IKHWAN HANAFI 1315213056: Results Data
IKHWAN HANAFI 1315213056: Results Data
Results Data
Pipe Flow Software - Project 1 - PF Expert Solution 05 October, 2015
Color of Pipe: Flow Rate in m³/sec Pipe Flow Expert Results Key
0.0 0.0 0.0 0.0 0.0 0.0 f = flow in m³/sec
P8, f=0.0134
P6, f=0.0247
N5 14.0m N4 14.0m
0.0 bar.g@ 2.0m 0.0 bar.g@ 2.0m
0.1957 bar.g 0.1000 m³/sec 0.1957 bar.g
N1 0.0m
0.0 bar.g@ 8.0m
0.7830 bar.g
Fluid Data
Zone Fluid Name Chemical Temperature Pressure bar.g Density kg/m³ Centistokes Centipoise Vapour State
Formula °C Pressure bar.a
Pump Data
Pipe Id Pipe Pump Speed Pref. Op Pref. Op Flow Velocity Suction Discharge Pump Pump Pump Pump Pump
Name Name rpm From To In/Out m/sec Pressure Pressure Head (+) NPSHr NPSHa Efficiency Power
m³/sec m³/sec m³/sec bar.g bar.g m.hd m.hd m.hd Percentag Kilowatts
Fluid (absolute) (absolute) e
1 P1 Pump Set Flow 0.0000 0.017 0.7829 69.1175 698.215 Not 18.108 Not Not
Rate known known Known
Pipe Data
Pipe Id Pipe Name Material Inner Roughness Length m Total K Mass Flow Flow m³/sec Velocity Entry Exit
and Notes Diameter mm kg/sec m/sec Pressure Pressure
mm bar.g bar.g
1 P1 1" Steel 26.645 0.046 10.000 0.4600 0.0094 0.0000 0.017 0.7830 69.1175
(ANSI) Sch.
40
2 P2 1" Steel 26.645 0.046 4.000 1.3800 25.4215 0.0255 *45.682 69.1175 19.2929
(ANSI) Sch. (Flow
40 Velocity is
high)
3 P3 1" Steel 26.645 0.046 2.000 0.0000 25.4215 0.0255 *45.682 19.2929 0.1957
(ANSI) Sch. (Flow
40 Velocity is
high)
4 P4 4" Steel 102.260 0.046 3.048 0.6900 49.7797 0.0499 *6.073 69.1175 68.8964
Sch. 40 (Flow
Velocity is
high)
5 P5 1" Steel 26.645 0.046 2.000 0.0000 49.7797 0.0499 *89.454 68.8964 0.1957
(ANSI) Sch. (Flow
40 Velocity is
high)
6 P6 1" Steel 26.645 0.046 4.000 2.3000 24.6082 0.0247 *44.221 69.1175 13.4443
(ANSI) Sch. (Flow
40 Velocity is
high)
7 P7 1" Steel 26.645 0.046 4.000 0.6900 13.3777 0.0134 *24.040 13.4443 1.5708
(ANSI) Sch. (Flow
40 Velocity is
high)
8 P8 4" Steel 102.260 0.046 2.000 0.0000 13.3777 0.0134 1.632 1.5708 0.1957
Sch. 40
9 P9 1" Steel 26.645 0.046 4.000 0.6900 11.2306 0.0113 *20.181 13.4443 5.0579
(ANSI) Sch. (Flow
40 Velocity is
high)
10 P10 1" Steel 26.645 0.046 2.000 0.0000 11.2306 0.0113 *20.181 5.0579 0.1957
(ANSI) Sch. (Flow
40 Velocity is
high)
Node Data
Node Id Node Type Node Elevation m Liquid Level Surface Press. at HGL at Demand In Demand Total Flow Total Flow
m Press. bar.g Node bar.g Node m.hd m³/sec Out m³/sec In m³/sec Out m³/sec
Fluid
1 Tank N1 0.000 8.000 0.0000 0.7830 8.000 N/A N/A 0.0000 0.0000
2 Tank N2 10.000 2.000 0.0000 0.1957 12.000 N/A N/A 0.0499 0.0000
3 Tank N3 14.000 2.000 0.0000 0.1957 16.000 N/A N/A 0.0255 0.0000
4 Tank N4 14.000 2.000 0.0000 0.1957 16.000 N/A N/A 0.0134 0.0000
5 Tank N5 14.000 2.000 0.0000 0.1957 16.000 N/A N/A 0.0113 0.0000
6 Join Point N6 0.000 N/A N/A 69.1175 706.214 0.1000 0.0000 0.1000 0.1000
7 Join Point N7 0.000 N/A N/A 19.2929 197.127 0.0000 0.0000 0.0255 0.0255
8 Join Point N8 0.000 N/A N/A 68.8964 703.955 0.0000 0.0000 0.0499 0.0499
9 Join Point N9 0.000 N/A N/A 13.4443 137.368 0.0000 0.0000 0.0247 0.0247
10 Join Point N10 0.000 N/A N/A 1.5708 16.050 0.0000 0.0000 0.0134 0.0134
11 Join Point N11 0.000 N/A N/A 5.0579 51.680 0.0000 0.0000 0.0113 0.0113
Energy Data
Pipe Id Pipe Name Energy Loss Energy Loss Energy Loss Energy Loss Energy Loss SUBTOTAL Energy Loss Energy Loss TOTAL USED
To Pipe To Pipe To Pipe To Pipe To Pump Loss Pipe To Discharge To Change in Sum of All
Friction Fittings Components Control Inefficiency Items +Pump Pressure Elevation Items
Valves
Kilowatts Kilowatts Kilowatts Kilowatts Kilowatts Kilowatts Kilowatts Kilowatts Kilowatts
1 P1 0.000000 0.000000 0.000000 0.000000 Efficiency Not 0.000000 0.000000 0.000000 0.000000
Specified
2 P2 90.309688 36.605625 0.000000 0.000000 N/A 126.915313 0.000000 0.000000 126.915313
10 P10 3.929572 0.000000 0.000000 0.000000 N/A 3.929572 0.220268 1.541879 5.691719