This document provides information about the FG-SP5R_AP 5” ceiling mount loudspeaker with fire dome. It is designed for flush installation in suspended ceilings and provides even sound distribution. It has a built-in protection to maintain system integrity in the event of a fire. The loudspeaker can be easily installed using the included mounting spring and fire dome brackets. It complies with EN54 Part 24 standards for fire resistant loudspeakers.

Uploaded by

baddar bedar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
120 views

FG-SP5R - AP Data Sheet PDF

This document provides information about the FG-SP5R_AP 5” ceiling mount loudspeaker with fire dome. It is designed for flush installation in suspended ceilings and provides even sound distribution. It has a built-in protection to maintain system integrity in the event of a fire. The loudspeaker can be easily installed using the included mounting spring and fire dome brackets. It complies with EN54 Part 24 standards for fire resistant loudspeakers.

Uploaded by

baddar bedar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FG-SP5R_AP

5” CEILING MOUNT
LOUDSPEAKER WITH FIRE DOME

PRODUCT OVERVIEW
Thank you for purchasing FG-SP5R_AP. Widely used in commercial
buildings and public facilities, Fireguard product is manufactured in strict
accordance with ISO 9001 standards. Please read this manual before
installation and follow all instructions.

FG-SP5R_AP Voice Alarm ceiling loudspeaker is designed for flush in


suspended ceiling and ideal for even sound distribution. The loudspeaker
has a built-in protection to ensure that, in the event of a fire, damage to
the loudspeaker does not result in failure of the loudspeaker circuit which
is connected. In this way, system integrity is maintained and ensuring
loudspeakers connected in the same circuit in other areas can still be used
to inform people of the situation.

The loudspeaker can be easily installed by using the mounting spring


attached. Likewise, the fire dome is mounted in the speaker openings on
the ceiling panel by using the sliding brackets and the wing nuts as first-fix.
FG-SP5R_AP is equipped with ceramic terminal blocks, thermal fuse and
heat-resistant, hightemperature wiring to comply with EN54 part 24.

Features Technical Specification


Model FG-SP5R
 Excellent sound reproduction Speaker 5”
 Fire resistant cover with fire dome Rated power 6W
 EN54-24 certified Impedance (Ω) 1.7k / 3.3k / 6.7k / 13k
Power taps @ 70V 3 W / 1.5 W / 0.75 W / 0.375 W
Power taps @ 100V 6 W / 3 W / 1.5 W / 0.75 W
SPL (1W/1m, 100Hz-10k Hz) 91 dB
Safety Notice
SPL (1W/4m, 100Hz-10k Hz) 79 dB
After installing the speaker it is

SPL (6W/4m, 100Hz-10k Hz) 88 dB
crucial to check carefully to ensure Frequency response (-10dB) 180 Hz - 20k Hz
that the unit is working properly Dimensions Ø 181 mm × 129 mm
Proper functioning cannot be
 Weight 1.29 kg
guaranteed if the speakers are not Material Steel
installed correctly in accordance with Front grill color White (RAL9003)
the instruction. Dome color Red (RAL3000)
Please observe the relevant national
 Installation opening size Ø 155 mm
regulations and guideline.
Fire dome mounting method Sliding plate with wing nut
Loudspeaker mounting method Spring clip grill
Ceramic terminal Yes (in fire dome)
0359
19
Thermal Fuse 150°
0359-CPR-XXXXX
* The reference axis is perpendicular to the centre point of the front grill
* The reference plane is perpendicular to the centre of the reference axis
MODEL DESCRIPTION * The horizontal plane is perpendicular to the centre of the reference plane
* The spec/data was measured using a standard baffle mounting in a anechoic
FG-SP5R_AP 5’’ Ceiling Loudspeaker
chamber as described in EN54-24

FIREGUARD GLOBAL LTD. 00-44-8450751042 00-44-8459751043 [email protected]


FREQUENCY RESPONSE AT dBspl(20uPa)@4m, With transformer:
1W/41.2V INPUT,1/3 OCT SMOOTHING 100V/70V line

90
Red wire plus tapping Black
100V Com
80 0.75W 1.5W 3W 6W
70V 0.375W 0.75W 1.5W 3W Com

70 IMP(Ω) 13K 6.7K 3.3K 1.7K

60
Sound level( dB )

50

40
Dispersion angles
30
Horizontal Vertical
20 1 oct. pink noise 500 Hz 187° 174°
1 oct. pink noise 1K Hz 173° 174°
10 1 oct. pink noise 2K Hz 151° 152°
1 oct. pink noise 4K Hz 59° 58°
0

0
00
00
50
00
00
00

10 0
00
50
00
0
5

0
0
0

5
0
0
0
0

00
0
10
12

20
25
16

31
40
50
63
80

25
31
40
50
63
80
10
12
16
20

Frequency(Hz)

CIRCUIT DIAGRAM THREE-VIEW DIAGRAM INSTALLATION

1 1. Cut out Ø 195


mm hole for
FG-SP6R
129mm

Screw
2 2. Loosen the
screw, push the fire
dome into ceiling

POLAR DIAGRAM Fixing


plate
Φ181 mm


3 3. Tighten the
330° dB 30° screw
-6

-12
300° 60°
-18 Spring
-24
mount
4. Attach the
-30
4 spring to the
270° 90°
spring mount
Opening Dimension

120°
155mm

240°

5 1. Push the speaker


210° 150° into the fire dome
180°

500Hz

FIREGUARD GLOBAL LTD. Unit 11 • Chancel Industrial Estate • Newhall Street


Willenhall • WV13 1NX • United Kingdom
Tel: 00-44-8450751042
Fax: 00-44-8459751043
Email: [email protected]
www.fireguard-Uk.com
FS546607
Fire Guard / FG-SP5R_EN_1.1