Product: WHEEL LOADER
Model: 992G WHEEL LOADER AZX00534
Configuration: 992G Wheel Loader AZX00001-UP (MACHINE) POWERED BY
3508B Engine
i02072779
S/N - AZX1-UP
Calibration of the lift linkage position sensor must be performed after any of the following events
occur:
• The sensor mount, the lift cylinder, or the lift linkage are disturbed.
Note: The messages that appear on the diagnostic message screen may differ from the messages that
are listed in this procedure.
Reference: For more information on messages that appear on the diagnostic message screen, refer to
the "Calibration Messages" section of Testing and Adjusting, "Glossary of Terms" in this manual.
1. Park the machine on a smooth, level surface. Also, the area must be clear so that the bucket can
be fully raised and fully lowered. The machine must be clear of all machines and personnel.
Illustration 1 g00284487
Right Console
(1) Keypad.
Illustration 2 g00286975
Front Dash
6. Press the "OK" key on keypad (1) repeatedly in order to clear any error messages that are
flashing on the display. Press the "OK" key on keypad (1) repeatedly until the hour meter
appears on diagnostic message screen (2) .
7. On the keypad, enter "SERV (7378)" and then press the "OK" key. Press the ">" key until
"LIFT LINK SNSR - CAL" is displayed on the bottom line of the diagnostic message screen.
Table 1
"SELECT CALIBRATION"
"LFT LINK SNSR - CAL"
8. The "LFT LINK SNSR - CAL" message will be displayed on the diagnostic message screen
(2). Press "OK" in order to start the calibration. All the instructions for the calibration will be
displayed on the screen.
Table 2
"LFT LINK SNSR - CAL"
"PRESS [OK] TO START"
9. In this step, raise the boom to the end of travel. Then, press the "OK" key.
Table 3
"RAISE BOOM FULLY"
"THEN PRESS [OK]"
10. In this step, extend the lift cylinders to the full RAISE position. Then press the "OK" key.
Table 4
"EXTND LFT CYLS FULLY"
"THEN PRESS [OK]"
11. If the screen displays "RESULTS OK", proceed to the next step. If the calibration has failed,
proceed to Step 17.
Table 5
"RESULTS OK"
12. In this step, position the bucket to the full TILT BACK position. Then, press the "OK" key.
Table 6
"TILT BKT BACK FULLY"
" THEN PRESS [OK]"
13. Lower the lift linkage to the full LOWER position. Then, press the "OK" key.
Table 7
"LOWER BOOM FULLY"
" THEN PRESS [OK]"
14. Ensure that the lift cylinders are at the end of travel at the LOWER position. Then press the
"OK" key.
Table 8
"BOTTOM OUT LIFT CYLS"
" THEN PRESS [OK]"
15. If the screen displays "RESULTS OK", proceed to Step 19. If the calibration has failed, proceed
to Step 18.
Table 9
"RESULTS OK"
16. If the calibration passes, the screen displays "CALIBRATION COMPLETED OK". Proceed to
Step 19.
Table 10
"CALIBRATION"
"COMPLETED OK"
17. If the calibration has failed, the screen displays "CALIBRATION FAILED". Press the "OK"
key for the reason of the failure.
Table 11
"CALIBRATION FAILED"
"PRESS [OK] FOR REASON"
a. If the screen displays "LIFT LINKAGE SNSR ERR", the problem is with the sensor
circuit. The lift linkage position sensor has one of the following conditions. no signal,
wrong frequency, out of calibration and wiring problem. The problem must be repaired
before the calibration can be completed. The display will advance. Then, press the "OK"
key in order to acknowledge the error.
Table 12
"LIFT LINK SNSR ERR"
"CHECK SNSR/CAL/WIRING"
Table 13
"PRESS [OK]"
"TO ACKNOWLEDGE"
b. When the display shows "SENSOR ABOVE RANGE", the calibration indicates that the
percent of duty cycle is above the specification. The lift linkage may not be moved to the
correct range. The display will advance. Then, press the "OK" key in order to
acknowledge the error.
Table 14
"SENSOR ABOVE RANGE"
"(65.0) XXX.X (92.0)"
Table 15
"PRESS [OK]"
"TO ACKNOWLEDGE"
c. When the display shows "SENSOR BELOW RANGE", the calibration indicates that the
percent of duty cycle is below the specification. The lift linkage may not be moved to the
correct range. The display will advance. Then, press the "OK" key in order to
acknowledge the error.
Table 16
"SENSOR BELOW RANGE"
"(65.0) XXX.X% (92.0)"
Table 17
"PRESS [OK]"
"TO ACKNOWLEDGE"
18. If the calibration has failed, the screen will display "CALIBRATION FAILED". Press the "OK"
key for the reason of the failure.
Table 18
"CALIBRATION FAILED"
"PRESS [>] FOR REASON"
a. If the screen displays "LIFT LINKAGE SNSR ERR", the problem is with the sensor
circuit. The lift linkage position sensor has one of the following conditions. no signal,
wrong frequency, out of calibration and wiring problem. The problem must be repaired
before the calibration can be completed. The display will advance. Then, press the "OK"
key in order to acknowledge the error.
Table 19
"LIFT LINK SNSR ERR"
"CHECK SNSR/CAL/WIRING"
Table 20
"PRESS [OK]"
"TO ACKNOWLEDGE"
b. When the display shows "SENSOR ABOVE RANGE", the calibration indicates that the
percent of duty cycle is above the specification. The tilt linkage may not be moved to the
correct range. The display will advance. Then, press the "OK" key in order to
acknowledge the error.
Table 21
"SENSOR ABOVE RANGE"
"8.0 XXX.X% (45.0)"
Table 22
"PRESS [OK]"
"TO ACKNOWLEDGE"
c. When the display shows "SENSOR BELOW RANGE", the calibration indicates that the
percent of duty cycle is above the specification. The tilt linkage may not be moved to the
correct range. The display will advance. Then, press the "OK" key in order to
acknowledge the error.
Table 23
"SENSOR ABOVE RANGE"
"8.0 XXX.X% (45.0)"
Table 24
"PRESS [OK]"
"TO ACKNOWLEDGE"
19. After three seconds, the screen will display "EXITING CALIBRATION". After three seconds,
exit the calibration.
Table 25
"EXITING"
"CALIBRATION"