0% found this document useful (0 votes)
58 views

DBASF Mastertile30

This document provides information on MasterTile 30, a polymer-modified cement-based tile adhesive suitable for fixing ceramic, porcelain, and stone tiles in interior and exterior applications. It exceeds British standard requirements, has an extended open time, and high bond strength. MasterTile 30 is available in 20kg bags, can be used for floor and wall installations, and provides waterproof adhesion when applied according to specifications. Surface preparation, application instructions, coverage rates, storage requirements, and health and safety precautions are also outlined.

Uploaded by

bassem muhanna
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views

DBASF Mastertile30

This document provides information on MasterTile 30, a polymer-modified cement-based tile adhesive suitable for fixing ceramic, porcelain, and stone tiles in interior and exterior applications. It exceeds British standard requirements, has an extended open time, and high bond strength. MasterTile 30 is available in 20kg bags, can be used for floor and wall installations, and provides waterproof adhesion when applied according to specifications. Surface preparation, application instructions, coverage rates, storage requirements, and health and safety precautions are also outlined.

Uploaded by

bassem muhanna
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

MasterTile® 30

Cementitious, polymer modified tile adhesive for non-vitrified, vitrified, glass mosaic, porcelain and
non-moisture sensitive natural stones tiles

DESCRIPTION  Exceeds British Standard requirements


MasterTile 30 is a polymer-modified cement-  Extended open / wet time
based tile adhesive for thin or thick bed fixing of  High adhesive bond strength
ceramic tiles in interior or exterior situations,
especially those exposed to permanently wet PACKAGING
conditions. MasterTile 30 is available in 20 kg bags.

Suitable substrates are concrete, sand cement STANDARDS


screeds and renders, plaster boards, gypsum fibre
boards and suitably prepared timber. ANSI A 118.1
ANSI A 118.4 (MasterTile 30 mixed with
MasterTile A 200)
TYPICAL APPLICATIONS
MasterTile 30 is the adhesive of choice for
TYPICAL PROPERTIES*
swimming pools and may be used with confidence
in all wet process applications including: abattoirs,
shower rooms, institutional kitchens, bathrooms, Colours Off white and Grey
Plastic density 1800 kg/m³
and decorative, high risk cladding.
Yield A 20 kg bag mixed with
MasterTile 30 may be used to tile directly onto 3.6-4.0 L of water
glazed tile surfaces and is especially yields approximately
recommended for non-porous or high density and 13.1-13.3 L of mixed
glass mosaics where it may be used to both fix and adhesive
grout. Curing times** (on slightly absorbent substrates)
- Walked on after approx. 24 h
Used in conjunction with MasterTile RSG 705, the - groutable after approx. 24 h
system is suitable for use where chemical - able to bear weight after approx. 7 days
** At +23°C and 50% relative humidity. Higher temperatures
resistance or a high standard of hygienic quality is
reduce, lower temperatures increase the times given.
essential.

For extreme conditions such as vibration or APPLICATION GUIDELINES


temperature extremes etc. MasterTile 30 can be Surfaces to be tiled, should be sound,
mixed with MasterTile A 200 instead of water. dimensionally stable, clean and free from loose
laitance, paint, oil, grease, mould release agent
MasterTile 30 mixed with MasterTile A 200 is and residual curing compound. It should be
suitable for fixing certain types of natural stone. ensured that tiles are dry, and free of contaminants
Please consult BASF Technical Service that could impair adhesion.
Department for advice.

MasterTile 30 is a blend of Portland cement, and


graded sand, reinforced with a high organic
polymer content.

ADVANTAGES
 Waterproof: immersion will not affect adhesion
 Non-slip
 Ready for use - just add water
 Thin or thick bed
MasterTile® 30
SURFACE PREPARATION For all other vertical application, the adhesive bed
Porous concrete, mortars, renders, plaster boards should be combed horizontally with a notched
and gypsum fibre boards should be primed with trowel to remove excess.
MasterTile P 302 to reduce suction.
Tiles should be dry and fixed by pressing into place
with slight twisting motion, ensuring the tile back
Timber surfaces should be checked to ensure
achieves full contact with the adhesive.
rigidity and soundness to accept the additional
loading without deflection.
Ceramic tiles should never be butt joined. Leave a
minimum of 2 mm around tiles. Adjustments to
Provision must be made to ensure adequate
tiles should only be made during the adhesives
ventilation beneath tiled timber flooring. Tongue
open wet time.
and groove, parquet and sprung floorings must
first be strengthened by screwing 12 mm thick
Remove excess adhesive from the face of the tile
exterior grade plywood at 200mm centres onto the
with a damp sponge or cloth before it sets.
existing timber base.
Similarly, joints must be raked out in readiness for
grouting.
Timber partition walls should be stiffened by
Leave for a minimum of 24 hours before grouting.
screwing at 200 mm centres onto studding, in both
Select the appropriate grout for joint size and in
directions.
service use from the MasterTile range of
Timber surfaces should always be primed with products.
MasterCast 141 / CEMENT SLURRY.
MasterCast 141 / CEMENT SLURRY should only COVERAGE / YIELD
be applied after MasterTile 30 has been mixed, to
ensure adhesive is ready to apply immediately onto Solid bed fixing: 3 - 6 mm depth
wet primer. 5.4 kg - 10.8 kg/m²
Notched trowel: smooth surface 2 kg/m²
MIXING INSTRUCTIONS
Add MasterTile 30 to cool, clean water at the WATCHPOINTS
following rates: Movement joints should be provided in accordance
Place approx. 4 L gauging water in a clean mixing with normal practice. Refer to published local
vessel. Mix to a uniform lump free consistency and standards or BS 5385.
allow to stand for 5 min. before use. Full bag
volumes should be mixed in a forced action mixer. MasterTile 30 should not be used on painted or
Part bags should preferably be mixed using a slow metal surfaces. The use of chilled mixing water
speed drill and mixing paddle. will extend open wet time in high ambient
temperatures.
APPLICATION INSTRUCTIONS
Gypsum plaster boards and surfaces, must be
Apply MasterTile 30 to a uniform thickness of 3
subjected to pre-treatment. Please consult BASF's
mm 6 mm or sufficient to cover the studs or keys Technical Services Department for advice.
on the tile back; (on a working area of not more
than 1 m²). Solid bed fixing is recommended for
wet conditions and for ceramic and marble flooring STORAGE AND SHELF LIFE
tiles, and vertical heavy-duty applications including Store out of direct sunlight, clear of the ground on
decorative stone cladding. If preferred, the pallets protected from rainfall. Avoid excessive
MasterTile 30 can additionally be buttered on the compaction.
backs of the tiles to ensure full adhesive contact. The shelf life is 12 months when stored as above.
MasterTile® 30
HEALTH AND SAFETY
As with all chemical products, care should be
taken during use and storage to avoid contact with
eyes mouth, skin and foodstuffs. Treat splashes to
eyes and skin immediately. If accidentally ingested,
seek immediate medical attention. Reseal
containers after use. For further information, refer
to material safety data sheet.

QUALITY AND CARE


All products originating from BASF’s Dubai, UAE
facility are manufactured under a management
system independently certified to conform to the
requirements of the quality, environmental and
occupational health & safety standards ISO 9001,
ISO 14001 and ISO 45001.

* Properties listed are based on laboratory controlled tests.

® = Registered trademark of the BASF-Group in many countries.

BASF_CC-UAE/Tile_30_01_96/v5/01_17/v6/04_18/v7/12_19
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC


P.O. Box 37127, Dubai, UAE
Tel: +971 4 8090800, Fax: +971 4 8851002
www.master-builders-solutions.basf.ae

Disclaimer: the LRQA mark relates to


certified management system and not to the
product mentioned on this datasheet