PR1P Position and Distance Measurement 02 2016 en 345958
PR1P Position and Distance Measurement 02 2016 en 345958
PROFILE-STYLE TRANSDUCER
WITH DIGITAL DPI/IP INTERFACE
Micropulse position measurement systems Features
in a profile housing are non-contact,
absolute measurement systems for ■ ■ High-accuracy machine positioning
accurately measuring one or more with synchronous data transmission
measurement paths. The digital DPI/IP and 1μm resolution
pulse interface is compatible with ■ ■ Fast, dynamic measuring with
BTL7-P511 PROFIL
Interface Digital Pulse Interface (DPI), Integrated Protocol (IP)
Stroke length max. 7620 mm
Repeat accuracy ≤ ±5 µm, (typ. ±2,5 μm)
Sampling rate max. 4280 Hz
Max. number of position encoders 16
Supply voltage 10…30 V DC
Ambient temperature –40...+85 ºC
Sock 150 g
Vibration 20 g
Enclosure rating per IEC 60529 IP67, IP68 for cable version
Housing material Aluminium
Connection Cable, connectors: M12 – 8-pin, M16 – 8-pin
Dimensions 35 × 36,8 × 145 mm + stroke length
Ordering example:
B T L 7 - P 5 1 1 - M _ _ _ _- P - _ _ _ _
Standard
nominal strokes (mm) Connection
50...7620 mm in S32 Connectors
1-mm-increments S115 Connectors
KA02 PUR cable 2 m
KA05 PUR cable 5 m
KA10 PUR cable 10 m
KA15 PUR cable 15 m
ACCESSORIES
CONNECTORS
www.balluff.com
Balluff GmbH · Schurwaldstrasse 9 · 73765 Neuhausen a. d. F. · Germany · Phone +49 7158 173-0 · Fax +49 7158 5010 · [email protected]