PCD1 System-Catalogue Controls
PCD1 System-Catalogue Controls
Automation
powerful CPU.
stations
The many communication options are another advantage:
Ethernet TCP/IP, USB port, the onboard RS-485 interface and the expansion options with BACnet® or LON IP, for instance, are a small
1
example of the performance capability of PCD1.
HMI Visualization
Page 54
and operating
Saia PCD1.M2xxx are compact
and may be modular extended.
2
` PCD1.M2020 without Ethernet TCP/IP
18 integrated I/Os
2 free I/O slots
Possible use in
primary switch cabinet
room controller
Dedicated
1.4.2 Saia PCD1.Room (PCD1. M2110R1) Page 58
3
of room automation and HeaVAC.
24 integrated I/O
1 free I/O slot
18 integrated I/Os
no free I/O slots
components
Cabinet
Possible use in a
electrical cabinet
5
The Saia PCD1.M2xxx series is a compact controller with onboard I/Os and in addition two I/O-slots
for PCD2 I/O-modules or communication interface-modules. The Web/IT functionality, the onboard
memory, the range of standard communication interfaces and the expansion options offer good solu-
tions for small to medium installations.
Automation Server
SNMP
Slot for integrated in
M1 memory the base unit
X3 modules
Slot for communica- and com-
tion interfaces munica-
Slot A
tion
Battery
Operational LEDs
RUN/STOP button
USB port
X2 X1 X0
Ethernet connection
(2 port switch)
Types
` PCD1.M2160 with Ethernet TCP/IP
Terminals for integral
and expanded memory
` PCD1.M2120 with Ethernet TCP/IP
inputs and outputs
Terminals for optional
` PCD1.M2020 without Ethernet TCP/IP
connection (slot A)
Supply
1.5mm2 / max. 25 cm
Earthing bar
142 49
On a flat surface On two top-hat rails Further information is provided in the Saia PCD3 power
(2 × 35 mm pursuant to supply and connection plan section and in Manual 26-875.
DIN EN 60 715 TH35)
Technical data
Automation
stations
Memory and file system Types: PCD1.M2160 PCD1.M2120 PCD1.M2020
1
Program memory, DB/text (Flash) 1 MByte 512 kByte 512 kByte
Integrated communication
Ethernet connection (2 port switch)
HMI Visualization
yes yes no
10/100 Mbit/s, full-duplex, auto-sensing, auto-crossing
and operating
USB connection
USB 1.1 device, 12 Mbit/s
yes yes yes
RS-485
(terminal X3), up to 115 kbit/s
yes yes yes
General data
2
Supply voltage 24 VDC, –20/+25 % max. incl. 5% ripple (according to EN/IEC 61131-2)
Battery for data backup (exchangeable) Lithium battery with a service life of 1 to 3 years
Operating temperature 0…55 °C
Dimensions (W × H × D) 142 × 226 × 49 mm
Type of mounting 2× top-hat rails according to DIN EN60715 TH35 (2 × 35 mm) or on a flat surface
Protection level IP 20
Capacity 5V/+V(24 V) internal max. 500 mA/200 mA
room controller
Power consumption typically 12 W
Dedicated
On-Board inputs/outputs
Inputs
6 Digital inputs (4 + 2 interrupts) 15…30 VDC, 8 ms / 0.2 ms input filter Terminal X1
3
2 Analog inputs, selectable via DIP switch –10…+10 VDC, 0…+/–20 mA, Pt1000, Ni1000, Ni1000 L&S, 0…2.5 kΩ, Terminal X1
12 bit resolution
Outputs
4 Digital outputs 24 VDC / 0.5 A Terminal X0
1 PWM output 24 VDC / 0.2 A Terminal X0
Consumption data
4 Digital inputs or outputs 24 VDC / data as digital inputs resp. outputs Terminal X0
1 Watchdog relay or make contact 48 VAC or VDC, 1 A
Terminal X3 acquisition
mount a free wheeling diode over the load when switching DC-tension
PCD1 CPU (PCD1.M2xxx, PCD1.M0160E0, PCD1.M2110R1 ). It can be plugged in the slot A instead of a commu-
nication interface.
*) In preparation, see section C2 Product status
I/O 0 I/O 1
components
Cabinet
In addition to the onboard interfaces, the interface functions can also be extended in a modular way by
M1
means of the various slots. Numerous protocols are therefore supported by the Saia PCD1.M2 series. X3
Detailed information and an overview can be found in the section BA communication systems. Slot A
X2 X1 X0
Current draw
Current draw
on 5V bus on +V bus Slot
Communication (24V)
PCD7.F110S RS-485/RS-422 not electrically isolated 40 mA – Slot A
PCD7.F121S RS-232 with RTC/CTS, DTR/DSR, DCD suitable for modem, 15 mA
EIB connection
– Slot A
Memory modules
The onboard memory of the Saia PCD1.M2xxx can be extended by means of a Saia PCD7.Rxxx module in slot M1. In ad-
dition, the Saia PCD1.M21x0 can be extended with BACnet® IP or LON IP.
More information about the memory management and construction are listed in Chapter 1.1 Saia PCD® basic properties.
Labeling
The self-adhesive labels can be printed directly with the
SBC LabelEditor from the PG5 Device Configurator
Automation
stations
1
EPLAN macros
For project planning and engineering ePLAN® electric P8 macros are available from the
EPLAN macros are available. support page.
Macros and product data may also be obtained
from the ePLAN® data portal.
HMI Visualization
and operating
Battery for data backup
Type Description
2
4 507 4817 0 Lithium battery for PCD processor unit (RENATA button battery type CR 2032)
room controller
Cover
Dedicated
4 104 7759 0 Housing cover for PCD1.M2xxx without logo
can be individually designed on site with a foil
3
Consumption data
Range of uses
` For small and medium installations with a minimum risk through the expandability and programmability
acquisition
` Modernization and enhancement of existing installations through the compact design, for example
` Various interface options, including to existing installations as a gateway.
For example, optimization of a cooling system by setting all the free parameters
4
components
Cabinet
Saia PCD1.Room (PCD1.M2110R1) is a programmable room controller for sophisticated solutions with
many communication options. In addition to the I/Os that are already integrated, the controller offers a free I/O
slot for an individual expansion with inputs/outputs or communication options. Web/IT functions for mobile
operation, for instance, are also already onboard.
Furthermore, Saia PCD1.Room offers various possibilities for integrating other systems in the room through stand-
ard communication interfaces. (Energy) efficient and individual room automation can be easily implemented as a
result.
The controller also provides a good basis for achieving the energy efficiency classes according to EN 15232:2012.
USB port
Ethernet connection
(2 port switch) e.g. to the Inter-
net (remote control via browser
is possible as a result)
Lighting, sun blinds and single room control can be optimally harmonized with this controller. This example showing possible assignments was compiled on the
basis of applications according to the VDI 3813 list of room automation functions and the DIN EN 15232 list of building automation functions.
Supply
1.5mm2 / max. 25 cm
Earthing bar
Technical data
Memory and file system Type: PCD1.M2110R1
Program memory, DB/text (Flash) 256 kByte
Automation
User memory, DB/text (Flash) 128 kByte
stations
User flash file system onboard 8 MByte
Integrated communication
Ethernet connection (2 port switch) 10/100 Mbit/s, full-duplex, auto-sensing, auto-crossing yes
1
USB connection USB 1.1 device, 12 Mbit/s yes
RS-485 (terminal X3), up to 115 kbit/s yes
General data
Supply voltage 24 VDC, –20/+25 % max. incl. 5% ripple (according to EN/IEC 61131-2)
Battery for data backup (exchangeable) Lithium battery with a service life of 1 to 3 years
HMI Visualization
Operating temperature 0…55 °C
and operating
Dimensions (W×H×D) 142 × 226 × 49 mm
Type of Mounting 2× top-hat rails according to DIN EN60715 TH35 (2 × 35 mm) or on a smooth surface
Protection type IP 20
Capacity 5V/+V(24V) internal max. 500 mA/200 mA
Power consumption typically 12 W
2
Automation Server Flash memory, Filesystem, FTP and Web-Server, E-Mail, SNMP
Automation Server
SNMP
integrated in
the base unit
On-Board inputs/outputs
Inputs
6 Digital inputs (4 + 2 interrupts) 15…30 VDC, 8 ms / 0.2 ms input filter Terminal X1
room controller
2 Analog inputs, selectable via DIP switch –10…+10 VDC, 0…+/–20 mA, Terminal X1
Pt1000, Ni1000, Ni1000 L&S, 0…2.5 kΩ, 12 Bit resolution
Dedicated
4 Analog inputs, selectable via DIP switch 0…10 VDC, 0(4)…20 mA, Pt1000, Pt 500, Ni1000
14 Bit resolution EA 1
Outputs
3
4 Digital outputs 24 VDC / 0.5 A Terminal X0
1 PWM output 24 VDC / 0.2 A Terminal X0
2 Analog outputs, selectable via PG5 0…10 VDC or 0(4)…20 mA, 12 Bit resolution EA 1
Consumption data
Analogue output module Saia PCD7.W600 *) acquisition
This new analogue outputs (range 0 to +10 V) with 12 bits resolution has been especially developed for the new
PCD1 CPU (PCD1.M2xxx, PCD1.M0160E0, PCD1.M2110R1 ). It can be plugged in the slot A instead of a commu-
nication interface.
*) In preparation, see section C2 Product status
4
The modules that have already been listed in the PCD2.M5 series are used for the Saia PCD1 series.
I/O 0 I/O 1
components
Only a PCD2.W525 module that is already supplied together with the controller in the default set up works in slot I/O 1.
If the module is removed, the controller stops.
5
In addition to the onboard interfaces, the interface functions can also be extended in a modular way by
M1
means of the various slots. Numerous protocols are therefore supported by the Saia PCD1.M2110R1. X3
A detailed list of all the protocols can be found in the section BA communication systems. Slot A
X2 X1 X0
Memory modules
The onboard memory can be extended by means of a PCD7.Rxxx module in slot M1. In addition, BACnet® IP or LON IP
can be activated.
For more information about memory management and construction, see Chapter 1.1 Saia PCD® System description.
Labeling
The self-adhesive labels can be printed directly with the
SBC LabelEditor from the PG5 Device Configurator
Automation
stations
1
EPLAN macros
For project planning and engineering ePLAN® electric P8 macros are available from the
EPLAN macros are available support page.
Macros and product data may also be obtained
from the ePLAN® data portal.
HMI Visualization
and operating
Battery for data backup
Type Description
4 507 4817 0 Lithium battery for PCD processor unit (RENATA button battery type CR 2032)
2
Plug-in screw terminal blocks
4 405 5089 0 Plug-in screw terminal block, 11-pole, labeling 0…10 Terminal X0
4 405 5087 0 Plug-in screw terminal block, 9-pole, labeling 11…19 Terminal X1
4 405 5088 0 Plug-in screw terminal block, 10-pole, labeling 20…29 Terminal X2
Cover
4 104 7759 0 Housing cover for PCD1.M2xxx without SBC-Logo
room controller
can be individually designed on site with a foil
Dedicated
3
Range of uses
Applications should be examined closely taking account of the number of I/Os. Depending on the application, coupling
components
relays (for example: PCD7.L252) or S-Bus RIOs (PCD7.L200/L210) may be required. The S-Bus and Modbus stations are limited
to a maximum of 10 units.
Cabinet
The freely programmable E-Controller (PCD1.M0160E0) is a compact controller with a factory pre-load-
ed S-Monitoring application. For more about S-Monitoring and the loaded application, see below under
Chapter 4 „S-Monitoring“, section 4.8 „E-Controller“. Designed for compatibility with an electrical control
box, the E-Controller is suitable for installation in a power distribution unit or any restricted space. In
addition to integral I/Os, interfaces and web/IT functions, the PCD1.M0160E0 offers further ways of
connecting various protocols. This controller is therefore ideal as a micro-controller or communications
gateway (e.g. EnOcean, KNX, BACnet ...) or for acquiring, logging and processing consumption data.
Layout
Supply
1.5mm2 / max. 25 cm
Earthing bar
Automation
User flash file system onboard 128 MByte
stations
Integral communication
Ethernet connection (2 port switch) yes
10/100 Mbit/s, full duplex, autosensing, auto-crossing
1
USB connection yes
USB 1.1 device 12 Mbit/s
RS-485 (terminal X3) yes
up to 115 kbit/s
General data
Supply voltage 24 VDC, –20/+25% max. incl. 5% ripple (in accordance with EN/IEC 61131-2)
HMI Visualization
Battery for data backup (exchangeable) Lithium battery with a service life of 1 to 3 years
and operating
Operating temperature 0…55 °C
Dimensions (W×H×D) 142 × 142 × 60 mm
Type of Mounting Top-hat rail according to DIN EN60715 TH35 (1 × 35 mm) or on a flat surface
Protection type IP 20
Capacity 5V/+V(24V) internal max. 500 mA/200 mA
2
Power consumption typically 12 W
Automation Server Flash memory, Filesystem, FTP and Web-Server, E-Mail, SNMP
Automation Server
SNMP
integrated in
the base unit
On-Board inputs/outputs
room controller
Inputs
6 Digital inputs (4 + 2 interrupts) 15…30 VDC, 8 ms / 0,2 ms input filter Terminal X1
Dedicated
2 Analog inputs, selectable via DIP switch, –10…+10 VDC, 0…+/–20 mA,
Terminal X1
preconfigured for Ni1000 in the default setup Pt1000, Ni1000, Ni1000 L&S, 0…2.5 kΩ
Outputs
4 Digital outputs 24 VDC Terminal X0
3
1 PWM output 24 VDC / 0.2 A Terminal X0
Consumption data
Analogue output module Saia PCD7.W600 *) acquisition
This new analogue outputs (range 0 to +10 V) with 12 bits resolution has been especially developed for the new
PCD1 CPU (PCD1.M2xxx, PCD1.M0160E0, PCD1.M2110R1 ). It can be plugged in the slot A instead of a commu-
nication interface.
*) In preparation, see section C2 Product status
4
Ethernet cable
For installation in the sub electrical cabinet unit, angled or flexible network cable (e.g. SlimWire PRO) is recommended.
Cabinet
If conventional network cable is installed, mounting of the sub electrical cabinet cover cannot be guaranteed.
5
In addition to the onboard interfaces, modular expansion of interface functions is possible at slot A. Slot A
For this purpose, the Saia PCD1.M0160E0 supports numerous protocols. A detailed list of all protocols
find in chapter B2 „Communication & Interaction“.
X2 X1 X0
Current Current
consumption consumption
Communication at 5V bus at +V bus (24 V)
PCD7.F110S RS-485/RS-422 not electrically isolated 40 mA --- Slot A
PCD7.F121S RS-232 with RTC/CTS, DTR/DSR,
15 mA --- Slot A
DCD suitable for modem or EIB connection
PCD7.F150S RS-485 electrically isolated,
with activatable termination resistors 130 mA --- Slot A
PCD7.F180S Belimo MP-Bus, for connecting up to 8 drives on one line 15 mA 15 mA Slot A
M-Bus
M-Bus
M-Bus
RS-485 RS-232
Memory modules
The onboard memory can be extended by means of a PCD7.Rxxx module in slot M1. In addition, BACnet® IP or LON IP
can be enabled.
For more information about memory management and construction, see Chapter 1.1 Saia PCD® System description.
For the parallel operation of S-Monitoring and BACnet® respectively LON, please note the instructions on the
support homepage www.sbc-support.com