EH Series: Single Phase Hybrid Inverter (HV Battery)
EH Series: Single Phase Hybrid Inverter (HV Battery)
AC Output/Input Nominal Apparent Power Output to Utility Grid (VA)*2 3600 5000 6000
Data (On-grid) Max. Apparent Power Output to Utility Grid(VA)*2 3600/3960*1 5000/5500*1 6000/6600*1
Max. Apparent Power from Utility Grid (VA) 7200 (Charging 3.6kw,back-up 10000 (Charging 5kw,back-up 12000 (Charging 6kw,back-up
output3.6kw) output 5kw) output 6kw)
Nominal Output Voltage (V) 230
Nominal Ouput Frequency (Hz) 50/60
Max. AC Current Output to Utility Grid (A)*2 16/18*1 21.7/24*1 26.1/28.7*1
Max. AC Current From Utility Grid (A) 32 43.4 52.2
Output Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDi (@Nominal Output) <3%
Back-up Output Max. Output Apparent Power (VA) 3600 5000 6000
Data (Back-up) Peak Output Apparent Power (VA) 4320 ,60sec 6000 ,60sec 7200 ,60sec
Max. Output Current (A) 15.7 21.7 26.1
Nominal Output Voltage (V) 230 (±2%)
Automatic Switch Time (ms) <10
Nominal Ouput Frequency (Hz) 50/60 (±0.2%)
Output THDv (@Linear Load) <3%
Efficiency PV Max. Efficiency 97.6%
PV Europe Efficiency 97.0%
PV Max. MPPT Efficiency 99.9%
Battery Charged by PV Max. Efficiency 98.0%
Battery Charge/Discharge from/to AC Max. Efficiency 96.6%
Protection Anti-Islanding Protection Integrated
Battery Input Reverse Polarity Protection Integrated
Insulation Resistor Detection Integrated
Residual Current Monitoring Unit Integrated
Output Over Current Protection Integrated
Grid Output Short Protection Integrated
Output Over Voltage Protection Integrated
General Data Operating Temperature Range (°C) -35~60
Relative Humidity 0~95%
Operating Altitude (m) 4000
Cooling Natural Convection
Noise (dB) <35
User Interface LED & APP
Communication with BMS*3 RS485; CAN
Communication with Meter RS485
Communicaiton with Portal Wi-Fi/Ethernet(Optional)
Weight (kg) 17
Size (Width*Height*Depth mm) 354*433*147
Mounting Wall Bracket
Protection Degree IP65
Standby Self-Consumption (W)*4 <10
Topology Battery Non-Isolation
Certifications & VDE-AR-N 4105, G98, G100
Standards*5 Grid Regulation CEI 0-21, AS/NZS4777.2, VDE-AR-N 4105, G99, G100, CEI 0-21, AS/NZS4777.2, NRS097-2-1
NRS097-2-1
Safety Regulation IEC/EN62109-1&-2
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-4-16, EN61000-4-18,
EMC
EN61000-4-29
*1 For CEI 0-21.
*2 The grid feed in power for VDE-AR-N 4105 and NRS097-2-1 is limited 4600VA, for AS/NZS 4777.2 is limited 4950VA & 21.7A.
*3 No back-up output.
*4 CAN communication is configured by default. If 485 communication is used, please replace the corresponding communication line.
*5 Not all certifications & standards listed, check the official website for details.