MCC-1000MD

HD Video Camera
The MCC-1000MD two-piece medical grade camera features
latest-generation image sensor technology which offers better
low-light sensitivity than traditional equivalent-sized image sensors.

Sony’s expertise and knowledge, accumulated over decades


as a world-leading supplier of broadcast equipment,
are consolidated in this camera.

The camera head is equipped with 3 HD CMOS 1/2.8 inch


image sensors with an effective pixel count of approximately
2,070,000 pixels (1920 x 1080). It features latest-generation
image sensor technology for better low-light sensitivity.

Together with Sony’s medical-grade recorders and monitors,


the MCC-1000MD is an ideal solution for capturing and
recording microsurgery procedures.*
* The MCC-1000MD acquires images which are intended for use with
secondary view and can not be used for surgical and diagnostic purposes.

Application
The MCC-1000MD is suitable for use primarily with medical Captured live surgical video images from MCC-1000MD can be
microscope procedures including neurology and displayed on a surgical monitor inside the OR for OR staff or
ophthalmology in hospital operating rooms, surgical centers, displayed outside the OR for wider educational use. In addition,
hospital examination rooms and similar medical environments. by capturing content from the camera on a recorder, users can
Its compact and lightweight design allows the camera’s comply with the increasing need to maintain surgical records.
C-mount head to be easily mounted on most existing surgical High-quality images contribute not only to the improvement
microscopes. Users can deploy two of the MCC-1000MD of surgery and inspection, but also to conference and
cameras to achieve 3D shooting capability. education applications.

In the OR Secondary use

HD 2pcs Camera HD 2D Monitor 4K 2D Monitor


MCC-1000MD LMD-2735MD LMD-X310MD (A.I.M.E)

Conference

Camera Head

Video Baseband Cable


Education in the OR

Camera Control Unit HD Video Recorder


HVO-3300MT/
HVO-550MD

Surgical Microscope
Discussion in the hospital
* The HDR-compatible product in this diagram is MCC-1000MD.
Capture Minute Surgical Details High Sensitivity Designed for Near Darkness
Designed to deliver a high level of detail in microsurgery A high sensitivity of F20 means the MCC-1000MD can capture
applications, the MCC-1000MD camera head combines three remarkably clear video even in near darkness, where even in
1/2.8-inch-type Exmor R™ CMOS sensors which can record up near darkness due to poor/uneven lighting conditions. This
to 2.07 million pixels (1920 x 1080). With Sony’s Exmor R CMOS level of sensitivity allows the camera to capture more natural
sensor and image processing technologies, the MCC-1000MD color and suppresses noise caused by higher gain. The camera
provides sensitivity of F20, a signal-to-noise ratio of 63 dB, and can also capture and reproduce very brightly lit areas at
a horizontal resolution of 1000 TV lines or more. standard exposure level.
The MCC-1000MD is also capable of capturing Full HD images
with 1,080 effective scanning lines even in progressive format, Picture Profile Function
allowing you to capture details and movement in videos with Picture profile is a menu that adjusts and changes the
greater clarity than in interlaced format. parameters to determine the characteristics of the image. The
Simultaneous video outputs from two MCC-1000MD units can MCC-1000MD has six pre-installed picture profiles which match
be synchronized, allowing capture of HD 3D stereoscopic video various shooting conditions in ophthalmic surgery and
images. These can be recorded by the Sony HVO-3300MT Video Fluorescein observation. Simply select the picture profile to
Recorder or viewed on Sony’s 3D surgical monitors such as the shoot various types of surgery with optimum picture quality
LMD-X550MT. easily and immediately.

Useful Camera Functions


Other image adjustment features include Auto Exposure, Knee,
Digital Zoom, Picture Profile, Picture Flip, and GenLock. The
picture flip function can turn the camera picture horizontally,
vertically, or both horizontally and vertically according to the
High Dynamic Range (HDR) mode microscope.
The MCC-1000MD supports HLG and 2.4 wide gamma* in HDR
(High Dynamic Range) mode, with a wider range of brightness Various Outputs for Flexible Connectivity
levels to capture surgical images with even greater contrast and The MCC-1000MD has enough output flexibility to fit into a
realism. Moreover, since HDR technology covers wider range of medical environments, with HDMI, SDI (3G-SDI),
brightness and also rich colors, it is easier to reproduce truer S-video and Composite video outputs. This makes is easy to
instances of color - within the gradation. With HDR mode, integrate the camera seamlessly into your current set up - be it
objects with surfaces that are difficult to reproduce – are visually SD or HD while ensuring you’re future-proofed for migration to
improved, such as wetness, dark shadows, or glossiness. any other workflow. All of the camera’s outputs are active
simultaneously, so it can be used with a second or even third
MCC-1000MD monitor in the operating room.
BT.709 & HDR

10000
3D-SYNC IN (3D-SYNC input)
connector, 3D-SYNC OUT
1000
Conventional camera (3D-SYNC output) connector (BNC type)
BT.709 & SDR VIDEO (composite video)
100
Y

output connector (BNC type)

10 Remote contact switch connector 1, 2


CAMERA connector (stereo mini jack)

1
0.8 0.8
0.6 0.6 CAMERA 3D-SYNC
0.4 0.4 VIDEO 1 2
0.2 0.2
y 0 0 x

SDI 1 SDI 2 S VIDEO RS-232C

RS-232C connector
(D-sub 9-pin)
S VIDEO output connector
(mini DIN 4-pin)
SDI output connector 1, 2 HDMI output connector
(BNC type) (HDMI, type A)

SDR HDR
* Simulated images
* 2.4 wide gamma is a gamma curve that can suppress
blown-out highlights in high-luminance areas.
3D Shooting Capability Compatible Optional Camera Adapter
Users can deploy two of the MCC-1000MD cameras to achieve a 3D To attach the MCC-1000MD to a surgical microscope, a compatible
shooting capability. When connecting two units together 3D images camera adapter is recommended.
can be shot by synchronizing video frames of each camera. The optional CCMA-2DAR Camera Adapter enables acquisition and
recording of 2D video images during procedures such as brain
Fluorescein Mode surgery and ophthalmic surgery. It is compatible with widely used

The MCC-1000MD is equipped with a fluorescein mode that produces surgical microscopes with excellent imaging performance and setup

optimal image quality when shooting objects that are fluorescing flexibility due to a compact body.

with fluorescein. It adjusts the saturation and hue for only the color This adapter can also be used with compatible 4K video cameras,

fluorescence due to the excitation light. and thanks to its capabilities, can maximize the performance of the
MCC-1000MD with high resolution and sensitivity.

Convenient Foot Switch Operation


The MCC-1000MD can be connected to two foot switches, which
allow hands free control over functions such as switching the picture
profile and pausing the image on screen.

Specifications
Camera Head Output Connectors HDMI OUT (x1) (HDMI connector)
Image Device 1/2.8 type “Exmor R” CMOS image sensor, RGB 3CMOS type HD-SDI OUT (x2) (BNC, HD/3G)
Effective Pixels 1920 (H) x 1080 (V) Input/Output Connectors CAMERA (x1) (20-pin, round)
Lens Mount C-mount RS-232C (x1) (D-sub 9-pin)
Sensitivity F13 (Typical) (At 1080/59.94i, 89.9% reflection, 2000 lx) 3D-SYNC IN, OUT (BNC)
F20 (Typical) (At 1080/59.94i, 89.9% reflection, 2000 lx, Other Connector Equipotential ground connector (x1)
“High Sensitivity” is “ON”)
General
Picture S/N 63 dB (Y) (Typical)
Power Requirements 100 V to 240 V AC, 50/60Hz
Horizontal Resolution 1000 TV lines or more
Input Current 0.40 A – 0.25 A
Gain 0 dB to 30 dB
Operating Temperature 0°C to 40°C (32°F to 104°F)
Shutter Speed 1/60 to 1/10000
Operating Humidity 20% to 80% (no condensation allowed)
Slow Shutter 2 to 8 Frames
Storage and Transport Temperature -20°C to +60°C -4°F to +140°F)
Camera Cable Connector 20-pin, round
Storage and Transport Humidity 20% to 90% (no condensation allowed)
SDI Video Format 1080/60i
1080/60p Mass (Camera Head) approx. 60 g (approx. 2.1 oz)
1080/50i Mass (Camera Control Unit) approx. 1.9 kg (approx. 4 lb. 3 oz)
1080/50p Dimensions (Camera Head) (WHD, approx. 34 x 39 x 43 mm (approx. 1 3/8 x 1 9/16 x 1 3/4 in.)
Camera Control Unit excluding longest protrusions) *1
Picture Profile Yes (Six settings) Dimensions (Camera Control Unit) approx. 200 x 62 x 264 mm (approx. 7 7/8 x 2 1/2 x 10 1/2 in.)
Picture Flip Yes (exclusing longest protrusions)
Freeze Function Yes (capturing a still image) Supplied Items Lens mount cap (x1)
Color Bar Off/Multi/EBU 75%/EBU 100%/Test Saw Before Using This Unit (x1)
Camera Synchronization for 3D-shooting Yes CD-ROM (Instruction for Use in PDF format (x1)
AC Power Operation Yes Warranty Booklet (x1)  
Service Contact List (x1)
Connectors
*1 The values for dimensions are approximate.
Input Connectors Remote contact switch connectors 1, 2
(Stereo mini jack)
Output Connectors VIDEO OUT (x1) (BNC) This product is distributed to the US and EU as a medical device and satisfies product safety
standards (e.g. IEC 60601-1). For more details, please contact your nearest Sony sales office
S VIDEO OUT (x1) (4-pin mini DIN connector)
or an authorized dealer.

Optional Accessories

CCMA-2DAR CCMC-SA06/SA10/SA15 CCMC-EA05 FS-24


2D Camera Adapter Camera Cables (Standard cable Camera Cable (Extension cable 5m) Foot Switch
6m/10m/15m)
* The FS-24 has an Ingress Protection rating of IPx3.
Therefore, do not operate in environments exposed
to splashing liquids (e.g.,surgical operating rooms).
For safety, use a device with a rating of IPx6 or
higher when operating in such environments.
Distributed by

©2019 Sony Corporation. All rights reserved.


Reproduction in whole or in part without written permission is prohibited.
Features and specifications are subject to change without notice.
All non-metric weights and measurements are approximate.
Sony is a registered trademark of Sony Corporation.
All other trademarks are the property of their respective owners.
Please visit Sony’s professional website or contact your Sony representative for specific
MK20306V2OHB19MAY models available in your region.

You might also like