Clamp Meters: Readings You Can Rely On
Clamp Meters: Readings You Can Rely On
CLAMP METERS
Log and trend measurements to pinpoint intermittent faults
The Fluke 376 FC True-rms Clamp Meter is your go-to tool for an extremely wide range
of electrical measurements.
• Connect your meter to your smartphone and provides access to large conductors
with Fluke Connect™ Measurements in tight spaces (included)
• Read measurements on your phone at a • TPAK magnetic hanging strap (included)
safe distance, wearing less PPE while • Integrated VFD low-pass filter for accu-
your meter takes all the risks rate motor drive measurements
• Record results directly to your phone • Proprietary inrush measurement tech-
and the cloud nology to filter out noise and capture
• Capture intermittent faults while per- motor starting current exactly as the
forming other tasks using the logging circuit protection sees it
capabilities of the Fluke 376 FC • CAT IV 600 V, CAT III 1000 V safety
• Create and share reports from the field rating
via email, or converse in real time with • Three-year warranty
ShareLive™ video calls • Soft carrying case
• The iFlex flexible current probe expands
the measurement range to 2500 A ac
Clamp Meters 11
CLAMP METER SELECTION GUIDE
Low-pass filter • •
Harmonics, power,
data logging
18” iFlex Flexible Optional Optional Included Included
Current Probe
10” iFlex Flexible Optional Optional Optional Optional
Current Probe
Remote display Detachable Detachable
with cable magnetic
Flashlight/torch •
Display
Display hold • • • • • • • • •
Backlight • • • • • • • •
Specifications
Jaw opening 30 mm (1.18”) 30 mm (1.18”) 30 mm (1.18”) 34 mm (1.33”) 34 mm (1.33”) 18 mm (.7”) 34 mm (1.33”) 34 mm (1.33”) 30.5 mm (1.2”)
Current range ac rms 0 to 400.0 A 0 to 400.0 A 0 to 400.0 A 0 to 600.0 A 0 to 600.0 A 0 to 200.0 A 0 to 999.9 A 0 to 999.9 A 0 to 600.0 A
Accuracy ac current 2% 2% 2% 2% 2% 2% 2% 2% 2%
(50/60 Hz) ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts
AC response True-rms True-rms True-rms True-rms True-rms True-rms True-rms True-rms True-rms
Current range dc 0 to 400.0 A 0 to 400.0 A 0 to 600.0 A 0 to 600.0 A 0 to 200.0 A 0 to 999.9 A 0 to 999.9 A 0 to 200 μA
Accuracy dc current 2% 2% 2% 2% 2% 2% 2% 1%
± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts
Voltage range ac 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 1000 V 600.0 V 0 to 1000 V 0 to 1000 V 0 to 1000 V
Accuracy ac voltage 1.5 % 1.5 % 1.5 % 1.5 % 1.5 % 1.5 % 1.5 % 1.5 % 1.5 %
± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts
Voltage range dc 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 1000 V 0 to 1000 V 600.0 V 0 to 1000 V 0 to 1000 V 0 to 600.0 V
Accuracy dc voltage 1% 1% 1% 1% 1% 1.5 % 1% 1% 1%
± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts
Resistance range 0 to 4000 Ω 0 to 4000 Ω 0 to 40.00 kΩ 0 to 6000 Ω 0 to 60 kΩ 0 to 6000 Ω 0 to 60 kΩ 0 to 60 kΩ 0 to 60 kΩ
Frequency measurement 500 Hz 500 Hz 500 Hz 500 Hz
range
Unit power
Auto off • • • • • • • • •
Warranty and safety
Warranty (years) 2 2 2 3 3 3 3 3 3
Category ratings CAT III 600 V, CAT III 600 V, CAT III 600 V, CAT III 1000 V, CAT III 1000 V, CAT III 600 V CAT III 1000 V, CAT III 1000 V, CAT III 600 V,
(EN61010-1) CAT IV 300 V CAT IV 300 V CAT IV 300 V CAT IV 600 V CAT IV 600 V CAT IV 600 V CAT IV 600 V CAT IV 300 V
12 Clamp Meters
CLAMP METERS
iFlex
High-end industrial/utility Leakage
accessory *
i2500-10/
345 353 355 368 FC 369 FC
Models i2500-18
Measurements
AC current • • • • • •
AC volts • •
Resistance •
Continuity •
DC volts • •
DC current • • •
True-rms • • • • •
Frequency • • • •
AC + DC voltage •
AC + DC current • •
Min/max/avg • • • • •
Temperature
Capacitance
Special features
Fluke Connect™ enabled • •
Inrush current mode • • • •
Low-pass filter • •
Harmonics, power, •
data logging
18” iFlex Flexible
Current Probe
10” iFlex Flexible
Current Probe
Remote display
Flashlight/torch •
Display
Display hold • • • •
Backlight • • • • •
Specifications
Jaw opening 60 mm (2.36”) 58 mm (2.28”) 58 mm (2.28”) 7.5 mm (.59”)coil 40 mm (1.57”) 61 mm (2.40”)
Current range ac rms 0 to 1400 0 to 1400 A 0 to 1400 A 0 to 2500 A 0 to 60 A 0 to 60 A
Accuracy ac current 3% 1.5 % 1.5 % 3% 1% 1%
(50/60 Hz) ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts ± 5 counts
AC response True-rms True-rms True-rms True-rms True-rms True-rms
Current range dc 0 to 2000 0 to 2000 A 0 to 2000 A
Accuracy dc current 1.5 % 1.5 % 1.5 %
± 5 counts ± 5 counts ± 5 counts
Voltage range ac 0 to 825 V 0 to 600.0 V
Accuracy ac voltage 3% 1%
± 5 counts ± 5 counts
Voltage range dc 0 to 825 V 0 to 1000 V
Accuracy dc voltage 1% 1%
± 5 counts ± 5 counts
Resistance range 0 to 400 kΩ
Frequency measurement 15 Hz to 1 kHz 5 to 1000 Hz 5 to 1000 Hz 500 Hz
range
Unit power
Auto off • • • •
Warranty and safety
Warranty (years) 3 3 3 1 1
Category ratings CAT IV 600 V CAT III 1000 V, CAT III 1000 V, CAT III 1000 V, CAT III 600 V CAT III 600 V
(EN61010-1) CAT IV 600 V CAT IV 600 V CAT IV 600 V
*
Clamp not included
Clamp Meters 13