Type 1279, 1377, 1379 & 2462 Receiver Gauges

This document provides specifications for Ashcroft Type 1279, 1377, 1379 & 2462 receiver gauges. The gauges feature a 41⁄2 inch bourdon tube, epoxy coating for corrosion resistance, and a stainless steel rotary movement. They are used with pneumatic transmitters to indicate various process parameters transmitted via proportional air pressure variations. Standard transmitter output is 3-15 psi, and the gauges are available in numerous pressure and compound ranges.

Uploaded by

shaggy0078
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views4 pages

Type 1279, 1377, 1379 & 2462 Receiver Gauges

This document provides specifications for Ashcroft Type 1279, 1377, 1379 & 2462 receiver gauges. The gauges feature a 41⁄2 inch bourdon tube, epoxy coating for corrosion resistance, and a stainless steel rotary movement. They are used with pneumatic transmitters to indicate various process parameters transmitted via proportional air pressure variations. Standard transmitter output is 3-15 psi, and the gauges are available in numerous pressure and compound ranges.

Uploaded by

shaggy0078
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Type 1279, 1377, 1379 & 2462 Receiver Gauges

• 41⁄2˝ full-size Bourdon tube Receiver Gauge Ranges


• Patented Duratube™ with 0/1 0/75 30/80 100/600
0/2 0/80 5/110 200/700
as-welded-tube construction 0/3 0/85 20/120 100/800
controls stress for longer life 0/4 0/90 40/120 200/800
• “Round Cap Tip” construction 0/5 0/95 20/150 300/800
0/6 0/100 30/150 400/800
lowers stresses for longer life 0/7 0/120 40/150 450/800
• Easily adjustable, self-locking 0/8 0/140 50/150 500/800
micrometer pointer 0/9 0/160 30/180 650/800
0/10 0/180 130/180 200/900
• Exclusive Teflon coated 400 0/11 0/200 100/200 400/900
series stainless steel rotary 0/12 0/250 20/220 700/900
movement for longer life 0/14 0/300 40/220 200/1000
0/15 0/350 30/240 400/1000
Type 1279 • Epoxy-coated system for 0/16 0/400 100/240 500/1000
superior corrosion resistance 0/17 0/500 30/250 600/1000
0/18 0/600 50/250 800/1000
Ashcroft® receiver gauges are used in 0/19 0/700 100/250 200/1100
0/20 0/760 30/300 400/1200
conjuction with pneumatic transmitters 0/21 0/800 50/300 500/1200
to indicate pressure, temperature, flow or 0/25 0/900 80/300 600/1200
other process parameters that can be 0/26 0/1000 100/300 1000/1500
transmitted by proportional variations in 0/28 0/1500 50/350 300/1600
0/30 0/2000 80/350 1000/1600
air pressure. Available in standard trans- 0/35 0/3000 150/350 600/1800
mitter output air pressure range of 3-15psi. 0/40 0/4000 100/400 900/1800
Type 1377 0/45 0/5000 150/400 1200/1800
0/50 0/10,000 50/500 700/2000
0/55 0/15,000 100/500 1000/2500
0/60 0/20,000 200/500 1500/2500
0/65 0/30,000 300/500 900/3000
0/70 0/50,000 200/700 1500/3000
Square Root Ranges
0/5 0/70 0/300 0/1500
0/10 0/80 0/350 0/2000
0/15 0/90 0/400 0/3000
0/20 0/100 0/500 0/4000
0/25 0/125 0/600 0/5000
0/30 0/150 0/700 0/10,000
Type 1379 0/40 0/175 0/800
0/50 0/200 0/900
0/60 0/250 0/1000
Compound Ranges
30˝ Hg/0/15 psi
30˝ Hg/0/30 psi
30˝ Hg/0/60 psi
30˝ Hg/0/100 psi
30˝ Hg/0/150 psi
30˝ Hg/0/500 psi
30˝ Hg/0/800 psi

HOW TO ORDER: 45 1279 AS* 04L XPR 3-15 psi


Type 2462
From Table A, Dial Size: 41⁄2˝ :
From Table A, Case Type Number: 1279
From Table B, Bourdon tube and socket:
From Table B, Connection: 1⁄4 NPT (02), 1⁄2 NPT (04), Lower (L), Back (B)
From Optional Features:
Input pressure and dial range from range table
(*) “S” denotes solid front case design

All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA

BULLETIN RG-1
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
© Ashcroft Inc. 2016 08/16 email: [email protected] • www.ashcroft.com
Type 1279, 1377, 1379 & 2462 Receiver Gauges

GAUGE TYPE SYSTEM RANGE NPT


DIAL SIZES POINTER MOVEMENT ACCURACY
NUMBER ASSEMBLY psi CONN.

1279AS-XPR(2) 41⁄2

1377AS-XPR(3) 41⁄2, 6, 81⁄2


Phosphor Rotary geared, ASME
bronze Black, stainless steel B 40.1

12
Bourdon tube, 3-15 micrometer Teflon® coated Grade 2A
(1⁄4 Opt.)
brass socket; adjustable pinion gear and (±0.5%
1379AS-XPR(4) 41⁄2, 6, 81⁄2 (316 stainless segment shaft of span)
steel optional

2462AS-XPR(5) 6

GAUGE TYPE CONNECTION MOUNTING MOUNTING MOUNTING


NUMBER DIAL SIZES LOCATION TYPE METHOD METHOD CODE
Lower/Back Stem/Surface – –
1279AS-XPR(2) 41⁄2
Back Flush 1278M Ring X56
Back Flush – –
1377AS-XPR(3) 41⁄2, 6, 81⁄2
Lower/Back Stem/Surface – –
Back Flush 41⁄2 & 6, 1278M Ring – 81⁄2, Wide Ring std. –
1379AS-XPR(4) 41⁄2, 6, 81⁄2
Lower/Back Stem – X56 (1)
(5) Lower/Back Surface Surface Mounting Ring XBF
2462AS-XPR 6
Back Flush Flush Mounting Bracket XBQ
(1) 81⁄2˝ available with flush mounting standard.
(2) Consult 1279 Duragauge® pressure gauge datasheet (Bul DU-1) for full products details available at www.ashcroft.com.
(3) Consult 1377 Duragauge® pressure gauge datasheet (Bul DU-2) for full products details available at www.ashcroft.com.
(4) Consult 1379 Duragauge® pressure gauge datasheet (Bul DU-3) for full products details available at www.ashcroft.com.
(5) Consult 2462 Duragauge® pressure gauge datasheet (Bul DU-4) for full products details available at www.ashcroft.com.

All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA

BULLETIN RG-1
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
© Ashcroft Inc. 2016 08/16 email: [email protected] • www.ashcroft.com
Type 1279, 1377, 1379 & 2462 Receiver Gauges

Case Type 1279 Dimensions

A B LL Mounting hardware
L supplied by Ashcroft

CC
M
Hole in
H panel
C
F A-1
K
G
T
T
3-L dia. holes
on E dia. B.C.
D
14/ NPT or 41⁄2˝ Type 1279 with
12/ NPT Type 1278M flush
41⁄2˝ Lower Connection 41⁄2˝ Back Connection mounting ring

Dial
Size A B C D E F G H K L T V Weight
Inches (lbs)
5.81 3.36 5.07 1.06 5.375 1.62 4.08 .73 2.62 .22 .62 2.625
21⁄2
(147.6) (85.3) (128.7) (40.6) (137) (41.2) (103.7) (18.4) (66.6) (5.5) (15.7) (67)
41⁄2

Case Type 1377 Dimensions

S Nuts & washers B Nuts & washers


not supplied by S not supplied by
A B U A B Dresser
Dresser

C T C
T M M
Hole in Hole in
panel F
F panel

G G
H
T
H
D K P K
3 Mounting studs CC threaded LL 3 Mounting studs CC threaded LL
equally spaced on E dia. B.C. equally spaced on E dia. B.C.
D
1 1
4 ⁄2˝ & 6˝ Lower Connection 4 ⁄2˝ & 6˝ Back Connection 1
8 ⁄2˝ Lower Connection 1
8 ⁄2˝ Back Connection

Dial
Size A B C D E F G H K M P S T U CC LL Weight

63⁄32 53⁄8 315⁄16 47⁄8


Inches (lbs)

21⁄2
(148) (137) (100) (124)
41⁄2 #10-24

79⁄16 27⁄8 43⁄4 11⁄16 7 15⁄8 41⁄2 13⁄8 11⁄16 61⁄2 21⁄8 5⁄8 5⁄8 3⁄4 1⁄8–1⁄2
⁄4–20 3
(192) (73) (121) (27) (178) (41) (114) (35) (27) (165) (54) (16) (16)
1
6
(19) (3)(13)
101⁄16 95⁄8 6 9 1
⁄4–20 41⁄2
(257) (244) (152) (229)
81⁄2

All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA

BULLETIN RG-1
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
© Ashcroft Inc. 2016 08/16 email: [email protected] • www.ashcroft.com
Type 1279, 1377, 1379 & 2462 Receiver Gauges

Case Type 1379 Dimensions


B Nuts & washers
S not supplied by
A B N Ashcroft
A B
J

W S

H T C
C M
F Hole in
F panel
V
G
G G
T H
T T
3-L dia. holes
on E dia. B.C.
D P K
3 Mounting studs CC threaded D
equally spaced on E dia. B.C. D P LL

41⁄2˝ & 6˝ Lower Connection 41⁄2˝ & 6˝ Back 81⁄2˝ Lower Conn. 81⁄2˝ Wall Conn. 81⁄2˝ Back Conn.

Dial
Size A B C D E F G H J K
Inches

513⁄16 313⁄32 47⁄8 15⁄8 53⁄8 11⁄8 315⁄16


(148) (86) (124) (41) (137) (42) (100) 7
⁄8 11⁄16
41⁄2

(20) (27) —
79⁄16 31⁄2 65⁄8 15⁄8 7 11⁄2 41⁄2
(192) (89) (162) (41) (178) (42) (114)
6

101⁄16 27⁄8 43⁄4 11⁄16 95⁄8 15⁄8 6 13⁄8 11⁄16



(256) (73) (121) (27) (244) (41) (152) (35) (27)
81⁄2

Dial
Size L M N P S T V CC LL Wgt.
Inches (lbs)

21⁄2
.218 — — 21⁄8 — ⁄85
25⁄8 —
41⁄2

(6) (54) (16) (67) ⁄8- ⁄2


31⁄8
1 1
6
(3)(13)
9 39⁄32 11⁄16
— — — 41⁄2
(228) (83) (17)
81⁄2 #10-24

Case Type 2462 Dimensions


3-L Dia holes on E Dia. B.C.

LL
A B H KK
J

H-I
M
C C Hol
panel
F

G
T
T
Stem Surface S Panel
D
6˝ Lower Connection 6˝ Back Connection
Dial LL
Size A B C D E F G H H-1 J KK L M S T Wgt.
Min. Max.
Inches (lbs)
63⁄8 27⁄16 43⁄4 7⁄8 53⁄8 15⁄8 315⁄16 49⁄16 49⁄32 5⁄64 211⁄16 .218 1⁄16 1⁄2 6 11⁄16 5⁄8
6
(163) (62) (120) (22) (137) (42) (100) (116) (109) (2) (69) (6) (2) (13) (152) (17) (16)
6

All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA

BULLETIN RG-1
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
© Ashcroft Inc. 2016 08/16 email: [email protected] • www.ashcroft.com