A321
JOB CARD PACKAGE TITLE:
Tail Number - MSN -
Es
FSN
VT-TTB - 06223 - 001

Reference Title DocType


49-70-00-810-821-A Data Memory Module P20 Fault (131-9(A)) TSM

JCP Title: Es CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 1


PRINT DATE: Jun 10/2020
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
REV DATE: May
JOB CARD
01/2020
TSM - VTI - A318/A319/A320/A321 TASK:
49-70-00-810-821-A
Tail Number - MSN - TITLE: 49-70-00-02 CONF 16
FSN: 49-70-00-810-821-A - Data Memory Module P20 Fault
VT-TTB - 06223 - 001 (131-9(A))

MECH. INSP.
** ON A/C FSN 001-050, 101-150, 201-250, 301-400
POST SB 49-1082 for A/C 251-251
TASK 49-70-00-810-821-A
Data Memory Module P20 Fault (131-9(A))
1. Possible Causes:

- ELECTRONIC CONTROL BOX (59KD)


- DATA MEMORY MODULE SHOWS WRAP TEST FAILURE
- DATA MEMORY MODULE SHOWS READ FAILURE
- DATA MEMORY MODULE SHOWS CHECKWORD FAILURE
- DATA MEMORY MODULE SHOWS APU S/N FAILURE
- DATA MEMORY MODULE SHOWS WRITE FAILURE
- damage/contamination of the electrical connector P20
- aircraft wiring
- DATA MEMORY MODULE (DMM) (P20)
- DATA MEMORY MODULE (DMM) (8062KM)

2. Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

Q
REFERENCE T DESIGNATION
Y
No specific A JUMPER-WIRE
R

B. Referenced Information
REFERENCE DESIGNATION
Ref. AMM APU Start by External Power
49-00-00-860-008
Ref. AMM APU Shutdown by External Power (131-9(A))
49-00-00-860-009
Ref. ASM 49-61-04
Ref. AMM Removal of the Electronic Control Box (ECB)
49-61-34-000-003 (131-9(A))

JCP Title: Es CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 5


PRINT DATE: Jun 10/2020
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
REV DATE: May
JOB CARD
01/2020
TSM - VTI - A318/A319/A320/A321 TASK:
49-70-00-810-821-A
Tail Number - MSN - TITLE: 49-70-00-02 CONF 16
FSN: 49-70-00-810-821-A - Data Memory Module P20 Fault
VT-TTB - 06223 - 001 (131-9(A))

MECH. INSP.

REFERENCE DESIGNATION
Ref. AMM Installation of the Electronic Control Box (ECB)
49-61-34-400-003 (131-9(A))
Ref. AMM Removal of the Data Memory Module
49-73-32-000-001 (131-9(A))
Ref. AMM Installation of the Data Memory Module
49-73-32-400-001 (131-9(A))
** ON A/C FSN 001-050, 101-150, 201-250, 301-400
Ref. AMM Re-start of the Data Memory Module
49-73-32-600-002 (131-9(A))

** ON A/C FSN 001-050, 101-150, 201-250, 301-400


POST SB 49-1082 for A/C 251-251
3. Fault Confirmation
SUBTASK 49-70-00-710-086-A
A. Read-out of ECB Trouble-Shooting Data
(1) Get access to the APU LAST LEG/PREVIOUS LEG report.
(2) Push the '>'-key adjacent to the related CFDS failure message.
(3) If the MCDU menu shows:
DATA MEMORY MODULE SHOWS WRAP TEST FAILURE
- Do the Fault Confirmation that follows:
(a) Set the APU MASTER SW to the OFF position and wait 35
seconds, minimum.
(b) Set the APU MASTER SW to the ON position.
(c) Get access to the APU LAST LEG/PREVIOUS LEG
report.
(d) Push the '>'-key adjacent to TEST on the MCDU.
(4) If the MCDU menu shows:
DATA MEMORY MODULE SHOWS READ FAILURE
DATA MEMORY MODULE SHOWS CHECKWORD FAILURE
DATA MEMORY MODULE SHOWS APU S/N FAILURE
- Do the Fault Confirmation that follows:
(a) Set the APU MASTER SW to the OFF position and wait 35
seconds, minimum.
(b) Set the APU MASTER SW to the ON position.

JCP Title: Es CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 2 of 5


PRINT DATE: Jun 10/2020
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
REV DATE: May
JOB CARD
01/2020
TSM - VTI - A318/A319/A320/A321 TASK:
49-70-00-810-821-A
Tail Number - MSN - TITLE: 49-70-00-02 CONF 16
FSN: 49-70-00-810-821-A - Data Memory Module P20 Fault
VT-TTB - 06223 - 001 (131-9(A))

MECH. INSP.

(c) Get access to the APU GND SCANNING menu.


(5) If the MCDU menu shows:
DATA MEMORY MODULE SHOWS WRITE FAILURE
- Do the Fault Confirmation that follows:
(a) Start the APU Ref. AMM 49-00-00-860-008.
(b) Get access to the APU GND SCANNING menu.
(c) Shut down the APU Ref. AMM 49-00-00-860-009.
(d) Wait until the ECB (59KD) power-down, speed < 7% plus
30 seconds.
(e) Set the APU MASTER SW to the ON position.
(f) Get access to the APU GND SCANNING menu.

4. Fault Isolation
** ON A/C FSN 001-050, 101-150, 201-250, 301-400
SUBTASK 49-70-00-810-072-B
B. If the APU GND SCANNING menu gives the maintenance message:
DATA MEMORY MODULE (8062KM)
related to Fault Code Number (FCN) 241 or 244
- Do a check for damage/contamination of the electrical connector
P20 of the DATA MEMORY MODULE (DMM).
(1) If the electrical connector P20 of the DMM is damaged/
contaminated:
- Do a repair/cleaning.
(2) If the electrical connector P20 of the DMM is OK:

(a) Disconnect the electrical connector P20 from the DMM/


APU interface.
(b) Do a check and repair of the aircraft wiring from
the ECB (59KD) AB/F11,F7 to structural ground, required
value > 100 kOhms
and
the ECB (59KD) AB/F11 to AB/F7, required value > 100
kOhms,
Ref. ASM 49-61-04.

JCP Title: Es CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 3 of 5


PRINT DATE: Jun 10/2020
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
REV DATE: May
JOB CARD
01/2020
TSM - VTI - A318/A319/A320/A321 TASK:
49-70-00-810-821-A
Tail Number - MSN - TITLE: 49-70-00-02 CONF 16
FSN: 49-70-00-810-821-A - Data Memory Module P20 Fault
VT-TTB - 06223 - 001 (131-9(A))

MECH. INSP.

(c) Put a JUMPER-WIRE across the sockets 8 and 9 of the


electrical connector P20 of the DMM on the APU harness
side.
(d) Do a check and repair of the aircraft wiring from
the ECB (59KD) AB/F11 to AB F7, required value < 10
Ohms
and
the ECB (59KD) AB/J2,J3 to structural ground, required
value > 100 kOhms
and
the ECB (59KD) AB/J2 to AB/J3, required value > 100
kOhms,
Ref. ASM 49-61-04.
(e) put a jumper across the sockets 10 and 11 of the electrical
connector P20 of the DMM on the APU harness side.
(f) Do a check and repair of the aircraft wiring from
the ECB (59KD) AB/J2 to AB/J3, required value < 10
Ohms
and
the ECB (59KD) AB/C6 to structural ground, required
value > 100 kOhms
and
the ECB (59KD) AB/C6 to AB/F11, required value > 100
kOhms,
Ref. ASM 49-61-04.
(g) Put a jumper across the sockets 6 and 7 of the electrical
connector P20 of the DMM on the APU harness side.
(h) Do a check and repair of the aircraft wiring from the ECB
(59KD) AB/C6 to AB/F11, required value < 10 Ohms, Ref.
ASM 49-61-04.
(3) If the fault continues:
- Re-start the DMM Ref. AMM 49-73-32-600-002.
(4) If the fault continues:
- Replace DATA MEMORY MODULE (DMM) (8062KM) Ref.
AMM 49-73-32-000-001 and Ref. AMM 49-73-32-400-001.
(5) If the fault continues:
- Replace the ELECTRONIC CONTROL BOX (59KD) Ref.
AMM 49-61-34-000-003 and Ref. AMM 49-61-34-400-003.
SUBTASK 49-70-00-810-073-B

JCP Title: Es CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 4 of 5


PRINT DATE: Jun 10/2020
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
REV DATE: May
JOB CARD
01/2020
TSM - VTI - A318/A319/A320/A321 TASK:
49-70-00-810-821-A
Tail Number - MSN - TITLE: 49-70-00-02 CONF 16
FSN: 49-70-00-810-821-A - Data Memory Module P20 Fault
VT-TTB - 06223 - 001 (131-9(A))

MECH. INSP.

C. If the APU GND SCANNING menu gives the maintenance message:


DATA MEMORY MODULE (8062KM)
associated with Fault Code Number (FCN) 242 or 243
- Do a check for damage/contamination of the electrical connector
P20 of the DATA MEMORY MODULE (DMM).
(1) If the electrical connector P20 of the DMM is damaged/
contaminated:
- Do a repair/cleaning.
(2) If the electrical connector P20 of the DMM is OK:
- Re-start the DMM Ref. AMM 49-73-32-600-002.
(3) If the fault continues:
- Replace the DATA MEMORY MODULE (DMM) (8062KM)
Ref. AMM 49-73-32-000-001 and Ref. AMM
49-73-32-400-001.
(4) If the fault continues:
- Replace the ELECTRONIC CONTROL BOX (59KD) Ref.
AMM 49-61-34-000-003 and Ref. AMM 49-61-34-400-003.
** ON A/C FSN 001-050, 101-150, 201-250, 301-400
POST SB 49-1082 for A/C 251-251
SUBTASK 49-70-00-710-087-A
D. Do the test given in Para. Fault Confirmation

© *** END OF CARD ***

JCP Title: Es CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 5 of 5