0% found this document useful (0 votes)
78 views2 pages

Nanda Archwires: Science Does Matter!

This document describes and provides information on several archwire products from Nanda Archwires, including Nanda BT3 Beta Titanium archwires, Nanda Braided Copper-Nickel-Titanium archwires, and Nanda BT3 Intrusion Arch. The archwires have properties that provide benefits such as superior formability, reduced treatment time, and effective torque control. Clinical instructions are provided for uses of the archwires.

Uploaded by

aung Naingmyo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views2 pages

Nanda Archwires: Science Does Matter!

This document describes and provides information on several archwire products from Nanda Archwires, including Nanda BT3 Beta Titanium archwires, Nanda Braided Copper-Nickel-Titanium archwires, and Nanda BT3 Intrusion Arch. The archwires have properties that provide benefits such as superior formability, reduced treatment time, and effective torque control. Clinical instructions are provided for uses of the archwires.

Uploaded by

aung Naingmyo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Nanda Archwires

Science does matter!

www.forestadent.com
Nanda BT3 Beta Titanium
Developed together with Prof. Dr. Ravindra Nanda (Connecticut, USA), NBT3 archwires are the latest generation of Beta Titanium
archwires. The perfect wire for mid to finishing stages of treatment.
Outstanding characteristics for better and faster results:
• Superior formability, optimized with increased ductility to enable the
most intricate bending without breakage • Polished wire surface to reduce the treatment time with smoother
• Modulus of elasticity 60-65% less than stainless steel, provides twice finish for improved sliding mechanics
the working range when compared to stainless steel • Safe for use on nickel-sensitive patients

Description Order No. Profile ø mm ø inch Content

285-2040 0,40 x 0,56 .016“ x .022“ 10


285-2043 0,43 x 0,64 .017“ x .025“ 10
285-2046 0,46 x 0,64 .018“ x .025“ 10
Nanda BT3 Beta Titanium
285-2048 0,48 x 0,64 .019“ x .025“ 10
285-2053 0,53 x 0,64 .021“ x .025“ 10
285-2440 0,40 x 0,64 .016“ x .025“ 10

Nanda Braided Copper-Nickel-Titanium


Natural Form
Nanda Braided CuNiTi wires provide a lower stiffness, remarkable flexibility and the ease of ligation. They are slotfilling and enable an effective torque
control. Near constant clinical forces are maintained for a long­er period which results in faster tooth movement with less archwire changes. It comes
with the enhanced features found only in copper-nickel-titanium archwires.

Indications:
• Initial stages of treatment to unravel, align and level
• Providing torque control and full slot engagement
• Finishing wire to achieve and retain torque Natural Form

Description Order No. Max. Order No. Mand. Profile ø mm ø inch Content

200-2043 200-2143 0,43 x 0,64 .017“ x .025“ 10


Nanda Braided Copper-Nickel-Titanium
200-2054 200-2154 0,53 x 0,64 .021“ x .025“ 10

Nanda BT3 Intrusion Arch


The intrusion arch is inserted into the molar tubes with the pre-activated 30° V-bends 2-3 mm mesial to the molar tubes so that the wire lies passively
on the vestibular sulcus. Activation is accomplished by bringing it occlusal and tying it to the anterior segment attached to the four incisors. An in-
trusive force of 40 – 50 grams is applied on the incisors while at the same time the molars and / or the buccal segment undergo a reciprocal extrusive
force and a distal crown moment. This moment can help in correcting edge to edge class II to class I molar relationship.

Indications:
• Incisor intrusion • Correction of minor open bite (Incisor Extrusion)
• Simultaneous Class II molar • Correction of anterior occlusal cant
correction • Preventing the side effects associated with canine retraction
• Incisor flaring

Description Order No. Max. Order No. Mand. Profile ø mm ø inch Content

284-2040 284-2140 0,40 x 0,56 .016“ x .022“ 3


Nanda BT3 Intrusion
284-2043 284-2143 0,43 x 0,64 .017“ x .025“ 3

Clinical Pearl
By using Duo Force wires, initial alignment can be achieved in 8 to 10 weeks in moderately crowded arches. NBT3 rectangular wires can be used
next to express torque and angulation very early in treatment. Non extraction patients can easily be finished in one year with only use of 3 to 4 wires
in each arch. Intervals be­tween appointments can also be entended to 6-8 weeks or longer. A prime example of accelerated orthodontic treatment!

- Prof. Dr. Ravindra Nanda (Connecticut, USA)

Info No. 213/03.2020 FORESTADENT Bernhard Förster GmbH • Westl. Karl-Friedrich-Str. 151 • 75172 Pforzheim • Germany • Phone: +49 (0) 7231 459-0 • Fax: +49 (0) 7231 459-102 • [email protected]

You might also like