Module 4 PDF
Module 4 PDF
EDDY CURRENT
TESTING
DEV
Introduction
DEV
Outline
• Electromagnetic induction
• Generation of eddy currents
• Inspection applications
• Equipment utilized in eddy current inspection
Probes/Coils
Instrumentation
Reference standard
• Advantages and Limitations
• Glossary of Terms
DEV
Electromagnetic Induction
• Eddy currents are created through a process called
electromagnetic induction.
• When alternating current is applied to the conductor,
such as copper wire, a magnetic field develops in
and around the conductor.
• This magnetic field expands as the alternating
current rises to maximum and collapses as the
current is reduced to zero.
DEV
Electromagnetic Induction (cont.)
If another electrical conductor is brought into the
proximity of this changing magnetic field, the reverse
effect will occur. Magnetic field cutting through the
second conductor will cause an “induced” current to
flow in this second conductor. Eddy currents are a
form of induced currents!
Current Flow
DEV
Generation of Eddy Currents
Eddy currents are induced electrical currents that flow
in a circular path. They get their name from “eddies”
that are formed when a liquid or gas flows in a circular
path around obstacles when conditions are right.
Test Probe
Eddy Currents
DEV
Generation of Eddy Currents (cont.)
In order to generate eddy currents for an inspection a
“probe” is used. Inside the probe is a length of
electrical conductor which is formed into a coil.
DEV
Generation of Eddy Currents (cont.)
Alternating current is allowed to flow in the coil at a
frequency chosen by the technician for the type of test
involved.
DEV
Generation of Eddy Currents (cont.)
A dynamic expanding and collapsing magnetic field
forms in and around the coil as the alternating current
flows through the coil.
DEV
Generation of Eddy Currents (cont.)
When an electrically conductive material is placed in
the coil’s dynamic magnetic field electromagnetic,
induction will occur and eddy currents will be
induced in the material.
DEV
Generation of Eddy Currents (cont.)
Eddy currents flowing in the material will generate their
own “secondary” magnetic field which will oppose the
coil’s “primary” magnetic field.
DEV
Generation of Eddy Currents (cont.)
This entire electromagnetic induction process to
produce eddy currents may occur from several
hundred to several million times each second
depending upon inspection frequency.
DEV
Principle
DEV
Working…
• Eddy current testing is based on the physics phenomenon of
electromagnetic induction.
• In an eddy current probe, an alternating current flows through a wire coil
and generates an oscillating magnetic field.
• If the probe and its magnetic field are brought close to a conductive material
like a metal test piece, a circular flow of electrons known as an eddy current
will begin to move through the metal like swirling water in a stream.
• That eddy current flowing through the metal will in turn generate its own
magnetic field, which will interact with the coil and its field through mutual
inductance.
• Changes in metal thickness or defects like near-surface cracking will
interrupt or alter the amplitude and pattern of the eddy current and the
resulting magnetic field.
• This in turn affects the movement of electrons in the coil by varying the
electrical impedance of the coil.
• The eddy current instrument plots changes in the impedance amplitude and
phase angle, which can be used by a trained operator to identify changes in
the test piece.
DEV
Generation of Eddy Currents (cont.)
•Eddy currents are strongest at the surface of the material and decrease
in strength below the surface.
•The depth that the eddy currents are only 37% as strong as they are on
the surface is known as the standard depth of penetration or skin depth.
•This depth changes with probe frequency, material conductivity and
permeability.
Standard Depth
of
Depth
Depth
Penetration
(Skin Depth)
1/e or 37 %
of surface density
Eddy Current Density Eddy Current Density
High Frequency Low Frequency
High Conductivity DEV
Low Conductivity
High Permeability Low Permeability
Inspection Data
• There are three characteristics of the specimen that
affect the strength of the induced eddy currents.
– The electrical conductivity of the material
– The magnetic permeability of the material
– The amount of solid material in the vicinity of the
test coil.
• Information about the strength of the eddy currents
within the specimen is determined by monitoring
changes in voltage and/or current that occur in the
coil.
• The strength of the eddy currents changes the
electrical impedance (Z) of the coil.
DEV
Inspection Data (cont.)
Impedance (Z) in an eddy current coil is
the total opposition to current flow. In a R
coil, Z is made up of resistance (R) and
~ Test
Coil
XL
inductive reactance (XL).
Definitions:
• Resistance - The opposition of current
flow, resulting in a change of electrical
energy into heat or another form of
energy.
• Inductive Reactance (XL) - Resistance to
AC current flow resulting from
In an AC coil, induction from
electromagnetic induction in the coil. the magnetic field of one loop
• Impedance (Z) - The combined of the coil causes a secondary
current in all other loops. The
opposition to current flow resulting from secondary current opposes the
inductive reactance and resistance.
DEV primary current.
Inspection Applications
One of the major advantages of eddy current as an
NDT tool is the variety of inspections that can be
performed.
DEV
Material Thickness Measurement
• Thickness measurements are possible with eddy
current inspection within certain limitations.
• Only a certain amount of eddy currents can form
in a given volume of material.
• Therefore, thicker materials will support more
eddy currents than thinner materials.
• The strength (amount) of eddy currents can be
measured and related to the material thickness.
Magnetic Field
From Probe
Test
Material
Eddy Currents
DEV
Material Thickness Measurement
(cont.)
Eddy current inspection is often used in the aviation
industries to detect material loss due to corrosion
and erosion.
DEV
Material Thickness Measurement
(cont.)
Eddy current inspection is used extensively to
inspect tubing at power generation and
petrochemical facilities for corrosion and erosion.
DEV
Crack Detection
Crack detection is one of the primary uses of eddy current
inspection.
Cracks cause a disruption in the circular flow patterns of
the eddy currents and weaken their strength.
This change in strength at the crack location can be
detected.
Magnetic Field
From Test Coil
Magnetic Field
From
Eddy Currents
Crack
Eddy Currents
DEV
Crack Detection (cont.)
Eddy current inspection is exceptionally well suited for
the detection of cracks, with an especially high
sensitivity to detection of surface breaking cracks.
DEV
Crack Detection (cont.)
Eddy current inspection of “bead seat” area on aircraft
wheel for cracks using special probe that conforms to
the shape of the rim.
DEV
Crack Detection (cont.)
Loading points, such as fastener holes, are high
stress areas and often the site of service induced
fatigue cracking. Rotating probe guns can be used to
inspect a large number of holes in a short period of
time. The photo on the right is a waterfall plot of the
cross section of a fastener hole. Each horizontal line
represents one rotation of the probe gun. A vertical
signal indicates a crack.
DEV
Nonconductive Coating
Measurement
Nonconductive coatings on electrically conductive
substrates can be measured very accurately with
eddy current inspection. (Accuracy of less that one mil is not
uncommon.)
The coating displaces the eddy current probe from
the conductive base material and this weaken the
strength of the eddy currents.
This reduction in strength can be measured and
related to coating thickness.
Nonconductive
Coating
Conductive
Base Metal
DEV
Eddy Currents
Nonconductive Coating
Measurement (cont.)
The photo to the left shows an aircraft panel paint
thickness inspection. On the right, the display of a
digital eddy current inspection instrument shows the
different signals obtained by measuring eight
different thicknesses of paint on aluminum.
Increasing paint
thickness
DEV
Monitoring Conductivity and
Permeability Variations
Eddy current inspection is sensitive to changes in a
material’s electrical conductivity and magnetic
permeability. This “sensitivity” allows the inspection
method to be used for such inspection procedures as:
• Material Identification
• Material Sorting
• Determination of heat damage
• Cladding and plating thickness measurement
• Heat treatment monitoring
DEV
Conductivity Measurements
Boeing employees in Philadelphia were given the
privilege of evaluating the Liberty Bell for damage
using NDT techniques. Eddy current methods were
used to measure the electrical conductivity of the
Bell's bronze casing at a various points to evaluate
its uniformity.
DEV
Equipment
• Equipment for eddy current inspection is very
diversified. Proper equipment selection is important
if accurate inspection data is desired for a particular
application.
• As a minimum, at least three basic pieces of
equipment are needed for any eddy current
examination:
– Instrumentation
– Probes
– Reference Standards
DEV
Instrumentation - Meters
DEV
Digital Meters
Digital meters are typically designed to examine one
specific attribute of a test component such as
conductivity or nonconductive coating thickness.
These meters tend to have slightly higher accuracy
than analog devices.
DEV
Analog Meters
Analog meters can be
used for many different
inspection applications
such as crack detection,
material thickness
measurements,
nonconductive coating
measurements or
conductive coating
measurements.
DEV
Analog Meters (cont.)
The display read-out found on most analog
instruments is typically either a calibrated or
uncalibrated display.
• Calibrated displays have an
inherent scaling factor which
correlates to the property the
instrument is designed to measure
such as conductivity.
• Uncalibrated displays are
typically more flexible in the
variety of different tests they
can perform. These types of
instruments, however, require
the use of data extrapolation
techniques if quantitative data
DEV
is desired.
Portable Eddy Scopes
DEV
Portable Eddy Scopes (cont.)
Portable eddy scopes are another category of
instrumentation and they present the inspection data in
the form of an impedance plane diagram.
• On the impedance diagram,
the total impedance is
displayed by plotting its
resistance component and
inductive reactance
component at 90 degrees to
each other.
• This is beneficial for both
separation and identification
of test variables that can
effect inspection results.
DEV
Impedance diagram…
• If the eddy current circuit is balanced in air and
then placed on a piece of aluminum, the
resistance component will increase (eddy
currents are being generated in the aluminum
and this takes energy away from the coil, which
shows up as resistance) and the inductive
reactance of the coil decreases (the magnetic
field created by the eddy currents opposes the
coil's magnetic field and the net effect is a
weaker magnetic field to produce inductance).
DEV
Impedance diagram…
• When a probe is placed on a magnetic material such as steel,
something different happens.
• Just like with aluminum (conductive but not magnetic), eddy currents
form, taking energy away from the coil, which shows up as an
increase in the coils resistance.
• And, just like with the aluminum, the eddy currents generate their
own magnetic field that opposes the coils magnetic field.
• However, you will note for the diagram that the reactance increases.
This is because the magnetic permeability of the steel concentrates
the coil's magnetic field.
• This increase in the magnetic field strength completely overshadows
the magnetic field of the eddy currents.
• The presence of a crack or a change in the conductivity will produce
a change in the eddy current signal similar to that seen with
aluminum.
DEV
Portable Eddy Scopes (cont.)
Modern eddy scopes are usually digital based
instruments which can often be purchased as either
a single or dual frequency tester. Dual frequency
instruments are capable of sequentially driving a
probe at two different inspection frequencies.
DEV
Portable Eddy Scopes (cont.)
Digital scopes often have an RS232 (serial)
connection for interfacing with a serial printer or
computer as well as provisions for output of signals
to recording devices such as a strip-chart recorder. In
addition, these instruments contain a small amount of
RAM so that equipment settings as well as screen
presentations can be stored for later reference.
DEV
Multi-Frequency Eddy
Current Instruments
DEV
Multi-Frequency Eddy
Current Instruments (cont.)
• Multi-Frequency instruments usually refer to
equipment that can drive inspection coils at more
than two frequencies either sequentially
(multiplexing) or simultaneously.
• This type of instrumentation is used extensively for
tubing inspection in the power generation, chemical
and petrochemical industries.
• These instruments are often capable of being
computer networked and may have as many as four
probes attached to them at one time.
DEV
Multi-Frequency Eddy
Current Instruments (cont.)
Advantages of Multi-frequency inspections:
Allows increased inspection information to be
collected from one probe pulling.
Provides for comparison of same discontinuity
signal at different frequencies.
Allows mixing of frequencies which helps to reduce
or eliminate sources of noise.
Often improves detection, interpretation and sizing
capabilities of discontinuities.
DEV
Multi-Frequency Eddy
Current Instruments (cont.)
Screen of multi-frequency instrument during inspection.
DEV
Eddy Current Probes
DEV
Eddy Current Probes (cont.)
• Probes selection is critical to acquiring adequate
inspection data.
• Several factors to consider include:
– Material penetration requirements (surface vs.
subsurface)
– Sensitivity requirements
– Type of probe connections on eddy current
instrument (many variations)
– Probe and instrument impedance matching (will
probe work with instrument)
– Probe size (smaller probes penetrate less)
– Probe type (absolute, differential, reflection or
hybrid)
DEV
Eddy Current Probes (cont.)
• Due the the large variety of probes in eddy current
testing there are many different systems of
classification.
• Three of the most common classifications are:
– Surface probes
– Inside Diameter (I.D.) or Bobbin Probes
– Outside Diameter (O.D.) or Encircling probes
DEV
Eddy Current Probes (cont.)
Surface probes are coils that are typically mounted
close to one end of a plastic housing. As the name
implies, the technician moves the coil end of the probe
over the surface of the test component.
DEV
Eddy Current Probes (cont.)
Some surface probes are specifically designed for
crack detection of fastener holes. These include
sliding probes, ring probes and hole probes.
DEV
Eddy Current Probes (cont.)
Surface probes can be
very small in size to
allow accessibility to
confined areas.
Finger Probe
DEV
Eddy Current Probes (cont.)
Inside Diameter (I.D.) probes, also known as bobbin
probes, are coils that are usually wound
circumferentially around a plastic housing. These
probes are primarily designed for inspection inside of
tubular materials.
DEV
Eddy Current Probes (cont.)
Outside Diameter (O.D.) probes are coils that are
wound the circumference of a hollow fixture. The coil is
designed such that the test part is ran through the
middle of the coil. These probes can be used to inspect
bars, rods as well as tubes.
DEV
• Eddy current probes are classified by the configuration and mode of
operation of the test coils.
• The configuration of the probe generally refers to the way the coil or coils
are packaged to best "couple" to the test area of interest.
• An example of different configurations of probes would be bobbin probes,
which are inserted into a piece of pipe to inspect from the inside out, versus
encircling probes, in which the coil or coils encircle the pipe to inspect from
the outside in.
• The mode of operation refers to the way the coil or coils are wired and
interface with the test equipment.
• The mode of operation of a probe generally falls into one of four categories:
absolute, differential, reflection and hybrid.
DEV
Differential probes
DEV
Reflection probes
• Reflection probes have two coils similar to a differential probe, but
one coil is used to excite the eddy currents and the other is used to
sense changes in the test material. Probes of this arrangement are
often referred to as driver/pickup probes. The advantage of
reflection probes is that the driver and pickup coils can be separately
optimized for their intended purpose. The driver coil can be made so
as to produce a strong and uniform flux field in the vicinity of the
pickup coil, while the pickup coil can be made very small so that it
will be sensitive to very small defects.
• The through-transmission method is sometimes used when
complete penetration of plates and tube walls is required.
DEV
DEV
Reference Standards
DEV
Reference Standards (cont.)
• In order to give the eddy current inspector useful
data while conducting an inspection, signals
generated from the test specimen must be
compared with known values.
• Reference standards are typically manufactured
from the same or very similar material as the test
specimen.
• Many different types of standards exist for due to the
variety of eddy current inspections performed.
• The following slides provide examples of specific
types of standards.
DEV
Reference Standards (cont.)
Material thickness standards used to help
determine such things as material thinning caused
by corrosion or erosion.
DEV
Reference Standards (cont.)
Crack Standards:
DEV
Reference Standards (cont.)
ASME Tubing Pit Standard:
DEV
Reference Standards (cont.)
Nonconductive coating (paint) standard with various
thickness of paint on aluminum substrate.
DEV
Advantages of Eddy Current
Inspection
• Sensitive to small cracks and other defects
• Detects surface and near surface defects
• Inspection gives immediate results
• Equipment is very portable
• Method can be used for much more than flaw
detection
• Minimum part preparation is required
• Test probe does not need to contact the part
• Inspects complex shapes and sizes of conductive
materials
DEV
Limitations of Eddy Current
Inspection
• Only conductive materials can be inspected
• Surface must be accessible to the probe
• Skill and training required is more extensive than
other techniques
• Surface finish and and roughness may interfere
• Reference standards needed for setup
• Depth of penetration is limited
• Flaws such as delaminations that lie parallel to the
probe coil winding and probe scan direction are
undetectable
DEV
Glossary of Terms
• Alternating Current: electrical current that regularly
reverses direction.
• Analog: being or relating to a mechanism in which data
is represented by continuously variable physical
quantities such as a watch with hour and minute hands.
• ASME: acronym for American Society of Mechanical
Engineers. This society is highly involved in establishing
and maintaining industrial standards.
DEV
Glossary of Terms
• CRT: acronym for Cathode Ray Tube. Vacuum tube that
uses one or more electron guns for generating an image.
• Calibration: adjustment of a test systems response
using known values so that unknown quantities may be
derived.
• Conductor: material capable of allowing electrical
current to flow through it.
• Discontinuity: an interruption in the physical structure of
a part. Cracks are examples of discontinuities.
• EDM: acronym for Electrical Discharge Machine.
DEV
Glossary of Terms
• EDM: acronym for Electrical Discharge Machine.
Machining technique which uses an electrode and
electrical current to remove metal. Sometimes used to
prepare calibration standards for eddy current testing.
• Electromagnetic Induction: process which creates
electrical current flow when a dynamic magnetic field is
brought into close proximity with an electrical conductor.
• Extrapolation: to project or predict unknown values from
know quantities.
DEV
Glossary of Terms
• I.A.C.S.: acronym for International Annealed Copper
Standard. Standard unit of measurement of electrical
conductivity in eddy current testing with pure
annealed copper as the standard, measuring 100%
at 20 degrees Celsius.
• Impedance Plane Diagram: A diagram that depicts
the changes in electrical impedance that occur in an
eddy current coil as test variables change.
• Multiplexing: use of a time sharing system in which
a coil is stimulated at several different frequencies
one after another for a certain amount of time.
Results from each stimulation can then be processed
and displayed.
DEV
Glossary of Terms
• Permeability: the ease with which a material can be
magnetized.
• Probe: common term used in eddy current inspection
that refers to the test coil.
• RAM: acronym for Random Access Memory. Most
modern eddy current instruments have some form of
memory used as a data buffer to store information.
DEV
DEV