIGHT
SETBACK display.
NOTE
SILENT operation
■ When the SILENT operation is set, the unit operates more silently reducing noise from the outdoor unit.
With the air-conditioner turned off, start the operation from Step 1. With the air-conditioner running, start from Step 2.
No display
(SILENT on) (SILENT off)
Releasing procedure
Press the SILENT button to turn off the SILENT display.
NOTE
– 25 –
100% 50% 0%
(Orignal) (Turned off)
– 26 –
( AUTO OFF
off ) ( AUTO OFF
on ) ( AUTO OFF
on )
Stop the operation 2 hours after the sensor judges that there is no
2H
one in the room.
* Default setting
Releasing procedure
In step 2, select AUTO OFF off, and press the SET button. Check that the
AUTO OFF indicator has turned off.
NOTE
• Emits a warning sound, “peep, peep, peep”, and stops the operation
automatically when there is no one in the room for setting time (Standby)
When the motion sensor detects a person 12 hours after the operation
was stopped, the operation resumes with the same settings.
The operation does not resume even if a person is detected after 12
hours has elapsed. (The RUN light blinks slowly during standby.)
• It is recommended that you set the AUTO OFF function to “Off”, if people
who carry out minimal movements, such as an infant or sick person, are
in the room.
(The motion sensor may determine that there is no one in the room, and
stop operation.)
• When the SLEEP TIMER, OFF TIMER and ON TIMER + OFF TIMER
operation are set, the AUTO OFF functions is disabled.
• The AUTO OFF function does not activate if the operation is started by
the ON TIMER when there is no one at home.
• When 12 hours has elapsed after the operation was stopped by the
AUTO OFF function, the operation does not resume even when a person
walks into the room. However, the remote control display indicates
operation.
– 27 –
NOTE
OFF
1 second
PRESET operation
■ This operation can save the preferred setting for future operation.
NOTE
– 28 –
Turn off the power source. Cleaning the air filter Standard interval is once
every two week
• Do not spill any liquid to the
unit.
• Do not touch the aluminum fins
1 Remove the air filter • Pull up the air inlet panel forward.
• Lightly hold the knobs both sides and lift a little
to remove the panel forward.
on the heat exchanger.
• Stand firmly on a stepladder
or other stable object when re-
moving the air inlet panel and
filter. 2 Cleaning If the filter is very dirty, clean it with warm water
(approx. 30°C), and dry it thoroughly.
CAUTION
Do not use the following items: • Do not clean the filters with boiling water.
• Hot water (40°C or more) • Do not dry them over an open flame.
It may deform or discolour the unit. • Pull them out gently.
• Petrol, paint thinner, benzine or
cleanser, etc. I t m ay d e fo r m o r
scratch the unit. 3 Reinstall the air filter
Hold the lower corners of A, then release the Lift up A together with B by holding both of
hook from the main body part. them.
Approx. 80°
4 Clean both the indoor and outdoor units. 4 Turn on the power source.
5 Remove batteries from the remote control. 5 Insert batteries in the remote control.
1. Open the air inlet panel and remove the air filters. Page 29
2. Remove the allergen clear filter (Light orange) from air-conditioner and inspect the
filter. Use a vacuum cleaner to remove any dust or dirt from the allergen clear filter.
Replace the allergen clear filter if it cannot be cleaned or if it has been for about
1 year.
(The allergen clear filter should be replaced after about 1 year of used. However, the
actual replacement period may vary depending on the conditions in which the filter
is used.)
NOTE
Air-cleaning filter
• The allergen clear filter and the photocatalytic washable deodorizing filter
may be installed on either the right or left side of the air-conditioner.
• Install the allergen clear filter with the light orange side on front side.
4. Install the air filters and close the air inlet panel. Page 29
CAUTION
• The heat exchanger may injure your fingers.
• Stand firmly on a stepladder or other stable object when removing the air inlet panel and filters.
– 30 –
Troubleshooting
Please carry out the following checks before making a service call.
If the air-conditioner does not
The air-conditioner does not work at all. operate properly after you have
• Has the power switch been turned off? checked the left points, or if any
• Has the timer been set in the “ON” position? doubt still exists after you have
• Is there a power failure or a blown fuse? consulted page 32, or if things
Poor cooling or heating happen as shown on page 33,
• Have you set the thermostat at a suitable temperature? switch off the power and contact
• Is the air filter clean? (Not clogged?) your dealer.
• Have you left any doors or windows open?
• Is there any direct sunlight entering the room?
• Is there a heat source in the room?
• Are there too many people in the room?
– 31 –
Air is not blown out when starting the HEATING operation. Airflow has stopped to prevent blowing out of cold air until the
RUN light blinks slowly indoor heat exchanger has warmed up. (2 to 5 minutes)
(1.5 seconds ON, 0.5 seconds OFF)
Air is not blown out for 5 to 15 minutes or cool air is When outdoor temperature is low and humidity is high, the
blown out for a moment at HEATING operation. unit sometimes performs defrosting automatically. Please
RUN light blinks slowly wait. During defrosting, water or steam may release from the
(1.5 seconds ON, 0.5 seconds OFF) outdoor unit.
Air is not blown out when starting the DRY operation. The indoor fan may stop to prevent re-evaporation of
dehumidified moisture and to save energy.
(RUN light is on)
Noise
You hear a slight gurgling sound. This is caused by refrigerant moving within the unit.
You hear a slight cracking sound. This is caused by heat expansion or contraction.
You hear a hissing or clicking sound. This is caused by the operation of the refrigerant control
valves or electric components.
Whistling noise is heard from the outdoor unit. This means that the rotation speed of the compressor is
increasing or decreasing.
Sometimes a “Shooooo” sound might come for a short This is the sound when operation of another indoor unit is
time from the unit that is turned off. stopped.
Others
The unit does not restart immediately after you have Restart is blocked for 3 minutes after you have stopped the
stopped it. operation to protect the unit.
(RUN light is on)
The 3 minutes protection timer in the microcomputer
automatically starts it up again.
Some steam releases during COOL operation. This may occur if the room’s temperature and humidity are
very high. It disappears as soon as the temperature and
humidity decrease.
There is a slight smell. Air blown out during operation may smell. This is caused by
tobacco or cosmetics adhering to the unit.
After a power cut, the unit does not restart even if power If the auto restart function is not set, the unit will not restart
has been restored. automatically. Use the remote control to start the operation
again.
Remote control signals are not received. Remote control signals may not be received if the signal
receiver on the air-conditioner is exposed to direct sunlight or
other bright light.
If so, block the sunlight or reduce the other light.
Moisture may form on the air outlet grills. If the unit is operated for a long time in high humidity, moisture
may form on the air outlet grills and start dripping.
Fan will not stop immediately after unit operation is Indoor fan : Fan will not stop after 2 hours if set to SELF
stopped. CLEAN operation.
Outdoor fan : Fan will not stop about a 1 minute period in
order to protect the unit.
RUN light stays on even though operation was stopped. The RUN light illuminates during SELF CLEAN operation.
Run light will turn off when SELF CLEAN operation ends.
– 32 –
NOTE
• Auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs
to be switched off.
• When power failure occurs, the timer setting is canceled. Once power is resumed, set the timer again.
OFF
0.5 seconds
Automatic Operation
• When the remote control operation switch is in the AUTO mode, the air-conditioner automatically selects either COOL or HEAT
mode when operation is started depending on the room temperature.
• During simultaneous operation of air-conditioners, operation modes may be automatically changed in response to the temperatures
of the individual rooms; this will result in the operation of the outdoor unit being stopped. In such a case, COOL or HEAT mode should
be used instead of AUTO mode. (This is only relevant when more than one air-conditioner unit is being used.)
– 33 –
RUN light
Description of trouble Cause
Indoor heat exchanger sensor 1 • Broken heat exchanger sensor 1 wire, poor connector
1-time flash
error connection
2-time flash Room temperature sensor error • Broken room temperature sensor wire, poor connector
connection
Indoor heat exchanger sensor 3 • Broken heat exchanger sensor 3 wire, poor connector
3-time flash
error connection
TIMER light ON
5-time flash Circuit error • Circuit failure or poor connector connection
6-time flash Indoor fan motor error • Defective fan motor, poor connector connection
TIMER light
1-time flash Outdoor temperature sensor error • Broken outdoor sensor wire, poor connector connection
Outdoor heat exchanger sensor • Broken heat exchanger sensor wire, poor connector
2-time flash error connection
RUN light keeps flashing
4-time flash Discharge pipe sensor error • Broken discharge pipe sensor wire, poor connector connection
5-time flash Suction pipe sensor error • Broken suction pipe sensor wire, poor connector connection
RUN light ON
• Gas shortage, defective discharge pipe sensor,
5-time flash Over heat of compressor closed service valve
7-time flash Outdoor fan motor error • Defective fan motor, poor connector connection
Keep flashing Cooling high pressure protection • Overcharge of refrigerant, short circuit of outdoor unit
• Defective compressor
RUN light 2-time flash 2-time flash Rotor lock • Open phase on compressor
• Defective outdoor unit boards
RUN light 7-time flash 1-time flash Closed service valve • Closed service valve
RUN light OFF Keep flashing Indoor air inlet panel open • Indoor air inlet panel open
– 34 –
USER’S MANUAL
AIR-CONDITIONER USER’S MANUAL ENGLISH
AIR-CONDITIONER
ANWENDERHANDBUCH DEUTSCH
KLIMAGERÄT
SRK20ZSX-S
ISTRUZIONI PER L’USO ITALIANO
CONDIZIONATORE D’ARIA
SRK25ZSX-S
SRK35ZSX-S
SRK50ZSX-S MANUAL DEL PROPIETARIO ESPAÑOL
SRK60ZSX-S ACONDICIONADOR DE AIRE
GEBRUIKERSHANDLEIDING NEDERLANDS
AIRCONDITIONING
RLF012A201
201610