The document provides information and instructions for calculating seismic load according to the Egyptian Code of Practice 201-2012. It gives an example calculation for a 28m high building and determines the base shear force and scaling base shear. It also provides the response spectrum curve for the given seismic zone and soil type.

Uploaded by

Ahmed Ewis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
523 views16 pages

Egyptian Response Spectrum: According To The ECP 201-2012

The document provides information and instructions for calculating seismic load according to the Egyptian Code of Practice 201-2012. It gives an example calculation for a 28m high building and determines the base shear force and scaling base shear. It also provides the response spectrum curve for the given seismic zone and soil type.

Uploaded by

Ahmed Ewis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 16

Egyptian Response Spectrum©

according to the ECP 201-2012

Ver. 2.0

Please send your comments & suggestions to improve this tool on


[email protected]

by
Mahmoud M. El-Kateb, Ph.D

Structural Engineering Dept.


Faculty of Engineering - Ain Shams University
According to ECP 201-2012 By: Dr. Mahmoud El-Kateb
Version 1.9

* Calculation of Seismic load

* Project :

Building Data:
Total height of building above foundations 28 m
Total dead load of building 54,740 kN
Total live load of building 8,540 kN
Building importance gI 1.00 Normal building
Building damping factor h 1.00 Reinforced concrete
Response modification factor R 5.0
Building is in area of type 1 Response spectrum curve
Building in seismic zone 3 ag = 0.15 g
Type of soil beneath C S TB TC TD
1.50 0.10 0.25 1.20

Natural period of building:


Ct = 0.075 Concrete space frames
T = 0.913 Sec. Simplified Response Spectrum method can be used

Sd (T) = 0.031 g

Earthquake force:
Live load ratio y = 0.25 Residential structures
Weight of building = 56,875 kN
Correction factor l = 1.00

Fb = 0.031 W @ 3.1% of vertical load

Fb = 1752 kN Base shear force

Scaling base shear = 1489 kN (85% of Base shear force)


According to ECP 201-2012 By: Dr. Mahmoud El-Kateb
Version 2.0

* Response Spectrum curve

* Project :

Building Data:
Total height of building above foundations 28 m
Total dead load of building 54,740 kN
Total live load of building 8,540 kN
Building importance gI 1.0 Normal building
Building damping factor h 1.0 Reinforced concrete
Response modification factor R 5.0
Building is in area of type 1 Response spectrum curve
Building in seismic zone 3 ag = 0.15 g
Type of soil beneath C S TB TC TD
1.50 0.10 0.25 1.20

Natural period of building:


Ct = 0.075
T = 0.913 Sec. Simplified Response Spectrum method can be used

Response Spectrum values:

T (S) 0.000 0.033 0.067 0.100 0.150 0.200 0.250 0.440 0.630
Sd (m/s2) 1.4715 1.3489 1.2263 1.1036 1.1036 1.1036 1.1036 0.6271 0.4379
T (S) 0.820 1.010 1.200 1.667 2.133 2.600 3.067 3.533 4.000
Sd (m/s ) 0.3365 0.2943 0.2943 0.2943 0.2943 0.2943 0.2943 0.2943 0.2943
2

at T = 0.913 sec , Sd = 0.3022 m/s2


at any T = 1.8 sec Sd = 0.2943 m/s2
Response Spectrum curve
Acceleration (m/sec2)

1.60

1.40

1.20

1.00

0.80

0.60

0.40

0.20

0.00
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00
Time (Sec.)

Type 1 - Seismic zone (3) - Soil type (C) , gI = 1.0 , h = 1.0 , R = 5.0