Vane Pump
for
Open Loop Hydraulic Systems
EN 2.908.1/11.19
EXCLUSION OF LIABILITY
We have made every effort to ensure the accuracy of
the contents of this document.
However, errors cannot be ruled out. Consequently,
we accept no liability for such errors that may exist nor
for any damage or loss whatsoever which may arise
as a result of such errors. The content of this manual
is checked regularly. Any corrections required will
be incorporated in future editions. We welcome any
suggestions for improvements.
All details are subject to technical modifications.
Technical specifications are subject to change without
notice.
EN 2.908.1/11.19
2
Variable Displacement
Vane Pump
for
Open Loop Hydraulic Systems
1. VANE PUMPS
3
1.1 MECHANICAL COMPENSATION PVV102
Geometric Operating pressure Maximum
Displacement Rated pressure drive speed
Series [cm³/rev] [bar] [rpm]
PVV102-05-16 17 120
PVV102-1-20 21
1800
PVV102-1-25 26
PVV102-1-32 33
100
PVV102-2-40 42
PVV102-2-50 51
PVV102-2-63 63
1500
PVV102-3-80 80
PVV102-3-100 100 90
PVV102-3-120 123
3
4
DE 2.908.1/11.19
1.1 VARIABLE DISPLACEMENT,
MECHANICAL COMPENSATION
CONTENTS PVV102
EN 2.908.4.1/11.19
5
ORDERING CODE
1.1.1 Variable Displacement, Mechanical Compensation
PVV102 – 05 – 16 F H R M - XXXX
Variable displacement vane pump
with mechanical compensation
Size
05 1 2 3
Displacement
16 20 25 32 40 50 63 80 100 120
Flange and ports
F ISO 3019/2 – BSP ISO 228/1 thread
FGR2 for size 2 gear pump - BSP ISO 228/1 thread (size 05 only)
Pressure setting range
H 20 - 120 bar (size 05)
30 - 100 bar (sizes 1 and 2)
50 - 90 bar (size 3)
L 15 - 50 bar (sizes 1 and 2)
30 - 50 bar (size 3)
Shaft rotation (viewed from shaft end)
R Clockwise
Seals
M NBR
E FPM (FKM)
Options
Single pump (without through drive)
A Through drive for double pump (only for F flange)
Modification number
XXXX Determined by manufacturer
EN 2.908.4.1/11.19
6
TECHNICAL INFORMATION
1.1.2 Specifications 1.1.9 Through drive models
1.1.6 Seals
The pump series is equipped with NBR or FPM (FKM) seals.
The actual seal material is specified in the ordering code.
1.1.7 Filtration
For maximum pump and component lifetime, the system should be protected
from contamination by effective filtration. The contamination level should be
within
18/16/13 acc. to ISO 4406/99
or
Class 7 acc. to NAS 1638.
Multiple pumps should be mounted in decreasing order of their torque. The sum
of the individual torques of the pumps must not exceed the maximum torque
permitted on the primary pump.
7
1.1.10 Installation notes
Step 1 Step 3
PVV102 pumps can be installed vertically or horizontally. The pump and motor must be connected using a gear
If the pump is installed above the oil level, particular coupling.
attention must be paid to the suction pressure. The During assembly, the minimum distance between the two
minimum cross-section of the suction line must be equal coupling halves must be strictly observed (see Detail A).
to or larger than the cross-section of the suction port of the Other types of motor-pump couplings are not permitted.
pump.
No radial and/or axial loads are permitted on the pump
The suction lines should be as short as possible, with shaft.
a minimum number of bends and without reducing the
cross‑section.
Step 4
When installing a HYDAC pump always ensure that the
During commissioning, the pump must first be run at
fluid in the pump is prevented from draining away during
maximum capacity (P connected to T), with the oil flowing
stoppages.
directly into the tank, in order to vent the pump.
Venting the pump can take several minutes.
Step 2
Pump filling (oil emerging from the discharge port) should
All return and drain lines must be positioned so that the
only take a few seconds. If not, the pump must be switched
returning oil is not drawn out again immediately by the pump
off and the procedure repeated.
(see diagram).
Provided that the system and pump are completely full
The oil tank must be the correct size to dissipate the thermal
of oil, the pump can be started up during subsequent
power generated by the system components, and to achieve a
operation against a maximum pressure of 30 bar.
low circulation speed.
During both initial commissioning and subsequent start-up
To ensure maximum pump working life, the suction oil
operations, the difference between the oil temperature and
temperature must never exceed 50 °C. In systems where
the ambient temperature (pump case) must not exceed
the pump runs for a long time at a zero flow setting it is
20 °C.
recommended that an oil cooler is installed. The pressure in
the drain line must never exceed the value specified.
The drain line must always feed directly into the tank,
independently of all other lines and it must extend under the
minimum oil level to avoid generating foam. In addition, the
drain line must be free of restrictions and situated as far as
possible away from the suction line.
Detail A 4-7
Motor Pump
A 0.05 A
Outlet
50 min. 100 min.
45°
50 min.
Drain
200 min.
Note:
For further information, see brochure section "Installation Instructions for Variable Displacement Vane Pumps".
8
1.1.11 Adjustments
Pump size Available Reduced Min. adjustable
displacement displacement by displacement
screw turn
[cm³/rev] [cm³/rev] [cm³/rev]
PVV102-05-16 17 9.7 3.1
PVV102-1-20 21 10 9.5
PVV102-1-25 26 10 15
PVV102-1-32 33 10 19
PVV102-2-40 42 16 27.5
PVV102-2-50 51 16 35.5
PVV102-2-63 63 16 43.5
PVV102-3-80 80 16 63
PVV102-3-100 100 16 80
PVV102-3-120 123 16 100
CONTROL OPTIONS
1.1.12 Mechanical pressure compensation 3
The PVV102 variable displacement vane pumps come in
four nominal sizes: size 05, 1, 2 and 3, each of which is
available with different displacements.
The low pressure pumps, type PVV102, are equipped with
a mechanical pressure regulating device.
The pumps consist of:
zza housing
zza rotor
zzvanes which convey the fluid between inlet and outlet
chambers
zza stator (adjustable ring) with variable eccentricity and
thus variable displacement
zzside pressure plates with axial hydrostatic balancing,
which limit the inlet and outlet chambers
zzpressure screw for balancing the pumps (must not be
adjusted by user)
zza displacement adjustment piston
zzmaximum displacement adjustment screw
zzpressure controller
zzpressure adjustment screw
p
EN 2.908.4.1/11.19
9
PERFORMANCE DATA
1.1.13 PVV102-05-16
Volumetric efficiency
30 9.0
25 7.5
20 6.0
15 4.5
10 3.0
5 1.5
0
0 20 40 60 80 100 120 140
Pressure (bar)
68
66
dB (A)
60
58
0 20 40 60 80 100 120 140
Pressure (bar)
Drainage flow
3.0
2.5
Drainage (l/min)
2.0
1.0
0.5
Pressure (bar)
EN 2.908.4.1/11.19
10
1.1.14 PVV102-1-20 / -25 / -32
40 76
35 10.5
74
30 9.0
Output flow (l/min)
dB (A)
20 6.0
70
15 4.5
68
10 3.0
5 1.5
66
0
0 3
20 40 60 80 100 120 64
0 20 40 60 80 100 120
Pressure (bar)
Pressure (bar)
40 2.0
35 10.5
30 9.0 1.5
Output flow (l/min)
Drainage (l/min)
25 7.5
20 6.0
1.0
15 4.5
10 3.0
0.5
5 1.5
0
0 20 40 60 80 100 120
0
Pressure (bar) 20 40 60 80 100 120
Pressure (bar)
Volumetric efficiency
PVV102-1-32
50
45 13.5
40 12.0
Output flow (l/min)
35 10.5
30 9.0
25 7.5
20 6.0
15 4.5
10 3.0
5 1.5
0
0 20 40 60 80 100 120
Pressure (bar)
EN 2.908.4.1/11.19
11
1.1.15 PVV102-2-40 / -50 / -63
80 76
70 14.0
74
60 12.0
Output flow (l/min)
dB (A)
40 8.0
70
30 6.0
68
20 4.0
10 2.0
66
0
0 20 40 60 80 100 120
64
0 20 40 60 80 100 120
Pressure (bar)
Pressure (bar)
80 5.0
70 14.0
4.0
60 12.0
Output flow (l/min)
Drainage (l/min)
50 10.0
3.0
40 8.0
30 6.0
2.0
20 4.0
10 2.0 1.0
0
0 20 40 60 80 100 120
Volumetric efficiency
PVV102-2-63
100
90 18.0
80 16.0
Output flow (l/min)
70 14.0
60 12.0
50 10.0
40 8.0
30 6.0
20 4.0
10 2.0
0
0 20 40 60 80 100 120
Pressure (bar)
EN 2.908.4.1/11.19
12
1.1.16 PVV102-3-80 / -100 / -120
160 78
140 28.0
76
120 24.0
Output flow (l/min)
dB (A)
80 16.0
72
60 12.0
40 8.0 70
20 4.0
68
0.0
0 50 60 90 3
66
0 50 60 70 80 90 100
Pressure (bar)
Pressure (bar)
160 6.0
140 28.0
5.0
120 24.0
Output flow (l/min)
Drainage (l/min)
100 20.0
4.0
80 16.0
60 12.0
3.0
40 8.0
20 4.0 2.0
0.0
0 50 60 90
Pressure (bar)
Volumetric efficiency
PVV102-3-120
200
180 36.0
160 32.0
Output flow (l/min)
140 28.0
120 24.0
100 20.0
80 16.0
60 12.0
40 8.0
20 4.0
0.0
0 50 60 90
Pressure (bar)
EN 2.908.4.1/11.19
13
DIMENSIONS
1.1.17 PVV102-05-16
6 h9
Drain port
3/8" BPS
Suction port
164
3/4" BPS
10
4x Ø
h7
246
Ø 20
66
22,5
Ø 80
Drain port
1/2" BPS
81,5
7
Ø1
8 22
01,
22
5
52 54 63
57
61
44 107
115
151
with through drive (-A) FGR2 flange (not for through drive version -A)
40 22
4x Ø
9
M12x1,5
Ø 14,7
4
9,5
96
Ø 36,5
32,5
1:8
5
28
131 35,75
71,5
175
EN 2.908.4.1/11.19
14
Multiple pumps
Primary pump PVV102-05- ... F
A F A F
G B E G B E
A F A F
G B E G B E
15
Multiple pumps
Primary pump PVV102-05- ... F
A F A F
G B E 9 G B E
7. PVV102-05 + SAE A
A Ø 82,5
G B 106,4
16
1.1.18 PVV102-1-20 / -25 / -32
86,5
Drain port
1/2" BSP
3
Suction port
201
1" BSP Pressure
port
113
h7
3/4" BSP
4x
Ø 25
Ø
315
11
Ø 100
28
114
Ø
12
10 26
46 26 5
8 h9 86,5
166
212 68,5 68,5
92,6 78
170,6
with through drive (-A)
190
236
EN 2.908.4.1/11.19
17
Multiple pumps
Primary pump PVV102-1- ... F
A F
A F
G B E G B E
A F A F
G B E G B E
18
Multiple pumps
Primary pump PVV102-1- ... F
A F A F
G B E G B E
A F A F
G B E 9 G B E
19
Multiple pumps
Primary pump PVV102-1- ... F
9. PVV102-1 + PVF100-1
A F
G B E
Ø 82,5
A 106,4
G B
20
1.1.19 PVV102-2-40 / -50 / -63
108 10
Drain port
236,5
Suction port
Pressure
146,5
port
Ø 32
372,1
Ø 125
35
135,6
Ø
4x
10 32
16
13
55 42 0
95 95 108
202,5
257,5 116,5 96
212,5
Ø 38
Ø 25
69,9
52,4
246,5
301,5
EN 2.908.4.1/11.19
21
Multiple pumps
Primary pump PVV102-2- ... F
A F A F
G B E G B E
A F A F
G B E G B E
22
Multiple pumps
Primary pump PVV102-2- ... F
A F A F
G B E G B E
A F A F
G B E G B E
23
Multiple pumps
Primary pump PVV102-2- ... F
A F A F
G B E 9 G B E
Ø 82,5
A 106,4
A F
G B E G B
24
1.1.20 PVV102-3-80 / -100 / -120
12
Drain port
1/2" BSP
3
Suction port
18
4x Ø Pressure
155,5
port
Ø 40
394
43
Ø
10
Ø
20
0
240 130,5
105 105
134,5
251,5
352
EN 2.908.4.1/11.19
25
Multiple pumps
Primary pump PVV102-3- ... F
A F A F
G B E G B E
A F A F
G B E G B E
26
Multiple pumps
Primary pump PVV102-3- ... F
A F A F
G B E G B E
A F A F
G B E G B E
27
Multiple pumps
Primary pump PVV102-3- ... F
A F A F
G B E G B E
A F A F
G B E 9 G B E
28
Multiple pumps
Primary pump PVV102-3- ... F
A F
G B E
Ø 82,5
A 106,4
G B
29
30
EN 2.908.4.1/11.19
1.2 VARIABLE DISPLACEMENT,
HYDRAULIC COMPENSATION
CONTENTS PVV103
31
ORDERING CODE
1.2.1 Variable Displacement Hydraulic Compensation
PVV103 – 05 – 16 F H R M - XXXX
Variable displacement vane pump
with hydraulic compensation
Size
05 1 2 3
Displacement
16 20 25 32 40 50 63 80 100 120
Flange and ports
F ISO 3019/2 – BSP ISO 228/1 thread
FGR2 for size 2 gear pump - BSP ISO 228/1 thread (size 05 only)
Pressure setting range
H 20 - 250 bar (sizes 05, 1 and 2)
40 - 250 (sizes 3-80/100)
40 - 120 (sizes 3-120)
Shaft rotation (viewed from shaft end)
R Clockwise
Seals
M NBR
E FPM (FKM)
Options
Single pump (without through drive)
A Through drive for double pump
Control type
– Pressure compensator
PCS002 Remote pressure compensator
PCS003 2-stage pressure compensator, one stage non-adjustable
PCS004 2-stage pressure compensator, adjustable
PCS005 Proportional pressure compensator
PCLS001 Load sensing and standard pressure control
PCLS002 Load sensing and remote pressure control
PCLS003 Load sensing and 2-stage pressure control, one stage non-adjustable
PCLS004 Load sensing and 2-stage pressure control, both adjustable
PCLS005 Load sensing and proportional pressure control
Modification number
XXXX Determined by manufacturer
EN 2.908.2.1/11.19
32
TECHNICAL INFORMATION
1.2.2 Specifications 1.2.9 Through drive models
1.2.6 Seals
The pump series is equipped with NBR or FPM (FKM) seals.
The actual seal material is specified in the ordering code.
1.2.7 Filtration
For maximum pump and component lifetime, the system should be protected from
contamination by effective filtration. The contamination level should be within
18/16/13 acc. to ISO 4406/99
or
Class 7 acc. to NAS 1638.
33
1.2.10 Installation notes
Step 1 Step 3
PVV103 pumps can be installed vertically or horizontally. The pump and motor must be connected using a gear
If the pump is installed above the oil level, particular coupling.
attention must be paid to the suction pressure. The During assembly, the minimum distance between the two
minimum cross-section of the suction line must be equal coupling halves must be strictly observed (see Detail A).
to or larger than the cross-section of the suction port of the Other types of motor-pump couplings are not permitted.
pump.
No radial and/or axial loads are permitted on the pump
The suction lines should be as short as possible, with shaft.
a minimum number of bends and without reducing the
cross‑section.
Step 4
When installing a HYDAC pump always ensure that the
During commissioning, the pump must first be run at
fluid in the pump is prevented from draining away during
maximum capacity (P connected to T), with the oil flowing
stoppages.
directly into the tank, in order to vent the pump.
Venting the pump can take several minutes.
Step 2
Pump filling (oil emerging from the discharge port) should
All return and drain lines must be positioned so that the
only take a few seconds. If not, the pump must be switched
returning oil is not drawn out again immediately by the pump
off and the procedure repeated.
(see diagram).
Provided that the system and pump are completely full
The oil tank must be the correct size to dissipate the thermal
of oil, the pump can be started up during subsequent
power generated by the system components, and to achieve a
operation against a maximum pressure of 30 bar.
low circulation speed.
During both initial commissioning and subsequent start-up
To ensure maximum pump working life, the suction oil
operations, the difference between the oil temperature and
temperature must never exceed 50 °C. In systems where
the ambient temperature (pump case) must not exceed
the pump runs for a long time at a zero flow setting it is
20 °C.
recommended that an oil cooler is installed. The pressure in
the drain line must never exceed the value specified.
The drain line must always feed directly into the tank,
independently of all other lines and it must extend under the
minimum oil level to avoid generating foam. In addition, the
drain line must be free of restrictions and situated as far as
possible away from the suction line.
Detail A 4-7
Motor Pump
A 0.05 A
Outlet
100 min.
45°
50 min.
Drainage
200 min.
50 min.
Note:
For further information, see brochure section "Installation Instructions for Variable Displacement Vane Pumps".
34
1.2.11 Adjustments (values may vary)
Pump size Available Reduced Min. adjustable
displacement displacement by displacement
screw turn
[cm³/rev] [cm³/rev] [cm³/rev]
PVV103-05-16 17 11 3.3
PVV103-1-20 21 10 9.5
PVV103-1-25 26 10 15
PVV103-1-32 33 10 19
PVV103-2-40 42 16 27.5
PVV103-2-50 51 16 35.5
PVV103-2-63 63 16 43.5
PVV103-3-80 80 16 63
PVV103-3-100 100 16 80
PVV103-3-120 123 16 100
3
CONTROL OPTIONS
Diagrams and characteristic curves for pressure control:
Pump with standard pressure control
Pump with pressure control with CETOP 03 (ISO 4401-03) interface
Ordering code P CS002 Ordering code P CS003 Ordering code P CS004
Pump with proportional pressure control with CETOP 03 (ISO 4401-03) interface
Ordering code P CS005
35
1.2.14 2-stage pressure control, one stage non-adjustable
Description Characteristics Hydraulic circuit
Pump with two pressure stages, one
of which is non-adjustable (set to the
minimum pressure of the pump).
EV – Solenoid valve not supplied.
Recommended valve Q
(24V nominal voltage):
Type Part no.
WSM06020V-01-C-N-24DG 3135462
Connection housing:
DPT06020-01x 558020
other nominal voltages and connectors on p
request
p
EN 2.908.2.1/11.19
36
CONTROL OPTIONS
Diagrams and characteristic curves for combined load sensing
and pressure control
Load sensing pump with standard pressure control
Ordering code P CLS001
Load sensing pump
with CETOP 03 (ISO 4401-03) interface
37
1.2.19 Load sensing and 2-stage pressure control, one stage non-adjustable
Description Characteristics Hydraulic circuit
Load sensing pump with two pressure
stages, one of which is non-adjustable
(set to the minimum pressure of the
pump).
EV – Solenoid valve not supplied. Q
Recommended valve
(24V nominal voltage):
Type Part no.
WSM06020V-01-C-N-24DG 3135462
Connection housing:
DPT06020-01x 558020 p
other nominal voltages and connectors on
request
p
EN 2.908.2.1/11.19
38
PERFORMANCE DATA
1.2.22 PVV103-05-16
78
30 15.0
74
25 12.5
Output flow (l/min)
dB(A)
66
15 7.5
3
10 5.0 62
5 2.5 58
0 54
0 40 80 120 160 200 240 280 0 40 80 120 160 200 240 280
Drainage flow
Values determined with pump on zero flow setting
6.0
5.0
Drainage (l/min)
4.0
3.0
2.0
1.0
39
1.2.23 PVV103-1-20 / -25 / -32
40 76
35 17.5
74
Output flow (l/min)
30 15.0
dB(A)
20
q max 10.0
70
15 7.5 q zero
68
10 5.0
5 2.5
q zero 66
0
0 40 80 120 160 200 240 280
64
0 40 80 120 160 200 240 280
Pressure (bar)
Pressure (bar)
35 17.5
30 15.0 6.0
Output flow (l/min)
Drainage (l/min)
25 12.5
q max
20 10.0
4.0
15 7.5
10 5.0
2.0
5 2.5
q zero
0
0 40 80 120 160 200 240 280
0 40 80 120 160 200 240 280
Volumetric efficiency
PVV103-1-32
50
45 22.5
40 20.0
35 17.5
Output flow (l/min)
30 15.0
25
q max 12.5
20 10.0
15 7.5
10
q zero 5.0
5 2.5
0
0 40 80 120 160 200 240 280
Pressure (bar)
40
1.2.24 PVV103-2-40 / -50 / -63
80 85
70 35.0
Output flow (l/min)
50 25.0
dB(A)
40 20.0
q max 75
q max
30 15.0
20i 10.0
70
q zero
10 5.0
q zero
0
0 40 80 120 160 200 240 280
65 3
Pressure (bar) 0 40 80 120 160 200 240 280
Pressure (bar)
70 35.0
8.0
Output flow (l/min)
60 30.0
Drive power (kW)
Drainage (l/min)
50 25.0
6.0
q max
40 20.0
30 15.0 4.0
20 10.0
2.0
10 5.0
q zero
0
0 40 80 120 120 200 240 280
0 40 80 120 160 200 240 280
Pressure (bar) Pressure (bar)
Volumetric efficiency
PVV103-2-63
100
90 45.0
80 40.0
Output flow (l/min)
70 35.0
60 30.0
50
q max 25.0
40 20.0
30 15.0
20
q zero 10.0
10 5.0
0
0 40 80 120 160 200 240 280
Pressure (bar)
41
1.2.25 PVV103-3-80 / -100 / -120
160 87
140 70.0
Output flow (l/min)
100 50.0
dB(A)
q max
80
q max 40.0
77
60 30.0
40 20.0
q zero
70
20
q zero 10.0
0.0
0 40 80 120 160 200 240 280
63
Pressure (bar) 0 40 80 120 160 200 240 280
Pressure (bar)
140 70.0
12.0
Output flow (l/min)
120 60.0
Drive power (kW)
Drainage (l/min)
100 50.0
9.0
q max
80 40.0
60 30.0 6.0
40 20.0
3.0
20
q zero 10.0
0.0
0 40 80 120 120 200 240 280
0 40 80 120 160 200 240 280
Pressure (bar) Pressure (bar)
Volumetric efficiency
PVV103-3-120
200
180 90.0
160 80.0
Output flow (l/min)
140 70.0
120 60.0
q max
100 50.0
80 40.0
60 30.0
40 20.0
20 q zero 10.0
0.0
0 40 80 120 160 200 240
Pressure (bar)
Drive power at maximum displacement Pressure peaks are due to the test system.
Pressure peaks exceeding 30 % of the maximum
EN 2.908.2.1/11.19
42
DIMENSIONS
1.2.26 PVV103-05-16
106
76 6
Suction port
1" BSP Pressure port
Drain port
3/8" BSP 3/4" BSP
130,5
22,5
Ø 20
105
228,5
Ø 80
Ø
7
4x
10
8
3
34
9
34 70 70
76 76
79
44 145
149
189
with through drive (-A) FGR2 flange (not for through drive version -A)
40 34
M12x1,5
4 9
Ø 14,7
4x Ø
9,5
Ø 36,5
96
63,5
5
35,75
28
166 71,5
210
Dim. [mm]
C 40.5
D 21.5
E 12.7
F 0.75
G 5.1
H 15.5
J 25.9
K 31
L 31.75
EN 2.908.2.1/11.19
43
Multiple pumps
Primary pump PVV103-05-16 F
A F
A F
G B E G B E
A F A F
G B E G B E
44
Multiple pumps
Primary pump PVV103-05-16 F
A F A F
G B E 9 G B E
7. PVV103-05 + SAE A
Ø 82,5
A
106,4
G B
45
1.2.27 PVV103-1-20 /-25 /-32
Drain port
1/2" BSP
86,5 203
Suction port
1" BSP 136,5
Pressure port
113
113
3/4" BSP
Ø 25 h7
250,5
Ø 100
28
114
9 Ø
4x
26
12
10
Ø
5
11
46 26
8 h9
166 86,5
212 68,5 68,5
92,6 78
170,6
with through drive (-A) Connection ISO 4401-06 (CETOP 03) for controller PC(L)S003/004.
Dim. [mm]
C 40.5
D 21.5
E 12.7
F 0.75
G 5.1
H 15.5
J 25.9
190 K 31
236 L 31.75
46
Multiple pumps
Primary pump PVV103-1-32 F
A F A F
G B E G B E
A F A F
G B E G B E
47
Multiple pumps
Primary pump PVV103-1-32 F
A F
A F
G B E
G B E
A F A F
G B E 9 G B E
48
Multiple pumps
Primary pump PVV103-1-32 F
Ø 82,5
A F A 106,4
G B E G B
49
1.2.28 PVV103-2-40 / -50 / -63
Drain port
108
1/2" BSP 225
10
Suction port
170
146,5
Pressure port
Ø 32
305,6
Ø 125
35
135,6
10
Ø
4x
16
32
0
13
55 42
108
202,5 95 95
257,5
116,5 96
212,5
35,7
26,2
12
4x Ø 10
4x M
Ø 38
Ø 25
69,9
52,4
246,5
301,5
Dim. [mm]
C 40.5
D 21.5
E 12.7
F 0.75
G 5.1
H 15.5
J 25.9
K 31
EN 2.908.2.1/11.19
L 31.75
50
Multiple pumps
Primary pump PVV103-2-
A F A F
G B E G B E
A F A F
G B E
G B E
51
Multiple pumps
Primary pump PVV103-2-
A F
A F
G B E
G B E
A F
A F
G B E
G B E
52
Multiple pumps
Primary pump PVV103-2-
A F A F
G B E 9 G B E
Ø 82,5
A F 106,4
A
G B E G B
53
1.2.29 PVV103-3-80 / -100 / -120
Suction port 8
Ø1
4x
179
155,5
Pressure port
Ø 40
Ø 160
43
327
148
10
Ø
20
37
0
68 48
240
105 105 130,5
308
134,5 117
251,5
42,9
30,2
12
4x M 10
4x M
51
32
77,8
284
352
Dim. [mm]
C 40.5
D 21.5
E 12.7
F 0.75
G 5.1
H 15.5
J 25.9
K 31
EN 2.908.2.1/11.19
L 31.75
54
Multiple pumps
Primary pump PVV103-3-
A F A F
G B E G B E
A F A F
G B E G B E
55
Multiple pumps
Primary pump PVV103-3-
A F A F
G B E G B E
A F
A F
G B E
G B E
56
Multiple pumps
Primary pump PVV103-3-
A F
A F G B E
G B E
A F A F
G B E 9
G B E
57
Multiple pumps
Primary pump PVV103-3-
82,5
106,4
A F A
G B E G B
58
1.2.30 Controllers
Peak pressure
PVV103-1- 80 ms 60 ms
PVV103-2 100 ms 80 ms
PVV103-3 120 ms 100 ms
Pressure peaks are due to the test system.
Pressure peaks exceeding 30 % (10 % for size 3) 15 bar
of the maximum operating pressure must be avoided. qmax ts Stabilisation time
Time (ms)
Curve peaks at 300 bar.
Curve starts at 15 bar.
59
Controller PCS003 dimensions PVV103-05 PVV103-1-2-3
60
Controller PCS005 dimensions PVV103-05 PVV103-1-2-3
61
Controller PCLS002 dimensions PVV103-05 PVV103-1-2-3
62
Controller PCLS004 dimensions PVV103-05 PVV103-1-2-3
63
64
EN 2.908.2.1/11.19
Variable Displacement
Vane Pumps:
Installation Manual
MECHANICAL COMPENSATION
3
PVV102-05-16
PVV102-1-20
PVV102-1-25
PVV102-1-32
PVV102-2-40
PVV102-2-50
PVV102-2-63
PVV102-3-80
PVV102-3-100
PVV102-3-120
HYDRAULIC COMPENSATION
PVV103-05-16
PVV103-1-20
PVV103-1-25
PVV103-1-32
PVV103-2-40
PVV103-2-50
PVV103-2-63
PVV103-3-80
PVV103-3-100
PVV103-3-120
EN 2.908.M.1/11.19
65
1. WARNING 5. PIPING
All HYDAC pumps are carefully checked during Suction line
manufacture and subjected to stringent testing cycles The suction lines should be as short as possible, with
before shipment. a minimum number of bends and without reducing the
To achieve optimum performance, avoid damage cross‑section.
and maintain the warranty coverage, the following The pipe end inside the reservoir should be cut at a
instructions regarding assembly and commissioning must 45° angle. There should be a minimum distance between
be strictly observed. the pipe end and the bottom of the reservoir of 50 mm and
the pipe end should be submerged in the oil by at least
100 mm under minimum operating conditions (see fig. 1).
2. INSTALLATION AND ASSEMBLY The minimum cross-section of the suction line pipe must
be equal to the internal diameter at the suction port of the
The PVV pumps can be installed vertically or horizontally. pump.
If the pump is installed above the oil level, particular The suction lines must be completely sealed.
attention must be paid to the suction pressure
(see point 6. Filtration and Fluid Types). Drain line
Cleanliness is essential during assembly! The drain line must always feed directly into the tank,
independently of all other lines.
The line must extend under the minimum oil level to avoid
3. FORCE TRANSMISSION generating foam and to ensure oil remains in the pump
after a lengthy stoppage.
The pump and motor must be connected using a gear
The drain line must be connected to the highest possible
coupling.
port to prevent the pump case from emptying.
During assembly, the minimum distance between
The drain line must be positioned so that the returning
the two coupling halves must be strictly observed
oil is not drawn into the pump again immediately
(see fig. 2).
(see fig. 1).
The pump shaft and motor shaft must be carefully
aligned: max. radial misalignment 0.05° mm; angular Pressure line
deviation less than 0.2° (see fig. 2). Ensure that the pressure line has adequate strength.
It is recommended that a non-return valve and an
There must be no radial or axial forces on the pump
automatic vent valve are fitted in the pressure line for
shaft.
trouble-free operation.
Other types of motor-pump couplings are not permitted.
4. FLUID RESERVOIR
The oil tank must be the correct size to dissipate the
thermal power generated by the system components,
and for a low circulation speed to be achieved (the
volume of oil should be approximately four times the
displacement of all the pumps). In systems where the
pump runs for a long time at a zero flow setting it is
recommended that an oil cooler is installed.
The maximum operating temperature must
never exceed 60 °C.
To ensure maximum pump working life, the suction oil
temperature must never exceed 50 °C.
EN 2.908.M.1/11.19
66
6. FILTRATION AND FLUID TYPES
Size 05 1 2 3
Geometric
[cm³/rev] 16 20 - 25 - 32 40 - 50 - 63 80 - 100 120
displacement
L: 15 - 50 L: 30 - 50
102 H: 20 - 120
Setting range for H: 30 - 100 H: 50 - 90
[bar]
pressure controller
103 H: 20 - 250 H: 40 - 250 H: 40 - 210
Max. permitted
[bar] 1
drain pressure
Viscosity in starting
operation in full flow [cSt, mm²/s] Max. 400
condition
Viscosity index
according to ISO [cSt, mm²/s] Min. 100
2909
Max. contamination level of operating fluid 20/18/15 acc. to ISO 4406: 1999, Class 9 acc. to NAS 1638
67
7. COMMISSIONING 8. ADJUSTMENTS
Check before initial start-up whether all valves and Pressure (fig. 4/5) and flow (see 10. Flow adjustment
shut-off valves are open and all protective caps have screw) must only be changed at the pump using the
been removed. Fill the pump via the drain port and then adjustment screws on the unit.
remount the drain line.
Notice: the pressure must only be adjusted when
The container must be filled with oil.
the pump is at zero flow setting (i.e. when P is closed).
Ensure that the pump shaft can be rotated
No other alterations may be made to the pump.
manually without any resistance.
On pumps with through drive option A in sizes 1, 2 and
3 this may be checked by removing the cover B as
shown in fig. 3. The shaft end A may then be turned by
hand. Alternatively, the protective hood can briefly be
unscrewed from the fan of the electric motor and the
pump can be turned via the fan.
Check that the direction of rotation of the motor
corresponds with the direction of rotation of the pump.
Pump: clockwise viewed from shaft end.
Start the motor in jogging mode, allowing free circulation
of the fluid to the reservoir, to aid venting of the pump.
The pump should be completely vented within
5 seconds. If it is not, switch off the motor and
investigate the cause. The pump must not run dry.
During initial switch-on the pump must run at maximum
flow (P connected to T) with the fluid flowing without
pressure and directly into the reservoir for several
minutes (7 to 10 minutes).
After this time, all air should be completely eliminated
from the system. To aid this procedure, type PVV103
has a vent valve on the pressure controller: unscrew the
plug to release the air and then close plug.
Subsequent start-ups may only be carried out with a
maximum pressure of 30 bar, on the condition that the
system and pump are completely full of oil.
If the pump is set via the flow limitation to less than
50 % of the maximum flow, the system may only be
switched on if the pump and system are completely
full of oil
(see point "10. Flow adjustment screw").
During the initial start-up operation and subsequent
start-ups the difference in temperature between the
pump (environment) and the hydraulic fluid must
not exceed 20 °C.
If this is the case, the pump may be switched on only in
short intervals of approximately 1 to 2 seconds (jogging
mode), without pressure, until the temperatures have
equalised.
In the event of queries or for further information, please
refer to the HYDAC Pump Catalogue or contact HYDAC
Drive Center's technical sales service.
EN 2.908.M.1/11.19
68
9. DIMENSIONS
Fig. 1
Outlet
100 min.
45°
50 min.
Drain
200 min.
50 min.
Fig. 2 Fig. 3
4-7
Motor Pump
A 0.05 A
Fig. 4 Fig. 5
PVV102 PVV103
Note:
150 min.
The sum of the individual torques of the pumps must not
exceed the maximum torque permitted on the primary
pump.
69
10. FLOW ADJUSTMENT SCREW
Do not change!
Lock nut
PVV102: AF width 17 mm
PVV103: AF width 24 mm
Do not change!
EN 2.908.1/11.19
71