Standard Shock Pulse Transducers: Ordering Numbers
Standard Shock Pulse Transducers: Ordering Numbers
A M8 /
UNC 5/16"
46.5 4 11 17
61.5
B
ø 11
46.5 58 11
115.5
A shock pulse transducer converts the shock pulses emitted SPM 93022
by the bearing into electric signals. A coaxial cable connects
the transducer with a measuring terminal or measuring de-
vice. Max. cable length is 4 m.
Ordering numbers
40000 Standard shock pulse transducer, M8 x1.25
40100 Standard shock pulse transducer, UNC 5/16-18
40001 Standard shock pulse transducer,
M8 x1.25, extended
40101 Standard shock pulse transducer, Mounting tools
UNC 5/16 - 18, extended 82053 Countersink with fixed pilot for M8
81027 Holder for countersink
Technical data 81028 Countersink, angle 90°, 12 mm dia.
Measuring range Max. 100 dBsv 81031 Pilot for M8
Housing, base Stainless acid proof steel, 81032 Pilot for UNC 5/16"
Sandvik Grade:1802, EN:1.4523
To drill the mounting hole, use drill bits 6.9 mm for M8, 6.6
Design Sealed
mm for UNC5/16".
Connector tightness IP65 with TNC connector
IP 67 with conn. SPM13008 Torque and unscrew the transducer with a torque wrench
Temperature range -30° C to +150° C and a long 17 mm socket (SPM 81086).
External overpressure Max. 1 MPa (10 bar)
Mounting torque 15 Nm, max. 20 Nm
Connector TNC jack
Weight: 55 g
SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • [email protected] • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2013-06. TD-004 B Rev.0