This document is a bill of quantities for electrical work on a villa project. It includes 8 items: A) Light fixtures, B) Light switches, C) Socket outlets, D) Switch power outlets, E) Branch circuits, F) Branch circuit panel boards, G) Main distribution boards, and H) Cable feeders. The document provides specifications for materials and quantities of electrical components needed to complete the villa's wiring.

Uploaded by

Ahmed Khattab
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
338 views5 pages

Segase Villa 1# Electrical #B.o.q

This document is a bill of quantities for electrical work on a villa project. It includes 8 items: A) Light fixtures, B) Light switches, C) Socket outlets, D) Switch power outlets, E) Branch circuits, F) Branch circuit panel boards, G) Main distribution boards, and H) Cable feeders. The document provides specifications for materials and quantities of electrical components needed to complete the villa's wiring.

Uploaded by

Ahmed Khattab
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 5

PROJECT : SEGAS COMPOUND DATE : 19/8/2006

PROJECT NO : E0616 REV No : 0


LOCATION VILLA TYPE 01

SPEC. ITEM
Item Description UNIT QTY RATE AMOUNT
No.

A- LIGHT FIXTURES:-
Supply, install, connect and test light fixtures including all lamps including all
mounting devices and brackets as shown on the drawings, specification and as
scheduled. All light fixtures will be supplied and installed by Contractor .

Light fixtures should be products of :-


- 3 BROTHERS
- Elsweedy (EGY LUX) or approved equal.

1 4x18w IP54 Surface mounted flourescent luminaire No 40 16500

2 wall mounted oblique with 100w lamp No 160 16500

3 Weather proof (IP54) wall mounted oblique with 100w lamp No 140 16500

4 Weather proof (IP54) wall mounted with 100w lamp No 140 16500

5 Down light with 100w Lamp No 260 16500

6 wall mounted flourscent luminaire IP54 (bathroom lamp 1x18w) No 60 16500

7 Staircase ceiling mounted luminaire with 100w lamp No 80 16500

8 Chandeliers As Per Architect Design No 60 16500

B- LIGHT SWITCHES
Supply, install and connect light switches complete including, conduits, conduit
fittings, switches, terminations, earthing, wiring from switches to branch circuit
according to specifications and as shown on drawings.

Switches should be products of :-


- GEWISS ( PLAYBUS RANGE )
- BTICHINO
- LEGRAND
1 One pole, one way 10A modular switch No 180 16110

2 Water proof one pole, one way 10A modular switch No 300 16110

3 One pole, two way 10A modular switch No 280 16110

C- SOCKET OUTLETS
Supply, install, connect and test socket outlets complete including conduits,
conduit fittings, wiring, earthing back to panel board or to branch circuit complete
including plaster rings, wiring, earthing, terminations, socket plate, cover, plugs
all necessary accessories and ancillary work according to specification and
schedules.

Sockets should be products of :-


- GEWISS ( PLAYBUS RANGE )
- BTICHINO
- LEGRAND
1 10A Douplex socket outlet No 420 16110

2 10A Water proof (IP 54) Douplex socket outlet No 60 16110

3 10A wall socket outlet No 40 16110

4 10A Water proof (IP 54) wall socket outlet No 100 16110

5 10A Switch Socket outlet No 120 16110

6 16A Water proof (IP 54) wall socket outlet No 40 16110

TOTAL
PROJECT : SEGAS COMPOUND DATE : 19/8/2006
PROJECT NO : E0616 REV No : 0
LOCATION VILLA TYPE 01

D- SWITCH POWER OUTLET

Supply, install, connect and test switch fuses complete including conduits, conduit
fittings, wiring, earthing back to panel board or to branch circuit complete
including plaster rings, wiring, earthing, terminations, socket plate, cover, plugs
all necessary accessories and ancillary work according to specification and
schedules.

Sockets should be products of :-


- GEWISS ( PLAYBUS RANGE )
- BTICHINO
- LEGRAND
1 16A Switch fuse with two pole. NO 100 16110

2 25A Switch fuse with two pole. NO 100 16110

3 32A Switch fuse with two pole. NO 20 16110

E- BRANCH CIRCUITS

Supply, install, connect and test PVC insulated 450/750V stranded copper
conductor wires from branch circuit panelboards to light & power outlets
including raceways, termination, glands and all necessary accessories and
ancillary works required for complete operative system.

Embeded or concealed surface mounted conduits should be rigid PVC. Exposed


mounted conduits should be galvanized steel.
- PVC conduits should be products of MARSHAL TUFFLEX CO. or approved
equal.
1 3x2.5mm² branch circuit for feeding (1) light fixtures No 60 16110&16120

2 3x2.5mm² branch circuit for feeding (5) light fixtures No 20 16110&16120

3 3x2.5mm² branch circuit for feeding (7) light fixtures No 100 16110&16120

4 3x2.5mm² branch circuit for feeding (10) light fixtures No 20 16110&16120

5 3x4 mm² copper conductor branch circuit, for feeding 1 No. power Receptacles No 240 16110&16120

6 3x6 mm² copper conductor branch circuit, for feeding 1 No. power Receptacles No 100 16110&16120

7 3x10 mm² copper conductor branch circuit, for feeding 1 No. power Receptacles No 20 16110&16120

8 3x4 mm² copper conductor branch circuit, for feeding 2 No. power Receptacles No 20 16110&16120

9 3x4 mm² copper conductor branch circuit, for feeding 3 No. power Receptacles No 40 16110&16120

10 3x4 mm² copper conductor branch circuit, for feeding 4 No. power Receptacles No 40 16110&16120

11 3x4 mm² copper conductor branch circuit, for feeding 5 No. power Receptacles No 60 16110&16120

F- BRANCH CIRCUIT DISTRIBUTION PANEL BOARDS

Supply, install, connect and test the following panel boards complete with circuit
breakers, bus bars cabinets, conductors relays, residual current devices, indicator
lamps and all necessary accessories and ancillary works required in accordance
with the specification, construction drawings & attached schedules.
Panel boards should be products of :-
- Emg ( Schnieder )
- ARAB (abb)
1 BCP-GV1 No 20 16470

2 BCP-FV1 No 20 16470

3 V1L-EMP1 No 20 16470

TOTAL
PROJECT : SEGAS COMPOUND DATE : 19/8/2006
PROJECT NO : E0616 REV No : 0
LOCATION VILLA TYPE 01

G- MAIN DISTRIBUTION BOARDS


Supply, install, connect and test main distribution boards with all necessary
accessories circuit breakers, contractors, relays, indicator lamps, cable terminals
& all ancillary works required for complete operative system according to the
specifications & as shown on drawings.

1 V1L-MP1 No 20 16425

H- CABLE FEEDERS

Supply, install, connect and test PVC insulated, PVC sheathed 600/1000V
stranded copper cables from main feeder distribution panelboard to branch circuit
panels & starter panels including raceways, termination, glands and all necessary
accessories and ancillary works required for complete operative system..
power cables shall be products :-
- Elsweedy Co. or approved equal
1 Supply, install, connect and test
Pvc / pvc cable [(4x10)mm2 + 10mm2)] and all necessary accessories and MT 200 16114&16120
ancillary works required as specified and as shown on drawings.
2 Supply, install, connect and test
Pvc / pvc cable [(4x16)mm2 + 16mm2)] and all necessary accessories and MT 120 16114&16120
ancillary works required as specified and as shown on drawings.
3 Supply, install, connect and test
Pvc / pvc cable [(4x35)mm2 + 16mm2)] and all necessary accessories and MT 200 16114&16120
ancillary works required as specified and as shown on drawings.

I- EARTHING (GROUNDING) SYSTEM


Furnishing, supplying, installing and testing a complete protective earthing (PE)
system complete with earthing pits, earthing electrodes, equalizer bars, earth
continuity conductor, and earthing conductor to switchboards, diesel generator set LS LS 16450
1 and transformers complete with all accessories, fixing brackets, tets links,
complete with all accessories, fixing brackets, tets links suspensions, drilling and
cutting for complete installation all in accordance with technical specifications
and drawings
NB
Earthing impedance must be <= 2 ohm
Grounding system components shall be products :-
- Furse Co. or approved equal
J- TELECOMMUNICATION SYSTEM

Supply, install, connect and test Telephone System complete including conduits,
conduit fittings,(2x0.6mm) cabling, earthing complete including plaster rings,
wiring, earthing, terminations, socket plate, cover, plugs all necessary accessories
and ancillary work according to specification and Design
Telecommunication system cabling & outlets shall be products of :-
- Avaya Co. or approved equal

1 Supply, install, connect and test socket RJ-11 telephone outlets complete NO 240 16740
including conduits, conduit fittings, (2x0.6mm) cabling, earthling complete
including plaster rings, wiring, earthling, terminations, socket plate, cover, plugs
all necessary accessories and ancillary work according to specification and Design
Sockets should be products of :-
'legrand
avaya
TOTAL
PROJECT : SEGAS COMPOUND DATE : 19/8/2006
PROJECT NO : E0616 REV No : 0
LOCATION VILLA TYPE 01

Supply, install, connect and test of 15 pair wall mount telephone frames complete
2 as specified and indicated in the drawings with all necessary termination, NO 20 16740
conduits, raceways, patch cords, cables and all necessary accessories required to
complete operative system
K- T.V & SATELLITE SYSTEM

Supply, install, connect and test central dishes System complete including
conduits, conduit fittings, coaxial cable, distribution amplifiers , splitters ,
earthing complete including wiring, earthing terminations and all necessary
accessories and ancillary work according to specification and Design
1 Supply, install, connect and test of No 20
16780
Tee splitters one input two output
2 Supply, install, connect and test of No 20
16780
Tee splitters one input three output
3 Supply, install, connect and test of No 20
16780
T.V outlet
4 Supply, install, connect and test of LS LS 16780

TV circits network including all necessary cabling, raceways & accessories. The
works may include excavation in different soils & backfilling complote wiht
inspection manholes. The item shall be complete with all necessary works
according to the specifications & the tender drwings.

TOTAL
PROJECT : SEGAS COMPOUND DATE : 19/8/2006
PROJECT NO : E0616 REV No : 0
LOCATION VILLA TYPE 01

DIVISION 5 : ELECTRICITY WORKS

DIVISION Summary Page

Page 1

Page 2

Page 3

Page 4

TOTAL