Site Acceptance Test Report: 11kV, 1250A, 4 WAY PANEL

This document summarizes the site acceptance test report for a current transformer used in the infrastructure works for a 300 villa housing project in Al Hayer, Abu Dhabi. It describes the visual inspection, insulation testing, polarity testing, winding resistance measurement, magnetizing characteristics test, and ratio test that were performed on the current transformer. The test was witnessed and approved by representatives from the power contractor, consultant, main contractor, subcontractor, and end user.

Uploaded by

Jayaprakash M P
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views

Site Acceptance Test Report: 11kV, 1250A, 4 WAY PANEL

This document summarizes the site acceptance test report for a current transformer used in the infrastructure works for a 300 villa housing project in Al Hayer, Abu Dhabi. It describes the visual inspection, insulation testing, polarity testing, winding resistance measurement, magnetizing characteristics test, and ratio test that were performed on the current transformer. The test was witnessed and approved by representatives from the power contractor, consultant, main contractor, subcontractor, and end user.

Uploaded by

Jayaprakash M P
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 3

SITE ACCEPTANCE TEST REPORT

11kV, 1250A, 4 WAY PANEL


DESIGN AND BUILD OF 300 VILLAS EMIRATI HOUSING PROJECT IN AL HAYER
PROJECT
WITH INFRASTRUCTURE WORKS
CLIENT ABU DHABI HOUSING AUTHORITY SUBSTATION No AH 0896
END USER AL AIN DISTRIBUTION COMPANY.
CONSULTANT ALTORATH INTERNATIONAL FEEDER No.
MAIN CONTRACTOR NAEL GENERAL CONTRACTING EST
HYDROPOWER ENERGY & GENERAL
SUB CONTRACTOR SCHEME NO
CONSTRUCTION LLC.
EQUIPMENT NEUTRAL - CURRENT TRANSFORMER LOCATION Al HAYER

CURRENT TRANSFORMER TEST


1. NAME PLATE DATA : DATE:
Description
MAKE
TYPE
PURPOSE
RATIO
CLASS
BURDEN (VA)
SL.NO

2. VISUAL TESTS:
a. CT correctly connected as per drawing : OK
b. All terminals tightness secured : OK
c. Grounding and shorting connections are secured : OK

3. INSULATION TESTS:
Amb Temp : °C
VALUES IN GΩ
N-Phase
Ground CT – 2 CT – 1 Test voltage
PRIMARY Primary: 5000 V
CT – 1 Sec – Sec: 500 V

TEST CARRIEDOUT WITNESSED BY


WITNESSED BY WITNESSED BY APPROVED BY
BY (HYDROPOWER
(ALPHAPOWER) (ALTORATH) (AADC) ( AADC )
ENERGY)

SIGNATURE

NAME

DATE
SITE ACCEPTANCE TEST REPORT
11kV, 1250A, 4 WAY PANEL
DESIGN AND BUILD OF 300 VILLAS EMIRATI HOUSING PROJECT IN AL HAYER
PROJECT
WITH INFRASTRUCTURE WORKS
CLIENT ABU DHABI HOUSING AUTHORITY SUBSTATION No AH 0896
END USER AL AIN DISTRIBUTION COMPANY.
CONSULTANT ALTORATH INTERNATIONAL FEEDER No.
MAIN CONTRACTOR NAEL GENERAL CONTRACTING EST
HYDROPOWER ENERGY & GENERAL
SUB CONTRACTOR SCHEME NO
CONSTRUCTION LLC.
EQUIPMENT NEUTRAL - CURRENT TRANSFORMER LOCATION Al HAYER

4. POLARITY (FLICK TEST):


CT N– Phase
S1-S2

5. WINDING RESISTANCE MEASUREMENT (secondary):


Amb Temp :36.2 °C
Phase Resistance in N phase
CT At room temp. At 75ºC
S1 – S2

6. MAGNETIZING CHARACTERISTICS TEST:


Excitation Current (mA)
CT NO CT Ratio Excitation Voltage
N

TEST CARRIEDOUT WITNESSED BY


WITNESSED BY WITNESSED BY APPROVED BY
BY (HYDROPOWER
(ALPHAPOWER) (ALTORATH) (AADC) ( AADC )
ENERGY)

SIGNATURE

NAME

DATE
SITE ACCEPTANCE TEST REPORT
11kV, 1250A, 4 WAY PANEL
DESIGN AND BUILD OF 300 VILLAS EMIRATI HOUSING PROJECT IN AL HAYER
PROJECT
WITH INFRASTRUCTURE WORKS
CLIENT ABU DHABI HOUSING AUTHORITY SUBSTATION No AH 0896
END USER AL AIN DISTRIBUTION COMPANY.
CONSULTANT ALTORATH INTERNATIONAL FEEDER No.
MAIN CONTRACTOR NAEL GENERAL CONTRACTING EST
HYDROPOWER ENERGY & GENERAL
SUB CONTRACTOR SCHEME NO
CONSTRUCTION LLC.
EQUIPMENT NEUTRAL - CURRENT TRANSFORMER LOCATION Al HAYER

7. RATIO TEST:

Primary Current Secondary Current


Phase CT Ratio % Error Remarks
Injected ( A ) Measured ( A )

N S1 – S2

***NOTE: Refer Enclosed CT Analyzer Test Report from 4 to 7

TEST EQUIPMENTS USED:

INSTRUMENT NAME MAKE MODEL SERIAL NO CALIBRATION DUE DATE


Insulation Tester
CT Analyzer Kit OMICRON CT Analyzer KM285H

TEST CARRIEDOUT WITNESSED BY


WITNESSED BY WITNESSED BY APPROVED BY
BY (HYDROPOWER
(ALPHAPOWER) (ALTORATH) (AADC) ( AADC )
ENERGY)

SIGNATURE

NAME

DATE