RESULTS
Width of separator in feet 5.000
Depth of separator in feet 2.500
Length of separator in feet 25.000
Minimum Maximum
Allowable Design Allowable
Result Result
terminal velocity (in cm/s) 1.80 1.80 1.80
terminal velocity (in ft/min) 3.54 3.54 3.54
Minimum cross sectional area needed (in ft) 11.14 11.14 11.14
Cross Sectional Area (in square feet) 11.14 12.50 160.00
maximum horizontal velocity (15*vt, but must be <=3) 3.00 3.00 3.00
horizontal velocity (in ft/min) 3.00 2.67 0.21
vh/vt 0.85 0.76 0.06
short-circuiting factor 1.20 1.20 1.17
Length of unit (must be at least 5X of width) (in ft) 5.00 25.00 100.00
length/width 5.00 5.00 5.00
minimum horizontal area 11.34 11.31 11.08
Width of channel (in feet) (must be 6 to 20) 1.00 5.00 20.00
Depth (in feet) 0.30 2.50 10.00
Depth/Width Ratio (must be .3 to .5) 0.30 0.50 0.50
Step 1:
Adjust the width and depth of the chanel until you achieve a
horizontal velocity <=3. Ideal horizontal velocity should be in
the <=2 range at average flow. Make sure that you maintain
a depth/width ratio of .3 to .5
An "oil droplet size" of 150 is typically the norm for
API separators. Do not change this value unless
you have a specific need. The minimum useable
value is 60
1
Temperature (in deg F)
0.98
0.97
0.96
0.95
0.94
0.93
0 50 100 150 200 250
Density (in g/cm3)
Temp Absolute Viscosity Kinematic Viscosity
°F Centipoises Poise Density (g/cm3) Centistokes SSU ft²/sec
32 1.79 0.0179 0.9998 1.79 33 1.931E-05
50 1.31 0.0131 0.9997 1.31 31.6 1.41E-05
60 1.12 0.0112 0.999 1.12 31.2 1.217E-05
70 0.98 0.0098 0.99797 0.98 30.9 1.059E-05
80 0.86 0.0086 0.9966 0.86 30.6 9.3E-06
85 0.81 0.0081 0.9958 0.81 30.4 8.69E-06
100 0.68 0.0068 0.993 0.69 30.2 7.39E-06
120 0.56 0.0056 0.9885 0.57 30 6.09E-06
140 0.47 0.0047 0.9832 0.48 29.7 5.14E-06
160 0.4 0.004 0.9771 0.41 29.6 4.42E-06
180 0.35 0.0035 0.9704 0.36 29.5 3.85E-06
212 0.28 0.0028 0.95836 0.29 29.3 3.19E-06
t u r b u le n c e a n d s h o r t c ir c u it in g f a c t o
vh/vt turbulence factor f=1.2*turbulence factor
20 1.45 1.74
15 1.37 1.64
10 1.27 1.52
6 1.14 1.37
3 1.07 1.28
1.8
f(x) = − 0.00002135979347904
1.7
+ 0.0000986213627510133 x²
1.6
+ 1.1713602582357000000
R² = 0.9981820238082630000
1.5
1.4
1.3
1.2
1.1
1.4
1.3
1.2
1.1
1
97934790414 x³
7510133 x² + 0.0349403358078105000 x
7000000
82630000
vh/vt
00 x
Viscosity vs. temperature
0.02
Viscosity (in poise)
0.018
f(x) = 0.0000000000314883016339438 x⁴ − 0.0000000198359271686222000 x³ + 0.0000047858489752853000000 x²
− 0.0005579906068530540000000 x + 0.0314145949124697000000000
0.016 R² = 0.9997858425917630000000000
0.014
0.012
0.01
0.008
0.006
0.004
0.002
0
0 50 100 150 200 250
Temperature (deg F)